Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Int Heart J ; 59(2): 403-406, 2018 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-29563379

RESUMO

Spontaneous coronary artery dissection (SCAD) is a rare cause of acute coronary syndrome and little is known about characteristics, treatment, and follow-up of patients with SCAD. Computed tomography angiography (CTA) plays an important role in the diagnosis and management of SCAD. Herein, we describe a case of a patient with SCAD who underwent successful conservative management, and in whom CTA was able to detect rapid healing of the dissection, 4.5 hours post-dissection.


Assuntos
Angiografia por Tomografia Computadorizada , Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/terapia , Infarto do Miocárdio com Supradesnível do Segmento ST/etiologia , Doenças Vasculares/congênito , Adulto , Tratamento Conservador , Anomalias dos Vasos Coronários/complicações , Humanos , Masculino , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Doenças Vasculares/complicações , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/terapia
2.
Cardiovasc Interv Ther ; 33(1): 62-69, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27830459

RESUMO

Some studies have suggested that radial access (RA) for percutaneous coronary intervention (PCI) reduces vascular complications and bleeding compared to femoral access (FA). The purpose of this study was to investigate the routine use of hemostatic devices and bleeding complications among RA, brachial access (BA), and FA. Between January 2015 and December 2015, 298 patients treated for PCI with RA were compared with 158 patients using BA and 206 patients using FA. The radial sheath was routinely removed with ADAPTY, the brachial sheath with BLEED SAFE, and the femoral sheath with Perclose ProGlide. In-hospital bleeding complications were investigated. Cardiogenic shock was most frequent in patients in the femoral group (RA 1.3%, BA 2.5%, FA 9.2%, p < 0.0001). The rate of major bleeding was highest in the femoral group (RA 1.0%, BA 2.5%, FA 5.3%, p = 0.01). Blood transfusion rates were highest in the femoral group (RA 0.7%, BA 1.3%, FA 4.4%, p = 0.01). Retroperitoneal bleeding was observed in 1.9% of patients in the femoral group. Patients in the brachial group had large hematomas (RA 0.7%, BA 4.4%, FA 1.5%, p = 0.01). Pseudoaneurysm formation needing intervention occurred most frequently in the brachial group (RA 0%, BA 1.3%, FA 0%, p = 0.04). In conclusion, compared to the brachial and femoral approaches, the radial approach appears to be the safest technique to avoid local vascular bleeding complications. The brachial approach has the highest risk of large hematoma and pseudoaneurysm formation among the three groups.


Assuntos
Artéria Braquial/cirurgia , Doença da Artéria Coronariana/terapia , Artéria Femoral/cirurgia , Intervenção Coronária Percutânea/métodos , Artéria Radial/cirurgia , Dispositivos de Oclusão Vascular/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Falso Aneurisma/etiologia , Artéria Braquial/lesões , Feminino , Artéria Femoral/lesões , Hemorragia/etiologia , Hemostasia Cirúrgica/efeitos adversos , Hemostasia Cirúrgica/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Artéria Radial/lesões
4.
J Invasive Cardiol ; 29(6): E69-E70, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28570240

RESUMO

Kugel described the arteria anastomotica auricularis magna. We describe a first case of chronic total occlusion of the right coronary artery that was successfully recanalized using the reverse controlled antegrade and retrograde subintimal tracking technique through the ipsilateral Kugel's artery collateral.


Assuntos
Angioplastia Coronária com Balão/métodos , Circulação Colateral , Circulação Coronária , Oclusão Coronária/cirurgia , Vasos Coronários/cirurgia , Doença Crônica , Angiografia Coronária/métodos , Oclusão Coronária/diagnóstico , Oclusão Coronária/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade
6.
J Am Heart Assoc ; 3(2): e000703, 2014 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-24650925

RESUMO

BACKGROUND: Stent fracture (SF) after drug-eluting stent implantation has become an important concern. The aim of this study was to assess the incidence, predictors, and clinical impact of SF after biolimus-eluting stent. METHODS AND RESULTS: A total of 1026 patients with 1407 lesions undergoing the Nobori biolimus-eluting stent implantation and follow-up angiography within 9 months after index procedure were analyzed. SF was defined as complete or partial separation of the stent, as assessed by using plain fluoroscopy, intravascular ultrasound, or optical coherence tomography during the follow-up. We assessed the rate of SF and the cumulative incidence of clinically driven target lesion revascularization and definite stent thrombosis within 9 months. SF was observed in 58 (4.1%) of 1407 lesions and 57 (5.5%) of 1026 patients. Lesions with hinge motion (OR 8.90, 95% CI 3.84 to 20.6, P<0.001), tortuosity (OR 4.16, 95% CI 1.75 to 9.88, P=0.001), and overlapping stents (OR 2.41, 95% CI 0.95 to 6.10, P=0.06) were predictors of SF. Cumulative incidence of clinically driven target lesion revascularization within 9 months was numerically higher in the SF group than that in the non-SF group (12.0% versus 1.0%). Cumulative incidence of definite stent thrombosis within 9 months tended to be higher in the SF group than that in the non-SF group (1.7% versus 0.5%). CONCLUSIONS: SF after biolimus-eluting stent occurs in 4.1% of lesions and appears to be associated with clinically driven target lesion revascularization.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Falha de Prótese , Sirolimo/análogos & derivados , Idoso , Idoso de 80 Anos ou mais , Distribuição de Qui-Quadrado , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/epidemiologia , Reestenose Coronária/epidemiologia , Trombose Coronária/epidemiologia , Feminino , Humanos , Incidência , Japão/epidemiologia , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Fatores de Risco , Sirolimo/administração & dosagem , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento , Ultrassonografia de Intervenção
7.
Cardiovasc Diabetol ; 12: 74, 2013 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-23651930

RESUMO

BACKGROUND: Post-challenge hyperglycemia (PH) is well-established as one of risk factors for coronary artery disease. However, it remains unclear whether PH affects clinical outcomes in patients with stable angina undergoing percutaneous coronary intervention (PCI). METHODS: A total of 828 patients with stable angina undergoing PCI were retrospectively analyzed. Of these, 452 patients with previously diagnosed diabetes mellitus (DM) or fasting plasma glucose (PG) ≥126 mg/dl and HbA1c ≥6.5% were defined as known DM. The remaining 376 patients were divided into the two groups according to 2-h PG: PH (2-h PG ≥140 mg/dl, n=236) and normal glucose tolerance (NGT, 2-h PG <140 mg/dl, n=140). We assessed the rate of major adverse cardiovascular events (MACE), defined as a composite of cardiovascular death, myocardial infarction, stroke, and clinically-driven revascularization. RESULTS: During the median follow-up of 4.3 years, the MACE rate was significantly higher in the DM and PH groups than the NGT group (39.3% vs. 20.7%, P <0.001; 31.4% vs. 20.7%, P=0.044, respectively). Compared with the NGT group, the cumulative incidence of revascularization was significantly higher in the DM group (35.1% vs. 18.5%, P <0.001) and tended to be higher in the PH group (27.1% vs. 18.5%, P=0.067). In the multivariate analysis, known DM (Hazard ratio [HR]: 2.16, 95% confidence interval (CI): 1.49-3.27, P < 0.001), PH (HR: 1.62, 95% CI: 1.07-2.53, P = 0.023), LDL-C >100 mg/dl (HR: 1.62, 95% CI: 1.26 to 2.10, P < 0.001), and previous stroke (HR: 1.47, 95% CI: 1.03-2.04, P = 0.034) were predictors of MACE. CONCLUSION: PH is associated with future cardiovascular events in patients with stable angina undergoing PCI.


Assuntos
Angina Estável/terapia , Diabetes Mellitus Tipo 2/complicações , Intolerância à Glucose/complicações , Intervenção Coronária Percutânea , Idoso , Angina Estável/complicações , Angina Estável/mortalidade , Feminino , Seguimentos , Teste de Tolerância a Glucose , Humanos , Hiperglicemia/complicações , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Resultado do Tratamento
9.
EuroIntervention ; 8(8): 962-9, 2012 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-23014985

RESUMO

AIMS: The aim of this study was to evaluate very long-term clinical outcomes and potential predictors after percutaneous coronary intervention (PCI) with bare metal stents (BMS) for unprotected left main coronary artery disease (ULMCAD). METHODS AND RESULTS: From March 1991 to August 2001, 151 patients who underwent PCI with BMS for ULMCAD were investigated retrospectively. The patient-oriented major adverse cardiac events (MACE) were defined as the occurrence of all-cause death, any MI, and any coronary revascularisation. The median follow-up duration was 10.5 years. The mean age was 69.9±11.5 years, and 106 patients (70.2%) were male. At 10 years, the incidences of cardiac death (CD), target lesion revascularisation (TLR) and patient-oriented MACE were 11.1%, 25.2% and 81.9%, respectively. In multivariate analysis, the pre-reference diameter of the left main trunk (LMT) was significantly associated with TLR (adjusted hazard ratio [HR] [95% confidence interval (CI)], 0.28 [0.14-0.54], p<0.001) and the SYNTAX score remained an independent predictor of patient-oriented MACE (adjusted HR [95% CI], 1.03 [1.007-1.05], p=0.009). CONCLUSIONS: The pre-reference diameter of LMT was significantly associated with TLR, and the SYNTAX score significantly predicted the risk of patient-oriented MACE at 10 years. BMS implantation for larger size of ULMCAD with a lower SYNTAX score was feasible for up to 10 years.


Assuntos
Doença da Artéria Coronariana/terapia , Infarto do Miocárdio/prevenção & controle , Revascularização Miocárdica/estatística & dados numéricos , Intervenção Coronária Percutânea/estatística & dados numéricos , Stents/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/mortalidade , Estenose Coronária/mortalidade , Estenose Coronária/terapia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/mortalidade , Prognóstico , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
10.
Circ Cardiovasc Interv ; 5(5): 663-71, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23011266

RESUMO

BACKGROUND: Stent fracture (SF) after drug-eluting stent implantation has recently become an important concern because of its potential association with in-stent restenosis and stent thrombosis. However, the incidence and clinical impact of SF after everolimus-eluting stent implantation remain unclear. METHODS AND RESULTS: A total of 1035 patients with 1339 lesions undergoing everolimus-eluting stent implantation and follow-up angiography 6 to 9 months after index procedure were analyzed. SF was defined as complete or partial separation of the stent, as assessed by plain fluoroscopy or intravascular ultrasound during follow-up. We assessed the rates of SF and major adverse cardiac events, defined as cardiac death, myocardial infarction, stent thrombosis, and clinically driven target lesion revascularization within 9 months. SF was observed in 39 of 1339 lesions (2.9%) and in 39 of 1035 patients (3.8%). Ostial stent location and lesions with hinge motion, tortuosity, or calcification were independent predictors of SF. The rate of myocardial infarction and target lesion revascularization were significantly higher in the SF group than in the non-SF group (5.1% versus 0.4%; P=0.018 and 25.6% versus 2.0%; P<0.001, respectively). Stent thrombosis was more frequently observed in the SF group than in the non-SF group (5.1% versus 0.4%; P=0.018). Major adverse cardiac events within 9 months were significantly higher in the SF group than in the non-SF group (25.6% versus 2.3%; P<0.001). CONCLUSIONS: SF after everolimus-eluting stent implantation occurs in 2.9% of lesions and is associated with higher rate of major adverse cardiac events, driven by higher target lesion revascularization and stent thrombosis.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Falha de Prótese , Sirolimo/análogos & derivados , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Distribuição de Qui-Quadrado , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/diagnóstico , Trombose Coronária/etiologia , Trombose Coronária/mortalidade , Everolimo , Feminino , Humanos , Incidência , Japão , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Razão de Chances , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Sirolimo/administração & dosagem , Fatores de Tempo , Ultrassonografia de Intervenção , Calcificação Vascular/diagnóstico , Calcificação Vascular/mortalidade , Calcificação Vascular/terapia
11.
Catheter Cardiovasc Interv ; 79(1): 50-6, 2012 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-22215567

RESUMO

OBJECTIVES: We aimed to see whether primary percutaneous coronary intervention (PCI) benefits for ST-segment elevation myocardial infarction (STEMI) in the aged could be validated. BACKGROUND: Primary PCI benefits in elderly patients with STEMI remain uncertain. METHODS: We reviewed 947 consecutive patients treated with primary PCI for STEMI: 331 were aged ≥75 years (older) and 616 <75 years (younger). RESULTS: The older group had higher percentage of renal insufficiency (7.9% vs. 3.1%, P = 0.0010), prior stroke (9.4% vs. 3.9%, P = 0.0006), 30-day mortality rate (7.6% vs. 3.9%, P = 0.015), and cardiac mortality rate (6.6% vs. 3.7%, P = 0.045). Successful reperfusion rates were similarly high in both groups (90.0% and 92.7%, P = 0.16), despite the higher proportion of patients with door-to-balloon time >90 min (15% vs. 8.4%, P = 0.0016) in older patients. Successful compared with unsuccessful PCI significantly decreased 30-day mortality rates in the older group (6.0% vs. 21%, P = 0.0018) and in the younger group (2.8% vs. 18%, P < 0.0001). When reperfusion was successful, cardiac mortality rate in older patients was not significantly greater than in younger patients (5.4% vs. 2.8%, P = 0.057). By multivariate analysis, unsuccessful reperfusion independently predicted 30-day mortality (odds ratio, 4.04; 95% confidence interval, 1.79-9.12; P = 0.0008), whereas age ≥75 years (odds ratio, 1.00; 95% confidence interval, 0.41-2.41; P = 0.99) and door-to-balloon time >90 min (odds ratio, 1.78; 95% confidence interval, 0.76-4.20; P = 0.19) did not. CONCLUSIONS: Pre-existing comorbidities characterize older patients developing STEMI. Aggressive PCI in older patients improves prognosis, and short door-to-balloon time is an important parameter conditioning the prognosis.


Assuntos
Angioplastia Coronária com Balão , Infarto do Miocárdio/terapia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Causas de Morte , Distribuição de Qui-Quadrado , Comorbidade , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/mortalidade , Razão de Chances , Seleção de Pacientes , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
12.
Circ Cardiovasc Interv ; 5(1): 47-54, 2012 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-22253359

RESUMO

BACKGROUND: Very late stent thrombosis (VLST) was reported to occur even in patients with bare metal stent (BMS) implantation, although the annual incidence of VLST after BMS was much lower than that after drug-eluting stent implantation. Pathophysiologic mechanisms of VLST after BMS implantation remain largely unknown. METHODS AND RESULTS: From September 2002 to February 2010, we identified 102 patients with definite stent thrombosis (ST) of BMS and 42 control patients with acute coronary syndrome (ACS) unrelated to ST who underwent thrombus aspiration with histopathologic evaluation. There were 40 patients with early ST (EST, within 30 days), 20 patients with late ST (LST, between 31-365 days), and 42 patients with VLST (>1 year). Evidence for fragments of atherosclerotic plaques, such as foamy macrophages, cholesterol crystals, and thin fibrous cap, was more commonly seen in patients with EST (23%) and VLST (31%), whereas these findings were rarely observed in patients with LST (10%). Atherosclerotic fragments were predominantly seen in patients who had EST within 7 days or VLST beyond 3 years. The aspirated thrombi harvested from patients with ST and those with ACS were histologically indistinguishable from each other. Eosinophils were very rarely observed. Plasma level of total cholesterol and triglyceride were significantly higher in VLST cases with atherosclerotic fragments as compared with those without. CONCLUSIONS: Fragments of atherosclerotic plaque were highly prevalent in patients with VLST beyond 3 years. Disruption of in-stent neoatherosclerosis could play an important role in the pathogenesis of VLST of BMS occurring beyond 3 years after implantation.


Assuntos
Implante de Prótese Vascular/efeitos adversos , Placa Aterosclerótica/patologia , Complicações Pós-Operatórias/etiologia , Stents/efeitos adversos , Trombose/etiologia , Idoso , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/cirurgia , Feminino , Seguimentos , Humanos , Incidência , Japão , Masculino , Metais , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/patologia , Prevalência , Trombose/epidemiologia , Trombose/patologia , Fatores de Tempo
13.
Circ J ; 76(2): 423-9, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22156311

RESUMO

BACKGROUND: The relationship between major adverse cardiac events (MACE) and serum polyunsaturated fatty acid (PUFA) parameters has not been well documented in patients who have undergone percutaneous coronary intervention (PCI). The aim of the present study was to investigate this relationship. METHODS AND RESULTS: A total of 284 consecutive patients who underwent elective PCI were enrolled and stratified according to median serum levels of n-6 PUFAs (arachidonic acid [AA]), n-3 PUFAs (eicosapentaenoic acid [EPA] and docosahexaenoic acid [DHA]), and serum EPA/AA and DHA/AA ratios. The relationship between these PUFA parameters and the incidence of MACE including cardiac death, acute coronary syndrome, PCI for de novo lesions, and coronary artery bypass grafting, was analyzed. Multivariate analysis showed that among the PUFA parameters, only a high serum EPA/AA ratio was significantly associated with a low incidence of MACE in all the models tested (model A, without adjusted variables: hazard ratio [HR], 0.52; 95% confidence interval [CI]: 0.27-0.99, P = 0.048; model B, adjusted for age and diabetes: HR, 0.51; 95%CI: 0.26-0.98, P = 0.043; model C, adjusted for age, sex, diabetes, hypertension, smoking, and low-density lipoprotein cholesterol: HR, 0.49; 95%CI: 0.25-0.94, P = 0.033). CONCLUSIONS: The incidence of MACE in patients who have undergone PCI is significantly associated with serum EPA/AA ratio.


Assuntos
Angina Pectoris/epidemiologia , Angina Pectoris/terapia , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/estatística & dados numéricos , Ácidos Graxos Ômega-3/sangue , Ácidos Graxos Ômega-6/sangue , Idoso , Idoso de 80 Anos ou mais , Ácido Araquidônico/sangue , Biomarcadores/sangue , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Prognóstico , Fatores de Risco
14.
J Am Heart Assoc ; 1(5): e004085, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23316303

RESUMO

BACKGROUND: Target lesion revascularization (TLR) continues to occur beyond 4 years after bare metal stent (BMS) implantation. However, long-term outcomes after balloon angioplasty (BA) compared with BMS are currently unknown. METHODS AND RESULTS: From 1989 to 1990, 659 patients (748 lesions) underwent successful BA with final balloon ≥3.0 mm excluding patients with acute myocardial infarction and were compared with 405 patients (424 lesions) with BMS implantation from June 1990 to 1993. Cumulative incidences of death and target lesion thrombosis (>1 year) were similar between the BA group and the BMS group (44.4% versus 45.4%, P=0.60; and 1.5% versus 0.7%, P=0.99; respectively). Cumulative incidence of TLR during overall follow-up was significantly higher after BA than after BMS implantation (44.6% versus 36.0%, P<0.001), whereas cumulative incidence of late TLR (>4 years) tended to be lower in the BA group than in the BMS group (16.3% versus 21.4%, P=0.16). Cumulative incidence of late TLR after BA was significantly lower in patients with small percent diameter stenosis (%DS) at early follow-up angiography compared with large %DS (14.5% versus 28.0%, P=0.02). In lesions with serial angiography, late lumen loss from early (6 to 14 months) to long-term (4 to 10 years) follow-up angiography was significantly smaller in the BA group (n=42) than in the BMS group (n=55) (-0.08±0.45 mm versus 0.11±0.46 mm, P=0.047). CONCLUSIONS: Compared with BMS implantation, BA was associated with a trend for less late TLR beyond 4 years and with significantly smaller late lumen loss from early to long-term follow-up angiography.


Assuntos
Angioplastia Coronária com Balão/métodos , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/cirurgia , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Causas de Morte , Angiografia Coronária , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prognóstico , Análise de Sobrevida , Resultado do Tratamento
16.
Circ Cardiovasc Interv ; 3(5): 468-75, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20823392

RESUMO

BACKGROUND: We previously reported that the long-term luminal response after coronary bare metal stenting is triphasic, with an early restenosis phase spanning the 6 months after the index procedure, an intermediate-term regression phase from 6 months to 3 years, and a late renarrowing phase beyond 4 years. However, the clinical significance of late luminal renarrowing remains unknown. METHODS AND RESULTS: Angiographic and clinical follow-up of the same cohort of 405 patients with successful Palmaz-Schatz stent placement was extended beyond 15 years. Clinical follow-up was completed in 98% of patients at 5 years and in 81% at 15 years. The incidence of death and cardiac death at 15 years was 45.4% and 20.6%, respectively. Paired long-term (4 to 10 years) and very long-term (>10 years) angiographic studies without intercurrent target lesion revascularization were performed in 55 lesions, and minimal luminal diameter further decreased from 1.88±0.50 mm to 1.60±0.73 mm (P=0.002). Late target lesion revascularization after initial stabilization of the stented segments occurred rarely within 4 years. Beyond 4 years, however, the incidence of late target lesion revascularization increased steadily from 3.3% at 4 years to 24.7% at 15 years. The incidence of definite very late stent thrombosis was low (1.5% at 15 years). CONCLUSIONS: Luminal renarrowing of the stented segment beyond 4 years was a progressive process extending beyond 10 years. The angiographic observation of late in-stent restenosis was clinically relevant because a corresponding progressive increase in the incidence of late target lesion revascularization was observed beyond 4 years and up to 15 to 20 years after bare metal stent implantation.


Assuntos
Implante de Prótese Vascular/efeitos adversos , Doença da Artéria Coronariana/epidemiologia , Reestenose Coronária/etiologia , Stents/efeitos adversos , Trombose/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Implante de Prótese Vascular/mortalidade , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Stents/estatística & dados numéricos , Análise de Sobrevida , Fatores de Tempo
17.
JACC Cardiovasc Interv ; 3(2): 180-8, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20170875

RESUMO

OBJECTIVES: Our aim was to study the relationships between total stent length (TSL) and long-term clinical outcomes after sirolimus-eluting stent (SES) implantation. BACKGROUND: SES compared with bare-metal stent use for long lesion treatment is associated with reduced restenosis rates. METHODS: Three-year follow-up data were available for 10,773 patients (14,651 lesions) that had been treated with only SES (Cypher, Cordis Corp., Warren, New Jersey) in the j-Cypher registry. Patients and lesions were divided into quartile groups: TSL per patient (Q1: 8 to 23 mm, Q2: 24 to 36 mm, Q3: 37 to 54 mm, Q4: 55 to 293 mm), and TSL per lesion (QA: 8 to 18 mm, QB: 19 to 23 mm, QC: 24 to 33 mm, QD: 34 to 150 mm). RESULTS: In per-lesion data, longer TSL increased target lesion revascularization (TLR) rates but did not increase stent thrombosis rates (p = 0.2324). In per-patient data, the incidences of TLR remarkably increased with increasing TSL. Incidence of composite of death and myocardial infarction also increased with increasing TSL; however, after adjustment for baseline differences, there was no statistical significance. Definite stent thrombosis rate in group Q4 was significantly higher than in other groups, both unadjusted (hazard ratio: 1.770, p = 0.0081) and adjusted (hazard ratio: 1.727, p = 0.0122) for baseline differences. CONCLUSIONS: TSL per lesion and patient had significantly impacts on TLR rates. Longer TSL per patient was associated with increased incidence of stent thrombosis through 3 years.


Assuntos
Reestenose Coronária/prevenção & controle , Stents Farmacológicos , Imunossupressores/uso terapêutico , Sirolimo/uso terapêutico , Resultado do Tratamento , Idoso , Intervalos de Confiança , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/prevenção & controle , Reestenose Coronária/mortalidade , Feminino , Humanos , Japão , Modelos Logísticos , Masculino , Modelos de Riscos Proporcionais , Sistema de Registros , Risco , Fatores de Risco , Fatores de Tempo
18.
Eur J Cardiovasc Prev Rehabil ; 17(2): 230-4, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20051870

RESUMO

BACKGROUND: Early exercise after coronary stenting is considered to have a risk of stent thrombosis (ST). We investigate the safety of submaximal exercise training based on the Borg scale from the next day after coronary stenting. METHODS: We enrolled 2351 patients who underwent successful coronary stenting. They were divided into early exercise training (EET) group (n=865) and control group (n=1486). Submaximal exercise training based on the Borg scale was performed on the next day after coronary stenting and same degree exercise was continued more than two times a week after discharge. Primary endpoint was the incidence of ST. Secondary endpoint was major adverse cardiovascular event (death, myocardial infarction, and stroke), incidence of postoperative complications, and rate of exercise continuation. RESULTS: Exercise training was performed in 800 (92.5%) patients. No serious complication developed during and after exercise. Clinical follow-up data were obtained in 99% patients. At 30 days, there was no significant difference in the incidence of ST (0.58 vs. 0.47%, P=0.73), major adverse cardiovascular event (1.4 vs. 1.3%, P=0.72), and complication rate (6.9 vs. 7.3%, P=0.72). No exercise-related ST was found in either group. The rate of exercise continuation was significantly higher in the EET group (49.3 vs. 28.3%, P<0.001). CONCLUSION: EET up to submaximal level based on the Borg scale from the day after elective coronary stenting does not increase the incidence of ST or postoperative complications.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/terapia , Terapia por Exercício/efeitos adversos , Stents , Trombose/etiologia , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Distribuição de Qui-Quadrado , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Modelos de Riscos Proporcionais , Estudos Prospectivos , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Trombose/mortalidade , Trombose/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
19.
Circ J ; 71(9): 1442-5, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17721025

RESUMO

BACKGROUND: Optimal target vein selection for the pacing lead results in a better outcome, but left ventricular (LV) variability limits this selection. The aim of the present study was to investigate the efficacy of coronary venoplasty for insertion of a LV lead. METHODS AND RESULTS: Transvenous LV lead placement was attempted in 208 consecutive patients from November 2002 to January 2007, with success in 206 patients (99%). Retrospective analysis of the cardiac resynchronization therapy system implantation showed that 4 of the 206 patients (1.9%) required coronary venoplasty for insertion of the pacing lead implant. Using coronary balloon angioplasty catheters of 2.5 mm (2 patients), 3.0 mm (1 patient) and 4.0 mm (1 patient), each target vein was dilated. Of 4 patients, stenoses in 3 were dilated by balloon angioplasty only. However, focal stenosis of 1 patient was not able to be dilated due to severe stenosis. Therefore, part of the lesion was sharpened by rotational atherectomy and the stenosis was successfully dilated. The LV pacing lead could then be inserted and no complications occurred. CONCLUSION: Venoplasty for stenosis was effective in allowing deployment of a LV lead into a target vein in some patients. The safety and complications of the procedure remain unclear.


Assuntos
Angioplastia com Balão , Estimulação Cardíaca Artificial , Estenose Coronária/terapia , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Estenose Coronária/patologia , Vasos Coronários/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
20.
Int Heart J ; 48(3): 387-92, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17592203

RESUMO

Coronary embolism is one of the less common causes of acute myocardial infarction (AMI). We describe a 72-year-old man with atrial fibrillation having an AMI, in whom a massive intracoronary thrombus of the right coronary artery was successfully removed by aspiration via a thrombectomy catheter, achieving successful reperfusion with a complete resolution of ST-segment elevation. The appearance of the aspirated material suggested coronary embolism was the cause of the AMI. It is concluded aspiration thrombectomy is a feasible and safe approach for treating coronary embolism.


Assuntos
Vasos Coronários , Infarto do Miocárdio/cirurgia , Trombectomia/métodos , Tromboembolia/complicações , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/instrumentação , Angiografia Coronária , Eletrocardiografia , Seguimentos , Humanos , Masculino , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/etiologia , Tromboembolia/diagnóstico por imagem , Tromboembolia/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...