Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 149: 48-51, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31026791

RESUMO

The thermoluminescence material, CaSO4:Dy, is widely used for the dosimetry of ionizing radiation due to its high sensitivity, low fading and wide dose range from µGy to few tens of gray. However, its application is limited at high doses due to non-linear and saturation effects. In this paper, X-ray Absorption Near Edge Structure (XANES) studies at the Dy L3-edge have been carried out on CaSO4:Dy discs exposed to gamma doses in the range 0-1000 Gy. The results show an increase in white line in XANES spectra with gamma dose. Structural change in CaSO4:Dy also has been studied using X-Ray Diffraction (XRD) and has found no structural change up to 1000 Gy. The study indicates that XANES can be used as an alternative dosimetry technique and is useful in the evaluation of absorbed dose in the case of accidental exposure to high radiation in a radiation facility or during a radiological accident.


Assuntos
Raios gama , Radiometria/métodos , Espectroscopia por Absorção de Raios X/métodos , Sulfato de Cálcio/química , Difração de Raios X
2.
Lasers Med Sci ; 32(7): 1535-1544, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28699043

RESUMO

We report the results of a study carried out to investigate the potential of optical techniques such as optical coherence tomography, Mueller matrix spectroscopy, and cross-polarization imaging for noninvasive monitoring of the ionizing radiation exposure-induced alterations in cutaneous tissue of mice. Radiation dose-dependent changes were observed in tissue microvasculature and tissue optical parameters like retardance and depolarization as early as 1 h post radiation exposure. Results suggest that these optical techniques may allow early detection of radiation dose-dependent alterations which could help in screening of population exposed to radiation.


Assuntos
Raios gama , Imagem Óptica/métodos , Pele/patologia , Pele/efeitos da radiação , Animais , Relação Dose-Resposta à Radiação , Orelha , Feminino , Masculino , Camundongos , Microvasos/efeitos da radiação , Radiação Ionizante , Tomografia de Coerência Óptica
3.
Radiat Prot Dosimetry ; 164(3): 187-93, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25209995

RESUMO

Five synchrotron radiation beam lines are commissioned and now under regular operation at the Synchrotron Radiation Source, Indus-2 at Raja Ramanna Centre For Advanced Technology (RRCAT), Indore, India. Nine beam lines are under trial operation, and six beam lines are in the installation stage. In the early phase of installation of beam lines on Indus-2, three bending magnet beam lines, Extended X-ray Absorption Fine Structure (EXAFS, BL-8), Energy Dispersive X-ray Diffraction (EDXRD, BL-11) and Angle Dispersive X-ray Diffraction (ADXRD, BL-12), were installed and commissioned, after approval from Atomic Energy Regulatory Board (AERB), India. These beam lines are pink (BL-8), white (BL-11) and monochromatic (BL-12), which are housed in specially designed shielded hutches. In order to ensure safety of users and other working personnel from ionizing radiations present in these beam lines, several safety systems are incorporated and safety procedures are followed. The paper describes the radiological safety aspects of the three beam lines during its initial commissioning trials and also the measurements on radiation levels carried out in and around the beam line hutches.


Assuntos
Arquitetura de Instituições de Saúde/métodos , Lesões por Radiação/prevenção & controle , Proteção Radiológica/instrumentação , Síncrotrons/instrumentação , Arquitetura de Instituições de Saúde/instrumentação , Humanos , Medição de Risco , Segurança , Difração de Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA