Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Surg Endosc ; 38(5): 2505-2514, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38467860

RESUMO

BACKGROUND: Accurate measurement of polyps size is crucial in predicting malignancy, planning relevant intervention strategies and surveillance schedules. Endoscopists' visual estimations can lack precision. This study builds on our prior research, with the aim to evaluate a recently developed quantitative method to measure the polyp size and location accurately during a simulated endoscopy session. METHODS: The quantitative method merges information about endoscopic positions obtained from an electromagnetic tracking sensor, with corresponding points on the images of the segmented polyp border. This yields real-scale 3D coordinates of the border of the polyp. By utilising the sensor, positions of any anatomical landmarks are attainable, enabling the estimation of a polyp's location relative to them. To verify the method's reliability and accuracy, simulated endoscopies were conducted in pig stomachs, where polyps were artificially created and assessed in a test-retest manner. The polyp measurements were subsequently compared against clipper measurements. RESULTS: The average size of the fifteen polyps evaluated was approximately 12 ± 4.3 mm, ranging from 5 to 20 mm. The test-retest reliability, measured by the Intraclass Correlation Coefficient (ICC) for polyp size estimation, demonstrated an absolute agreement of 0.991 (95% CI 0.973-0.997, p < 0.05). Bland & Altman analysis revealed a mean estimation difference of - 0.17 mm (- 2.03%) for polyp size and, a mean difference of - 0.4 mm (- 0.21%) for polyp location. Both differences were statistically non-significant (p > 0.05). When comparing the proposed method with calliper measurements, the Bland & Altman plots showed 95% of size estimation differences between - 1.4 and 1.8 mm (- 13 to 17.4%) which was not significant (p > 0.05). CONCLUSIONS: The proposed method of measurements of polyp size and location was found to be highly accurate, offering great potential for clinical implementation to improve polyp assessment. This level of performance represents a notable improvement over visual estimation technique used in clinical practice.


Assuntos
Endoscopia Gastrointestinal , Animais , Suínos , Reprodutibilidade dos Testes , Endoscopia Gastrointestinal/métodos , Pólipos/patologia
2.
Int J Comput Assist Radiol Surg ; 19(2): 321-329, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37596379

RESUMO

PURPOSE: Polyp size is an important factor that may influence diagnosis and clinical management decision, but estimation by visual inspection during endoscopy is often difficult and subject to error. The purpose of this study is to develop a quantitative approach that enables an accurate and objective measurement of polyp size and to study the feasibility of the method. METHODS: We attempted to estimate polyp size and location relative to the gastro-oesophageal junction by integrating data from an electromagnetic tracking sensor and endoscopic images. This method is based on estimation of the three-dimensional coordinates of the borders of the polyp by combining the endoscope camera position and the corresponding points along the polyp border in endoscopic images using a computer vision-based algorithm. We evaluated the proposed method using a simulated upper gastrointestinal endoscopy model. RESULTS: The difference between the mean of ten measurements of one artificial polyp and its actual size (10 mm in diameter) was 0.86 mm. Similarly, the difference between the mean of ten measurements of the polyp distance from the gastroesophageal junction and its actual distance (~ 22 cm) was 1.28 mm. Our results show that the changes in camera positions in which the images were taken and the quality of the polyp segmentation have the most impact on the accuracy of polyp size estimation. CONCLUSION: This study demonstrated an innovative approach to endoscopic measurements using motion tracking technologies and computer vision and demonstrated its accuracy in determining the size and location of the polyp. The observed magnitude of error is clinically acceptable, and the measurements are available immediately after the images captured. To enhance accuracy, it is recommended to avoid identical images and instead utilise control wheels on the endoscope for capturing different views. Future work should further evaluate this innovative method during clinical endoscopic procedures.


Assuntos
Pólipos do Colo , Neoplasias Gastrointestinais , Humanos , Endoscopia Gastrointestinal , Endoscópios , Movimento (Física) , Algoritmos , Pólipos do Colo/diagnóstico , Colonoscopia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...