Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Spine Surg ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38637917

RESUMO

STUDY DESIGN: Case report and literature review. OBJECTIVE: To report the relatively rare complication of delayed infection after cervical disc arthroplasty (CDA). BACKGROUND: Delayed infection of the M6 device has been a rarely reported complication, with all cases described outside of the United States. The reliability of positive intraoperative cultures remains an ongoing debate. METHODS: Cases were reviewed, and findings were summarized. A literature review was performed and discussed, with special consideration to current reports of delayed M6 infection, etiology, and utility of intraoperative cultures. RESULTS: We present a case of delayed infection 6 years after primary 1-level CDA with the M6 device. At revision surgery, gross purulence was encountered. Intraoperative cultures finalized with Staphylococcus epidermidis and Cutibacterium acnes. The patient was revised with removal of the M6 and conversion to anterior cervical discectomy and fusion. A prolonged course of intravenous antibiotics was followed by an oral course for suppression. At the final follow-up, the patient's preoperative symptoms had resolved. CONCLUSION: Delayed infection after CDA is a rare complication, with ongoing debate regarding the reliability of positive cultures. We describe an infected M6 and demonstrate the utility of implant removal, conversion to anterior cervical discectomy and fusion, and long-term antibiotics as definitive treatment. LEVEL OF EVIDENCE: Level V-case report and literature review.

2.
Am J Sports Med ; 52(3): 832-844, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37092718

RESUMO

The purpose of this current concepts review is to highlight the evaluation and workup of hamstring injuries, nonoperative treatment options, and surgical decision-making based on patient presentation and injury patterns. Hamstring injuries, which are becoming increasingly recognized, affect professional and recreational athletes alike, commonly occurring after forceful eccentric contraction mechanisms. Injuries occur in the proximal tendon at the ischial tuberosity, in the muscle belly substance, or in the distal tendon insertion on the tibia or fibula. Patients may present with ecchymoses, pain, and weakness. Magnetic resonance imaging remains the gold standard for diagnosis and may help guide treatment. Treatment is dictated by the specific tendon(s) injured, tear location, severity, and chronicity. Many hamstring injuries can be successfully managed with nonoperative measures such as activity modification and physical therapy; adjuncts such as platelet-rich plasma injections are currently being investigated. Operative treatment of proximal hamstring injuries, including endoscopic or open approaches, is traditionally reserved for 2-tendon injuries with >2 cm of retraction, 3-tendon injuries, or injuries that do not improve with 6 months of nonoperative management. Acute surgical treatment of proximal hamstring injuries tends to be favorable. Distal hamstring injuries may initially be managed nonoperatively, although biceps femoris injuries are frequently managed surgically, and return to sport may be faster for semitendinosus injuries treated acutely with excision or tendon stripping in high-level athletes.


Assuntos
Lesões dos Tecidos Moles , Traumatismos dos Tendões , Humanos , Traumatismos dos Tendões/diagnóstico , Traumatismos dos Tendões/cirurgia , Tendões , Atletas , Tomada de Decisões
3.
J ISAKOS ; 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38042407

RESUMO

OBJECTIVE: To review and update the literature regarding outcomes following surgical management of chronic, grade III posterolateral corner (PLC) injuries, with an emphasis on estimating failure rates based upon objective parameters in light of the 2019 expert consensus, while secondarily comparing the failure rates of anatomic versus non-anatomic reconstruction techniques. METHODS: A literature search was performed using the PubMed, Embase, MEDLINE, and Cochrane Library databases. Inclusion criteria consisted of level I-IV human clinical studies reporting subjective and objective outcomes in patients following surgical management for chronic (>6 weeks from injury) grade III PLC injuries, with a minimum two-year follow-up. The criterion for objective surgical failure was based on post-operative varus stress radiographs and defined as a side-to-side difference of 3 â€‹mm or more of lateral gapping. RESULTS: A total of six studies, consisting of 10 separate cohorts encompassing a total of 230 patients, were identified. PLC reconstruction was performed in all cohorts, with 80 â€‹% (n â€‹= â€‹8/10) of these cohorts utilising an anatomic reconstruction technique. A failure rate ranging from 4.3 â€‹% to 36 â€‹% was found. Subgroup analysis revealed a failure rate of 4.3 â€‹%-24.2 â€‹% for anatomic reconstruction techniques, whereas a 0 â€‹%-36 â€‹% failure rate was found for non-anatomic reconstruction. Arthrofibrosis was the most common complication (range, 0 â€‹%-12.1 â€‹%) following surgery. 0 â€‹%-8 â€‹% of patients required revision PLC surgery. CONCLUSION: PLC reconstruction yields a wide variability in failure rates according to the side-to-side difference of 3 â€‹mm or more of lateral gapping on post-operative varus stress radiographs, with low revision rates following anatomic and non-anatomic reconstruction techniques. LEVEL OF EVIDENCE: IV; Systematic Review of Level III and IV studies.

4.
Arthrosc Sports Med Rehabil ; 5(4): 100749, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37520504

RESUMO

Purpose: To evaluate reported clinical outcomes and complications following radiofrequency (RF) ablation for the treatment of knee chondral lesions. Methods: A literature search was performed according to the 2020 Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines by querying EMBASE, PubMed, and Scopus computerized databases from database inception through October 2022. Level I to IV clinical studies that reported outcomes or complications following RF-based chondroplasty were included. Postoperative outcome scores and complications were aggregated. Study quality was assessed via the Newcastle-Ottawa Scale. Results: Ten articles from 2002 to 2018 consisting of 1,107 patients (n = 1,504 lesions) were identified. Four studies were of Level I evidence, 3 studies were Level II, 1 study was Level III, and 2 studies were Level IV. The mean patient age was 41.8 ± 6.3 years (range, 12-87). Seven studies (n = 1,037 patients) used bipolar RF devices, and 3 studies (n = 70 patients) used monopolar RF devices. The overall mean postoperative Lysholm, Tegner, and IKDC scores ranged from 83 to 91, 3.8 to 7, and 49 to 90, respectively, in lesions ranging from grade I-IV according to the Outerbridge Classification. Monopolar RF devices reported qualitatively similar mean changes in Lysholm scores (83), Tegner scores (3.8), and IKDC scores (range, 49-69) compared with bipolar RF devices (range, 86.4-91, 4.5-7, 90, respectively). The incidence of complications ranged from 0% to 4%. The most commonly reported complication was osteonecrosis (range, 0% to 4%). The incidence rate of patients undergoing additional surgery ranged from 0% to 4.5%. Conclusions: The available literature on RF-based chondroplasty shows its efficacy and safety for the treatment of knee chondral lesions, with good clinical outcome scores and low complication and reoperation rates. Level of Evidence: Level IV, systematic review of Level I-IV studies.

5.
Arthrosc Sports Med Rehabil ; 5(4): 100754, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37448756

RESUMO

Purpose: To systematically examine the effects of radiofrequency (RF) ablation or coblation (controlled ablation) on chondrocyte viability following knee chondroplasty in preclinical literature to determine the effectiveness and safety of RF-based techniques. Methods: A literature search was performed in September 2022 using PubMed and Scopus using the following search terms combined with Boolean operators: "chondroplasty," "radiofrequency," "thermal," "knee," "chondral defect," "articular cartilage," and "cartilage." The inclusion criteria consisted of preclinical studies examining the effect of RF ablation or coblation on chondrocytes during knee chondroplasty. Exclusion criteria consisted of studies reporting chondroplasty in joints other than the knee, clinical studies, in vitro studies using animal models, case reports, non-full-text articles, letters to editors, surveys, review articles, and abstracts. The following data were extracted from the included articles: author, year of publication, chondral defect location within the knee and chondral characteristics, RF probe characteristics, cartilage macroscopic description, microscopic chondrocyte description, and extracellular matrix characteristics. Results: A total of 17 articles, consisting of 811 cartilage specimens, were identified. The mean specimen age was 63.4 ± 6.0 (range, 37-89) years. Five studies used monopolar RF devices, 7 studies used bipolar RF devices, whereas 4 studies used both monopolar and bipolar RF devices. Time until cell death during ablation at any power was reported in 5 studies (n = 351 specimens), with a mean time to cell death of 54.4 seconds (mean range, 23.1-64) for bipolar RF and 56.3 seconds (mean range, 12.5-64) for monopolar RF devices. Chondrocyte cell death increased with increased wattage, while treatment time was positively correlated with deeper cell death. Conclusions: In this systematic review, histologic analysis demonstrated that RF-based chondroplasty creates a precise area of targeted chondrocyte death, with minimal evidence of necrosis outside the target zone. Caution must be exercised when performing RF-based chondroplasty due to the risk of cell death with increased application time and wattage. Clinical Relevance: Although RF ablation has demonstrated favorable results in preliminary trials, including smoother cartilage and less damage to the surrounding healthy tissue, the risks versus benefits of the procedure are largely unknown. Caution must be exercised when performing RF-based chondroplasty in the clinical setting due to the risk of cell death with increased application time and wattage.

6.
Arthroscopy ; 39(5): 1310-1319.e2, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36657648

RESUMO

PURPOSE: To compare clinical and radiologic outcomes following superior capsular reconstruction (SCR) using dermal allograft versus tensor fascia lata (TFL) autograft for massive rotator cuff tears with a minimum 2-year follow-up. METHODS: A literature search was performed by querying Scopus, EMBASE, and PubMed computerized databases from database inception through September 2022 in accordance with the 2020 Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Studies evaluating clinical and radiologic outcomes, as well as complications following SCR for the treatment of massive rotator cuff tears were included. Study quality was assessed via the Newcastle-Ottawa Scale and the National Institutes of Health Quality Assessment. The mean change from preoperative to postoperative values (delta) was calculated for each outcome. RESULTS: Seventeen studies, consisting of 519 patients were identified. Mean duration of follow-up ranged from 24 to 60 months. Mean reduction in visual analog scale pain score ranged from 2.9 to 5.9 points following use of dermal allograft, and 3.4 to 7.0 points following TFL autograft reconstruction. Mean improvements in American Shoulder and Elbow Surgeons score were similar between groups (dermal allograft: 28.0-61.6; TFL autograft: 24.7-59.3). The mean increase in forward flexion ranged from 31° to 38° with dermal allograft, versus 19° to 69° with TFL autograft. Average improvement in active external rotation with dermal allograft ranged from -0.4° to 11° and from 2° to 22.4° using TFL autograft. A similar change in acromiohumeral distance following SCR (dermal allograft: 0.9-3.2 mm; TFL autograft: 0.3-3.6 mm) was appreciated. The rate of complications within the dermal allograft group ranged from 4.5% to 38.2% versus 13.3% to 86.4% following TFL autograft. Failure rate ranged from 4.5 to 38.2% following dermal allograft versus 4.5 to 86.4% with TFL autograft. CONCLUSIONS: Acellular dermal allograft versus TFL autograft for SCR both demonstrate improved VAS and American Shoulder and Elbow Surgeons scores, with increased values in flexion and external rotation, and increased visual analog scale, although with high variability. Both grafts demonstrate high rates of complications and failures at minimum 2-year follow-up. LEVEL OF EVIDENCE: IV; systematic review of level II-IV studies.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Humanos , Lesões do Manguito Rotador/cirurgia , Articulação do Ombro/cirurgia , Fascia Lata/transplante , Autoenxertos , Amplitude de Movimento Articular , Artroscopia , Aloenxertos , Resultado do Tratamento
7.
J Shoulder Elbow Surg ; 31(11): 2308-2315, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35562031

RESUMO

BACKGROUND: Treatment of elbow instability remains challenging despite advancements in surgical techniques. The objective of this study was to evaluate obesity, advanced age or frailty, and altered cognitive function (because of mental handicap, stroke, dementia, or traumatic brain injury) as unique indications for the use of the internal joint stabilizer (IJS) to augment surgical treatment of elbow instability. METHODS: This was a retrospective review of all patients 18 years and older with elbow instability who were managed with an IJS along with standard measures of care for their specific injury, such as fracture fixation and collateral ligament reconstruction. Patients were excluded if they did not have a minimum follow-up of 3 months. All patients were treated by a single shoulder and elbow fellowship-trained orthopedic traumatologist at an urban university-based level 1 trauma center. RESULTS: Twenty-two patients were included in the study. Five patients were 60 years of age or older. Nine patients had a body mass index of 30 or greater. Five patients had a history of 1 or more cerebral insults or cognitive impairment. The majority of patients (21/22; 95%) regained elbow stability after the index surgery. At last follow-up, 14 of 22 patients (63%) regained a functional arc of motion, defined as at least 100° arc of motion, and 77% of patients had at least 90° of motion. Complications requiring revision surgery included culture-negative recurrent elbow instability (n = 1), deep infection (n = 1), and IJS failure without recurrent instability (n = 1). The IJS was removed in all 3 cases. Twelve patients underwent delayed IJS removal >2 months after the index surgery to grant additional time for bony and ligamentous healing and to permit secondary contracture release at the time of IJS removal. No complications were seen from delayed IJS removal. CONCLUSION: The IJS may be used to create elbow stability in complex patients, regardless of weight, frailty, cognitive function, neurologic insult, or other comorbidities. Unlike external fixation, the IJS does not require pin site care and is relatively light and low-profile. When augmenting surgical fixation for elbow instability, the IJS may be preferable for patients with complex comorbidities or social dynamics.


Assuntos
Articulação do Cotovelo , Fragilidade , Luxações Articulares , Instabilidade Articular , Fraturas do Rádio , Humanos , Cotovelo , Luxações Articulares/cirurgia , Fragilidade/complicações , Instabilidade Articular/etiologia , Amplitude de Movimento Articular , Radiografia , Recuperação de Função Fisiológica , Resultado do Tratamento , Estudos Retrospectivos , Fixação Interna de Fraturas/efeitos adversos , Fraturas do Rádio/cirurgia
8.
BMC Musculoskelet Disord ; 23(1): 470, 2022 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-35590311

RESUMO

BACKGROUND: Septic arthritis of the native shoulder is traditionally diagnosed with the same strategies as knee or hip septic arthritis. However, septic arthritis of the shoulder is frequently a missed or delayed diagnosis. Reliance on aspiration and serum markers has been called into question recently. The purpose of this study was to conduct a systematic review investigating the value of joint aspiration and serum markers in the diagnosis of native shoulder joint sepsis. METHODS: PubMed/MEDLINE, Scopus, and the Cochrane Library were used in the systematic literature search from January 1, 1960, through January 23, 2021. The primary outcome was to report on the synovial white cell count of patients with native shoulder sepsis. Descriptive statistics using percentages, means, and intraclass correlation coefficient (ICC) values were used to summarize the results. RESULTS: Thirty-one studies, including 25 case series, one case-control, and five cohort studies with a total of 7434 native shoulder joints, were included. There was no standardized approach to diagnosing septic arthritis of the shoulder. Only 10 studies (32%) reported on synovial white cell count with the majority yielding aspiration counts greater than 50,000 cells/mm3, although one study was as low as 30,000 cells/mm3. CONCLUSIONS: The diagnosis of native shoulder joint sepsis lacks uniformity. Methods used to evaluate shoulder sepsis are heterogeneous and may lead to delays or misdiagnosis with devastating sequelae. Synovial white cell count is underutilized and may also present with a lower value than expected, which is likely related to the time interval between symptom onset and diagnosis.


Assuntos
Artrite Infecciosa , Sepse , Articulação do Ombro , Artrite Infecciosa/diagnóstico , Biomarcadores , Humanos , Estudos Retrospectivos , Sepse/diagnóstico , Ombro , Líquido Sinovial
9.
Int Orthop ; 46(5): 1111-1122, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35187589

RESUMO

This review paper on femoral neck fractures in the elderly provides updated information from the most recent literature and examines the advantages and disadvantages of different surgical treatment options. Femoral neck fractures are a common injury that many orthopaedic surgeons will encounter within their practice. These injuries are associated with significant morbidity, and the economic impact of surgically fixing these fractures is notable. Contemporary treatment options include internal fixation, hemiarthroplasty, and total hip arthroplasty. For non-displaced fractures, both internal fixation and hemiarthroplasty remain feasible options. Hemiarthroplasty decreases re-operation rate, while internal fixation decreases operative time, blood loss, and infection risk. Newly designed fixation constructs require further investigation. For displaced fractures, the literature strongly supports arthroplasty. Most elderly patients with displaced femoral neck fractures should be managed with a hemiarthroplasty. In select active elderly patients, total hip arthroplasty may achieve favourable early functional outcomes as compared to a hemiarthroplasty. Finally, cemented arthroplasty decreases periprosthetic fracture risk as compared to cementless arthroplasty. However, experienced arthroplasty surgeons with significant expertise in press-fitting techniques may achieve similar outcomes with cementless arthroplasty.


Assuntos
Artroplastia de Quadril , Fraturas do Colo Femoral , Hemiartroplastia , Fraturas Periprotéticas , Idoso , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Fraturas do Colo Femoral/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Hemiartroplastia/efeitos adversos , Hemiartroplastia/métodos , Humanos , Fraturas Periprotéticas/cirurgia , Resultado do Tratamento
10.
JSES Rev Rep Tech ; 2(2): 219-229, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-37587970

RESUMO

The main goal of treatment for chronically unreduced elbow dislocations is to restore a stable, concentric joint and regain a satisfactory arc of motion. Due to the conflicting goals of restoring elbow stability and regaining a good arc of motion, the treatment of chronic elbow dislocation remains a challenge for even the experienced orthopedic surgeon. The standard treatment of these dislocations consists of open reduction, V-Y muscleplasty of the triceps, and temporary arthrodesis or cast immobilization. However, prolonged postoperative immobilization may result in elbow stiffness, which significantly limits the functional outcome. We present our surgical technique with a focus on restoring stable reduction such that early motion can be instituted and complications of prolonged immobilization can be avoided. From position to wound closure, surgical steps are presented in detail, with pearls for practice and a discussion on chronic elbow dislocation. The internal joint stabilizer is a safe and effective implant that complements the management of chronic elbow dislocations. This reproducible surgical technique allows for stability and early mobility while having the added benefit of circumventing complications associated with prolonged immobilization and hinged external fixation. Understanding the surgical indications, as well as the nuances of the surgical technique utilizing the internal joint stabilizer, is critical in order to improve patient outcomes and avoid complications.

12.
J Orthop Trauma ; 36(3): 111-117, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34483327

RESUMO

OBJECTIVES: To analyze the current incidence of postoperative infection for OTA/AO type C fractures of the tibial plateau and tibial plafond. DATA SOURCES: Three medical databases: PubMed/MEDLINE, ScienceDirect, and the Cochrane Library, were used in our systematic literature search. Search results were restricted to articles transcribed in English/Spanish and publication date after January 1, 2000, to present day. STUDY SELECTION: Inclusion criteria were studies reporting postoperative infection data for OTA/AO type 41C, 43C, or equivalent fractures of skeletally mature individuals. A minimum of 6 total fractures of interest and a frequency of 75% overall were required. Studies reporting on pathologic fractures, stress fractures, or low-energy fracture types were excluded. DATA EXTRACTION: Two authors independently screened abstracts, evaluated full-text manuscripts, and extracted relevant data from included studies. Any instances of discrepancy were resolved within the study committee by consensus. DATA SYNTHESIS: Outcomes were expressed using direct proportions (PR) with a 95% confidence interval. The effects of comorbidities on infection rates were reported using odds ratios with a 95% confidence interval. All analyses used a DerSimonian-Laird estimate with a random-effects model based on heterogeneity. The presence of publication bias was evaluated using funnel plots and Egger's tests. CONCLUSIONS: Patients with these specific fractures develop infections at a notable frequency. The rates of deep infections were approximately 6% in tibial plateau fractures and 9% in tibial plafond fractures. These results may be useful as a reference for patient counseling and other future studies aimed at minimizing postoperative infection for these injuries. LEVEL OF EVIDENCE: Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Fraturas do Tornozelo , Fraturas da Tíbia , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Humanos , Incidência , Estudos Retrospectivos , Infecção da Ferida Cirúrgica/epidemiologia , Fraturas da Tíbia/epidemiologia , Fraturas da Tíbia/cirurgia
13.
J Shoulder Elbow Surg ; 31(1): 107-112, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34174450

RESUMO

BACKGROUND: Plating midshaft clavicle fractures anteriorly is gaining popularity because of low complication rates. Improvements in plate fixation constructs for midshaft clavicle fractures have unclear clinical significance. The purpose of this study was to present the early clinical and radiographic outcomes of pre-contoured titanium anterior plates for the treatment of midshaft clavicle fractures. METHODS: Skeletally mature patients who underwent plate fixation of a midshaft clavicular fracture from 2008 to 2015 using pre-contoured titanium anterior plates were included in this retrospective investigation. The primary outcome measures were union rate and hardware removal rate. The secondary outcome measures included reoperation for all causes and mechanical implant failure. RESULTS: A total of 26 patients were included. Complete healing occurred in 96% of patients without further surgical intervention, and all patients achieved union. Medical complications occurred in 2 patients (7.7%), consisting of cellulitis (n = 1) and chronic pain (n = 1). In 1 patient (3.8%), delayed union occurred and the use of a bone stimulator was required postoperatively to achieve union. Finally, 2 patients (7.7%) had symptomatic implants that required removal. CONCLUSIONS: In the acute fracture setting, the anterior plating system used in this study led to a high rate of union with decreased rates of implant irritation. Only 7.7% of patients required hardware removal for symptomatic hardware, as opposed to the estimated 20%-60% reported in the literature in patients with symptomatic superior clavicle plates.


Assuntos
Clavícula , Fraturas Ósseas , Placas Ósseas , Clavícula/diagnóstico por imagem , Clavícula/cirurgia , Fixação Interna de Fraturas , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Humanos , Estudos Retrospectivos , Titânio , Resultado do Tratamento
14.
J Clin Med ; 10(21)2021 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-34768533

RESUMO

Macro- and micronutrients play important roles in the biological wound-healing pathway. Although deficiencies may potentially affect orthopaedic trauma patient outcomes, data on nutritional deficiencies in orthopaedic trauma patients remain limited in the literature. The purpose of this study was to (1) evaluate the prevalence of macro- and micronutrient deficiencies in orthopaedic trauma patients with lower extremity fractures and (2) evaluate the impact of such deficiencies on surgical site complications. This retrospective study identified 867 patients with lower extremity fractures treated with surgical fixation from 2019 to 2020. Data recorded included albumin, prealbumin, protein, vitamins A/C/D, magnesium, phosphorus, transferrin and zinc, as well as wound complications. Nutritional deficiencies were found for prealbumin, albumin and transferrin at 50.5%, 23.4% and 48.5%, respectively. Furthermore, a high prevalence of micronutrient deficiencies (vitamin A, 35.4%; vitamin C, 54.4%; vitamin D, 75.4%; and zinc, 56.5%) was observed. We also recorded a statistically significant difference in wound complications in patients who were deficient in prealbumin (21.6% vs. 6.6%, p = 0.0142) and vitamin C (56.8% vs. 28.6%, p = 0.0236). Our study outlines the prevalence of nutritional deficiencies in an orthopaedic trauma population and identifies areas for possible targeted supplementation to decrease wound complications.

15.
Case Rep Orthop ; 2021: 8522303, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34580615

RESUMO

Essex-Lopresti injuries and terrible triad injuries of the elbow are rare injuries that typically result from high-energy trauma such as falling from a height or a motor vehicle collision. However, the combination of an Essex-Lopresti injury and terrible triad injury is unique and poses a significant challenge for treatment as these injuries are independently associated with poor functional outcomes if they are not acutely diagnosed. We describe a case of a 19-year-old who presented with an unusual variant of a terrible triad injury associated with an Essex-Lopresti injury. The patient had a distal radioulnar joint (DRUJ) and elbow dislocation, a radial head and coronoid process fracture, and a distal radius fracture. Almost a reverse Essex-Lopresti, this injury was successfully managed with open reduction and repair of the distal radius, radial head, and damaged ligaments in the elbow, along with an internal joint stabilizer (IJS).

16.
J Health Care Poor Underserved ; 32(2): 1059-1068, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34120993

RESUMO

PURPOSE: To evaluate if income status affects the timing of presentation to orthopaedic care, surgical treatment, or continuity of care following a closed ankle fracture. METHODS: Th is retrospective study identified 434 patients with closed ankle fractures treated with operative fixation from 2014 to 2016. Median income data were extracted using the patients' ZIP codes and data from the U.S. Census Bureau. RESULTS: Lower-income patients presented to the hospital and received surgical treatment significantly later than others. They were also more often uninsured and nonadherent with postoperative weightbearing precautions. Additionally, these patients less frequently sought care on the day of their injury, and they had both shorter inpatient stays and duration of overall follow-up in comparison with others. CONCLUSION: Socioeconomic status is a vital consideration for improving patient access to acute orthopaedic surgical care. Lower-income patients are more susceptible to multiple time-sensitive delays in their care, and these patients frequently encounter difficulties maintaining appropriate follow-up carex.


Assuntos
Fraturas do Tornozelo , Ortopedia , Hospitais , Humanos , Pessoas sem Cobertura de Seguro de Saúde , Estudos Retrospectivos , Resultado do Tratamento
17.
World Neurosurg ; 130: e417-e422, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31247356

RESUMO

OBJECTIVES: To describe the learning curve of pedicle screw placement using robot-assisted spine surgery of an experienced neurosurgeon and 2 supervised neurosurgical fellows. METHODS: The first 120 cases of robot-assisted spine surgery at our institution were assessed. Patient variables included age, body mass index, and indication for surgery. Intraoperative variables included the vertebral level of screw placement, number of screws placed by each operator, intraoperative blood loss, and operative time. Postoperative variables included length of stay, discharge disposition, 30-day readmissions, wound complications, and hardware revisions. Screw accuracy was determined with image overlay analysis comparing planned screw trajectory on the navigation software with the intraoperative computed tomography scan with final screw placement. Two-dimensional accuracy was determined for the tip of the screw, tail of the screw, and angle at the screw was placed. The supervising physician and first fellow began utilizing the robot concurrently upon its arrival, and the second fellow began using the robot after the system had been in place for 7 months. RESULTS: Both experienced surgeon and first fellow displayed a learning curve and achieved statistically significant improvement of accuracy after 30 screws. The second fellow had significantly better accuracy than the experienced surgeon in his first 30 screws. There were no complications from hardware placement in either group. There were no returns to the operating room for hardware issues. CONCLUSIONS: Robot-assisted spine surgery is a safe, accurate method of pedicle screw instrumentation. Our data show similar learning adaptation rates for the first fellow and the experienced surgeon. Techniques learned by the attending surgeon were immediately transferable to a new learner, who was able to achieve a faster learning curve than both the first fellow and the experienced surgeon.


Assuntos
Procedimentos Neurocirúrgicos/educação , Procedimentos Ortopédicos/educação , Procedimentos Cirúrgicos Robóticos/educação , Idoso , Competência Clínica , Humanos , Internato e Residência , Curva de Aprendizado , Pessoa de Meia-Idade , Neurocirurgiões/educação , Parafusos Pediculares , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...