Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Heliyon ; 9(8): e18966, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37609391

RESUMO

Introduction: Optimizing nutritional support helps prevent extra uterine growth restriction and adverse long-term outcomes in preterm infants. Objectives: This study aimed to analyze the incidence of and risk factors for hyperglycemia and hypoglycemia in preterm infants receiving early-aggressive parenteral nutrition (PN). Methods: This prospective observational study included preterm infants receiving PN at the Neonatal Intensive Care Unit of Dr. Soetomo General Hospital between April 2018 and May 2019. Potential risk factors analyzed included asphyxia, sepsis, respiratory distress syndrome, multiple congenital anomalies, mortality, necrotizing enterocolitis, retinopathy of prematurity, the postoperative period, inotropic administration, glucose infusion rate (GIR) > 10-12 mg/kg/min, GIR 4-<5.5 mg/kg/min, and increase in GIR <1 mg/kg/min. Results: Of the 105 preterm infants included, hyperglycemia and hypoglycemia were found in 14 (13.3%) and 26 (24.8%) infants, respectively, with most incidents occurring in the first week (hyperglycemia: 85.7%; hypoglycemia: 88.5%). Sepsis was an independent risk factor for hyperglycemia (odds ratio [OR]: 8.743, 95% confidence interval [CI]: 2.392-31.959; P = 0.001). Hypoglycemia independent risk factors included the postoperative period (OR: 4.425, 95% CI: 1.218-16.073; P = 0.024) and use of GIR 4-<5.5 mg/kg/min (OR: 2.950, 95% CI: 1.035-8.405; P = 0.043). Conclusion: Hyperglycemia and hypoglycemia can occur in preterm infants receiving early-aggressive PN; most cases occur within the first week of life. Hypoglycemia correlated with low glucose intake, and hyperglycemia correlated with sepsis. Monitoring blood glucose levels in preterm infants receiving PN, especially in the first weeks of life, may decrease morbidity associated with hyperglycemia or hypoglycemia.

2.
PLoS One ; 18(5): e0285128, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37130099

RESUMO

Hyperbilirubinemia is more frequently seen in low and middle-income countries like Indonesia. One of the contributing factors is a substandard dose of Phototherapy irradiance. This research aims to design a phototherapy intensity meter called PhotoInMeter using readily available low-cost components. PhotoInMeter is designed by using a microcontroller, light sensor, color sensor, and an ND (neutral-density) filter. We use machine learning to create a mathematical model that converts the emission from the color sensor and light sensor into light intensity measurements that are close to Ohmeda Biliblanket's measurements. Our prototype collects sensor reading data and pairs them with Ohmeda Biliblanket Light Meter to create a training set for our machine learning algorithm. We create a multivariate linear regression, random forest, and XGBoost model based on our training set to convert sensor readings to Ohmeda Biliblanket Light Meter measurement. We successfully devised a prototype that costs 20 times less to produce compared to our reference intensity meter while still having high accuracy. Compared to Ohmeda Biliblanket Light Meter, our PhotoInMeter has a Mean Absolute Error (MAE) of 0.83 and achieves more than a 0.99 correlation score in all six different devices for intensity in the range of 0-90 µW/cm2/nm. Our prototypes show consistent reading between PhotoInMeter devices, having an average difference of 0.435 among all six devices.


Assuntos
Hiperbilirrubinemia , Fototerapia , Humanos , Indonésia , Modelos Lineares , Aprendizado de Máquina
3.
J Pediatr (Rio J) ; 99(5): 432-442, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37094752

RESUMO

OBJECTIVE: The incidence and prevalence of inflammatory bowel disease (IBD) in pediatric patients are increasing. Currently, the diagnostic method for IBD is inconvenient, expensive, and difficult. S100A12, a type of calcium-binding protein, detected in the feces of patients with IBD has recently been suggested as a promising diagnostic tool. Hence, the authors aimed to evaluate the accuracy of fecal S100A12 in diagnosing IBD in pediatric patients by performing a meta-analysis. METHODS: The authors performed a systematic literature search in five electronic databases for eligible studies up to July 15, 2021. Pooled diagnostic accuracies of fecal S100A12 were analyzed as the primary outcomes. Secondary outcomes were standardized mean difference (SMD) of fecal S100A12 levels between IBD and non-IBD groups and a comparison of diagnostic accuracies between fecal S100A12 and fecal calprotectin. RESULTS: Seven studies comprising 712 children and adolescents (474 non-IBD controls and 238 IBD cases) were included. Fecal S100A12 levels were higher in the IBD group than in the non-IBD group (SMD = 1.88; 95% confidence interval [CI] = 1.19-2.58; p < 0.0001). Fecal S100A12 could diagnose IBD in pediatric patients with a pooled sensitivity of 95% (95% CI = 88%-98%), specificity of 97% (95% CI = 95%-98%), and area under the receiver operating summary characteristics (AUSROC) curve of 0.99 (95% CI = 0.97-0.99). Fecal S100A12 specificity and AUSROC curve values were higher than those of fecal calprotectin (p < 0.05). CONCLUSION: Fecal S100A12 may serve as an accurate and non-invasive tool for diagnosing pediatric IBD.


Assuntos
Doenças Inflamatórias Intestinais , Proteína S100A12 , Adolescente , Criança , Humanos , Proteína S100A12/análise , Biomarcadores/análise , Doenças Inflamatórias Intestinais/diagnóstico , Complexo Antígeno L1 Leucocitário/análise , Complexo Antígeno L1 Leucocitário/metabolismo , Fezes/química
4.
Heliyon ; 9(1): e12980, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36820170

RESUMO

Background: Neonatal mortality is one of the key impediments in achieving global sustainable development goals, especially in lower middle income countries (LMICs). As an LMIC with the highest reported neonatal mortality rate in Southeast Asia, Indonesia faces inequitable distribution of health facilities across the archipelago. Therefore, in this paper, we aim to evaluate the determinants of neonatal mortality rate in Indonesia to search for better strategies to overcome this problem. Methods: We conducted an analysis of the 2017 Indonesia Demographic Health Survey dataset of 10,838 live-born infants born from singleton pregnancies in 2017. Using a hierarchical approach, multivariate analysis was conducted to identify potential factors (including socioeconomic, household, and proximate determinants) that contributed to neonatal mortality. Results: The lack of participation in postnatal care [odds ratio (OR) = 20.394, p = 0.01)] and delivery complications other than prolonged labour (OR = 2.072, p = 0.02) were the maternal factors that significantly associated with increased risk of neonatal death. Regarding neonatal factors, low-birth-weight infants appeared to be more vulnerable to neonatal death (OR = 12.489, p = 0.01). Conclusion: Low participation in postnatal care, development of labour complications, and low birth weight were associated with higher neonatal mortality. It implies that in a limited resource and geographically challenging country such as Indonesia, improving the quality and optimizing services of public hospitals with equitable distribution of quality health care services in all regions should be prioritized in the efforts of reducing neonatal mortality rate.

5.
J. pediatr. (Rio J.) ; 99(5): 432-442, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1514451

RESUMO

Abstract Objective: The incidence and prevalence of inflammatory bowel disease (IBD) in pediatric patients are increasing. Currently, the diagnostic method for IBD is inconvenient, expensive, and difficult. S100A12, a type of calcium-binding protein, detected in the feces of patients with IBD has recently been suggested as a promising diagnostic tool. Hence, the authors aimed to evaluate the accuracy of fecal S100A12 in diagnosing IBD in pediatric patients by performing a meta-analysis. Methods: The authors performed a systematic literature search in five electronic databases for eligible studies up to July 15, 2021. Pooled diagnostic accuracies of fecal S100A12 were analyzed as the primary outcomes. Secondary outcomes were standardized mean difference (SMD) of fecal S100A12 levels between IBD and non-IBD groups and a comparison of diagnostic accuracies between fecal S100A12 and fecal calprotectin. Results: Seven studies comprising 712 children and adolescents (474 non-IBD controls and 238 IBD cases) were included. Fecal S100A12 levels were higher in the IBD group than in the non-IBD group (SMD = 1.88; 95% confidence interval [CI] = 1.19-2.58; p < 0.0001). Fecal S100A12 could diagnose IBD in pediatric patients with a pooled sensitivity of 95% (95% CI = 88%-98%), specificity of 97% (95% CI = 95%-98%), and area under the receiver operating summary characteristics (AUSROC) curve of 0.99 (95% CI = 0.97-0.99). Fecal S100A12 specificity and AUSROC curve values were higher than those of fecal calprotectin (p < 0.05). Conclusion: Fecal S100A12 may serve as an accurate and non-invasive tool for diagnosing pediatric IBD. © 2023 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. This is an open access article under the CC BY-NC-ND license (https://creativecommons.org/licenses/by-nc-nd/4.0/).

