Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ophthalmology ; 104(7): 1126-30, 1997 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9224465

RESUMO

PURPOSE: Visual field assessment is extremely important in glaucoma management, but interpretation is affected by the quality of the patient's performance. The authors have investigated the reliability of visual field performance by a randomly selected sample of the chronic glaucoma population at an urban tertiary care practice. METHODS: Patient reliability in Humphrey automated visual field testing was studied in 106 randomly selected chronic open-angle glaucoma patient charts, which provided 768 tests (mean, 7.2 +/- 4.8 fields; range, 2-18 fields). Reliability criteria were established as less than 20% fixation losses, less than 33% false-negative error, and less than 33% false-positive error, as recommended by Humphrey Instruments, Inc (San Leandro, CA). RESULTS: Patients performed reliably in 61% of right eye fields, 58% of left eye fields, and 59.5% overall. Of the 106 patients, only 35 (33%) were always reliable in both eyes, whereas 8 (7.5%) were always unreliable in both eyes. The most common cause of unreliability was fixation loss (39%), whereas false-positive error (5%) and false-negative error (9%) were less frequent. A more severely depressed mean deviation correlated significantly with poorer performance on the three reliability indices, with false-negative error having the greatest correlation, followed by fixation loss and false-positive error. Corrected pattern standard deviation correlated closely only with false-negative error. Prolonged test time also correlated with all three reliability indices. Age was a significant factor for fixation loss but not for false-negative or false-positive error. CONCLUSIONS: The authors conclude that fewer than two thirds of the Humphrey visual fields were reliable with the authors' urban tertiary care population of patients with glaucoma. Relaxing the fixation loss criterion to less than 33% improved the rate of reliability to approximately 75%. The severity of glaucomatous visual field defects, test time, and age were identified as factors influencing the reliability of the Humphrey visual fields.


Assuntos
Glaucoma/fisiopatologia , Saúde da População Urbana , Testes Visuais/normas , Campos Visuais , Idoso , Idoso de 80 Anos ou mais , Envelhecimento/fisiologia , Automação , Estudos de Avaliação como Assunto , Reações Falso-Negativas , Reações Falso-Positivas , Feminino , Fixação Ocular , Humanos , Masculino , Pessoa de Meia-Idade
2.
Nucl Med Commun ; 17(2): 105-13, 1996 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-8778633

RESUMO

Accelerated coronary artery disease is a common complication following orthotopic cardiac transplantation. The relationship between acute rejection and accelerated coronary artery disease remains unclear. While thallium-201 (201Tl) imaging has been advocated in the diagnosis of post-transplant coronary arteriopathy, other investigators have found little role for this technique in the evaluation of such patients. We undertook a retrospective review of 13 stress/rest (10 exercise, 2 dobutamine, 1 dipyridamole) and 2 rest/rest 201Tl single photon emission tomographic (SPET) imaging studies performed in seven patients post-cardiac transplantation (mean duration post transplantation = 2.5 years). Four of these patients had serial studies with an average interval between studies of 8.3 months (range 3-14 months). Coronary angiography was performed within 12 months of each 201Tl study (mean = 4.2 months). Using the coronary angiographic diagnostic criterion of > or = 50% stenosis in one or more vessels, one or more fixed or reversible segmental defects were found on 201Tl imaging with a sensitivity of 78% and specificity of 33%. When the angiographic criterion of > 70% stenosis in one or more vessels was used the sensitivity increased to 100%, and where reversible segments were diagnostic the sensitivity was 67% and the specificity range from 42 to 58%. Although based on a small sample of patients, these results suggest that use of appropriate test methods and interpretive criteria may improve the utility of 201Tl SPET myocardial imaging in the diagnosis of coronary artery disease in cardiac transplant patients. Limited specificity may reflect associated pathological processes in these patients, including rejection, oedema and focal inflammation.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/etiologia , Transplante de Coração/efeitos adversos , Transplante de Coração/diagnóstico por imagem , Coração/diagnóstico por imagem , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Angiografia Coronária , Feminino , Rejeição de Enxerto/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA