Physiol Meas ; 29(4): 497-513, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18401070

RESUMO

Temporal variability of parameters which describe dynamic cerebral autoregulation (CA), usually quantified by the short-term relationship between arterial blood pressure (BP) and cerebral blood flow velocity (CBFV), could result from continuous adjustments in physiological regulatory mechanisms or could be the result of artefacts in methods of measurement, such as the use of non-invasive measurements of BP in the finger. In 27 subjects (61+/-11 years old) undergoing coronary artery angioplasty, BP was continuously recorded at rest with the Finapres device and in the ascending aorta (Millar catheter, BP(AO)), together with bilateral transcranial Doppler ultrasound in the middle cerebral artery, surface ECG and transcutaneous CO(2). Dynamic CA was expressed by the autoregulation index (ARI), ranging from 0 (absence of CA) to 9 (best CA). Time-varying, continuous estimates of ARI (ARI(t)) were obtained with an autoregressive moving-average (ARMA) model applied to a 60 s sliding data window. No significant differences were observed in the accuracy and precision of ARI(t) between estimates derived from the Finapres and BP(AO). Highly significant correlations were obtained between ARI(t) estimates from the right and left middle cerebral artery (MCA) (Finapres r=0.60+/-0.20; BP(AO) r=0.56+/-0.22) and also between the ARI(t) estimates from the Finapres and BP(AO) (right MCA r=0.70+/-0.22; left MCA r=0.74+/-0.22). Surrogate data showed that ARI(t) was highly sensitive to the presence of noise in the CBFV signal, with both the bias and dispersion of estimates increasing for lower values of ARI(t). This effect could explain the sudden drops of ARI(t) to zero as reported previously. Simulated sudden changes in ARI(t) can be detected by the Finapres, but the bias and variability of estimates also increase for lower values of ARI. In summary, the Finapres does not distort time-varying estimates of dynamic CA obtained with a sliding window combined with an ARMA model, but further research is needed to confirm these findings in healthy subjects and to assess the influence of different physiological manoeuvres.


Assuntos
Pressão Sanguínea/fisiologia , Circulação Cerebrovascular/fisiologia , Homeostase/fisiologia , Idoso , Algoritmos , Angioplastia Coronária com Balão , Simulação por Computador , Interpretação Estatística de Dados , Feminino , Dedos/irrigação sanguínea , Humanos , Masculino , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional/fisiologia , Reprodutibilidade dos Testes
2.
Physiol Meas ; 27(12): 1387-402, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17135707

RESUMO

Estimates of cerebral critical closing pressure (CrCP) and resistance-area product (RAP) are often derived using noninvasive measurements of arterial blood pressure (ABP) in the finger, but the errors introduced by this approach, in relation to intra-vascular measurements of ABP, are not known. Continuous recordings of ABP (Finapres and solid-state catheter-tip transducer in the ascending aorta), cerebral blood flow velocity (CBFV, bilateral Doppler), ECG and transcutaneous CO(2) were performed following coronary catheterization. CrCP and RAP were calculated for each of 12,784 cardiac cycles from 27 subjects using the classical linear regression (LR) of the instantaneous CBFV-ABP relationship and also the first harmonic (H(1)) of the Fourier transform. There was a better agreement between LR and H(1) for the aortic measurements than for the Finapres (p < 0.000,01). For LR there were no significant differences for either CrCP or RAP due to the source of ABP measurement, but for H(1) the differences were highly significant (p < 0.000,03). The coherence functions between either CrCP or RAP values calculated with aortic pressure (input) or the Finapres (output) were significantly higher for H(1) than for LR for most harmonics below 0.2 Hz. When using the Finapres to estimate CrCP and RAP values, the LR method produces similar results to intra-arterial measurements of ABP for time-averaged values, but H(1) should be preferred in applications analysing beat-to-beat changes in these parameters.


Assuntos
Resistência das Vias Respiratórias/fisiologia , Cavidade Nasal/fisiologia , Obstrução das Vias Respiratórias/diagnóstico , Obstrução das Vias Respiratórias/fisiopatologia , Humanos , Reprodutibilidade dos Testes , Mecânica Respiratória , Músculos Respiratórios/fisiologia