6.
F1000Res ; 11: 1534, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-38025296

RESUMO

Background: Neonatal hyperbilirubinemia is one of the most common conditions for neonate inpatients. Indonesia faces a major challenge in which different guidelines regarding the management of this condition were present. This study aimed to compare the existing guidelines regarding prevention, diagnosis, treatment and monitoring in order to create the best recommendation for a new hyperbilirubinemia guideline in Indonesia. Methods: Through an earlier survey regarding adherence to the neonatal hyperbilirubinemia guideline, we identified that three main guidelines are being used in Indonesia. These were developed by the Indonesian Pediatric Society (IPS), the Ministry of Health (MoH), and World Health Organization (WHO). In this study, we compared factors such as prevention, monitoring, methods for identifying, risk factors in the development of neonatal jaundice, risk factors that increase brain damage, and intervention treatment threshold in the existing guidelines to determine the best recommendations for a new guideline. Results: The MoH and WHO guidelines allow screening and treatment of hyperbilirubinemia based on visual examination (VE) only. Compared with the MoH and WHO guidelines, risk assessment is comprehensively discussed in the IPS guideline. The MoH guideline recommends further examination of an icteric baby to ensure that the mother has enough milk without measuring the bilirubin level. The MoH guideline recommends referring the baby when it looks yellow on the soles and palms. The WHO and IPS guidelines recommend combining VE with an objective measurement of transcutaneous or serum bilirubin. The threshold to begin phototherapy in the WHO guideline is lower than the IPS guideline while the exchange transfusion threshold in both guidelines are comparably equal. Conclusions: The MoH guideline is outdated. MoH and IPS guidelines are causing differences in approaches to the management hyperbilirubinemia. A new, uniform guideline is required.


Assuntos
Hiperbilirrubinemia Neonatal , Icterícia Neonatal , Recém-Nascido , Humanos , Criança , Indonésia , Hiperbilirrubinemia Neonatal/diagnóstico , Hiperbilirrubinemia Neonatal/terapia , Icterícia Neonatal/terapia , Fototerapia/efeitos adversos , Bilirrubina
7.
F1000Res ; 11: 520, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-37476818

RESUMO

Background: Optimal neonatal resuscitation requires knowledge and experience on the part of healthcare personnel. This study aims to assess the readiness of hospital healthcare personnel to perform neonatal resuscitation. Methods: This was an observational study conducted in May 2021 by distributing questionnaires to nurses, midwives, doctors, and residents to determine the level of knowledge and experience of performing neonatal resuscitation. Questionnaires were adapted from prior validated questionnaires by Jukkala AM and Henly SJ. We conducted the research in four types of hospitals A, B, C, and D, which are defined by the Regulation of the Minister of Health of the Republic of Indonesia. Type A hospitals have the most complete medical services, while type D hospitals have the least medical services. The comparative analysis between participants' characteristics and the knowledge or experience score was conducted. Results: A total of 123 and 70 participants were included in the knowledge and experience questionnaire analysis, respectively. There was a significant difference (p = 0.013) in knowledge of healthcare personnel between the type A hospital (median 15.00; Interquartile Range [IQR] 15.00-16.00) and type C hospital (median 14.50; IQR 12.25-15.75). In terms of experience, the healthcare personnel of type A (median 85.00; IQR 70.00-101.00) and type B (median 92.00; IQR 81.00-98.00) hospitals had significantly (p =0,026) higher experience scores than the type D (median 42.00; IQR 29.00-75.00) hospital, but we did not find a significant difference between other type of hospitals. Conclusions: In this study, we found that the healthcare personnel from type A and type B hospitals are more experienced than those from type D hospitals in performing neonatal resuscitation. We suggest that a type D hospital should refer the neonate to a type A or type B hospital if there is sufficient time in cases of risk at need for resuscitation.


Assuntos
Médicos , Ressuscitação , Humanos , Recém-Nascido , Estudos Transversais , Recursos Humanos em Hospital , Atenção à Saúde
8.
Neonatology ; 118(6): 678-684, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34818231

RESUMO

BACKGROUND: Recently, the Bilistick®, a point-of-care instrument to measure bilirubin levels, has been developed. It is fast and cheaper than transcutaneous bilirubin (TCB)-measuring devices, but data on diagnostic properties are scarce. OBJECTIVE: This study aimed to compare the performance of the Bilistick® (BM-BS 1.0 - FW version 2.0.1) and the JM-105 bilirubinometer for measuring bilirubin. METHOD: This is a prospective study in infants born after ≥32 weeks' gestation, and/or a birth weight of ≥1,500 g, and a postnatal age ≤14 days in Surabaya, Indonesia. Bilirubin was measured with the Bilistick® System (BM-BS 1.0 - FW version 2.0.1), transcutaneously (TCB) with the JM-105 bilirubinometer, and in serum (TSB) with a routine laboratory technique. Mean differences and 95% limits of agreement (LOA) and correlations were calculated. RESULT: We enrolled 149 neonates and 126 had paired measurements of Bilistick® bilirubin, TCB, and TSB. Bilistick® failed in 16 (10.7%) infants. Mean Bilistick® bilirubin-TSB difference was -11 µmol/L (95% LOA: -101 to 79 µmol/L) and r = 0.738 (p < 0.001). Mean TCB-TSB difference was 26 µmol/L (95% LOA: -33 to 88) and r = 0.785 (p < 0.001). The sensitivity, specificity, PPV, and NPV for Bilistick® bilirubin for a TSB above treatment thresholds were 0.74, 0.84, 0.67, and 0.88, respectively, and for TCB 0.92, 0.64, 0.54, and 0.95, respectively. CONCLUSION: The Bilistick® System (BM-BS 1.0 - FW version 2.0.1) underestimates TSB, whereas TCB overestimates TSB in jaundiced Indonesian infants. Further improvement of Bilistick®'s diagnostic accuracy with less false-negative readings is essential to increase its use.


Assuntos
Bilirrubina , Icterícia Neonatal , Humanos , Lactente , Recém-Nascido , Triagem Neonatal/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos
9.
Artigo em Inglês | MEDLINE | ID: mdl-34200369

RESUMO

Background: In some hospitals in low/middle-income countries, methods to determine the bilirubin level in newborn infants are unavailable and based on a clinical evaluation, namely a clinical score designed by Kramer. In this study, we evaluated if this score can be used to identify those infants that need phototherapy. Method: Infants admitted between November 2018 and June 2019 to three hospitals in Surabaya, Indonesia were included. The jaundice intensity was scored using the Kramer score. Blood was sampled for total serum bilirubin (TSB) measurement. The infants were categorized into Treatment Needed (TN) group when treatment with phototherapy was indicated and the No Treatment Needed (NTN) group when phototherapy was not indicated, based on the Indonesian Guideline for hyperbilirubinemia. Result: A total of 280 infants with a mean birth weight of 2744.6 ± 685.8 g and a gestational age of 37.3 ± 2.3 weeks were included. Twenty-seven of 113 (24%) infants with Kramer score 2 needed phototherapy, compared with 41 of 90 (46%) infants with score 3 and 20 of 28 (71%) of infants with score 4. The percentage of infants that needed phototherapy was higher with decreasing gestational age. Conclusion: The Kramer score is an invalid method to distinguish between those infants needing phototherapy and those infants where this treatment is not indicated.


Assuntos
Icterícia Neonatal , Bilirrubina , Humanos , Hiperbilirrubinemia , Indonésia , Lactente , Recém-Nascido , Fototerapia
10.
F1000Res ; 9: 300, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33014346

RESUMO

Background: Hyperbilirubinemia is common in neonates, with higher prevalence among preterm neonates, which can lead to severe hyperbilirubinemia. Assessment of total serum bilirubin (TSB) and use of a transcutaneous bilirubinometer (TcB) are existing methods to identify and predict hyperbilirubinemia. This study aimed to determine TcB cut-off values during the first day for preterm neonates to predict hyperbilirubinemia at 48 and 72 hours. Methods: A total of 90 neonates born ≤35 weeks were included in the study. They were divided into two groups (Group I: 1000-1500 grams; Group II: 1501-2000 grams). The bilirubin level was measured on the sternum using TcB at the ages of 12, 24, and 72 h. TSB measurements were taken on the third day or if TcB level reached ± 1.24 mg/dL phototherapy threshold and if TcB showed abnormal results (Group I: 5.76-8.24 mg/dL; Group II: 8.76-11.24 mg/dL). Hyperbilirubinemia was defined as TSB ≥7 mg/dL for group I and >10 mg/dL for group II. Results: In total, 38 group I neonates and 48 group II neonates were observed. Almost half of neonates in group I (44.7%) were suffering from hyperbilirubinemia at the age of 48 hours, with 45.8% of group II at the age of 72 hours. To predict hyperbilirubinemia at the age of 48 hours, the best 24-hour-age TcB cut-off values were calculated to be 4.5 mg/dL for group I and 5.8 mg/dL for group II. To predict hyperbilirubinemia at the age of 72 hours, we determined 24-hour-age TcB value of 5.15 mg/dL for group II. Conclusion: TcB values in the early days of life can be used as hyperbilirubinemia predictors on the following days for preterm neonates. Close monitoring should be managed for those with TcB values higher than the calculated cut-off values.


Assuntos
Bilirrubina/sangue , Hiperbilirrubinemia , Estudos de Coortes , Humanos , Hiperbilirrubinemia/diagnóstico , Recém-Nascido , Recém-Nascido Prematuro , Fototerapia
11.
F1000Res ; 9: 1213, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33628433

RESUMO

Background: Circulating into foetal circulation across the placental barrier, abnormal maternal serum lipids predispose neonates to metabolic dysfunction and thereafter affect the steroid metabolism and functions of extra-embryonic foetal tissues. Methods: A systematic review was conducted by searching PubMed-MEDLINE and the Cochrane library between January 2010 and January 2020. The included studies were English case control studies that described original data on at least one raw lipid measurement during pregnancy in healthy women who delivered large for gestational age (LGA) newborns and in healthy women with non-LGA newborns. The data extracted from 12 studies were pooled, and the weighted mean difference (WMD) in lipid levels was calculated using random effects models. A meta-analysis was performed to identify sources of heterogeneity and to describe the significant value of the collected studies. Results: Of 649 published articles identified, a total of 12 met the inclusion criteria . Compared with women who had non-LGA newborns, those who had LGA newborns had significantly higher triglyceride (TG) levels (WMD = 0.28, 95% CI -0.02 to 0.54) and lower high density lipoprotein cholestrol (HDL-C) levels (WMD = 0.08, 95% CI -0.13 to -0.03), but not have significantly lower high-density lipoprotein cholesterol (LDL-C) levels. Moreover, the levels of total cholesterol, low-density lipoprotein cholesterol, and very low density lipoprotein cholesterol (VLDL-C) were inconsistent between both groups. Conclusions: High levels of TG and low levels of HDL-C could cause births of LGA newborns whereas maternal serum of TC, LDL-C and VLDL-C cannot be used as predictor of LGA.


Assuntos
Metabolismo dos Lipídeos , Gestantes , Peso ao Nascer , HDL-Colesterol , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Gravidez
12.
F1000Res ; 9: 1481, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-38107345

RESUMO

Background: Caesarean sections have become the most popular method for delivering twin babies because of the safety concerns associated with a natural birth. This study aims to identify the maternal characteristics and obstetric parameters that serve as risk factors influencing caesarean delivery in twin pregnancies by comparing women delivering via caesarean section and vaginal birth. Methods: A retrospective chart review design was used to analyse 47 women with multiple pregnancies from the medical records at a primary referral hospital in East Java, Indonesia. Women delivering vaginally were then compared with women who underwent a caesarean section to identify any differences between the groups. Results: In our study, more women delivered by caesarean section (n=35) than by vaginal birth (n=12). Women were more likely to undergo a caesarean section if they had a previous history of undergoing a caesarean section (OR 16.5; 95% CI 1.91-142.49; p=0.02). Similar to previous studies, we found that foetal malpresentation significantly increase the risk of caesarean delivery (OR 8.25; 95%CI 0.95-71.09; p=0.03), while labour augmentation decrease the likelihood of caesarean section (OR 0.20; 95% CI 0.49-0.81; p=0.03). There was also a significant older patients in the caesarean section groups (OR 1.26; 95% CI 1.09-1.45 ; p=0.00). Conclusions: The percentage of multiple pregnancies delivered via caesarean section is quite high. Other larger cohort study are warranted, since many factors were involved in the decision of caesarean section.


Assuntos
Cesárea , Trabalho de Parto Induzido , Gravidez , Humanos , Feminino , Cesárea/efeitos adversos , Indonésia/epidemiologia , Estudos Retrospectivos , Trabalho de Parto Induzido/efeitos adversos , Trabalho de Parto Induzido/métodos , Gravidez de Gêmeos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...