Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Yonago Acta Med ; 67(3): 233-241, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39193136

RESUMO

Background: The 3Rs (Reduction, Refinement, Replacement) principle is driving the need for alternative methods in animal testing. Despite advancements in in vitro testing, complex systemic toxicity tests still necessitate in vivo approaches. The aim of this study was to develop a developmental toxicity test protocol using the Iberian ribbed newt (Pleurodeles waltl) as a model organism, integrating AI image analysis for embryo selection to improve test accuracy and reproducibility. Methods: We established a developmental toxicity test protocol based on the zebrafish test. Gonadotropin was administered to induce ovulation, and in vitro fertilization was performed. Embryos were imaged at 5-6 and 6-7 h post-fertilization. AI image analysis was utilized to assess embryo viability. The test chemical was administered 24-48 h post-fertilization, and morphological changes were observed daily until day 8. Additionally, a time-lapse photography system was constructed to monitor embryonic development. Results: Out of 24 cultured embryos, 75% developed normally to the late tail bud stage or initial hatching stage, whereas 25% experienced developmental arrest or death. AI image analysis achieved high accuracy in classifying embryos, with overall accuracies of 92.0% and 92.9% for two learning models. The AI system demonstrated higher precision in the selection of viable embryos compared to visual inspection. Conclusion: The Iberian ribbed newt presents a viable alternative model for developmental toxicity testing, adhering to the 3Rs principles. The integration of AI image analysis substantially enhances the accuracy and reproducibility of embryo selection, providing a reliable method for evaluating developmental toxicity in pharmaceuticals.

2.
Yonago Acta Med ; 66(2): 281-286, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37234223

RESUMO

Background: A drain is often placed in the abdominal cavity for postoperative monitoring and early detection of complications such as rebleeding and pancreatic or bile leaks. Since determining the color of the drainage fluid is subjective, an objective method of judging color is needed. Methods: The hemoglobin concentration of the drainage fluid after gastrointestinal surgery was measured using the Hemato Check Module, a newly developed instrument capable of absorbance analysis with an optical sensor. The correlation between the results and those measured by an existing blood count measuring device (XN3000) was investigated. Results: A total of 215 specimens were analyzed in 43 patients. For the correlation analysis, there was a strong positive correlation with a correlation coefficient of 0.884 (P < 0.001). The Hemato Check Module showed a clear proportional error compared to the XN3000. Conclusion: The Hemato Check Module was a convenient and accurate instrument for measuring hemoglobin concentration in waste fluid to determine the presence of blood.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA