Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Foot Ankle Surg ; 22(4): 274-277, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27810028

RESUMO

BACKGROUND: Assessment of ankle joint movement in a weight bearing position has important clinical implications. The lunge ankle dorsiflexion measurement device (LAD) has been developed with the aim of facilitating ease of and standardisation of the measurement of ankle joint movement. The literature lacks studies evaluating the reliability of weight bearing measurements of the ankle joint in study groups with ankle disabilities. The objective of this study was to examine the intra- and inter-tester reliability of ankle dorsiflexion measured with the novel LAD in patients following a fracture of the ankle. METHOD: This study was a randomized intra- and inter-tester reliability study with blinding of testers and participants. All participants were tested twice by each tester, with the order of testers randomized. The intra- and inter-tester reliability was assessed by the calculation of interclass correlation coefficients (ICC). RESULTS: The study sample consisted of 24 patients: 15 females and nine males post-immobilisation following surgery for ankle fractures. The mean age was 51.0 years, ranging from 22 to 92 years. All patients had sustained an AO classification 44- fracture of the ankle. The mean follow-up time was 9.3 months (16.2 SD) after the time of fracture. The inter-tester reliability was high, with an ICC of 0.984 (95%CI: 0.963-0.993) and SEmeas of 0.14cm. The ICC for Tester A was 0.989 (95%CI: 0.974-0.995) and SEmeas 0.10cm. The ICC for Tester B was 0.990 (95%CI: 0.977-0.996) and SEmeas 0.09cm. CONCLUSION: This study shows a high inter- and intra-tester reliability for measuring ankle dorsiflexion with the LAD following a fracture of the ankle.


Assuntos
Fraturas do Tornozelo/cirurgia , Artrometria Articular/instrumentação , Terapia por Exercício/métodos , Fixação Interna de Fraturas/métodos , Amplitude de Movimento Articular/fisiologia , Adulto , Idoso , Análise de Variância , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/reabilitação , Fenômenos Biomecânicos , Desenho de Equipamento , Feminino , Seguimentos , Fixação Interna de Fraturas/efeitos adversos , Humanos , Escala de Gravidade do Ferimento , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Cuidados Pós-Operatórios/métodos , Reprodutibilidade dos Testes , Método Simples-Cego , Resultado do Tratamento , Suporte de Carga , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA