RESUMO
We aimed to discuss and evaluate the technical success and efficacy of the ArtVentive endoluminal occlusion system (EOS) device for splenic embolization. A retrospective review was undertaken for all patients in whom the EOS device was deployed for the purpose of splenic embolization. Data was collected by a search of splenic artery embolization procedures in the hospital computer database. Data was reviewed for all patients in whom an EOS plug was deployed. Patient demographics, technical aspects of the procedure and follow-up at one month were reviewed. We review the technical success and efficacy of this occlusion device. Six patients underwent splenic embolization with the EOS plug. There were 5 male and 1 female patients; age range was 24-88 years. Five 8 mm and one 5 mm EOS plugs were deployed for the occlusion of the splenic artery. The technical success rate was 100% occurring in all 6 splenic arteries. One patient underwent a second angiogram and subsequent splenectomy for persistent splenic hemorrhage. One patient had a subsequent splenectomy for bacteremia with the spleen as the suspected source. This early data supports the efficacy of the EOS plug for the embolization of the proximal splenic artery.
Assuntos
Embolização Terapêutica , Artéria Esplênica , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Baço/diagnóstico por imagem , Baço/cirurgia , Artéria Esplênica/diagnóstico por imagem , Resultado do Tratamento , Adulto JovemRESUMO
Concerns have been raised in the literature, regarding the risk of venous thromboembolic events associated with the use of thermoregulatory catheters. Inferior vena cava (IVC) filters are commonly used to prevent venous thromboembolic events. We demonstrate the usefulness of IVC filter placement prior to the removal of thermoregulatory warming catheters. The management of thermoregulatory warming catheter associated venous thromboembolism is outlined through a retrospective case series of three patients. In one case IVC thrombus was incidentally detected at ultrasonography one-week post removal. The second case describes the occurrence of pulseless electrical activity arrest secondary to massive pulmonary embolism immediately post removal of the thermoregulatory catheter, and subsequent interventional radiology management including pulmonary thrombectomy and caval filter placement. The third case is of a patient in whom the removal of the warming catheter was performed in the angiography suite, with placement of IVC filter prior to removal. Venography displayed a large thrombus burden within the IVC filter. There is limited data in the literature regarding the use of IVC filters as prophylaxis in patients with thermoregulatory catheters, particularly warming catheters. We advocate the placement of an IVC filter prior to the removal of warming catheters. We raise awareness regarding the potential risks of venous thromboembolism in this population and the key role interventional radiology has in the management of these patients.