Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Br J Radiol ; 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38648776

RESUMO

OBJECTIVES: A portable respiratory training system with a gyroscope sensor (GRTS) was developed and the feasibility of respiratory training was evaluated. METHODS: Simulated respiratory waveforms from a respiratory motion phantom and actual respirator waveforms from volunteers were acquired using the GRTS and Respiratory Gating for Scanners system (RGSC). Respiratory training was evaluated by comparing the stability and reproducibility of respiratory waveforms from patients undergoing liver stereotactic body radiation therapy, with and without the GRTS. The stability and reproducibility of respiratory waveforms were assessed by root mean square error and gold marker placement-based success rate of expiratory breath-hold, respectively. RESULTS: The absolute mean difference for sinusoidal waveforms between the GRTS and RGSC was 2.1%. Among volunteers, the mean percentages of errors within ±15% of the respiratory waveforms acquired by the GRTS and RGSC were 95.5% for free breathing and 80.7% for expiratory breath-hold. The mean root mean square error and success rate of expiratory breath-hold (standard deviation) with and without the GRTS were 0.65 (0.24) and 0.88 (0.89) cm, and 91.0% (6.9) and 89.1% (11.6), respectively. CONCLUSIONS: Respiratory waveforms acquired by the GRTS exhibit good agreement with waveforms acquired by the RGSC. Respiratory training with the GRTS reduces inter-patient variability in respiratory waveforms, thereby improving the success of expiratory breath-hold liver stereotactic body radiation therapy. ADVANCES IN KNOWLEDGE: A respiratory training system with a gyroscope sensor is inexpensive and portabl, making it ideal for respiratory training. This is the first report concerning clinical implementation of a respiratory training system.

2.
Phys Eng Sci Med ; 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38353926

RESUMO

In linear accelerator-based stereotactic irradiation (STI) for brain metastasis, cone-beam computed tomography (CBCT) image quality is essential for ensuring precise patient setup and tumor localization. However, CBCT images may be degraded by the deviation of the CBCT isocenter from the brain center. This study aims to investigate the effects of the distance from the brain center to the CBCT isocenter (DBI) on the image quality in STI. An anthropomorphic phantom was scanned with varying DBI in right, anterior, superior, and inferior directions. Thirty patients undergoing STI were prospectively recruited. Objective metrics, utilizing regions of interest included contrast-to-noise ratio (CNR) at the centrum semiovale, lateral ventricle, and basal ganglia levels, gray and white matter noise at the basal ganglia level, artifact index (AI), and nonuniformity (NU). Two radiation oncologists assessed subjective metrics. In this phantom study, objective measures indicated a degradation in image quality for non-zero DBI. In this patient study, there were significant correlations between the CNR at the centrum semiovale and lateral ventricle levels (rs = - 0.79 and - 0.77, respectively), gray matter noise (rs = 0.52), AI (rs = 0.72), and NU (rs = 0.91) and DBI. However, no significant correlations were observed between the CNR at the basal ganglia level, white matter noise, and subjective metrics and DBI (rs < ± 0.3). Our results demonstrate the effects of DBI on contrast, noise, artifacts in the posterior fossa, and uniformity of CBCT images in STI. Aligning the CBCT isocenter with the brain center can aid in improving image quality.

3.
J Appl Clin Med Phys ; 24(2): e13836, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36333969

RESUMO

OBJECTIVE: Dosimetric potential of knowledge-based RapidPlan planning model trained with HyperArc plans (Model-HA) for brain metastases has not been reported. We developed a Model-HA and compared its performance with that of clinical volumetric modulated arc therapy (VMAT) plans. METHODS: From 67 clinical stereotactic radiosurgery (SRS) HyperArc plans for brain metastases, 47 plans were used to build and train a Model-HA. The other 20 clinical HyperArc plans were recalculated in RapidPlan system with Model-HA. The model performance was validated with the 20 plans by comparing dosimetric parameters for normal brain tissue between clinical plans and model-generated plans. The 20 clinical conventional VMAT-based SRS or stereotactic radiotherapy plans (CL-VMAT) were reoptimized with Model-HA (RP) and HyperArc system (HA), respectively. The dosimetric parameters were compared among three plans (CL-VMAT vs. RP vs. HA) in terms of planning target volume (PTV), normal brain excluding PTVs (Brain - PTV), brainstem, chiasm, and both optic nerves. RESULTS: In model validation, the optimization performance of Model-HA was comparable to that of HyperArc system. In comparison to CL-VMAT, there were no significant differences among three plans with respect to PTV coverage (p > 0.17) and maximum dose for brainstem, chiasm, and optic nerves (p > 0.40). RP provided significantly lower V20 Gy , V12 Gy , and V4 Gy for Brain - PTV than CL-VMAT (p < 0.01). CONCLUSION: The Model-HA has the potential to significantly reduce the normal brain dose of the original VMAT plans for brain metastases.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/secundário , Encéfalo , Radiocirurgia/métodos , Radioterapia de Intensidade Modulada/métodos
4.
Rep Pract Oncol Radiother ; 27(5): 809-820, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36523803

RESUMO

Background: We evaluated the setup error and dose absorption of an immobilization system with a shell and wooden baseplate (SW) for lung stereotactic body radiotherapy (SBRT). Materials and methods: Setup errors in 109 patients immobilized with an SW or BodyFix system (BF) were compared. Dose attenuation rates of materials for baseplates were measured with an ion-chamber. Ionization measurements were performed from 90° to 180° gantry angle in 10° increments, with the ball water equivalent phantom placed at the center of the wood and carbon baseplates whose effects on dose distribution were compared using an electron portal imaging device. Results: The ratio for the anterior-posterior, cranial-caudal, and right-left of the cases within 3-mm registered shifts in interfractional setup error were 90.9%, 89.2%, and 97.4% for the SW, and 93.2%, 91.6%, and 98.0% for the BF, respectively. For intrafractional setup error, 98.3%, 97.4%, and 99.1% for the SW and 96.6%, 95.8%, and 98.7% for the BF were within 3-mm registered shifts, respectively. In the center position, the average (minimum/maximum) dose attenuation rates from 90° to 180° for the wooden and carbon baseplates were 0.5 (0.1/2.8)% and 1.0 (-0.1/10.1)% with 6 MV, respectively. The gamma passing rates of 2%/2 mm for the wooden and carbon baseplates were 99.7% and 98.3% (p < 0.01). Conclusions: The immobilization system with an SW is effective for lung SBRT since it is comparable to the BF in setup accuracy. Moreover, the wooden baseplate had lower radiation attenuation rates and affected the dose distribution less than the carbon baseplate.

5.
Geroscience ; 44(4): 2305-2318, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35593945

RESUMO

Cognitive function progressively declines with advancing age. The aging process can be promoted by obesity and attenuated by exercise. Both conditions affect levels of the chemokine CX3CL1 in peripheral tissues; however, its role in cognitive aging is unknown. In the current study, we administered CX3CL1 into the peritoneal cavity of aged mice to investigate its impact on the aging process. In the peritoneal cavity, CX3CL1 not only reversed the age-associated accumulation of cells expressing the senescence marker p16INK4a but also increased peritoneal phagocytic activity, indicating that CX3CL1 affected the phenotypes of peritoneal cells. In the hippocampus of aged mice, intraperitoneal administration of CX3CL1 increased the number of Type-2 neural stem cells and promoted brain-derived neurotrophic factor (BDNF) expression. This treatment, furthermore, improved novel object recognition memory impaired with advancing age. Intraperitoneal transplantation of peritoneal cells from CX3CL1-treated aged mice improved novel object recognition memory in recipient aged mice. It indicates that peritoneal cells have a critical role in the CX3CL1-induced improvement of recognition memory in aged mice. Vagotomy inhibited the CX3CL1-induced increase in BDNF expression, demonstrating that the vagus nerve is involved in the hippocampal BDNF expression induced by intraperitoneal administration of CX3CL1. Thus, our results demonstrate that a novel connection among the peritoneal cells, the vagus nerve, and the hippocampus can reverse the age-associated decline in recognition memory.


Assuntos
Fator Neurotrófico Derivado do Encéfalo , Quimiocina CX3CL1 , Animais , Camundongos , Fator Neurotrófico Derivado do Encéfalo/genética , Quimiocina CX3CL1/metabolismo , Reconhecimento Psicológico/fisiologia , Hipocampo/metabolismo , Cognição
6.
Anticancer Res ; 40(12): 6957-6970, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33288590

RESUMO

BACKGROUND/AIM: The aim of this retrospective study was to detect the frequency, reasons, and significant factors for not receiving immunotherapy after chemoradiotherapy in non-small cell lung cancer (NSCLC) patients. PATIENTS AND METHODS: Thirty-four patients with NSCLC received definitive chemoradiotherapy. The endpoint of this study was receiving durvalumab within 45 days after chemoradiotherapy for NSCLC. RESULTS: Twenty-five of 34 (73%) patients received immunotherapy within 45 days after chemoradiotherapy. The reasons for not receiving immunotherapy were radiation pneumonitis (50%), radiation esophagitis (10%), and four other reasons (40%). Univariate analysis showed that significant factors for not receiving immunotherapy were elective nodal irradiation (ENI)+ and chronic obstructive pulmonary disease (COPD)+. The rate of immunotherapy was 100% (17/17 cases) in the COPD- and ENI- group, and 16% (1/6 cases) in the COPD+ and ENI+ group. CONCLUSION: ENI for NSCLC complicated with COPD decreased the rate of immunotherapy after definitive chemoradiotherapy.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/complicações , Carcinoma Pulmonar de Células não Pequenas/terapia , Neoplasias Pulmonares/complicações , Neoplasias Pulmonares/terapia , Metástase Linfática/radioterapia , Doença Pulmonar Obstrutiva Crônica/complicações , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/patologia , Quimiorradioterapia , Terapia Combinada , Feminino , Seguimentos , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Radioterapia Adjuvante/efeitos adversos , Radioterapia Adjuvante/métodos , Resultado do Tratamento
7.
Med Dosim ; 45(1): 85-91, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31378401

RESUMO

We assessed the effect of collimator angle on the dosimetric parameters for targets and organs at risk (OARs) for collimator-optimized HA (CO-HA) and non-CO-HA (nCO-HA) plans. The nCO-HA and CO-HA plans were retrospectively generated for 26 patients (1 to 8 brain metastases). The dosimetric parameters for planning target volume (homogeneity index [HI]; conformity index [CI]; gradient index [GI]) and for OARs were compared. The modulation complexity score for volumetric modulated arc therapy (MCSV) and monitor units (MUs) were calculated. Doses were measured using the electronic portal imaging device and compared with the expected doses. Dosimetric parameters of the HI, CI, and GI for single (n = 12) and multiple (n = 14) metastases cases were comparable (p > 0.05). For multiple metastases cases, the CO-HA plan provided lower V4Gy, V12Gy, V14Gy, V16Gy for brain tissue compared to the nCO-HA plan (p < 0.05). Doses for OARs (D0.1cc) (brainstem, chiasm, Hippocampus, lens, optic nerves, and retinas) were comparable (p > 0.05). For multiple metastases cases, the CO-HA plan resulted in less complex multileaf collimator (MLC) patterns (MCSV = 0.19 ± 0.04, p < 0.01), lower MUs (8596 ± 1390 MUs, p < 0.01), and shorter beam-on time (6.2 ± 1.0 min, p < 0.01) compared to the nCO-HA plan (0.16 ± 0.04, 9365 ± 1630, and 6.7 ± 1.2 for MCSV, MUs, and beam-on time, respectively). For both treatment approach, the equivalent gamma passing rate was obtained with the 3%/3 mm and 2%/2 mm criteria (p > 0.05). The collimator optimization in the HA planning reduced doses to brain tissues and improved the treatment efficacy.


Assuntos
Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundário , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Órgãos em Risco , Radiocirurgia/efeitos adversos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/efeitos adversos , Estudos Retrospectivos
8.
Med Phys ; 47(2): 371-379, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31733105

RESUMO

PURPOSE: The aim of this study was to develop a deep learning (DL) method for generating virtual noncontrast (VNC) computed tomography (CT) images from contrast-enhanced (CE) CT images (VNCDL ) and to evaluate its performance in dose calculations for head and neck radiotherapy in comparison with VNC images derived from a dual-energy CT (DECT) scanner (VNCDECT ). METHODS: This retrospective study included data for 61 patients who underwent head and neck radiotherapy. All planning CT images were obtained with a single-source DECT scanner (80 and 140 kVp) with rapid kVp switching. The DL-based method used a pair of virtual monochromatic images (VMIs) at 70 keV with and without contrast materials. VMIs without contrast materials were used as reference true noncontrast (TNC) images. Deformable image registration was used between the TNC and CE images. We used the data of 45 patients, chosen randomly, for training (7922 paired images), and data from the other 16 patients as test data. We generated the VNCDL images with a densely connected convolutional network. As the VNCDECT images, we used VMIs with the iodine signal suppressed, reconstructed from the CE images of the 16 test patients. The CT numbers of the tumor, common carotid artery, internal jugular vein, muscle, fat, bone marrow, cortical bone, and mandible of each VNC image were compared with those of the TNC image. The dose of the reference TNC plan was recalculated using the CE, VNCDL , and VNCDECT images. Difference maps of the dose distributions and dose-volume histograms were evaluated. RESULTS: The mean prediction time for the VNCDL images was 3.4 s per patient, and the mean number of slices was 204. The absolute differences in CT numbers of the VNCDL images were significantly smaller than those of the VNCDECT images for the bone marrow (8.0 ± 6.5 vs 175.1 ± 40.9 HU; P < 0.001) and mandible (20.3 ± 19.3 vs 106.2 ± 80.5 HU; P = 0.002). The DL-based model provided the dose distribution most similar to that of the TNC plan. With the VNCDECT plans, dose errors >1.0% were observed in bone regions. The dose-volume histogram analysis showed that the VNCDL plans yielded the smallest errors for the primary target, although dose differences were <1.0% for all the approaches. For the maximum dose to the mandible, the mean ± SD errors for the CE, VNCDL , and VNCDECT plans were -0.13% ± 0.23% (range: -0.46% to 0.31%; P = 0.037), -0.01% ± 0.22% (range: -0.40% to 0.36%; P = 1.0), and 0.53% ± 0.47% (range: -0.21% to 1.41%; P < 0.001), respectively. CONCLUSIONS: In this study, we developed a method based on DL that can rapidly generate VNC images from CE images without a DECT scanner. Compared with the DECT approach, the DL-based method improved the prediction accuracy of CT numbers in bone regions. Consequently, there was greater agreement between the VNCDL and TNC plan dose distributions than with the CE and VNCDECT plans, achieved by suppressing the contrast material signals while retaining the CT numbers of bone structures.


Assuntos
Meios de Contraste/química , Aprendizado Profundo , Iodo/química , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X/métodos , Cabeça , Humanos , Pescoço , Intensificação de Imagem Radiográfica , Reprodutibilidade dos Testes , Fatores de Tempo
9.
J Appl Clin Med Phys ; 20(10): 84-91, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31507075

RESUMO

PURPOSE: In stereotactic radiosurgery (SRS) with single-isocentric treatments for brain metastases, rotational setup errors may cause considerable dosimetric effects. We assessed the dosimetric effects on HyperArc plans for single and multiple metastases. METHODS: For 29 patients (1-8 brain metastases), HyperArc plans with a prescription dose of 20-24 Gy for a dose that covers 95% (D95% ) of the planning target volume (PTV) were retrospectively generated (Ref-plan). Subsequently, the computed tomography (CT) used for the Ref-plan and cone-beam CT acquired during treatments (Rot-CT) were registered. The HyperArc plans involving rotational setup errors (Rot-plan) were generated by re-calculating doses based on the Rot-CT. The dosimetric parameters between the two plans were compared. RESULTS: The dosimetric parameters [D99% , D95% , D1% , homogeneity index, and conformity index (CI)] for the single-metastasis cases were comparable (P > 0.05), whereas the D95% for each PTV of the Rot-plan decreased 10.8% on average, and the CI of the Rot-plan was also significantly lower than that of the Ref-plan (Ref-plan vs Rot-plan, 0.93 ± 0.02 vs 0.75 ± 0.14, P < 0.01) for the multiple-metastases cases. In addition, for the multiple-metastases cases, the Rot-plan resulted in significantly higher V10Gy (P = 0.01), V12Gy (P = 0.02), V14Gy (P = 0.02), and V16Gy (P < 0.01) than those in the Ref-plan. CONCLUSION: The rotational setup errors for multiple brain metastases cases caused non-negligible underdosage for PTV and significant increases of V10Gy to V16Gy in SRS with HyperArc.


Assuntos
Neoplasias Encefálicas/secundário , Neoplasias Encefálicas/cirurgia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Erros de Configuração em Radioterapia/prevenção & controle , Radioterapia de Intensidade Modulada/métodos , Humanos , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...