Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Adv Mater ; 36(8): e2306679, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38061027

RESUMO

Air liquid interfaced (ALI) epithelial barriers are essential for homeostatic functions such as nutrient transport and immunological protection. Dysfunction of such barriers are implicated in a variety of autoimmune and inflammatory disorders and, as such, sensors capable of monitoring barrier health are integral for disease modelling, diagnostics and drug screening applications. To date, gold-standard electrical methods for detecting barrier resistance require rigid electrodes bathed in an electrolyte, which limits compatibility with biological architectures and is non-physiological for ALI. This work presents a flexible all-planar electronic device capable of monitoring barrier formation and perturbations in human respiratory and intestinal cells at ALI. By interrogating patient samples with electrochemical impedance spectroscopy and simple equivalent circuit models, disease-specific and patient-specific signatures are uncovered. Device readouts are validated against commercially available chopstick electrodes and show greater conformability, sensitivity and biocompatibility. The effect of electrode size on sensing efficiency is investigated and a cut-off sensing area is established, which is one order of magnitude smaller than previously reported. This work provides the first steps in creating a physiologically relevant sensor capable of mapping local and real-time changes of epithelial barrier function at ALI, which will have broad applications in toxicology and drug screening applications.


Assuntos
Eletrônica , Humanos , Eletrodos
2.
Mater Horiz ; 10(9): 3589-3600, 2023 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-37318042

RESUMO

Three-dimensional in vitro stem cell models have enabled a fundamental understanding of cues that direct stem cell fate. While sophisticated 3D tissues can be generated, technology that can accurately monitor these complex models in a high-throughput and non-invasive manner is not well adapted. Here we show the development of 3D bioelectronic devices based on the electroactive polymer poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate)-(PEDOT:PSS) and their use for non-invasive, electrical monitoring of stem cell growth. We show that the electrical, mechanical and wetting properties as well as the pore size/architecture of 3D PEDOT:PSS scaffolds can be fine-tuned simply by changing the processing crosslinker additive. We present a comprehensive characterization of both 2D PEDOT:PSS thin films of controlled thicknesses, and 3D porous PEDOT:PSS structures made by the freeze-drying technique. By slicing the bulky scaffolds we generate homogeneous, porous 250 µm thick PEDOT:PSS slices, constituting biocompatible 3D constructs able to support stem cell cultures. These multifunctional slices are attached on indium-tin oxide substrates (ITO) with the help of an electrically active adhesion layer, enabling 3D bioelectronic devices with a characteristic and reproducible, frequency dependent impedance response. This response changes drastically when human adipose derived stem cells (hADSCs) grow within the porous PEDOT:PSS network as revealed by fluorescence microscopy. The increase of cell population within the PEDOT:PSS porous network impedes the charge flow at the interface between PEDOT:PSS and ITO, enabling the interface resistance (R1) to be used as a figure of merit to monitor the proliferation of stem cells. The non-invasive monitoring of stem cell growth allows for the subsequent differentiation 3D stem cell cultures into neuron like cells, as verified by immunofluorescence and RT-qPCR measurements. The strategy of controlling important properties of 3D PEDOT:PSS structures simply by altering processing parameters can be applied for development of a number of stem cell in vitro models as well as stem cell differentiation pathways. We believe the results presented here will advance 3D bioelectronic technology for both fundamental understanding of in vitro stem cell cultures as well as the development of personalized therapies.


Assuntos
Células-Tronco Adultas , Eletricidade , Humanos , Neurônios , Diferenciação Celular , Impedância Elétrica
3.
Methods Mol Biol ; 2679: 305-314, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37300625

RESUMO

Noninvasive collection of target cells such as circulating tumor cells (CTCs) is crucial for biology and medicine research. Conventional methods of cell collection are often complex, requiring either size-dependent sorting or invasive enzymatic reactions. Here, we show the development of a functional polymer film, which combines the thermoresponsive poly(N-isopropylacrylamide) and the conducting poly(3,4-ethylenedioxythiopene)/poly(styrene sulfonate), and its use for the capture and release of CTCs. When coated onto microfabricated gold electrodes, the proposed polymer films are capable of noninvasively capturing and controllably releasing cells while, at the same time, monitoring these processes with conventional electrical measurements.


Assuntos
Neoplasias , Polímeros , Eletrodos , Poliestirenos
4.
Adv Healthc Mater ; 11(20): e2200941, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35904257

RESUMO

3D cell culture formats more closely resemble tissue architecture complexity than 2D systems, which are lacking most of the cell-cell and cell-microenvironment interactions of the in vivo milieu. Scaffold-based systems integrating natural biomaterials are extensively employed in tissue engineering to improve cell survival and outgrowth, by providing the chemical and physical cues of the natural extracellular matrix (ECM). Using the freeze-drying technique, porous 3D composite scaffolds consisting of poly(3,4-ethylene-dioxythiophene) doped with polystyrene sulfonate (PEDOT:PSS), containing ECM components (i.e., collagen, hyaluronic acid, and laminin) are engineered for hosting neuronal cells. The resulting scaffolds exhibit a highly porous microstructure and good conductivity, determined by scanning electron microscopy and electrochemical impedance spectroscopy, respectively. These supports boast excellent mechanical stability and water uptake capacity, making them ideal candidates for cell infiltration. SH-SY5Y human neuroblastoma cells show enhanced cell survival and proliferation in the presence of ECM compared to PEDOT:PSS alone. Whole-cell patch-clamp recordings acquired from differentiated SHSY5Y cells in the scaffolds demonstrate that ECM constituents promote neuronal differentiation in situ. These findings reinforce the usability of 3D conducting supports as engineered highly biomimetic and functional in vitro tissue-like platforms for drug or disease modeling.


Assuntos
Neuroblastoma , Alicerces Teciduais , Humanos , Materiais Biocompatíveis , Diferenciação Celular , Proliferação de Células , Colágeno/química , Etilenos/análise , Matriz Extracelular/química , Ácido Hialurônico , Laminina , Polímeros , Engenharia Tecidual/métodos , Alicerces Teciduais/química , Microambiente Tumoral
5.
Anal Chim Acta ; 1205: 339753, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35414383

RESUMO

Nowadays, miniaturization and portability are crucial characteristics that need to be considered for the development of water monitoring systems. In particular, the use of handheld technology, including microfluidics, is exponentially expanding due to its versatility, reduction of reagents and minimization of waste, fast analysis times and portability. Here, a hybrid handheld miniaturized polymer platform with a paper-based microfluidic device was developed for the simultaneous detection of nitrite and nitrate in real samples from both, fresh and seawaters. The platform contains an ionogel-based colorimetric sensor for nitrite detection and a paper-based microfluidic device for the in situ conversion of nitrate to nitrite. The platform was fully characterized in terms of its viability as a portable, cheap and quick pollutant detector at the point of need. The calibration was carried out by multivariate analysis of the color of the sensing areas obtained from a taken picture of the device. The limits of detection and quantification, for nitrite were 0.47 and 0.68 mg L-1, while for nitrate were 2.3 and 3.4 mg L-1, found to be within the limits allowed by the environmental authorities, for these two pollutants. Finally, the platform was validated with real water samples, demonstrating its potential to monitor nitrite and nitrate concentrations on-site as a first surveillance step before performing extensive analysis.


Assuntos
Nitratos , Nitritos , Microfluídica , Nitratos/análise , Nitritos/análise , Polímeros , Água
6.
Chem Rev ; 122(4): 4700-4790, 2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-34910876

RESUMO

Bioelectronics have made strides in improving clinical diagnostics and precision medicine. The potential of bioelectronics for bidirectional interfacing with biology through continuous, label-free monitoring on one side and precise control of biological activity on the other has extended their application scope to in vitro systems. The advent of microfluidics and the considerable advances in reliability and complexity of in vitro models promise to eventually significantly reduce or replace animal studies, currently the gold standard in drug discovery and toxicology testing. Bioelectronics are anticipated to play a major role in this transition offering a much needed technology to push forward the drug discovery paradigm. Organic electronic materials, notably conjugated polymers, having demonstrated technological maturity in fields such as solar cells and light emitting diodes given their outstanding characteristics and versatility in processing, are the obvious route forward for bioelectronics due to their biomimetic nature, among other merits. This review highlights the advances in conjugated polymers for interfacing with biological tissue in vitro, aiming ultimately to develop next generation in vitro systems. We showcase in vitro interfacing across multiple length scales, involving biological models of varying complexity, from cell components to complex 3D cell cultures. The state of the art, the possibilities, and the challenges of conjugated polymers toward clinical translation of in vitro systems are also discussed throughout.


Assuntos
Eletrônica , Polímeros , Animais , Reprodutibilidade dos Testes
7.
Anal Chim Acta ; 1186: 338392, 2021 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-34756264

RESUMO

Water quality monitoring of drinking, waste, fresh and seawaters is of great importance to ensure safety and wellbeing for humans, fauna and flora. Researchers are developing robust water monitoring microfluidic devices but, the delivery of a cost-effective, commercially available platform has not yet been achieved. Conventional water monitoring is mainly based on laboratory instruments or sophisticated and expensive handheld probes for on-site analysis, both requiring trained personnel and being time-consuming. As an alternative, microfluidics has emerged as a powerful tool with the capacity to replace conventional analytical systems. Nevertheless, microfluidic devices largely use conventional pumps and valves for operation and electronics for sensing, that increment the dimensions and cost of the final platforms, reducing their commercialization perspectives. In this review, we critically analyze the characteristics of conventional microfluidic devices for water monitoring, focusing on different water sources (drinking, waste, fresh and seawaters), and their application in commercial products. Moreover, we introduce the revolutionary concept of using functional materials such as hydrogels, poly(ionic liquid) hydrogels and ionogels as alternatives to conventional fluidic handling and sensing tools, for water monitoring in microfluidic devices.


Assuntos
Técnicas Analíticas Microfluídicas , Microfluídica , Humanos , Hidrogéis , Dispositivos Lab-On-A-Chip , Qualidade da Água
8.
Biosens Bioelectron ; 191: 113405, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34144472

RESUMO

Non-invasive collection of target cells is crucial for research in biology and medicine. In this work, we combine a thermo-responsive material, poly(N-isopropylacrylamide), with an electroactive material, poly(3,4-ethylene-dioxythiopene):poly(styrene sulfonate), to generate a smart and conductive copolymer for the label-free and non-invasive detection of the capture and release of cells on gold electrodes by electrochemical impedance spectroscopy. The copolymer is functionalized with fibronectin to capture tumor cells, and undergoes a conformational change in response to temperature, causing the release of cells. Simultaneously, the copolymer acts as a sensor, monitoring the capture and release of cancer cells by electrochemical impedance spectroscopy. This platform has the potential to play a role in top-notch label-free electrical monitoring of human cells in clinical settings.


Assuntos
Técnicas Biossensoriais , Espectroscopia Dielétrica , Eletrodos , Ouro , Humanos , Polímeros
9.
Adv Biol (Weinh) ; 5(6): e2000624, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33943040

RESUMO

Respiratory diseases and lower respiratory tract infections are among the leading cause of death worldwide and, especially given the recent severe acute respiratory syndrome coronavirus-2 pandemic, are of high and prevalent socio-economic importance. In vitro models, which accurately represent the lung microenvironment, are of increasing significance given the ethical concerns around animal work and the lack of translation to human disease, as well as the lengthy time to market and the attrition rates associated with clinical trials. This review gives an overview of the biological and immunological components involved in regulating the respiratory epithelium system in health, disease, and infection. The evolution from 2D to 3D cell biology and to more advanced technological integrated models for studying respiratory host-pathogen interactions are reviewed and provide a reference point for understanding the in vitro modeling requirements. Finally, the current limitations and future perspectives for advancing this field are presented.


Assuntos
COVID-19/metabolismo , Interações Hospedeiro-Patógeno/fisiologia , Modelos Biológicos , SARS-CoV-2/fisiologia , Animais , Humanos
10.
Mikrochim Acta ; 188(4): 143, 2021 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-33774708

RESUMO

A microfluidic, label-free optical sensor for water pollutants, which is based on a packed micro-column of microspheres with refractive index similar to that of water, is presented. The perfluoropolyether microspheres are synthetized by membrane emulsification followed by UV irradiation. The microfluidic channel hosting the packed column is transparent when filled with pure water as a consequence of refractive index matching, whereas it scatters light in presence of compounds with lipophilic moieties that spontaneously adsorb on the fluorinated microspheres. The device is characterized by investigating the response to cationic and anionic surfactants. Both the signal growth rate and the recovery rate measured during washing with water depend on the type and concentration of the compounds. The cationic surfactants tested display a larger signal increase, linearly scaling with concentration. A limit of detection of 1 µM is obtained in the current configuration. The water index-matched microspheres enable to access an additional analytical parameter, that is the propagation velocity of the scattering signal along the column. This parameter is also found to scale linearly with concentration, hence providing a complementary analytical tool sensitive to the adhesion kinetics.


Assuntos
Técnicas Analíticas Microfluídicas/métodos , Microesferas , Compostos de Amônio Quaternário/análise , Dodecilsulfato de Sódio/análise , Tensoativos/análise , Poluentes Químicos da Água/análise , Adsorção , Polímeros de Fluorcarboneto/química , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/instrumentação , Compostos de Amônio Quaternário/química , Refratometria , Dodecilsulfato de Sódio/química , Tensoativos/química , Poluentes Químicos da Água/química
11.
Lab Chip ; 18(5): 699-709, 2018 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-29431804

RESUMO

While the microfluidic device itself may be small, often the equipment required to control fluidics in the chip unit is large e.g. pumps, valves and mixing units, which can severely limit practical use and functional scalability. In addition, components associated with fluidic control of the device, more specifically the valves and pumps, contribute significantly to the overall unit cost. Here we sketch the problem of a gap between high end accurate, but expensive sensor platforms, versus less accurate, but widely employable hand-held low-cost devices. Recent research has shown that the integration of light-responsive materials within microfluidic devices can provide the function of expensive fluidic components, and potentially enable sophisticated measurements to be made using much less expensive equipment. An overview of the most recent developments will be presented for valves, mixers, transport and sample handling inside microfluidic devices.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA