Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Comput Assist Tomogr ; 46(1): 17-22, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35099132

RESUMO

OBJECTIVE: This study aimed to compare the performance of deep learning image reconstruction (DLIR) with that of standard filtered back projection (FBP) and adaptive statistical iterative reconstruction V (ASiR-V) for measurement of the vascular diameter on computed tomography (CT) angiography model. METHODS: We used 6 vascular models of 3 wall thicknesses. We used DLIR, FBP, and ASiR-V for reconstruction, and compared the accuracy and precision of vascular diameter measurement, as well as the image noise, among the 3 reconstruction methods. RESULTS: Image noise was in the order of FBP > ASiR-V > DLIR. The vascular diameters measured using DLIR and ASiR-V were comparable with, or significantly closer to, the actual diameter than those measured using FBP. The precision of the diameter measurement using DLIR was comparable with or significantly superior to that using FBP/ASiR-V. CONCLUSIONS: Use of DLIR, as compared with FBP or ASiR-V, for image reconstruction can improve the precision and accuracy of vascular diameter measurement.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Aprendizado Profundo , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Modelos Cardiovasculares , Imagens de Fantasmas
2.
Jpn J Radiol ; 40(1): 94-102, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34304382

RESUMO

PURPOSE: The purpose of the study is to evaluate the effect of energy level on the modulation transfer functions (MTF) and noise power spectra (NPS) of virtual monochromatic images (VMIs) obtained using four types of computed-tomographic (CT) scanners: Revolution, SOMATOM, IQon, and Aquilion. MATERIALS AND METHODS: VMIs were obtained at 70, 60, and 50 kiloelectron volts (keV), and also at the lowest keV available in each scanner. We evaluated the MTF and NPS in the VMIs obtained at each keV. RESULTS: No significant effect of the energy level on the MTF was observed in IQon, whereas the spatial resolution decreased as the energy level decreased in the other types of scanners. The NPS curves tended to increase as the energy levels decreased with three types of scanners other than Aquilion. CONCLUSION: The spatial resolution and noise frequency characteristics of VMIs may be affected by the energy level, and the effects of energy level on these characteristics differ depending on the type of CT scanners.


Assuntos
Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Razão Sinal-Ruído , Tomógrafos Computadorizados
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...