Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 89(5): 053702, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29864796

RESUMO

In neutral helium atom microscopy, a beam of atoms is scanned across a surface. Though still in its infancy, neutral helium microscopy has seen a rapid development over the last few years. The inertness and low energy of the helium atoms (less than 0.1 eV) combined with a very large depth of field and the fact that the helium atoms do not penetrate any solid material at low energies open the possibility for a non-destructive instrument that can measure topology on the nanoscale even on fragile and insulating surfaces. The resolution is determined by the beam spot size on the sample. Fast resolution change is an attractive property of a microscope because it allows different aspects of a sample to be investigated and makes it easier to identify specific features. However up till now it has not been possible to change the resolution of a helium microscope without breaking the vacuum and changing parts of the atom source. Here we present a modified source design, which allows fast, step wise resolution change. The basic design idea is to insert a moveable holder with a series of collimating apertures in front of the source, thus changing the effective source size of the beam and thereby the spot size on the surface and thus the microscope resolution. We demonstrate a design with 3 resolution steps. The number of resolution steps can easily be extended.

2.
Rev Sci Instrum ; 87(2): 023102, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931829

RESUMO

Time-of-flight (TOF) is a standard experimental technique for determining, among others, the speed ratio S (velocity spread) of a molecular beam. The speed ratio is a measure for the monochromaticity of the beam and an accurate determination of S is crucial for various applications, for example, for characterising chromatic aberrations in focussing experiments related to helium microscopy or for precise measurements of surface phonons and surface structures in molecular beam scattering experiments. For both of these applications, it is desirable to have as high a speed ratio as possible. Molecular beam TOF measurements are typically performed by chopping the beam using a rotating chopper with one or more slit openings. The TOF spectra are evaluated using a standard deconvolution method. However, for higher speed ratios, this method is very sensitive to errors related to the determination of the slit width and the beam diameter. The exact sensitivity depends on the beam diameter, the number of slits, the chopper radius, and the chopper rotation frequency. We present a modified method suitable for the evaluation of TOF measurements of high speed ratio beams. The modified method is based on a systematic variation of the chopper convolution parameters so that a set of independent measurements that can be fitted with an appropriate function are obtained. We show that with this modified method, it is possible to reduce the error by typically one order of magnitude compared to the standard method.

3.
Rev Sci Instrum ; 84(9): 093303, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24089819

RESUMO

Low energy (thermal) free jet (supersonic) molecular beams are used in a range of applications from surface science and surface deposition to quantum coherence and gas kinetics experiments. A free jet molecular beam is created by a gas expansion from a high pressure reservoir through a small aperture (nozzle). The nozzle typically has a diameter of 2-20 µm. The central part of the beam is selected using a skimmer, typically up to 500 µm in diameter. Recent years have seen the introduction of highly spatially confined beam sources based on micrometer skimmers and micrometer or even sub-micrometer nozzles. Such sources have been applied, for example, in the investigation of superfluidity and in neutral helium microscopy. However, up till now no source design allowing the precise positioning of the micro-skimmer relative to the nozzle has been available. This is an important issue because the relative position of skimmer and nozzle can influence the beam properties considerably. Here we present the design and implementation of a new molecular beam source, which allows an automatized, 50 nm precision positioning of the skimmer relative to the nozzle. The source is liquid nitrogen cooled and the temperature can be controlled between 110 K and 350 K with a temperature fluctuation of less than ±0.1 K over several hours. Beam intensity measurements using a 5 µm nozzle and a skimmer 5 µm in diameter are presented for stagnation pressures po in the range 3-180 bars. A 2D beam profile scan, using a 9.5 µm skimmer and a 5 µm nozzle is presented as a further documentation of the versatility of the new design and as an illustration of the influence of the relative skimmer-nozzle position on the beam properties.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA