Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 124
Filtrar
1.
J Am Heart Assoc ; 13(9): e032837, 2024 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-38639355

RESUMO

Evidence from medicine and other fields has shown that gender diversity results in better decision making and outcomes. The incoming workforce of congenital heart specialists (especially in pediatric cardiology) appears to be more gender balanced, but past studies have shown many inequities. Gender-associated differences in leadership positions, opportunities presented for academic advancement, and recognition for academic contributions to the field persist. In addition, compensation packages remain disparate if evaluated based on gender with equivalent experience and expertise. This review explores these inequities and has suggested individual and institutional changes that could be made to recruit and retain women, monitor the climate of the institution, and identify and eliminate bias in areas like salary and promotions.


Assuntos
Equidade de Gênero , Cardiopatias Congênitas , Médicas , Humanos , Cardiopatias Congênitas/epidemiologia , Cardiopatias Congênitas/terapia , Feminino , Médicas/estatística & dados numéricos , Médicas/tendências , Masculino , Liderança , Cardiologia/tendências , Pediatria/tendências , Salários e Benefícios , Sexismo/tendências , Fatores Sexuais , Cardiologistas/tendências
3.
J Am Heart Assoc ; 13(5): e029798, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38390878

RESUMO

BACKGROUND: The complexity of congenital heart disease has been primarily stratified on the basis of surgical technical difficulty, specific diagnoses, and associated outcomes. We report on the refinement and validation of a pediatric echocardiography complexity (PEC) score. METHODS AND RESULTS: The American College of Cardiology Quality Network assembled a panel from 12 centers to refine a previously published PEC score developed in a single institution. The panel refined complexity categories and included study modifiers to account for complexity related to performance of the echocardiogram. Each center submitted data using the PEC scoring tool on 15 consecutive inpatient and outpatient echocardiograms. Univariate and multivariate analyses were performed to assess for independent predictors of longer study duration. Among the 174 echocardiograms analyzed, 68.9% had underlying congenital heart disease; 44.8% were outpatient; 34.5% were performed in an intensive care setting; 61.5% were follow-up; 46.6% were initial or preoperative; and 9.8% were sedated. All studies had an assigned PEC score. In univariate analysis, longer study duration was associated with several patient and study variables (age <2 years, PEC 4 or 5, initial study, preoperative study, junior or trainee scanner, and need for additional imaging). In multivariable analysis, a higher PEC score of 4 or 5 was independently associated with longer study duration after controlling for study variables and center variation. CONCLUSIONS: The PEC scoring tool is feasible and applicable in a variety of clinical settings and can be used for correlation with diagnostic errors, allocation of resources, and assessment of physician and sonographer effort in performing, interpreting, and training in pediatric echocardiography.


Assuntos
Cardiopatias Congênitas , Melhoria de Qualidade , Criança , Humanos , Pré-Escolar , Consenso , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Erros de Diagnóstico , Ecocardiografia
4.
Echocardiography ; 41(2): e15766, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38340258

RESUMO

BACKGROUND: A previous multicenter study showed that longitudinal changes in standard cardiac functional parameters were associated with the development of cardiomyopathy in childhood cancer survivors (CCS). Evaluation of the relationship between global longitudinal strain (GLS) changes and cardiomyopathy risk was limited, largely due to lack of quality apical 2- and 3-chamber views in addition to 4-chamber view. We sought to determine whether apical 4-chamber longitudinal strain (A4LS) alone can serve as a suitable surrogate for GLS in this population. METHODS: A4LS and GLS were measured in echocardiograms with acceptable apical 2-, 3-, and 4-chamber views. Correlation was evaluated using Pearson and Spearman coefficients, and agreement was evaluated with Bland-Altman plots. The ability of A4LS to identify normal and abnormal values compared to GLS as the reference was evaluated. RESULTS: Among a total of 632 reviewed echocardiograms, we identified 130 echocardiograms from 56 patients with adequate views (38% female; mean age at cancer diagnosis 8.3 years; mean follow-up 9.4 years). Correlation coefficients between A4LS and GLS were .89 (Pearson) and .85 (Spearman), with Bland-Altman plot of GLS-A4LS showing a mean difference of -.71 ± 1.8. Compared with GLS as the gold standard, A4LS had a sensitivity of 86% (95% CI 79%-93%) and specificity of 82% (69%-95%) when using normal range cutoffs and 90% (82%-97%) and 70% (58%-81%) when using ±2 standard deviations. CONCLUSION: A4LS performs well when compared with GLS in this population. Given the more recent adoption of apical 2- and 3-chamber views in most pediatric echocardiography laboratories, A4LS is a reasonable stand-alone measurement in retrospective analyses of older study cohorts and echocardiogram biorepositories.


Assuntos
Sobreviventes de Câncer , Cardiomiopatias , Neoplasias , Disfunção Ventricular Esquerda , Criança , Feminino , Humanos , Masculino , Ecocardiografia , Neoplasias/complicações , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda , Adolescente
5.
J Am Soc Echocardiogr ; 37(2): 119-170, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38309834

RESUMO

Echocardiography is a fundamental component of pediatric cardiology, and appropriate indications have been established for its use in the setting of suspected, congenital, or acquired heart disease in children. Since the publication of guidelines for pediatric transthoracic echocardiography in 2006 and 2010, advances in knowledge and technology have expanded the scope of practice beyond the use of traditional modalities such as two-dimensional, M-mode, and Doppler echocardiography to evaluate the cardiac segmental structures and their function. Adjunct modalities such as contrast, three-dimensional, and speckle-tracking echocardiography are now used routinely at many pediatric centers. Guidelines and recommendations for the use of traditional and newer adjunct modalities in children are described in detail in this document. In addition, suggested protocols related to standard operations, infection control, sedation, and quality assurance and improvement are included to provide an organizational structure for centers performing pediatric transthoracic echocardiograms.


Assuntos
Cardiologia , Cardiopatias , Criança , Humanos , Estados Unidos , Ecocardiografia/métodos , Ecocardiografia Doppler/métodos
6.
J Am Coll Cardiol ; 83(1): 63-81, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38171712

RESUMO

Recent years have witnessed exponential growth in cardiac imaging technologies, allowing better visualization of complex cardiac anatomy and improved assessment of physiology. These advances have become increasingly important as more complex surgical and catheter-based procedures are evolving to address the needs of a growing congenital heart disease population. This state-of-the-art review presents advances in echocardiography, cardiac magnetic resonance, cardiac computed tomography, invasive angiography, 3-dimensional modeling, and digital twin technology. The paper also highlights the integration of artificial intelligence with imaging technology. While some techniques are in their infancy and need further refinement, others have found their way into clinical workflow at well-resourced centers. Studies to evaluate the clinical value and cost-effectiveness of these techniques are needed. For techniques that enhance the value of care for congenital heart disease patients, resources will need to be allocated for education and training to promote widespread implementation.


Assuntos
Inteligência Artificial , Cardiopatias Congênitas , Humanos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Ecocardiografia , Técnicas de Imagem Cardíaca/métodos , Imageamento por Ressonância Magnética/métodos
7.
Cardiol Young ; 34(4): 846-853, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37905328

RESUMO

OBJECTIVE: To characterise transesophageal echocardiography practice patterns among paediatric cardiac surgical centres in the United States and Canada. METHODS: A 42-question survey was sent to 80 echocardiography laboratory directors at paediatric cardiology centres with surgical programmes in the United States and Canada. Question domains included transesophageal echocardiography centre characteristics, performance and reporting, equipment use, trainee participation, and quality assurance. RESULTS: Fifty of the 80 centres (62.5%) responded to the survey. Most settings were academic (86.0%) with 42.0% of centres performing > 350 surgical cases/year. The median number of transesophageal echocardiograms performed/cardiologist/year was 50 (26, 73). Pre-operative transesophageal echocardiography was performed in most surgical cases by 91.7% of centres. Transesophageal echocardiography was always performed by most centres following Norwood, Glenn, and Fontan procedures and by < 10% of centres following coarctation repair. Many centres with a written guideline allowed transesophageal echocardiography transducer use at weights below manufacturer recommendations (50.0 and 61.1% for neonatal and paediatric transducers, respectively). Most centres (36/37, 97.3%) with categorical fellowships had rotations which included transesophageal echocardiography participation. Large surgical centres (>350 cases/year) had higher median number of transesophageal echocardiograms/cardiologist/year (75.5 [53, 86] versus 35 [20, 52], p < 0.001) and more frequently used anaesthesia for diagnostic transesophageal echocardiography ≥ 67% of time (100.0 versus 62.1%, p = 0.001). CONCLUSIONS: There is significant variability in transesophageal echocardiography practice patterns and training requirements among paediatric cardiology centres in the United States and Canada. Findings may help inform programmatic decisions regarding transesophageal echocardiography expectations, performance and reporting, equipment use, trainee involvement, and quality assurance.


Assuntos
Cardiologia , Técnica de Fontan , Recém-Nascido , Estados Unidos , Humanos , Criança , Ecocardiografia Transesofagiana , Ecocardiografia , Cardiologia/educação , Canadá
8.
Front Cardiovasc Med ; 10: 1286241, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38107263

RESUMO

Background: Pediatric acute myeloid leukemia (AML) therapy is associated with substantial short- and long-term treatment-related cardiotoxicity mainly due to high-dose anthracycline exposure. Early left ventricular systolic dysfunction (LVSD) compromises anthracycline delivery and is associated with inferior event-free and overall survival in de novo pediatric AML. Thus, effective cardioprotective strategies and cardiotoxicity risk predictors are critical to optimize cancer therapy delivery and enable early interventions to prevent progressive LVSD. While dexrazoxane-based cardioprotection reduces short-term cardiotoxicity without compromising cancer survival, liposomal anthracycline formulations have the potential to mitigate cardiotoxicity while improving antitumor efficacy. This overview summarizes the rationale and methodology of cardiac substudies within AAML1831, a randomized Children's Oncology Group Phase 3 study of CPX-351, a liposomal formulation of daunorubicin and cytarabine, in comparison with standard daunorubicin/cytarabine with dexrazoxane in the treatment of de novo pediatric AML. Methods/design: Children (age <22 years) with newly diagnosed AML were enrolled and randomized to CPX-351-containing induction 1 and 2 (Arm A) or standard daunorubicin and dexrazoxane-containing induction (Arm B). Embedded cardiac correlative studies aim to compare the efficacy of this liposomal anthracycline formulation to dexrazoxane for primary prevention of cardiotoxicity by detailed core lab analysis of standardized echocardiograms and serial cardiac biomarkers throughout AML therapy and in follow-up. In addition, AAML1831 will assess the ability of early changes in sensitive echo indices (e.g., global longitudinal strain) and cardiac biomarkers (e.g., troponin and natriuretic peptides) to predict subsequent LVSD. Finally, AAML1831 establishes expert consensus-based strategies in cardiac monitoring and anthracycline dose modification to balance the potentially competing priorities of cardiotoxicity reduction with optimal leukemia therapy. Discussion: This study will inform diagnostic, prognostic, preventative, and treatment strategies regarding cardiotoxicity during pediatric AML therapy. Together, these measures have the potential to improve leukemia-free and overall survival and long-term cardiovascular health in children with AML. Clinical trial registration: https://clinicaltrials.gov/, identifier NCT04293562.

11.
Pediatr Cardiol ; 2023 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-37354371

RESUMO

Vascular rings are increasingly identified on fetal echocardiography. The purpose of this study is to analyze clinical outcomes and patterns of diagnostic testing in fetuses with vascular rings diagnosed by echocardiography. A retrospective cohort study was performed of fetuses with postnatally confirmed vascular rings from 2017 to 2022. Clinical outcomes included type and timing of symptoms, and timing of surgical intervention. Freedom from symptoms and/or surgery was assessed by Kaplan-Meier analysis. Frequency of genetic and diagnostic testing (barium esophagogram, CT/MRI angiogram, and bronchoscopy) was also assessed. Overall, 46 patients were evaluated (91% with a right aortic arch/left ductus and 4% with a double aortic arch). A vascular ring was isolated in 59%, associated with structural heart lesions in 33%, and associated with noncardiac anomalies in 8%. Prenatal diagnoses increased over time. Symptoms developed in 24% (11/46); 82% (9/11) had respiratory and 45% (5/11) had gastroesophageal complaints. Surgery was performed in 17% (11/46). Symptoms presented bimodally, prior to 100 or after 400 days of life. There was no difference in the type of symptoms for early (< 100 days) or late (> 400 days) presenters. Symptomatic patients received more diagnostic testing. Genetic testing was obtained in 46% and positive in 33%, with 22q11 deletion and Trisomy 21 being identified. Prenatal diagnoses of vascular rings increased over time, with subjects developing symptoms bimodally in early or late infancy. The frequency of genetic testing was suboptimal given the prevalence of genetic abnormalities seen in this population.

13.
J Cardiovasc Comput Tomogr ; 17(3): 211-219, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36868899

RESUMO

BACKGROUND: To promote the rational use of cardiovascular imaging in patients with congenital heart disease, the American College of Cardiology developed Appropriate Use Criteria (AUC), but its clinical application and pre-release benchmarks have not been evaluated. We aimed to evaluate the appropriateness of indications for cardiovascular magnetic resonance (CMR) and cardiovascular computed tomography (CCT) in patients with conotruncal defects and to identify factors associated with maybe or rarely appropriate (M/R) indications. METHODS: Twelve centers each contributed a median of 147 studies performed prior to AUC publication (01/2020) on patients with conotruncal defects. To incorporate patient characteristics and center-level effects, a hierarchical generalized linear mixed model was used. RESULTS: Of the 1753 studies (80% CMR, and 20% CCT), 16% were rated M/R. Center M/R ranged from 4 to 39%. Infants accounted for 8.4% of studies. In multivariable analyses, patient- and study-level factors associated with M/R rating included: age <1 year (OR 1.90 [1.15-3.13]), truncus arteriosus (vs. tetralogy of Fallot, OR 2.55 [1.5-4.35]), and CCT (vs. CMR, OR 2.67 [1.87-3.83]). None of the provider- or center-level factors reached statistical significance in the multivariable model. CONCLUSIONS: Most CMRs and CCTs ordered for the follow-up care of patients with conotruncal defects were rated appropriate. However, there was significant center-level variation in appropriateness ratings. Younger age, CCT, and truncus arteriosus were independently associated with higher odds of M/R rating. These findings could inform future quality improvement initiatives and further exploration of factors resulting in center-level variation.


Assuntos
Cardiopatias Congênitas , Lactente , Humanos , Valor Preditivo dos Testes , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Tomografia Computadorizada por Raios X , Imageamento por Ressonância Magnética
14.
Prog Pediatr Cardiol ; 67: 101549, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35813038

RESUMO

Background: The COVID pandemic necessitated an altered approach to transthoracic echocardiography, especially in COVID cases. Whether this has effected echocardiography lab quality is unknown. Objectives: We sought to determine whether echocardiography lab quality measures during the COVID pandemic were different from those prior to the pandemic and whether quality and comprehensiveness of echocardiograms performed during the pandemic was different between COVID and non-COVID patients. Methods: The four quality measures (diagnostic errors, appropriateness of echocardiogram, American College of Cardiology Image Quality metric and Comprehensive Exam metric in structurally normal hearts) reported quarterly in our lab were compared between two quarters during COVID (2020) and pre-COVID (2019). Each component of these metrics was also assessed in randomly selected echocardiograms in COVID patients and compared to non-COVID echocardiograms. Results: For non-COVID echocardiograms, the image quality metric did not change between 2019 and 2020 and the comprehensive exam metric improved. Diagnostic error rate did not change, and appropriateness of echocardiogram indications improved. When COVID and non-COVID echocardiograms were compared, the image quality metric and comprehensiveness exam metric were lower for COVID cases (image quality mean 21.3/23 for non-COVID, 18.6/23 for COVID, p < 0.001 and comprehensive exam mean 29.5/30 for non-COVID, 27.7/39 for COVID, p < 0.001). In particular, systemic and pulmonary veins, pulmonary arteries and aortic arch were not adequately imaged in COVID patients. For studies in which a follow-up echocardiogram was available, no new pathology was found. Conclusions: At our center, though diagnostic error rate did not change during the pandemic and the proportion of echocardiograms ordered for appropriate indications increased, imaging quality in COVID patients was compromised, especially for systemic and pulmonary veins, pulmonary arteries and arch. Though no new pathology was noted on the small number of patients who had follow-up studies, we are paying careful attention to these structures to avoid diagnostic errors going forward.

