Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 11(1): 6859, 2021 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-33767209

RESUMO

Unabated, worldwide trends in CO2 production project growth to > 43-BMT per year over the next two decades. Efficient power electronics are crucial to fully realizing the CO2 mitigating benefits of a worldwide smart grid (~ 18% reduction for the United States alone). Even state-of-the-art SiC high voltage junction devices are inefficient because of slow transition times (~ 0.5-µs) and limited switching rates at high voltage (~ 20-kHz at ≥ 15-kV) resulting from the intrinsically limited charge carrier drift speed (< 2 × 107-cm-s-1). Slow transition times and limited switch rates waste energy through transition loss and hysteresis loss in external magnetic components. Bulk conduction devices, where carriers are generated and controlled nearly simultaneously throughout the device volume, minimize this loss. Such devices are possible using below bandgap excitation of semi-insulating (SI) SiC single crystals. We explored carrier dynamics with a 75-fs single wavelength pump/supercontinuum probe and a modified transient spectroscopy technique and also demonstrated a new class of efficient, high-speed, high-gain, bi-directional, optically-controlled transistor-like power device. At a performance level six times that of existing devices, for the first time we demonstrated prototype operation at multi-10s of kW and 20-kV, 125-kHz in a bulk conduction transistor-like device using direct photon-carrier excitation with below bandgap light.

2.
Phys Med ; 24(2): 98-101, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18430600

RESUMO

A novel compact CT-guided intensity modulated proton radiotherapy (IMPT) system is described. The system is being designed to deliver fast IMPT so that larger target volumes and motion management can be accomplished. The system will be ideal for large and complex target volumes in young patients. The basis of the design is the dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL). The DWA uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system will produce individual pulses that can be varied in intensity, energy and spot width. The IMPT planning system will optimize delivery characteristics. The system will be capable of being sited in a conventional linac vault and provide intensity modulated rotational therapy. Feasibility tests of an optimization system for selecting the position, energy, intensity and spot size for a collection of spots comprising the treatment are underway. A prototype is being designed and concept designs of the envelope and environmental needs of the unit are beginning. The status of the developmental new technologies that make the compact system possible will be reviewed. These include, high gradient vacuum insulators, solid dielectric materials, SiC photoconductive switches and compact proton sources.


Assuntos
Aceleradores de Partículas/instrumentação , Terapia com Prótons , Radioterapia de Intensidade Modulada/instrumentação , Fenômenos Biofísicos , Biofísica , Desenho de Equipamento , Humanos , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X
3.
Rev Sci Instrum ; 78(12): 123504, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18163729

RESUMO

The LLNL Crystal Driven Neutron Source is operational and has produced record ion currents of approximately 10 nA and neutron output of 1.9(+/-0.3)x10(5) per thermal cycle using a crystal heating rate of 0.2 degrees C/s from 10 to 110 degrees C. A 3 cm diameter by 1 cm thick LiTaO(3) crystal with a socket secured field emitter tip is thermally cycled with feedback control for ionization and acceleration of deuterons onto a deuterated target to produce D-D fusion neutrons. The entire crystal and temperature system is mounted on a bellows which allows movement of the crystal along the beam axis and is completely contained on a single small vacuum flange. The modular crystal assembly permitted experimental flexibility. Operationally, flashover breakdowns along the side of the crystal and poor emitter tip characteristics can limit the neutron source. The experimental neutron results extend earlier published work by increasing the ion current and pulse length significantly to achieve a factor-of-two higher neutron output per thermal cycle. These findings are reviewed along with details of the instrument.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...