Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
medRxiv ; 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38260571

RESUMO

Background: To create an opportunistic screening strategy by multitask deep learning methods to stratify prediction for coronary artery calcium (CAC) and associated cardiovascular risk with frontal chest x-rays (CXR) and minimal data from electronic health records (EHR). Methods: In this retrospective study, 2,121 patients with available computed tomography (CT) scans and corresponding CXR images were collected internally (Mayo Enterprise) with calculated CAC scores binned into 3 categories (0, 1-99, and 100+) as ground truths for model training. Results from the internal training were tested on multiple external datasets (domestic (EUH) and foreign (VGHTPE)) with significant racial and ethnic differences and classification performance was compared. Findings: Classification performance between 0, 1-99, and 100+ CAC scores performed moderately on both the internal test and external datasets, reaching average f1-score of 0.66 for Mayo, 0.62 for EUH and 0.61 for VGHTPE. For the clinically relevant binary task of 0 vs 400+ CAC classification, the performance of our model on the internal test and external datasets reached an average AUCROC of 0.84. Interpretation: The fusion model trained on CXR performed better (0.84 average AUROC on internal and external dataset) than existing state-of-the-art models on predicting CAC scores only on internal (0.73 AUROC), with robust performance on external datasets. Thus, our proposed model may be used as a robust, first-pass opportunistic screening method for cardiovascular risk from regular chest radiographs. For community use, trained model and the inference code can be downloaded with an academic open-source license from https://github.com/jeong-jasonji/MTL_CAC_classification . Funding: The study was partially supported by National Institute of Health 1R01HL155410-01A1 award.

2.
Heart ; 110(4): 299-305, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-37643771

RESUMO

OBJECTIVES: Lipoprotein(a) (Lp(a)) is associated with an increased incidence of native aortic stenosis, which shares similar pathological mechanisms with bioprosthetic aortic valve (bAV) degeneration. However, evidence regarding the role of Lp(a) concentrations in bAV degeneration is lacking. This study aims to evaluate the association between Lp(a) concentrations and bAV degeneration. METHODS: In this retrospective multicentre study, patients who underwent a bAV replacement between 1 January 2010 and 31 December 2020 and had a Lp(a) measurement were included. Echocardiography follow-up was performed to determine the presence of bioprosthetic valve degeneration, which was defined as an increase >10 mm Hg in mean gradient from baseline with concomitant decrease in effective orifice area and Doppler Velocity Index, or new moderate/severe prosthetic regurgitation. Levels of Lp(a) were compared between patients with and without degeneration and Cox regression analysis was performed to investigate the association between Lp(a) levels and bioprosthetic valve degeneration. RESULTS: In total, 210 cases were included (mean age 74.1±9.4 years, 72.4% males). Median time between baseline and follow-up echocardiography was 4.4 (IQR 3.7) years. Bioprostheses degeneration was observed in 33 (15.7%) patients at follow-up. Median serum levels of Lp(a) were significantly higher in patients affected by degeneration versus non-affected cases: 50.0 (IQR 72.0) vs 15.6 (IQR 48.6) mg/dL, p=0.002. In the regression analysis, high Lp(a) levels (≥30 mg/dL) were associated with degeneration both in a univariable analysis (HR 3.6, 95% CI 1.7 to 7.6, p=0.001) and multivariable analysis adjusted by other risk factors for bioprostheses degeneration (HR 4.4, 95% CI 1.9 to 10.4, p=0.001). CONCLUSIONS: High serum Lp(a) is associated with bAV degeneration. Prospective studies are needed to confirm these findings and to investigate whether lowering Lp(a) levels could slow bioprostheses degradation.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/patologia , Lipoproteína(a) , Estenose da Valva Aórtica/complicações , Ecocardiografia , Insuficiência da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Bioprótese/efeitos adversos , Resultado do Tratamento
3.
J Cardiovasc Dev Dis ; 10(1)2022 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-36661896

RESUMO

BACKGROUND: Prior studies have reported conflicting results of persistent iatrogenic atrial septal defect (iASD) and its impact following a transcatheter edge-to-edge repair (TEER) procedure. This study aims to evaluate the incidence of iASD and its clinical and hemodynamic impact after a TEER. METHODS: Consecutive patients who underwent a TEER procedure from June 2014 to September 2020 at the Mayo Clinic were identified. The presence of iASD was retrospectively identified on post-procedure transthoracic echocardiography (TTE) to group patients into an iASD+ group and an iASD- group for comparison of prognosis and cardiac function. RESULTS: A total of 316 patients were included; the mean age was 79.1 ± 9.1 years, and 67.7% were male. Persistent iASD was diagnosed in 108 (34.2%) patients. There was no difference concerning all-cause mortality, heart failure hospitalization, and stroke/TIA between groups at follow-up (median follow-up of 9 months). Post-procedure TTE demonstrated no differences regarding right ventricle (RV) and left ventricle (LV) dimensions and function, including TAPSE (15.2 ± 4.6 vs. 15.4 ± 5.5 mm, p = 0.875), and LV ejection fraction (51.1 ± 14.0% vs. 51.3 ± 13.9%, p = 0.933). However, patients with iASD had higher RV systolic pressure (48.7 ± 14.4 vs. 45.5 ± 14.5 mmHg, p = 0.042) compared with patients without iASD. CONCLUSION: Notwithstanding higher RV pressures, patients with persistent iASD had no hemodynamic compromise and an equal prognosis compared with those without a residual atrial defect after a TEER procedure. These findings support the mid-term safety of procedures in which an interatrial defect needs to be created and would argue against the need for interventional closure.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...