15.
J Am Soc Echocardiogr ; 35(10): 1084-1090.e19, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35568251

RESUMO

BACKGROUND: Indications for transthoracic echocardiography (TTE) from the 2020 Appropriate Use Criteria (AUC) for congenital heart disease (CHD) were incorporated into the institutional electronic ordering system as a clinical decision support tool. The purpose of this study was to evaluate the utilization of TTE and factors affecting the appropriateness of orders for TTE during follow-up care of patients with CHD. METHODS: All transthoracic echocardiographic studies performed during follow-up clinic visits from May 1, 2020, to November 30, 2020, were included. Indications for TTE were rated appropriate, may be appropriate, or rarely appropriate on the basis of the AUC and unclassifiable if the indication was not in the document but related to included lesions. CHD was graded as simple, moderate, or complex on the basis of the Bethesda classification. Logistic regression was used to determine the association of ratings with patient age, insurance status, CHD complexity, and clinician experience and specialty. RESULTS: Of the 5,158 studies, 3,979 (77.2%) were for CHD included in the AUC document, 322 (8%) were unclassifiable, 37 (0.7%) were for CHD not in the document, and 1,142 (22.1%) were for non-CHD indications. Of the 3,657 transthoracic echocardiographic examinations to which AUC ratings could be applied, 95.6% were rated appropriate, 2.4% may be appropriate, and 2.0% rarely appropriate. The highest utilization of TTE was for follow-up of ventricular septal defects, left ventricular outflow tract obstruction, and single ventricles; 46% for unrepaired CHD; 78% for routine surveillance; and the remaining for changes in clinical status. On multivariable analysis, the only significant factor associated with may be appropriate and rarely appropriate ratings was simple CHD (odds ratio, 11.58; 95% CI, 5.36 - 24.98; P < .001). CONCLUSIONS: Three quarters of transthoracic echocardiographic studies ordered during follow-up care in pediatric cardiology clinics are for indications related to CHD. Most examinations for follow-up of CHD were for routine surveillance and indications rated appropriate. Orders for TTE for may be appropriate and rarely appropriate ratings were associated with simple CHD. Although the 2020 AUC document successfully stratifies the majority of indications related to CHD, future documents should consider the unclassifiable CHD indications and the non-CHD indications.


Assuntos
Fidelidade a Diretrizes , Cardiopatias Congênitas , Assistência ao Convalescente , Criança , Ecocardiografia , Cardiopatias Congênitas/diagnóstico por imagem , Humanos
16.
Pediatr Exerc Sci ; 33(4): 196-202, 2021 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-34303306

RESUMO

BACKGROUND: Elevated left ventricular outflow tract (LVOT) gradients during exercise can occur in patients with hypertrophic cardiomyopathy (HCM) as well as in athletes and normal controls. The authors' staged exercise protocol calls for imaging at rest and during each stage of exercise to evaluate the mechanism of LVOT obstruction at each stage. They investigated whether this staged approach helps differentiate HCM from athletes and normal controls. METHODS: They reviewed pediatric exercise stress echocardiograms completed between January 2009 and October 2017 at their center and identified those with gene-positive HCM, athlete's heart, and normal controls. Children with inducible obstruction (those with no LVOT gradient at rest who developed a LVOT peak gradient > 25 mm Hg during exercise) were included. LVOT peak gradient, velocity time integral, acceleration time, and deceleration time were measured at rest, submaximal stages, and peak exercise. RESULTS: Compared with athletes, HCM patients had significantly higher LVOT peak gradients at rest (P = .019), stage 1 of exercise (P = .002), and peak exercise (P = .051), as well as a significantly higher change in LVOT peak gradient from rest to stage 1 (P = .016) and from rest to peak (P = .038). The acceleration time/deceleration time ratio of the LVOT Doppler was significantly lower in HCM patients compared with normal controls at peak exercise. CONCLUSIONS: The HCM patients who develop elevated LVOT gradients at peak exercise typically manifest early obstruction in the submaximal stages of exercise, which helps to differentiate them from athletes and normal controls.


Assuntos
Cardiomiopatia Hipertrófica , Obstrução do Fluxo Ventricular Externo , Atletas , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Criança , Ecocardiografia sob Estresse , Teste de Esforço , Humanos , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem
17.
Pediatr Cardiol ; 42(6): 1284-1292, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33877418

RESUMO

Normalizing cardiovascular measurements for body size allows for comparison among children of different ages and for distinguishing pathologic changes from normal physiologic growth. Because of growing interest to use height for normalization, the aim of this study was to develop height-based normalization models and compare them to body surface area (BSA)-based normalization for aortic and left ventricular (LV) measurements. The study population consisted of healthy, non-obese children between 2 and 18 years of age enrolled in the Pediatric Heart Network Echo Z-Score Project. The echocardiographic study parameters included proximal aortic diameters at 3 locations, LV end-diastolic volume, and LV mass. Using the statistical methodology described in the original project, Z-scores based on height and BSA were determined for the study parameters and tested for any clinically significant relationships with age, sex, race, ethnicity, and body mass index (BMI). Normalization models based on height versus BSA were compared among underweight, normal weight, and overweight (but not obese) children in the study population. Z-scores based on height and BSA were calculated for the 5 study parameters and revealed no clinically significant relationships with age, sex, race, and ethnicity. Normalization based on height resulted in lower Z-scores in the underweight group compared to the overweight group, whereas normalization based on BSA resulted in higher Z-scores in the underweight group compared to the overweight group. In other words, increasing BMI had an opposite effect on height-based Z-scores compared to BSA-based Z-scores. Allometric normalization based on height and BSA for aortic and LV sizes is feasible. However, height-based normalization results in higher cardiovascular Z-scores in heavier children, and BSA-based normalization results in higher cardiovascular Z-scores in lighter children. Further studies are needed to assess the performance of these approaches in obese children with or without cardiac disease.


Assuntos
Estatura , Superfície Corporal , Doenças Cardiovasculares/diagnóstico , Coração/anatomia & histologia , Adolescente , Doenças Cardiovasculares/diagnóstico por imagem , Criança , Pré-Escolar , Bases de Dados Factuais , Ecocardiografia , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Obesidade Infantil/epidemiologia , Pediatria , Valores de Referência
18.
Cardiol Young ; 31(10): 1595-1607, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33650482

RESUMO

BACKGROUND: Although cardiac catheterisation (cath) is the diagnostic test for pulmonary hypertension, it is an invasive procedure. Echocardiography (echo) is commonly used for the non-invasive diagnosis of pulmonary hypertension but maybe limited by lack of adequate signals. Therefore, emphasis has been placed on biomarkers as a potential diagnostic tool. No prior paediatric studies have simultaneously compared N-terminal pro-B-type-natriuretic peptide (NTproBNP) with cath/echo as a potential diagnostic tool. The aim of this study was to determine if NTproBNP was a reliable diagnostic tool for pulmonary hypertension in this population. METHODS: Patients were divided into Study (echo evidence/established diagnosis of pulmonary hypertension undergoing cath) and Control (cath for small atrial septal defect/patent ductus arteriosus and endomyocardial biopsy post cardiac transplant) groups. NTproBNP, cath/echo data were obtained. RESULTS: Thirty-one patients met inclusion criteria (10 Study, 21 Control). Median NTproBNP was significantly higher in the Study group. Echo parameters including transannular plane systolic excursion z scores, pulmonary artery acceleration time and right ventricular fractional area change were lower in the Study group and correlated negatively with NTproBNP. Receiver operation characteristic curve analysis demonstrated NTproBNP > 389 pg/ml was 87% specific for the diagnosis of pulmonary hypertension with the addition of pulmonary artery acceleration time improving the specificity. CONCLUSIONS: NTproBNP may be a valuable adjunctive diagnostic tool for pulmonary hypertension in the paediatric population. Echo measures of transannular plane systolic excursion z score, pulmonary artery acceleration time and right ventricular fractional area change had negative correlations with NTproBNP. The utility of NTproBNP as a screening tool for pulmonary hypertension requires validation in a population with unknown pulmonary hypertension status.


Assuntos
Hipertensão Pulmonar , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Biomarcadores , Criança , Humanos , Hipertensão Pulmonar/diagnóstico , Estudos Prospectivos
19.
Am Heart J ; 236: 69-79, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33640333

RESUMO

OBJECTIVE: While the surgical stages of single ventricle (SV) palliation serve to separate pulmonary venous and systemic venous return, and to volume-unload the SV, staged palliation also results in transition from parallel to series circulation, increasing total vascular resistance. How this transition affects pressure loading of the SV is as yet unreported. METHODS: We performed a retrospective chart review of Stage I, II, and III cardiac catheterization (CC) and echocardiographic data from 2001-2017 in all SV pts, with focus on systemic, pulmonary, and total vascular resistance (SVR, PVR, TVR respectively). Longitudinal analyses were performed with log-transformed variables. Effects of SVR-lowering medications were analyzed using Wilcoxon rank-sum testing. RESULTS: There were 372 total patients who underwent CC at a Stage I (median age of 4.4 months, n=310), Stage II (median age 2.7 years, n = 244), and Stage III (median age 7.3 years, n = 113). Total volume loading decreases with progression to Stage III (P< 0.001). While PVR gradually increases from Stage II to Stage III, and SVR increases from Stage I to Stage III, TVR dramatically increases with progress towards series circulation. TVR was not affected by use of systemic vasodilator therapy. TVR, PVR, SVR, and CI did not correlate with indices of SV function at Stage III. CONCLUSIONS: TVR steadily increases with an increasing contribution from SVR over progressive stages. TVR was not affected by systemic vasodilator agents. TVR did not correlate with echo-based indices of SV function. Further studies are needed to see if modulating TVR can improve exercise tolerance and outcomes.


Assuntos
Doenças Assintomáticas/terapia , Procedimentos Cirúrgicos Cardíacos , Coração Univentricular , Resistência Vascular/fisiologia , Circulação Sanguínea , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Procedimentos Cirúrgicos Cardíacos/estatística & dados numéricos , Criança , Pré-Escolar , Progressão da Doença , Ecocardiografia/métodos , Feminino , Humanos , Lactente , Estudos Longitudinais , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Cuidados Paliativos/métodos , Estudos Retrospectivos , Tempo , Coração Univentricular/diagnóstico por imagem , Coração Univentricular/fisiopatologia , Coração Univentricular/cirurgia , Vasodilatadores/uso terapêutico , Função Ventricular
20.
Echocardiography ; 38(2): 296-303, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33486820

RESUMO

BACKGROUND: Retrospective multicenter research using echocardiograms obtained for routine clinical care can be hampered by issues of individual center quality. We sought to evaluate imaging and patient characteristics associated with poorer quality of archived echocardiograms from a cohort of childhood cancer survivors. METHODS: A single blinded reviewer at a central core laboratory graded quality of clinical echocardiograms from five centers focusing on images to derive 2D and M-mode fractional shortening (FS), biplane Simpson's ejection fraction (EF), myocardial performance index (MPI), tissue Doppler imaging (TDI)-derived velocities, and global longitudinal strain (GLS). RESULTS: Of 535 studies analyzed in 102 subjects from 2004 to 2017, all measures of cardiac function could be assessed in only 7%. While FS by 2D or M-mode, MPI, and septal E/E' could be measured in >80% studies, mitral E/E' was less consistent (69%), but better than EF (52%) and GLS (10%). 66% of studies had ≥1 issue, with technical issues (eg, lung artifact, poor endocardial definition) being the most common (33%). Lack of 2- and 3-chamber views was associated with the performing center. Patient age <5 years had a higher chance of apex cutoff in 4-chamber views compared with 16-35 years old. Overall, for any quality issue, earlier era of echo and center were the only significant risk factors. CONCLUSION: Assessment of cardiac function using pooled multicenter archived echocardiograms was significantly limited. Efforts to standardize clinical echocardiographic protocols to include apical 2- and 3-chamber views and TDI will improve the ability to quantitate LV function.


Assuntos
Disfunção Ventricular Esquerda , Função Ventricular Esquerda , Adolescente , Adulto , Pré-Escolar , Estudos de Coortes , Ecocardiografia , Humanos , Estudos Retrospectivos , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...