Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Phys Med ; 33: 146-151, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28089191

RESUMO

The present study aimed to investigate whether the in-plane resolution property of iterative reconstruction (IR) of computed tomography (CT) data is object shape-dependent by testing columnar shapes with diameters of 3, 7, and 10cm (circular edge method) and a cubic shape with 5-cm side lengths (linear edge method). For each shape, objects were constructed of acrylic (contrast in Hounsfield units [ΔHU]=120) as well as a soft tissue equivalent material (ΔHU=50). For each shape, we measured the modulation transfer functions (MTFs) of IR and filtered back projection (FBP) using two multi-slice CT scanners at scan doses of 5 and 10mGy. In addition, we evaluated a thin metal wire using the conventional method at 10mGy. For FBP images, the MTF results of the tested objects and the wire method showed substantial agreement, thus demonstrating the validity of our analysis technique. For IR images, the MTF results of different shapes were nearly identical for each object contrast and dose combination, and we did not observe shape-dependent effects of the resolution properties of either tested IR. We conclude that both the circular edge method and linear edge method are equally useful for evaluating the resolution properties of IRs.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Imagens de Fantasmas , Doses de Radiação
2.
J Med Imaging (Bellingham) ; 2(2): 024002, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26158097

RESUMO

An image-processing technique for separating bones from soft tissue in static chest radiographs has been developed. The present study was performed to evaluate the usefulness of dynamic bone images in quantitative analysis of rib movement. Dynamic chest radiographs of 16 patients were obtained using a dynamic flat-panel detector and processed to create bone images by using commercial software (Clear Read BS, Riverain Technologies). Velocity vectors were measured in local areas on the dynamic images, which formed a map. The velocity maps obtained with bone and original images for scoliosis and normal cases were compared to assess the advantages of bone images. With dynamic bone images, we were able to quantify and distinguish movements of ribs from those of other lung structures accurately. Limited rib movements of scoliosis patients appeared as a reduced rib velocity field, resulting in an asymmetrical distribution of rib movement. Vector maps in all normal cases exhibited left/right symmetric distributions of the velocity field, whereas those in abnormal cases showed asymmetric distributions because of locally limited rib movements. Dynamic bone images were useful for accurate quantitative analysis of rib movements. The present method has a potential for an additional functional examination in chest radiography.

3.
Phys Med Biol ; 60(10): N209-18, 2015 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-26153580

RESUMO

The bone suppression technique based on advanced image processing can suppress the conspicuity of bones on chest radiographs, creating soft tissue images obtained by the dual-energy subtraction technique. This study was performed to evaluate the usefulness of bone suppression image processing in image-guided radiation therapy. We demonstrated the improved accuracy of markerless motion tracking on bone suppression images. Chest fluoroscopic images of nine patients with lung nodules during respiration were obtained using a flat-panel detector system (120 kV, 0.1 mAs/pulse, 5 fps). Commercial bone suppression image processing software was applied to the fluoroscopic images to create corresponding bone suppression images. Regions of interest were manually located on lung nodules and automatic target tracking was conducted based on the template matching technique. To evaluate the accuracy of target tracking, the maximum tracking error in the resulting images was compared with that of conventional fluoroscopic images. The tracking errors were decreased by half in eight of nine cases. The average maximum tracking errors in bone suppression and conventional fluoroscopic images were 1.3 ± 1.0 and 3.3 ± 3.3 mm, respectively. The bone suppression technique was especially effective in the lower lung area where pulmonary vessels, bronchi, and ribs showed complex movements. The bone suppression technique improved tracking accuracy without special equipment and implantation of fiducial markers, and with only additional small dose to the patient. Bone suppression fluoroscopy is a potential measure for respiratory displacement of the target.


Assuntos
Movimento (Física) , Intensificação de Imagem Radiográfica/métodos , Radiografia Torácica/métodos , Radioterapia Guiada por Imagem/métodos , Software , Osso e Ossos/diagnóstico por imagem , Humanos , Técnica de Subtração
4.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 70(11): 1297-303, 2014 Nov.
Artigo em Japonês | MEDLINE | ID: mdl-25410337

RESUMO

The purpose of this study was to evaluate the dose output according to the object using organ-based tube-current modulation in thoracic CT. The output doses with elliptical and circular shaped phantoms were measured using an ionizing CT chamber. The image noise was quantitatively measured in images obtained from the elliptical phantom. Although total dose outputs with and without the modulation were almost the same, dose outputs at a frontal angle of 120° decreased and those at another angle of 240° increased with the modulation. When the same-shaped phantoms were used, the differences in variation of dose outputs due to the difference in phantom size were small and those due to the difference in the percentage ratio of long- to short-axis diameter of the cross-section were large. There was no significant difference in the amount of noise with and without the dose modulation except for the case of overdose to the small phantom. Therefore, organ-based tube current modulation does not change the total dose output and it maintains the amount of noise by controlling the dose output for each projection angle. Additionally, this dose control is independent of the object size.


Assuntos
Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Doses de Radiação , Radiografia Torácica/instrumentação , Tomografia Computadorizada por Raios X/instrumentação
5.
J Appl Clin Med Phys ; 13(5): 3959, 2012 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-22955662

RESUMO

One-hundred-and-twenty-eight-section dual X-ray source computed tomography (CT) systems have been introduced into clinical practice and have been shown to increase temporal resolution. Higher temporal resolution allows low-dose spiral mode at a high pitch factor during CT coronary angiography. We evaluated radiation dose and physical image qualities in CT coronary angiography by applying high-pitch spiral, step-and-shoot, and low-pitch spiral modes to determine the optimal acquisition mode for clinical situations. An anthropomorphic phantom, small dosimeters, a calibration phantom, and a microdisc phantom were used to evaluate the radiation doses absorbed by thoracic organs, noise power spectrums, in-plane and z-axis modulation transfer functions, slice sensitivity profiles, and number of artifacts for the three acquisition modes. The high-pitch spiral mode had the advantage of a small absorbed radiation dose, but provided low image quality. The low-pitch spiral mode resulted in a high absorbed radiation dose of approximately 200 mGy for the heart. Although the absorbed radiation dose was lower in the step-and-shoot mode than in the low-pitch spiral mode, the noise power spectrum was inferior. The quality of the in-plane modulation transfer function differed, depending on spatial frequency. Therefore, the step-and-shoot mode should be applied initially because of its low absorbed radiation dose and superior image quality.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Imagens de Fantasmas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomógrafos Computadorizados , Técnicas de Imagem de Sincronização Cardíaca , Doença da Artéria Coronariana/cirurgia , Feminino , Humanos , Doses de Radiação
6.
Artigo em Japonês | MEDLINE | ID: mdl-22516592

RESUMO

The purpose of this study was to evaluate the image quality of an iterative reconstruction method, the iterative reconstruction in image space (IRIS), which was implemented in a 128-slices multi-detector computed tomography system (MDCT), Siemens Somatom Definition Flash (Definition). We evaluated image noise by standard deviation (SD) as many researchers did before, and in addition, we measured modulation transfer function (MTF), noise power spectrum (NPS), and perceptual low-contrast detectability using a water phantom including a low-contrast object with a 10 Hounsfield unit (HU) contrast, to evaluate whether the noise reduction of IRIS was effective. The SD and NPS were measured from the images of a water phantom. The MTF was measured from images of a thin metal wire and a bar pattern phantom with the bar contrast of 125 HU. The NPS of IRIS was lower than that of filtered back projection (FBP) at middle and high frequency regions. The SD values were reduced by 21%. The MTF of IRIS and FBP measured by the wire phantom coincided precisely. However, for the bar pattern phantom, the MTF values of IRIS at 0.625 and 0.833 cycle/mm were lower than those of FBP. Despite the reduction of the SD and the NPS, the low-contrast detectability study indicated no significant difference between IRIS and FBP. From these results, it was demonstrated that IRIS had the noise reduction performance with exact preservation for high contrast resolution and slight degradation of middle contrast resolution, and could slightly improve the low contrast detectability but with no significance.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada Multidetectores/métodos , Imagens de Fantasmas
7.
J Appl Clin Med Phys ; 13(2): 3731, 2012 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-22402390

RESUMO

Recently, specific computed tomography (CT) scanners have been equipped with organ-based tube current modulation (TCM) technology. It is possible that organ-based TCM will replace the conventional dose-reduction technique of reducing the effective milliampere-second. The aim of this study was to determine if organ-based TCM could reduce radiation exposure to the breasts without compromising the image uniformity and beam hardening effect in thoracic CT examinations. Breast and skin radiation doses and the absorbed radiation dose distribution within a single section were measured with an anthropomorphic phantom and radiophotoluminescent glass dosimeters using four approaches to thoracic CT (reference, organ-based TCM, copper shielding, and the combination of the above two techniques, hereafter referred to as the combination technique). The CT value and noise level were measured using the same calibration phantom. Organ-based TCM and copper shielding reduced radiation doses to the breast by 23.7% and 21.8%, respectively. However, the CT value increased, especially in the anterior region, using copper shielding. In contrast, the CT value and noise level barely increased using organ-based TCM. The combination technique reduced the radiation dose to the breast by 38.2%, but greatly increased the absorbed radiation dose from the central to the posterior regions. Moreover, the CT value increased in the anterior region and the noise level increased by more than 10% in the entire region. Therefore, organ-based TCM can reduce radiation doses to breasts with only small increases in noise levels, making it preferable for specific groups of patients, such as children and young women.


Assuntos
Mama/efeitos da radiação , Imagens de Fantasmas , Proteção Radiológica , Radiografia Torácica , Tomografia Computadorizada por Raios X/instrumentação , Feminino , Humanos , Doses de Radiação
8.
Artigo em Japonês | MEDLINE | ID: mdl-22277816

RESUMO

We evaluated exposed-radiation doses on dual-source cardiac computed tomography (CT) examinations with prospective electrocardiogram (ECG)-gated fast dual spiral scans. After placing dosimeters at locations corresponding to each of the thoracic organs, prospective ECG-gated fast dual spirals and retrospective ECG-gated dual spiral scans were performed to measure the absorbed dose of each organ. In the prospective ECG-gated fast dual spiral scans, the average absorbed doses were 5.03 mGy for the breast, 9.96 mGy for the heart, 6.60 mGy for the lung, 6.48 mGy for the bone marrow, 9.73 mGy for the thymus, and 4.58 mGy for the skin. These values were about 5% of the absorbed doses for the retrospective ECG-gated dual spiral scan. However, the absorbed dose differed greatly at each scan, especially in the external organs such as the breast. For effective and safe use of the prospective ECG-gated fast dual spiral scan, it is necessary to understand these characteristics sufficiently.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Coronária/métodos , Eletrocardiografia/métodos , Tomografia Computadorizada Multidetectores/métodos , Doses de Radiação , Radiometria/métodos , Imagens de Fantasmas
9.
Radiol Phys Technol ; 4(1): 53-60, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20878510

RESUMO

Magnetic resonance imaging (MRI) is useful in the quantitative evaluation of brain atrophy, because the superior contrast resolution facilitates separation of the gray and white matter. Quantitative assessment of brain atrophy has mainly been performed by manual measurement, which requires considerable time and effort to determine the brain volume. Therefore, computer-aided quantitative measurement methods for the diagnosis of brain atrophy are required. We have developed a method of segmenting the cerebrum, cerebellum-brainstem, and temporal lobe simultaneously on MR images obtained in a single sequence. It is important to measure the volume of not only these regions but also the frontal lobe in clinical use. However, for segmenting the frontal lobe, it is necessary to identify the Sylvian fissure and the central sulcus, which represent boundaries. Here, we developed a method of identifying the central sulcus from MR images obtained with a 1.5 T MRI scanner. The brain and the cerebrospinal fluid (CSF) regions were segmented using semiautomated segmentation method on MR images. The central sulcus shows an oblique line from the inside to the outside on the convexity view. The almost straight appearance of the central sulcus was used for segmentation of the central sulcus from the segmented CSF images. The central sulcus was identified with this technique in 77% of the images obtained by all sequences. This technique for identifying the central sulcus is very important not only for volumetry, but also for clinical diagnosis.


Assuntos
Córtex Cerebral/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Idoso , Idoso de 80 Anos ou mais , Atrofia/diagnóstico , Córtex Cerebral/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
10.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 64(11): 1352-60, 2008 Nov 20.
Artigo em Japonês | MEDLINE | ID: mdl-19060429

RESUMO

MR imaging (MRI) is an important method for the diagnosis of abnormalities of the brain. In the present report, a semi-automated method is presented to segment the brain and CSF region on brain MR images. MR images were obtained from 6 subjects by SE sequence and 8 subjects by GRE sequence. The semi-automated method consisted of the following three steps: (1) segmentation of the intracranial region using the region-growing technique, (2) segmentation of the brain region using histogram analysis and mathematical morphology, and (3) segmentation of the CSF region using the top-hat transformation technique. The average ratio of a correctly recognized region (CRR) between the semi-automated method and manual method was 87.9%, 85.1% for the intracranial region (IRR), and 94.8% and 86.8% for the brain region in the SE and GRE sequences.


Assuntos
Encéfalo/anatomia & histologia , Líquido Cefalorraquidiano , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Humanos , Masculino , Matemática , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...