Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Radiat Res ; 65(2): 159-167, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38151953

RESUMO

Previous studies have primarily focused on quality of imaging in radiotherapy planning computed tomography (RTCT), with few investigations on imaging doses. To our knowledge, this is the first study aimed to investigate the imaging dose in RTCT to determine baseline data for establishing national diagnostic reference levels (DRLs) in Japanese institutions. A survey questionnaire was sent to domestic RT institutions between 10 October and 16 December 2021. The questionnaire items were volume computed tomography dose index (CTDIvol), dose-length product (DLP), and acquisition parameters, including use of auto exposure image control (AEC) or image-improving reconstruction option (IIRO) for brain stereotactic irradiation (brain STI), head and neck (HN) intensity-modulated radiotherapy (IMRT), lung stereotactic body radiotherapy (lung SBRT), breast-conserving radiotherapy (breast RT), and prostate IMRT protocols. Details on the use of motion-management techniques for lung SBRT were collected. Consequently, we collected 328 responses. The 75th percentiles of CTDIvol were 92, 33, 86, 23, and 32 mGy and those of DLP were 2805, 1301, 2416, 930, and 1158 mGy·cm for brain STI, HN IMRT, lung SBRT, breast RT, and prostate IMRT, respectively. CTDIvol and DLP values in institutions that used AEC or IIRO were lower than those without use for almost all sites. The 75th percentiles of DLP in each treatment technique for lung SBRT were 2541, 2034, 2336, and 2730 mGy·cm for free breathing, breath holding, gating technique, and real-time tumor tracking technique, respectively. Our data will help in establishing DRLs for RTCT protocols, thus reducing imaging doses in Japan.


Assuntos
Encéfalo , Radiocirurgia , Tomografia Computadorizada por Raios X , Humanos , Masculino , Japão , Doses de Radiação , Valores de Referência , Inquéritos e Questionários , Tomografia Computadorizada por Raios X/métodos , Encéfalo/efeitos da radiação
2.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 79(6): 544-554, 2023 Jun 20.
Artigo em Japonês | MEDLINE | ID: mdl-37062712

RESUMO

In this study, we investigated the necessary phantom length for dose evaluation of kV-CBCT mounted on the linear accelerator using a Farmer-type ionization chamber and cylindrical PMMA phantom, which many radiotherapy facilities own. Furthermore, a phantom length correction factor was proposed to compensate for the lack of scattered radiation contributed from the craniocaudal direction due to the inadequate phantom length. The air-absorbed dose at the center of a cylindrical PMMA phantom measured by a Farmer-type ionization chamber indicated that the contribution of scattered radiation saturates when the phantom length is 300 mm or longer. The phantom length correction factor was calculated from an approximate curve showing the relationship of the charge ratio measured using phantoms of 300 mm and 150 mm in length to the X-ray beam width. The air-absorbed dose measured with the 150-mm length phantom, corrected by the phantom length correction factor, showed a 1.61% dose difference from the air-absorbed dose measured with the 300-mm length phantom. In this study, the air-absorbed dose at the center of the phantom could be estimated over a wide X-ray beam width only using a 150-mm length cylindrical PMMA phantom. The method proposed in this study could be used in any radiation therapy facility.


Assuntos
Fazendeiros , Polimetil Metacrilato , Humanos , Doses de Radiação , Tomografia Computadorizada de Feixe Cônico/métodos , Imagens de Fantasmas
3.
Radiat Prot Dosimetry ; 199(3): ncac262 246 253-253, 2023 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-36566494

RESUMO

This study presents a new idea for estimating the number of measurements required for determining the uncertainty in obtaining the desired water absorbed dose using the variation obtained from multicenter absorbed dose measurement data. The number of dose measurements depends on the performance of each linear accelerator (LINAC) tested and the dosimetry equipment and procedure used. However, optimising the number of data collected for the absorbed dose to water has been inadequately reported. Using the absorbed dose measurement data collected 10 times as a reference value, we will compare the changes in the variation of the measurement results caused by the difference in the number of repeated measurements of the absorbed dose. The number of measurements is determined statistically such that this variation would be smaller than the change in absorbed dose. Thus, we can determine the optimum number of measurements suitable for the variability of each LINAC.


Assuntos
Fótons , Água , Radiometria , Imagens de Fantasmas , Incerteza , Calibragem
4.
J Radiat Res ; 63(5): 749-757, 2022 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-35818301

RESUMO

We evaluated the basic characteristics and efficacy of our newly developed patient fixation system for head and neck radiotherapy that uses a dedicated mouthpiece and dental impression materials. The present investigation demonstrated that with this system, the changes in the absorbed dose to water depending on the material of the mouthpiece were small, with a maximum of 0.32% for a 10-MV photon beam. For the dental impression material, we selected a silicone material with the lowest Hounsfield unit (HU) value that had little effect on the generation of artifacts and the quality of the X-ray beam. Multiphase magnetic resonance imaging (MRI) revealed that the head-up and -down motions in the thermoplastic shell without the mouthpiece were 5.76 ± 1.54 mm, whereas the motion with the mouthpiece decreased significantly to 1.72 ± 0.92 mm (P = 0.006). Similarly, the head-left and -right motion displacement decreased from 6.32 ± 1.86 mm without the mouthpiece to 1.80 ± 0.42 mm with the mouthpiece (P = 0.003). Regarding the tongue depressor function of the mouthpiece, the median distance from the hard palate to the surface of the tongue was 28.42 mm. The present results indicate that the new immobilization device developed herein that uses a mouthpiece and a thermoplastic shell is useful for suppressing patients' head motions and tongue positions.


Assuntos
Neoplasias de Cabeça e Pescoço , Materiais para Moldagem Odontológica , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Pescoço , Planejamento da Radioterapia Assistida por Computador/métodos , Silicones , Água
5.
J Radiat Res ; 63(4): 699-705, 2022 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-35575580

RESUMO

This study used cine-magnetic resonance imaging (cine-MRI) to evaluate the safety and efficacy of a novel airbag system combined with a shell-type body fixation system in reducing respiratory motion in normal volunteers. The airbag system consists of a six-sided polygon inflatable airbag, a same shape plate, a stiff air supply tube, an air-supply pump and a digital pressure load cell monitor. Piezoelectric sensors were installed in the plate to detect compression pressure load changes; pressure load data were transferred to the digital pressure load cell monitor through Bluetooth. Five volunteers underwent cine-MRI with and without airbag compression to detect differences in the respiratory motion of the organs. The volunteers' physiologic signs were stable during the experiment. The maximum inspiration pressure load was 4.48 ± 0.86 kgf (range, 4.00-6.00 kgf), while the minimum expiration pressure load was 3.69 ± 0.95 kgf (range, 2.8-5.3 kgf). Under airbag compression, the right diaphragm movement was reduced from 19.50 ± 6.43 mm to 9.60 ± 3.61 mm (P < 0.05) in the coronal plane and 23.12 ± 6.30 mm to 11.00 ± 3.69 mm (P < 0.05) in the sagittal plane. The left diaphragm, pancreas and liver in the coronal plane and the right kidney and liver in the sagittal plane also showed significant movement reduction. This novel airbag abdominal compression system was found to be safe during the experiment and successful in the reduction of internal organ respiratory motion and promises to be a convenient and efficient tool for clinical radiotherapy.


Assuntos
Air Bags , Respiração , Abdome , Voluntários Saudáveis , Humanos , Imageamento por Ressonância Magnética/métodos , Movimento (Física)
6.
Igaku Butsuri ; 40(1): 28-34, 2020.
Artigo em Japonês | MEDLINE | ID: mdl-32238680

RESUMO

In 2016, the American Association of Physicists in Medicine (AAPM) has published a report of task group (TG) 100 with a completely new concept, entitled "application of risk analysis methods to radiation therapy quality management." TG-100 proposed implementation of risk analysis in radiotherapy to prevent harmful radiotherapy accidents. In addition, it enables us to conduct efficient and effective quality management in not only advanced radiotherapy such as intensity-modulated radiotherapy and image-guided radiotherapy but also new technology in radiotherapy. It should be noted that treatment process in modern radiotherapy is absolutely more complex and it needs skillful staff and adequate resources. TG-100 methodology could identify weakness in radiotherapy procedure through assessment of failure modes that could occur in overall treatment processes. All staff in radiotherapy have to explore quality management in radiotherapy safety.


Assuntos
Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Humanos , Risco , Estados Unidos
7.
Igaku Butsuri ; 32(4): 176-81, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-24568022

RESUMO

We report the discovery of abnormal fluctuations in the output obtained when measuring a water phantom and adjustments that reduce these outliers. Using a newly developed three-dimensional scanning water phantom system, we obtained the depth dose and off-axis dose ratio required for the beam data of a medical linear accelerator (LINAC). The field and reference detectors were set such that the measured values could be viewed in real time. We confirmed the scanning data using the field detector and the change in the output using the reference detector while measuring by using the water phantom. Prior to output adjustment of the LINAC, we observed output abnormalities as high as 18.4%. With optimization of accelerator conditions, the average of the output fluctuation width was reduced to less than +/-0.5%. Through real-time graphing of reference detector measurements during measurement of field detector, we were able to rapidly identify abnormal fluctuations. Although beam data collected during radiation treatment planning are corrected for output fluctuations, it is possible that sudden abnormal fluctuations actually occur in the output. Therefore, the equipment should be tested for output fluctuations at least once a year. Even after minimization of fluctuations, we recommend determining the potential dose administered to the human body taking into account the width of the output fluctuation.


Assuntos
Imageamento Tridimensional , Aceleradores de Partículas/instrumentação , Imagens de Fantasmas , Radiometria/instrumentação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação , Água , Humanos , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...