Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Nanotechnology ; 35(1)2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37793353

RESUMO

We report on the superconducting properties and intermediate resistive steps (IRS) observed in the current-voltage characteristics (IVC) of tungsten meander (MW) structures fabricated using focused ion beam (FIB) technique. Three number of MWs were studied with individual wire widths of 240 nm, 640 nm and 850 nm with superconducting transition temperatures (TC) of 4.5 K, 4.55 K and 4.60 K respectively. The measured normal state resistance values at 8 K for these wires are of ∼182 kΩ, ∼49 kΩ and ∼32 kΩ, respectively as a function of increasing wire widths; are higher than the quantum of resistance (h/4e2=6.45kΩ,his a Planck constant andeis electronic charge) indicating extreme disorder nature of the fabricated samples. The variation of resistance with respect to temperature (forT

2.
Acta Oncol ; 62(10): 1201-1207, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37712509

RESUMO

BACKGROUND: This study aimed at investigating the feasibility of developing a deep learning-based auto-segmentation model for the heart trained on clinical delineations. MATERIAL AND METHODS: This study included two different datasets. The first dataset contained clinical heart delineations from the DBCG RT Nation study (1,561 patients). The second dataset was smaller (114 patients), but with corrected heart delineations. Before training the model on the clinical delineations an outlier-detection was performed, to remove cases with gross deviations from the delineation guideline. No outlier detection was performed for the dataset with corrected heart delineations. Both models were trained with a 3D full resolution nnUNet. The models were evaluated with the dice similarity coefficient (DSC), 95% Hausdorff distance (HD95) and Mean Surface Distance (MSD). The difference between the models were tested with the Mann-Whitney U-test. The balance of dataset quantity versus quality was investigated, by stepwise reducing the cohort size for the model trained on clinical delineations. RESULTS: During the outlier-detection 137 patients were excluded from the clinical cohort due to non-compliance with delineation guidelines. The model trained on the curated clinical cohort performed with a median DSC of 0.96 (IQR 0.94-0.96), median HD95 of 4.00 mm (IQR 3.00 mm-6.00 mm) and a median MSD of 1.49 mm (IQR 1.12 mm-2.02 mm). The model trained on the dedicated and corrected cohort performed with a median DSC of 0.95 (IQR 0.93-0.96), median HD95 of 5.65 mm (IQR 3.37 mm-8.62 mm) and median MSD of 1.63 mm (IQR 1.35 mm-2.11 mm). The difference between the two models were found non-significant for all metrics (p > 0.05). Reduction of cohort size showed no significant difference for all metrics (p > 0.05). However, with the smallest cohort size, a few outlier structures were found. CONCLUSIONS: This study demonstrated a deep learning-based auto-segmentation model trained on curated clinical delineations which performs on par with a model trained on dedicated delineations, making it easier to develop multi-institutional auto-segmentation models.


Assuntos
Aprendizado Profundo , Humanos , Benchmarking , Coração , Cooperação do Paciente , Processamento de Imagem Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...