Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Tissue Eng Part A ; 25(9-10): 786-798, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30968738

RESUMO

IMPACT STATEMENT: With the ultimate goal in tissue engineering of approaching in vivo functionality as closely as possible, organ-on-a-chip (OoC) systems provide unprecedented game-changing opportunities by enabling creation of perfused three-dimensional tissues. Most of the recently developed OoC systems, however, require complex handling steps. Hence, a large gap still exists between technology development and collection of valuable biological data in a standardized medium- or high-throughput manner. The system presented here bridges this gap by providing a user-friendly framework for the parallelized creation of multiple physiologically relevant tissues, which could be applicable in every laboratory without additional equipment.


Assuntos
Células-Tronco Pluripotentes Induzidas/metabolismo , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas , Miocárdio/metabolismo , Humanos , Células-Tronco Pluripotentes Induzidas/citologia , Miocárdio/citologia
2.
Doc Ophthalmol ; 138(2): 97-116, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30694438

RESUMO

PURPOSE: The aim of this study was to develop a simple and reliable method for the objective assessment of visual acuity by optimizing the stimulus used in commercially available systems and by improving the methods of evaluation using a nonlinear function, the modified Ricker model. METHODS: Subjective visual acuity in the normal subjects was measured with Snellen targets, best-corrected, and in some cases also uncorrected and with plus lenses (+ 1 D, + 2 D, + 3 D). In patients, subjective visual acuity was measured best-corrected using the Freiburg Visual Acuity Test. Sweep VEP recordings to 11 spatial frequencies, with check sizes in logarithmically equidistant steps (0.6, 0.9, 1.4, 2.1, 3.3, 4.9, 7.3, 10.4, 18.2, 24.4, and 36.5 cpd), were obtained from 56 healthy subjects aged between 17 and 69 years (mean 42.5 ± 15.3 SD years) and 20 patients with diseases of the lens (n = 6), retina (n = 8) or optic nerve (n = 6). The results were fit by a multiple linear regression (2nd-order polynomial) or a nonlinear regression (modified Ricker model) and parameters compared (limiting spatial frequency (sflimiting) and the spatial frequency of the vertex (sfvertex) of the parabola for the 2nd-order polynomial fitting, and the maximal spatial frequency (sfmax), and the spatial frequency where the amplitude is 2 dB higher than the level of noise (sfthreshold) for the modified Ricker model. RESULTS: Recording with 11 spatial frequencies allows a more accurate determination of acuities above 1.0 logMAR. Tuning curves fitted to the results show that compared to the normal 2nd-order polynomial analysis, the modified Ricker model is able to describe closely the amplitudes of the sweep VEP in relation to the spatial frequencies of the presented checkerboards. In patients with a visual acuity better than about 0.5 (decimal), the predicted acuities based on the different parameters show a good match of the predicted visual acuities based on the models established in healthy volunteers to the subjective visual acuities. However, for lower visual acuities, both models tend to overestimate the visual acuity (up to ~ 0.4 logMAR), especially in patients suffering from AMD. CONCLUSIONS: Both models, the 2nd-order polynomial and the modified Ricker model performed equally well in the prediction of the visual acuity based on the amplitudes recorded using the sweep VEP. However, the modified Ricker model does not require the exclusion of data points from the fit, as necessary when fitting the 2nd-order polynomial model making it more reliable and robust against outliers, and, in addition, provides a measure for the noise of the recorded results.


Assuntos
Potenciais Evocados Visuais/fisiologia , Doenças do Cristalino/fisiopatologia , Doenças do Nervo Óptico/fisiopatologia , Doenças Retinianas/fisiopatologia , Acuidade Visual/fisiologia , Adolescente , Adulto , Idoso , Eletrorretinografia , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Testes Visuais/métodos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA