1.
Ann Med Surg (Lond) ; 76: 103541, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35495410

RESUMO

Objective: Dialysis efficacy is one of the important issues in patients undergoing hemodialysis. This study aimed to determine the adequacy of dialysis with mortality and hospital admissions in patients undergoing hemodialysis. Methods: This retrospective cohort study was conducted on patients who underwent dialysis. Dialysis adequacy was measured based on the Kt/V criterion. Age, sex, disease etiology, duration of dialysis, and access dialysis were evaluated. Results: 128 patients with a mean age of 61.48 ± 13.36 years were included in the study. 8 patients had a history of kidney transplantation. The mean dialysis time in the patients was 4.30 ± 3.39 years. The mean Kt/V in the patients was 1.40 ± 1.8 years. Of the 128 patients, 53 were hospitalized for cardiac or renal reasons. The number of fatalities was 9 cases out of 128. The cause of death in all the cases was heart problems. There was a statistically significant correlation between the adequacy of dialysis in terms of Kt/V and mortality, but it was not associated with hospitalization. Conclusion: Inadequate dialysis in terms of Kt/V is likely to increase the rate of mortality among dialysis patients.