1.
Phys Med Biol ; 69(3)2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-38091616

RESUMO

Objective. In this multicentric collaborative study, we aimed to verify whether the selected radiation detectors satisfy the requirements of TRS-483 Code of Practice for relative small field dosimetry in megavoltage photon beams used in radiotherapy, by investigating four dosimetric characteristics. Furthermore, we intended to analyze and complement the recommendations given in TRS-483.Approach. Short-term stability, dose linearity, dose-rate dependence, and leakage were determined for 17 models of detectors considered suitable for small field dosimetry. Altogether, 47 detectors were used in this study across ten institutions. Photon beams with 6 and 10 MV, with and without flattening filters, generated by Elekta Versa HDTMor Varian TrueBeamTMlinear accelerators, were used.Main results. The tolerance level of 0.1% for stability was fulfilled by 70% of the data points. For the determination of dose linearity, two methods were considered. Results from the use of a stricter method show that the guideline of 0.1% for dose linearity is not attainable for most of the detectors used in the study. Following the second approach (squared Pearson's correlation coefficientr2), it was found that 100% of the data fulfill the criteriar2> 0.999 (0.1% guideline for tolerance). Less than 50% of all data points satisfied the published tolerance of 0.1% for dose-rate dependence. Almost all data points (98.2%) satisfied the 0.1% criterion for leakage.Significance. For short-term stability (repeatability), it was found that the 0.1% guideline could not be met. Therefore, a less rigorous criterion of 0.25% is proposed. For dose linearity, our recommendation is to adopt a simple and clear methodology and to define an achievable tolerance based on the experimental data. For dose-rate dependence, a realistic criterion of 1% is proposed instead of the present 0.1%. Agreement was found with published guidelines for background signal (leakage).


Assuntos
Aceleradores de Partículas , Radiometria , Radiometria/métodos , Fótons
2.
Cell Death Discov ; 9(1): 252, 2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37460469

RESUMO

Cellular senescence is involved in the development of pulmonary fibrosis as well as in lung tissue repair and regeneration. Therefore, a strategy of removal of senescent cells by senolytic drugs may not produce the desired therapeutic result. Previously we reported that tyrosine kinase Fgr is upregulated in ionizing irradiation-induced senescent cells. Inhibition of Fgr reduces the production of profibrotic proteins by radiation-induced senescent cells in vitro; however, a mechanistic relationship between senescent cells and radiation-induced pulmonary fibrosis (RIPF) has not been established. We now report that senescent cells from the lungs of mice with RIPF, release profibrotic proteins for target cells and secrete chemotactic proteins for marrow cells. The Fgr inhibitor TL02-59, reduces this release of profibrotic chemokines from the lungs of RIPF mice, without reducing numbers of senescent cells. In vitro studies demonstrated that TL02-59 abrogates the upregulation of profibrotic genes in target cells in transwell cultures. Also, protein arrays using lung fibroblasts demonstrated that TL02-59 inhibits the production of chemokines involved in the migration of macrophages to the lung. In thoracic-irradiated mice, TL02-59 prevents RIPF, significantly reduces levels of expression of fibrotic gene products, and significantly reduces the recruitment of CD11b+ macrophages to the lungs. Bronchoalveolar lavage (BAL) cells from RIPF mice show increased Fgr and other senescent cell markers including p16. In human idiopathic pulmonary fibrosis (IPF) and in RIPF, Fgr, and other senescent cell biomarkers are increased. In both mouse and human RIPF, there is an accumulation of Fgr-positive proinflammatory CD11b+ macrophages in the lungs. Thus, elevated levels of Fgr in lung senescent cells upregulate profibrotic gene products, and chemokines that might be responsible for macrophage infiltration into lungs. The detection of Fgr in senescent cells that are obtained from BAL during the development of RIPF may help predict the onset and facilitate the delivery of medical countermeasures.

3.
Radiat Res ; 198(1): 89-105, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35446961

RESUMO

Oral administration (gavage) of a second-generation probiotic, Lactobacillus reuteri (L. reuteri), that releases interleukin-22 (LR-IL-22) at 24 h after total-body irradiation (TBI) mitigates damage to the intestine. We determined that LR-IL-22 also mitigates partial-body irradiation (PBI) and whole-abdomen irradiation (WAI). Irradiation can be an effective treatment for ovarian cancer, but its use is limited by intestinal toxicity. Strategies to mitigate toxicity are important and can revitalize this modality to treat ovarian cancer. In the present studies, we evaluated whether LR-IL-22 facilitates fractionated WAI in female C57BL/6 mice with disseminated ovarian cancer given a single fraction of either 15.75 Gy or 19.75 Gy or 4 daily fractions of 6 Gy or 6.5 Gy. Mice receiving single or multiple administrations of LR-IL-22 during WAI showed improved intestinal barrier integrity (P = 0.0167), reduced levels of radiation-induced intestinal cytokines including KC/CXCL1 (P = 0.002) and IFN-γ (P = 0.0024), and reduced levels of plasma, Eotaxin/CCL11 (P = 0.0088). LR-IL-22 significantly preserved the numbers of Lgr5+GFP+ intestinal stem cells (P = 0.0010) and improved survival (P < 0.0343). Female C57BL/6MUC-1 mice with widespread abdominal syngeneic 2F8cis ovarian cancer that received LR-IL-22 during 6.5 Gy WAI in 4 fractions had reduced tumor burden, less intestinal toxicity, and improved 30-day survival. Furthermore, LR-IL-22 facilitated WAI when added to Paclitaxel and Carboplatin chemotherapy and further increased survival. Oral administration (gavage) of LR-IL-22 is a potentially valuable intestinal radioprotector, which can facilitate therapeutic WAI for widespread intra-abdominal ovarian cancer.


Assuntos
Limosilactobacillus reuteri , Neoplasias Ovarianas , Abdome , Animais , Carcinoma Epitelial do Ovário , Feminino , Humanos , Interleucinas , Intestinos/patologia , Camundongos , Camundongos Endogâmicos C57BL , Neoplasias Ovarianas/patologia , Neoplasias Ovarianas/radioterapia , Interleucina 22
4.
Cell Death Discov ; 7(1): 349, 2021 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-34772919

RESUMO

The role of cellular senescence in radiation-induced pulmonary fibrosis (RIPF) and the underlying mechanisms are unknown. We isolated radiation-induced senescent tdTOMp16 positive mesenchymal stem cells, established their absence of cell division, then measured levels of irradiation-induced expression of biomarkers of senescence by RNA-seq analysis. We identified a Log2 6.17-fold upregulation of tyrosine kinase Fgr, which was a potent inducer of biomarkers of fibrosis in target cells in non-contact co-cultures. Inhibition of Fgr by shRNA knockdown did not block radiation-induced senescence in vitro; however, both shRNA knockdown, or addition of a specific small-molecule inhibitor of Fgr, TL02-59, abrogated senescent cell induction of profibrotic genes in transwell-separated target cells. Single-cell RNA-seq (scRNAseq) analysis of mouse lungs at day 150 after 20 Gy thoracic irradiation revealed upregulation of Fgr in senescent neutrophils, and macrophages before detection of lung fibrosis. Thus, upregulated Fgr in radiation-induced senescent cells mediates RIPF and is a potential therapeutic target for the prevention of this radiation late effect.

5.
Med Phys ; 48(10): e886-e921, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34101836

RESUMO

Small-field dosimetry used in advance treatment technologies poses challenges due to loss of lateral charged particle equilibrium (LCPE), occlusion of the primary photon source, and the limited choice of suitable radiation detectors. These challenges greatly influence dosimetric accuracy. Many high-profile radiation incidents have demonstrated a poor understanding of appropriate methodology for small-field dosimetry. These incidents are a cause for concern because the use of small fields in various specialized radiation treatment techniques continues to grow rapidly. Reference and relative dosimetry in small and composite fields are the subject of the International Atomic Energy Agency (IAEA) dosimetry code of practice that has been published as TRS-483 and an AAPM summary publication (IAEA TRS 483; Dosimetry of small static fields used in external beam radiotherapy: An IAEA/AAPM International Code of Practice for reference and relative dose determination, Technical Report Series No. 483; Palmans et al., Med Phys 45(11):e1123, 2018). The charge of AAPM task group 155 (TG-155) is to summarize current knowledge on small-field dosimetry and to provide recommendations of best practices for relative dose determination in small megavoltage photon beams. An overview of the issue of LCPE and the changes in photon beam perturbations with decreasing field size is provided. Recommendations are included on appropriate detector systems and measurement methodologies. Existing published data on dosimetric parameters in small photon fields (e.g., percentage depth dose, tissue phantom ratio/tissue maximum ratio, off-axis ratios, and field output factors) together with the necessary perturbation corrections for various detectors are reviewed. A discussion on errors and an uncertainty analysis in measurements is provided. The design of beam models in treatment planning systems to simulate small fields necessitates special attention on the influence of the primary beam source and collimating devices in the computation of energy fluence and dose. The general requirements for fluence and dose calculation engines suitable for modeling dose in small fields are reviewed. Implementations in commercial treatment planning systems vary widely, and the aims of this report are to provide insight for the medical physicist and guidance to developers of beams models for radiotherapy treatment planning systems.


Assuntos
Fótons , Radiometria , Agências Internacionais , Imagens de Fantasmas
6.
Med Phys ; 47(1): 242-259, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31677278

RESUMO

PURPOSE: The goal of the present work was to provide a large set of detector-specific output correction factors for seven small volume ionization chambers on two linear accelerators in four megavoltage photon beams utilizing perpendicular and parallel orientation of ionization chambers in the beam for nominal field sizes ranging from 0.5 cm2  × 0.5 cm2 to 10 cm2  × 10 cm2 . The present study is the second part of an extensive research conducted by our group. METHODS: Output correction factors k Q clin , Q ref f clin , f ref were experimentally determined on two linacs, Elekta Versa HD and Varian TrueBeam for 6 and 10 MV beams with and without flattening filter for nine square fields ranging from 0.5 cm2  × 0.5 cm2 to 10 cm2  × 10 cm2 , for seven mini and micro ionization chambers, IBA CC04, IBA Razor, PTW 31016 3D PinPoint, PTW 31021 3D Semiflex, PTW 31022 3D PinPoint, PTW 31023 PinPoint, and SI Exradin A16. An Exradin W1 plastic scintillator and EBT3 radiochromic films were used as the reference detectors. RESULTS: For all ionization chambers, values of output correction factors k Q clin , Q ref f clin , f ref were lower for parallel orientation compared to those obtained in the perpendicular orientation. Five ionization chambers from our study set, IBA Razor, PTW 31016 3D PinPoint, PTW 31022 3D PinPoint, PTW 31023 PinPoint, and SI Exradin A16, fulfill the requirement recommended in the TRS-483 Code of Practice, that is, 0.95 < k Q clin , Q ref f clin , f ref < 1.05 , down to the field size 0.8 cm2  × 0.8 cm2 , when they are positioned in parallel orientation; two of the ionization chambers, IBA Razor and PTW 31023 PinPoint, satisfy this condition down to the field size of 0.5 cm2  × 0.5 cm2 . CONCLUSIONS: The present paper provides experimental results of detector-specific output correction factors for seven small volume ionization chambers. Output correction factors were determined in 6 and 10 MV photon beams with and without flattening filter down to the square field size of 0.5 cm2  × 0.5 cm2 for two orientations of ionization chambers - perpendicular and parallel. Our main finding is that output correction factors are smaller if they are determined in a parallel orientation compared to those obtained in a perpendicular orientation for all ionization chambers regardless of the photon beam energy, filtration, or linear accelerator being used. Based on our findings, we recommend using ionization chambers in parallel orientation, to minimize corrections in the experimental determination of field output factors. Latter holds even for field sizes below 1.0 cm2  × 1.0 cm2 , whenever necessary corrections remain within 5%, which was the case for several ionization chambers from our set. TRS-483 recommended perpendicular orientation of ionization chambers for the determination of field output factors. The present study presents results for both perpendicular and parallel orientation of ionization chambers. When validated by other researchers, the present results for parallel orientation can be considered as a complementary dataset to those given in TRS-483.


Assuntos
Fótons , Radiometria/instrumentação , Incerteza
7.
Radiat Oncol ; 13(1): 44, 2018 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-29548340

RESUMO

BACKGROUND: Clinical pathways outline criteria for dose homogeneity and critical organ dosimetry. Based upon an internal audit showing suboptimal compliance with dosimetric parameters in whole breast irradiation (WBI), we conducted a mandatory web-based teaching conference for the network. This study reports the impact of this initiative on subsequent treatment plans. METHODS: Radiation treatment plans were collected for the 10 most recent patients receiving WBI at 16 institutions within the UPMC Hillman Cancer Center network. Subsequently, a web-based conference was conducted to educate staff physicians, physicists, and dosimetrists with goals for dose homogeneity and critical organ dosimetry. Six months post-conference, another 10 plans were collected from each site and compared to pre-conference plans for deviations from dosimetric criteria. RESULTS: Dose homogeneity significantly improved after the conference with breast V105% decreasing from 15.6% to 11.2% (p = 0.004) and breast V110% decreasing from 1.3% to 0.04% (p = 0.008). A higher percentage of cases were compliant with dosimetric criteria, with breast V105% > 20% decreasing from 22.5% to 7.5% of cases (p = 0.0002) and breast V110% > 0% decreasing from 13.8% to 4.4% of cases (p = 0.003). CONCLUSIONS: Implementation of a web-based teaching conference helped improve adherence to clinical pathway dosimetric guidelines for WBI. In radiation oncology networks, this may be an effective model to ensure quality in routine practice and can be extrapolated to other disease sites.


Assuntos
Neoplasias da Mama/radioterapia , Fidelidade a Diretrizes , Internet , Radioterapia (Especialidade)/educação , Feminino , Humanos , Qualidade da Assistência à Saúde , Planejamento da Radioterapia Assistida por Computador
8.
J Appl Clin Med Phys ; 18(5): 195-209, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28834214

RESUMO

PURPOSE: The main aim of this study is to validate the Acuros XB dose calculation algorithm for a Varian Clinac iX linac in our clinics, and subsequently compare it with the wildely used AAA algorithm. METHODS AND MATERIALS: The source models for both Acuros XB and AAA were configured by importing the same measured beam data into Eclipse treatment planning system. Both algorithms were validated by comparing calculated dose with measured dose on a homogeneous water phantom for field sizes ranging from 6 cm × 6 cm to 40 cm × 40 cm. Central axis and off-axis points with different depths were chosen for the comparison. In addition, the accuracy of Acuros was evaluated for wedge fields with wedge angles from 15 to 60°. Similarly, variable field sizes for an inhomogeneous phantom were chosen to validate the Acuros algorithm. In addition, doses calculated by Acuros and AAA at the center of lung equivalent tissue from three different VMAT plans were compared to the ion chamber measured doses in QUASAR phantom, and the calculated dose distributions by the two algorithms and their differences on patients were compared. Computation time on VMAT plans was also evaluated for Acuros and AAA. Differences between dose-to-water (calculated by AAA and Acuros XB) and dose-to-medium (calculated by Acuros XB) on patient plans were compared and evaluated. RESULTS: For open 6 MV photon beams on the homogeneous water phantom, both Acuros XB and AAA calculations were within 1% of measurements. For 23 MV photon beams, the calculated doses were within 1.5% of measured doses for Acuros XB and 2% for AAA. Testing on the inhomogeneous phantom demonstrated that AAA overestimated doses by up to 8.96% at a point close to lung/solid water interface, while Acuros XB reduced that to 1.64%. The test on QUASAR phantom showed that Acuros achieved better agreement in lung equivalent tissue while AAA underestimated dose for all VMAT plans by up to 2.7%. Acuros XB computation time was about three times faster than AAA for VMAT plans, and computation time for other plans will be discussed at the end. Maximum difference between dose calculated by AAA and dose-to-medium by Acuros XB (Acuros_Dm,m ) was 4.3% on patient plans at the isocenter, and maximum difference between D100 calculated by AAA and by Acuros_Dm,m was 11.3%. When calculating the maximum dose to spinal cord on patient plans, differences between dose calculated by AAA and Acuros_Dm,m were more than 3%. CONCLUSION: Compared with AAA, Acuros XB improves accuracy in the presence of inhomogeneity, and also significantly reduces computation time for VMAT plans. Dose differences between AAA and Acuros_Dw,m were generally less than the dose differences between AAA and Acuros_Dm,m . Clinical practitioners should consider making Acuros XB available in clinics, however, further investigation and clarification is needed about which dose reporting mode (dose-to-water or dose-to-medium) should be used in clinics.


Assuntos
Algoritmos , Imagens de Fantasmas , Dosagem Radioterapêutica , Humanos , Aceleradores de Partículas , Fótons , Radiometria , Planejamento da Radioterapia Assistida por Computador
9.
Med Phys ; 43(1): 171, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26745909

RESUMO

PURPOSE: The goal of this study was to evaluate the safety and quality management program for stereotactic radiosurgery (SRS) treatment processes at three radiotherapy centers in Brazil by using three industrial engineering tools (1) process mapping, (2) failure modes and effects analysis (FMEA), and (3) fault tree analysis. METHODS: The recommendations of Task Group 100 of American Association of Physicists in Medicine were followed to apply the three tools described above to create a process tree for SRS procedure for each radiotherapy center and then FMEA was performed. Failure modes were identified for all process steps and values of risk priority number (RPN) were calculated from O, S, and D (RPN = O × S × D) values assigned by a professional team responsible for patient care. RESULTS: The subprocess treatment planning was presented with the highest number of failure modes for all centers. The total number of failure modes were 135, 104, and 131 for centers I, II, and III, respectively. The highest RPN value for each center is as follows: center I (204), center II (372), and center III (370). Failure modes with RPN ≥ 100: center I (22), center II (115), and center III (110). Failure modes characterized by S ≥ 7, represented 68% of the failure modes for center III, 62% for center II, and 45% for center I. Failure modes with RPNs values ≥100 and S ≥ 7, D ≥ 5, and O ≥ 5 were considered as high priority in this study. CONCLUSIONS: The results of the present study show that the safety risk profiles for the same stereotactic radiotherapy process are different at three radiotherapy centers in Brazil. Although this is the same treatment process, this present study showed that the risk priority is different and it will lead to implementation of different safety interventions among the centers. Therefore, the current practice of applying universal device-centric QA is not adequate to address all possible failures in clinical processes at different radiotherapy centers. Integrated approaches to device-centric and process specific quality management program specific to each radiotherapy center are the key to a safe quality management program.


Assuntos
Análise do Modo e do Efeito de Falhas na Assistência à Saúde , Neoplasias/cirurgia , Radiocirurgia/efeitos adversos , Radiocirurgia/estatística & dados numéricos , Brasil , Humanos , Segurança
10.
Med Dosim ; 40(1): 3-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25645205

RESUMO

In linac-based stereotactic radiosurgery (SRS) and radiotherapy (SRT), circular cone(s) or conformal arc(s) are conventionally used to treat intracranial lesions. However, when the target is in close proximity to critical structures, it is frequently quite challenging to generate a quality plan using these techniques. In this study, we investigated the dosimetric characteristics of using high-dose rate RapidArc (RA) technique for radiosurgical treatment of intracranial lesions. A total of 10 intracranial SRS/SRT cases previously planned using dynamic conformal arc (DCA) or cone-based techniques have been included in this study. For each case, 3 treatment plans were generated: (1) a DCA plan with multiple noncoplanar arcs, (2) a high-dose rate RA plan with arcs oriented the same as DCA (multiple-arc RA), and 3) a high-dose rate RA plan with a single coplanar arc (single-arc RA). All treatment plans were generated under the same prescription and similar critical structure dose limits. Plan quality for different plans was evaluated by comparing various dosimetric parameters such as target coverage, conformity index (CI), homogeneity index (HI), critical structures, and normal brain tissue doses as well as beam delivery time. With similar critical structure sparing, high-dose rate RA plans can achieve much better target coverage, dose conformity, and dose homogeneity than the DCA plans can. Plan quality indices CI and HI, for the DCA, multiple-arc RA, and single-arc RA techniques, were measured as 1.67 ± 0.39, 1.32 ± 0.28, and 1.38 ± 0.30 and 1.24 ± 0.11, 1.10 ± 0.04, and 1.12 ± 0.07, respectively. Normal brain tissue dose (V12Gy) was found to be similar for DCA and multiple-arc RA plans but much larger for the single-arc RA plans. Beam delivery was similar for DCA and multiple-arc RA plans but shorter with single-arc RA plans. Multiple-arc RA SRS/SRT can provide better treatment plans than conventional DCA plans, especially for complex cases.


Assuntos
Lesões Encefálicas/prevenção & controle , Neoplasias Encefálicas/cirurgia , Lesões por Radiação/prevenção & controle , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Lesões Encefálicas/etiologia , Neoplasias Encefálicas/diagnóstico , Irradiação Craniana/efeitos adversos , Irradiação Craniana/métodos , Fracionamento da Dose de Radiação , Humanos , Tratamentos com Preservação do Órgão/métodos , Lesões por Radiação/etiologia , Radiometria , Radiocirurgia/efeitos adversos , Radioterapia de Intensidade Modulada/efeitos adversos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento
11.
Med Dosim ; 38(2): 125-32, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23266161

RESUMO

The purpose of this work is to investigate the dosimetric influence of the residual rotational setup errors on head and neck carcinoma (HNC) intensity-modulated radiation therapy (IMRT) with routine 3 translational setup corrections and the adequacy of this routine correction. A total of 66 kV cone beam computed tomography (CBCT) image sets were acquired on the first day of treatment and weekly thereafter for 10 patients with HNC and were registered with the corresponding planning CT images, using 2 3-dimensional (3D) rigid registration methods. Method 1 determines the translational setup errors only, and method 2 determines 6-degree (6D) setup errors, i.e., both rotational and translational setup errors. The 6D setup errors determined by method 2 were simulated in the treatment planning system and were then corrected using the corresponding translational data determined by method 1. For each patient, dose distributions for 6 to 7 fractions with various setup uncertainties were generated, and a plan sum was created to determine the total dose distribution through an entire course and was compared with the original treatment plan. The average rotational setup errors were 0.7°± 1.0°, 0.1°±1.9°, and 0.3°±0.7° around left-right (LR), anterior-posterior (AP), and superior-inferior (SI) axes, respectively. With translational corrections determined by method 1 alone, the dose deviation could be large from fraction to fraction. For a certain fraction, the decrease in prescription dose coverage (Vp) and the dose that covers 95% of target volume (D95) could be up to 15.8% and 13.2% for planning target volume (PTV), and the decrease in Vp and the dose that covers 98% of target volume (D98) could be up to 9.8% and 5.5% for the clinical target volume (CTV). However, for the entire treatment course, for PTV, the plan sum showed that the average Vp was decreased by 4.2% and D95 was decreased by 1.2 Gy for the first phase of IMRT with a prescription dose of 50 Gy. For CTV, the plan sum showed that the average Vp was decreased by 0.8% and D98, relative to prescription dose, was not decreased. Among these 10 patients, the plan sum showed that the dose to 1-cm(3) spinal cord (D(1 cm(3))) increased no more than 1 Gy for 7 patients and more than 2 Gy for 2 patients. The average increase in D(1 cm(3)) was 1.2 Gy. The study shows that, with translational setup error correction, the overall CTV Vp has a minor decrease with a 5-mm margin from CTV to PTV. For the spinal cord, a noticeable dose increase was observed for some patients. So to decide whether the routine clinical translational setup error correction is adequate for this HNC IMRT technique, the dosimetric influence of rotational setup errors should be evaluated carefully from case to case when organs at risk are in close proximity to the target.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Lesões por Radiação/prevenção & controle , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Erros de Configuração em Radioterapia/prevenção & controle , Radioterapia Conformacional/métodos , Neoplasias de Cabeça e Pescoço/complicações , Humanos , Lesões por Radiação/etiologia , Dosagem Radioterapêutica , Radioterapia Conformacional/efeitos adversos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Hum Reprod ; 26(8): 1945-54, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21613315

RESUMO

BACKGROUND: Although infertility is a serious concern in survivors of pediatric cancers, little is known about the influence of the degree of sexual maturation at the time of irradiation on spermatogenic recovery after treatment. Thus, we address this question in a non-human primate model, the rhesus monkey (Macaca mulatta). METHODS: Two pubertal (testis size 3 and 6.5 ml, no sperm in ejaculate) and four prepubertal (testis size 1 ml, no sperm in ejaculate) macaques were submitted to a single fraction of testicular irradiation (10 Gy). Unilateral autologous transfer of cryopreserved testis cells was performed 2 months after irradiation. Testicular volume, histology and semen parameters were analyzed to assess irradiation effects and testicular recovery. RESULTS: Irradiation provoked acute testis involution only in the two pubertal monkeys. Subsequently, testis sizes recovered and sperm was present in the ejaculates. Longitudinal outgrowth of seminiferous tubules continued, and, in testes without autologous cell transfer, 4-22% of tubular cross sections showed spermatogenesis 2 years after irradiation. In contrast, the four prepubertal monkeys showed neither a detectable involution as direct response to irradiation, nor a detectable growth of seminiferous tubules later. However, two of these animals showed spermarche 2 years after irradiation, and 8-12% of tubules presented spermatogenesis. One prepubertally irradiated monkey presented fast growth of one testis after cell transfer, and showed spermarche 1 year after irradiation. The infused testis had spermatogenesis in 70% of the tubules. The contralateral testis remained smaller. CONCLUSION: We conclude that irradiation before puberty has a severe detrimental effect on outgrowth of seminiferous tubules. But, within the seminiferous epithelium, spermatogenetic recovery occurs at a low rate with no detectable relation to the maturity of the epithelium at irradiation. We also show that autologous testis cell transplantation can enhance spermatogenesis, but only in isolated cases.


Assuntos
Células Germinativas/transplante , Túbulos Seminíferos/crescimento & desenvolvimento , Espermatogênese/efeitos da radiação , Testículo/efeitos da radiação , Animais , Macaca mulatta , Masculino , Puberdade , Túbulos Seminíferos/efeitos da radiação , Maturidade Sexual , Espermatogênese/fisiologia , Testículo/anatomia & histologia , Testículo/fisiologia
13.
Biomed Imaging Interv J ; 3(1): e40, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21614265

RESUMO

Respiratory-gated treatment techniques have been introduced into the radiation oncology practice to manage target or organ motions. This paper will review the implementation of this type of gated treatment technique where the respiratory cycle is determined using an external marker. The external marker device is placed on the abdominal region between the xyphoid process and the umbilicus of the patient. An infrared camera tracks the motion of the marker to generate a surrogate for the respiratory cycle. The relationship, if any, between the respiratory cycle and the movement of the target can be complex. The four-dimensional computed tomography (4DCT) scanner is used to identify this motion for those patients that meet three requirements for the successful implementation of respiratory-gated treatment technique for radiation therapy. These requirements are (a) the respiratory cycle must be periodic and maintained during treatment, (b) the movement of the target must be related to the respiratory cycle, and (c) the gating window can be set sufficiently large to minimise the overall treatment time or increase the duty cycle and yet small enough to be within the gate. If the respiratory-gated treatment technique is employed, the end-expiration image set is typically used for treatment planning purposes because this image set represents the phase of the respiratory cycle where the anatomical movement is often the least for the longest time. Contouring should account for tumour residual motion, setup uncertainty, and also allow for deviation from the expected respiratory cycle during treatment. Respiratory-gated intensity-modulated radiation therapy (IMRT) treatment plans must also be validated prior to treatment. Quality assurance should be performed to check for positional changes and the output in association with the motion-gated technique. To avoid potential treatment errors, radiation therapist (radiographer) should be regularly in-serviced and made aware of the need to invoke the gating feature when prescribed for selected patients.

14.
Hematol Oncol Clin North Am ; 20(1): 25-43, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16580555

RESUMO

Therapeutic radiological physics is the branch of physics as applied to radiation therapy. Therapeutic radiological physics involves the understanding of the radiation sources, types, and characteristics of radiation, interaction of radiation with matter, and thereafter the deposition of energy in matter. In clinical practice, therapeutic radiological physics deals with the technical tasks of preparing a patient to undergo radiation therapy. These tasks include simulation, patient data acquisition, individualized planning, verification, and dose delivery. The role of a therapeutic radiological physicist is to manage the technical aspects of patient care: providing technical expertise to the development of the institution, recommending and introducing new treatment techniques, and ensuring that all patients undergoing radiation therapy receive the best standard of care.


Assuntos
Física Médica , Planejamento da Radioterapia Assistida por Computador , Física Médica/instrumentação , Física Médica/métodos , Física Médica/normas , Física Médica/tendências , Humanos , Planejamento da Radioterapia Assistida por Computador/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Planejamento da Radioterapia Assistida por Computador/tendências , Tecnologia Radiológica/instrumentação , Tecnologia Radiológica/métodos , Tecnologia Radiológica/normas , Tecnologia Radiológica/tendências
15.
Phys Med Biol ; 47(20): 3643-9, 2002 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-12433125

RESUMO

This paper presents the results of measurements of output factors (OFs) for a model U Gamma Knife collimator, with special emphasis on the accurate determination of the OF for the 4 mm collimator (OF4). In the past, the OF4 was set to 0.800 relative to the 18 mm collimator. Recently, the manufacturer has recommended a new value of 0.870 for OF4. However, most centres still use the old value of the OF4. In the present study, the Gamma Knife OFs were measured using a commercially available miniature diamond detector and a miniature 0.006 cc ion chamber, which was especially designed for the task. The measured OF4 were corrected for spatial averaging effects by measuring dose profiles for the 4 mm collimator with the same detectors and deconvolving their response from the measured profiles. A Gaussian kernel was used to describe the detector response. The relative OFs measured with the diamond detector/ion chamber were 0.986/0.982, 0.953/0.935 and 0.812/0.765 for the 14,8 and 4 mm collimators, respectively, as compared with the manufacturer's values of 0.984, 0.956 and 0.87. The corrected OF4 was 0.881 +/- 0.012 for the diamond detector and 0.851 +/- 0.012 for the ion chamber, supporting the manufacturer's revised value for this collimator.


Assuntos
Análise de Falha de Equipamento/instrumentação , Radiometria/instrumentação , Radiometria/métodos , Radiocirurgia/instrumentação , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/instrumentação , Calibragem , Análise de Falha de Equipamento/métodos , Controle de Qualidade , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Sensibilidade e Especificidade
16.
Med Phys ; 28(10): 2077-87, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11695769

RESUMO

A comparison of the determination of absorbed dose to water in reference conditions with high-energy electron beams (Enominal of 6, 8, 10, 12, 15, and 18 MeV) following the recommendations given in the AAPM TG-51 and in the original TG-21 dosimetry protocols has been made. Six different ionization chamber types have been used, two Farmer-type cylindrical (PTW 30001, PMMA wall; NE 2571, graphite wall) and four plane parallel (PTW Markus, and Scanditronix-Wellhöfer NACP, PPC-05 and Roos PPC-40). Depending upon the cylindrical chamber type used and the beam energy, the doses at dmax determined with TG-51 were higher than with TG-21 by about 1%-3%. Approximately 1% of this difference is due to the differences in the data given in the two protocols; another 1.1%-1.2% difference is due to the change of standards, from air-kerma to absorbed dose to water. For plane-parallel chambers, absorbed doses were determined by using two chamber calibration methods: (i) direct use of the ADCL calibration factors N(60Co)D,w and Nx for each chamber type in the appropriate equations for dose determination recommended by each protocol, and (ii) cross-calibration techniques in a high-energy electron beam, as recommended by TG-21, TG-39, and TG-51. Depending upon the plane-parallel chamber type used and the beam energy, the doses at dmax determined with TG-51 were higher than with TG-21 by about 0.7%-2.9% for the direct calibration procedures and by 0.8%-3.2% for the cross-calibration techniques. Measured values of photon-electron conversion kecal, for the NACP and Markus chambers were found to be 0.3% higher and 1.7% lower than the corresponding values given in TG-51. For the PPC-05 and PPC-40 (Roos) chamber types, the values of kecal were measured to be 0.889 and 0.893, respectively. The uncertainty for the entire calibration chain, starting from the calibration of the ionization chamber in the standards laboratory to the determination of absorbed dose to water in the user beam, has been analyzed for the two formalisms. For cylindrical chambers, the observed differences between the two protocols are within the estimated combined uncertainty of the ratios of absorbed doses for 6 and 8 MeV; however, at higher energies (10< or =E< or =18 MeV), the differences are larger than the estimated combined uncertainties by about 1%. For plane-parallel chambers, the observed differences are within the estimated combined uncertainties for the direct calibration technique; for the cross-calibration technique the differences are within the uncertainty estimates at low energies whereas they are comparable to the uncertainty estimates at higher energies. A detailed analysis of the reasons for the discrepancies is made which includes comparing the formalisms, correction factors, and quantities in the two protocols, as well as the influence of the implementation of the different standards for chamber calibration.


Assuntos
Elétrons , Radiometria/métodos , Radiometria/normas , Radioterapia de Alta Energia/instrumentação , Radioterapia de Alta Energia/métodos , Fenômenos Biofísicos , Biofísica , Protocolos Clínicos , Humanos , Modelos Estatísticos , Radioterapia de Alta Energia/normas , Água
17.
Med Phys ; 28(1): 46-54, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11213922

RESUMO

Task Group 51 (TG-51) of the Radiation Therapy Committee of the American Association of Physicists in Medicine (AAPM) has recently developed a new protocol for the calibration of high-energy photon and electron beams used in radiation therapy. The formalism and the dosimetry procedures recommended in this protocol are based on the use of an ionization chamber calibrated in terms of absorbed dose-to-water in a standards laboratory's 60Co gamma ray beam. This is different from the recommendations given in the AAPM TG-21 protocol, which are based on an exposure calibration factor of an ionization chamber in a 60Co beam. The purpose of this work is to compare the determination of absorbed dose-to-water in reference conditions in high-energy photon beams following the recommendations given in the two dosimetry protocols. This is realized by performing calibrations of photon beams with nominal accelerating potential of 6, 18 and 25 MV, generated by an Elekta MLCi and SL25 series linear accelerator. Two widely used Farmer-type ionization chambers having different composition, PTW 30001 (PMMA wall) and NE 2571 (graphite wall), were used for this study. Ratios of AAPM TG-51 to AAPM TG-21 doses to water are found to be 1.008, 1.007 and 1.009 at 6, 18 and 25 MV, respectively when the PTW chamber is used. The corresponding results for the NE chamber are 1.009, 1.010 and 1.013. The uncertainties for the ratios of the absorbed dose determined by the two protocols are estimated to be about 1.5%. A detailed analysis of the reasons for the discrepancies is made which includes comparing the formalisms, correction factors and quantities in the two protocols, as well as the influence of the implementation of the different standards for chamber calibration. The latter has been found to have a considerable influence on the differences in clinical dosimetry, even larger than the adoption of the new data and recommended procedures, as most intrinsic differences cancel out due to the adoption of the new formalism.


Assuntos
Fótons/uso terapêutico , Radiometria/normas , Radioterapia de Alta Energia/normas , Fenômenos Biofísicos , Biofísica , Protocolos Clínicos , Humanos , Radiometria/instrumentação , Radiometria/métodos , Sociedades Científicas , Estados Unidos , Água