Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
UCL Open Environ ; 3: e018, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-37228789

RESUMO

As a basic study of a practical method for predicting the sound insulation performance of windows, this report presents a study of the sound reduction index of windows with single glazing, below a critical frequency. First, the results calculated by an existing theory for a single plate for the sound reduction indices are compared with measured results of actual windows to assess the theory's applicability for evaluating the sound insulation performance of windows. Then, a regression analysis is employed to measure the results of a certain number of actual windows to explore a further development of a more practical prediction. The following findings were obtained: (1) Sound reduction indices of actual fixed windows are predictable using Sewell's transmission theory for a single plate. However, sound reduction indices of openable windows, especially those of sliding windows, are strongly affected by gaps in the window frame. Therefore, predicting sound reduction indices of all windows accurately is difficult if using only one theory. (2) The frequency slope of the window reduction index is much lower than that of the mass law. Regression analyses indicate that the frequency slope of the reduction index of all examined windows is 3.0 dB per octave, on average.

2.
UCL Open Environ ; 3: e021, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-37228792

RESUMO

There are various measures currently in place to prevent the spread of coronavirus (COVID-19); however, in some cases, these can have an adverse effect on the acoustic environment in buildings. For example, transparent acrylic partitions are often used in eating establishments, meeting rooms, offices, etc., to prevent droplet infection. However, acrylic partitions are acoustically reflective; therefore, reflected sounds may cause acoustic problems such as difficulties in conversation or the leakage of conversation. In this study, we performed a prototyping of transparent acrylic partitions to which a microperforated panel (MPP) was applied for sound absorption while maintaining transparency. The proposed partition is a triple-leaf acrylic partition with a single acrylic sheet without holes between two MPP sheets, as including a hole-free panel is important to prevent possible droplet penetration. The sound absorption characteristics were investigated by measuring the sound absorption in a reverberation room. As the original prototype showed sound absorption characteristics with a gentle peak and low values due to the openings on the periphery, it was modified by closing the openings on the top and sides. The sound absorption performance was improved to some extent when the top and sides were closed, although there remains the possibility of further improvement. For this study, only the sound absorption characteristics were examined in the prototype experiments. The effects during actual use will be the subject of future study.

3.
UCL Open Environ ; 2: e012, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-37229290

RESUMO

In this study, we first point out the possible acoustic problems associated with the post-pandemic operation of built environments. In particular, we focus on the problem of acoustic deficiency due to the lack of absorption. This deficiency, which is likely to be encountered in most enclosed spaces in a range of establishments, is due to the reduced number of audience members or users of the space as a result of social distancing. As one of the promising solutions to this problem, we introduce a sound absorption technique using three-dimensional (3D) space sound absorbers developed through our recent research projects. Significantly, the type of sound absorber proposed herein is made of materials that are especially suited to hygiene considerations. The materials are microperforated panels (MPPs) and permeable membranes (PMs), both of which are easily washable and sanitised. Furthermore, we point out that 3D-MPP or PM space absorbers possess the additional value of aesthetic designability.

4.
UCL Open Environ ; 2: e009, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-37229295

RESUMO

The COVID-19 pandemic caused lockdowns in many countries worldwide. Acousticians have made surveys to monitor how cities became quieter under the lockdown, mainly in central areas in cities. However, there have been few studies on the changes in the acoustic environment due to the pandemic in the usually quieter residential areas. It may be expected to be different from the effect in 'originally noisy' areas. Also, the effect could be different in Japan, because the 'state of emergency' declaration there was different to lockdowns elsewhere. Considering these circumstances, this article reports the results of noise monitoring and makes some observations on the acoustic environment in residential areas far from city centres, to provide an example of how the acoustic environment was affected by the state of emergency declaration due to the COVID-19 pandemic in Japan. The results showed that the reduction of noise levels was somewhat less than that reported in large cities. Also, comparing the results after the cancellation of the state of emergency, the noise level increased again. However, observations of noise sources imply that a possible change in human behaviour may have also affected the acoustic environment.

5.
J Acoust Soc Am ; 140(1): 453, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27475169

RESUMO

Although sound radiation from sound-induced vibration and from force-excited vibration of solid structures are similar phenomena in terms of radiating from vibrating structures, the general relationship between them has not been explicitly studied to date. In particular, airborne sound transmission through walls and sound radiation from structurally vibrating surfaces in buildings are treated as different issues in architectural acoustics. In this paper, a fundamental relationship is elucidated through the use of a simple model. The transmission coefficient for random-incidence sound and the radiated sound power under point force excitation of an infinite elastic plate are both analyzed. Exact and approximate solutions are derived for the two problems, and the relationship between them is theoretically discussed. A conversion function that relates the transmission coefficient and radiated sound power is obtained in a simple closed form through the approximate solutions. The exact solutions are also related by the same conversion function. It is composed of the specific impedance and the wavenumber, and is independent of any elastic plate parameters. The sound radiation due to random-incidence sound and point force excitation are similar phenomena, and the only difference is the gradient of those characteristics with respect to the frequency.

6.
J Acoust Soc Am ; 138(6): 3531-8, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26723310

RESUMO

Microperforated panels (MPPs) are next-generation absorption materials because they can provide wideband sound absorption without fibrous materials and can be composed of diverse materials to meet global environmental demands. The fundamental absorbing mechanism is Helmholtz-resonance absorption due to perforations and an air cavity. MPPs are typically backed by rigid flat walls, but to reduce the restrictions on the MPP absorber properties, one of the authors has proposed MPP space sound absorbers without backing structures, including three-dimensional cylindrical microperforated panel space absorbers (CMSAs). Advantages of MPPs without backing structures are design flexibility and ease of use. Besides, the absorption characteristics of a CMSA with a core, which has a rigid cylindrical core inside the CMSA, have been experimentally tested, but a method to predict the absorption characteristics is necessary to design CMSAs with cores. Herein the two-dimensional combined Helmholtz integral formulation method is employed, and its prediction accuracy is evaluated by comparing the measured and predicted absorption characteristics of a CMSA with a core. Furthermore, a parametric study with regard to the core size is carried out to investigate the transition of the absorbing mechanism.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...