Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Contemp Brachytherapy ; 12(6): 533-539, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33437300

RESUMO

PURPOSE: To evaluate clinical outcomes in patients with localized prostate cancer (LPC) treated with 3D conformal high-dose-rate (HDR) brachytherapy (BT) as monotherapy. MATERIAL AND METHODS: From March 2004 to November 2017, 277 men with LPC underwent 3D conformal HDR-BT as monotherapy, with a temporary implant. The dose prescription was: 38 Gy in 4 fractions (149 patients), 27 Gy in 2 fractions (41 patients), and 19-20 Gy in a single fraction (87 patients). Biochemical progression-free survival (bPFS), progression-free survival (PFS), and cancer-specific survival (CSS) were calculated. Acute and late genitourinary (GU) and gastrointestinal (GI) toxicity assessment were performed using Common Terminology Criteria for Adverse Events v5.0. RESULTS: The mean age was 67 (range, 47-81) years. Overall, 145 patients were low-risk, 116 intermediate-risk, and 16 high-risk prostate cancer. After a median follow-up of six years (range, 6-160 months), bPFS, PFS, and CSS were 81%, 96%, and 97%, respectively. Dose prescription, initial prostate specific antigen (iPSA) ≥ 9,5 ng/ml, and high-risk disease resulted in prognostic factors regarding bPFS. Only G2-G3 acute or late GI and GU toxicities were observed. CONCLUSIONS: HDR-BT as monotherapy is a valid and safe treatment modality for localized prostate cancer. After a long follow-up, patients receiving 19-20 Gy in a single fraction had a lower biochemical control rate compared to patients receiving 38 Gy in 4 fractions or 27 Gy in 2 fractions. Randomized prospective trials with a longer follow-up are necessary to confirm our results, and define total doses and dose per fraction for HDR-BT in patients with LPC.

2.
Phys Med ; 30(8): 973-9, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25113943

RESUMO

PURPOSE: To compare helical Tomotherapy (HT), two volumetric-modulated arc techniques and conventional fixed-field intensity modulated techniques (S-IMRT) for head-neck (HN) cancers. METHODS AND MATERIALS: Eighteen HN patients were considered. Four treatment plans were generated for each patient: HT, S-IMRT optimised with Eclipse treatment planning system and two volumetric techniques using Elekta-Oncentra approach (VMAT) and Varian-RapidArc (RA), using two full arcs. All techniques were optimised to simultaneously deliver 66Gy to PTV1 (GTV and enlarged nodes) and 54Gy to PTV2 (subclinical and electively treated nodes). Comparisons were assessed on several dosimetric parameters and, secondarily, on planned MUs and delivery time. RESULTS: Concerning PTV coverage, significantly better results were found for HT and RA. HT significantly improved the target coverage both compared to S-IMRT and VMAT. No significant differences were found between S-IMRT and volumetric techniques in terms of dose homogeneity. For OARs, all the techniques were able to satisfy all hard constraints; significantly better results were found for HT, especially in the intermediate dose range (15-30 Gy). S-IMRT reached a significantly better OARs sparing with respect to VMAT and RA. No significant differences were found for body mean dose, excepting higher values of V5-V10 for HT. A reduction of planned MUs and delivery treatment time was found with volumetric techniques. CONCLUSIONS: The objectives of satisfying target coverage and sparing of critical structures were reached with all techniques. S-IMRT techniques were found more advantageous compared to RA and VMAT for OARs sparing. HT reached the best overall treatment plan quality.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Radioterapia/métodos , Algoritmos , Encéfalo/efeitos da radiação , Relação Dose-Resposta à Radiação , Esôfago/efeitos da radiação , Humanos , Laringe/efeitos da radiação , Mandíbula/efeitos da radiação , Glândula Parótida/efeitos da radiação , Radiometria/métodos , Reprodutibilidade dos Testes , Medula Espinal/efeitos da radiação , Glândula Tireoide/efeitos da radiação
3.
Acta Oncol ; 50(1): 72-80, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20482224

RESUMO

BACKGROUND AND PURPOSE: to study the impact of the 4DCT imaging technique on radiotherapy planning for pancreatic carcinoma. To evaluate the possibility of IMRT/IGRT to increase the dose to PTV subvolume. MATERIAL AND METHODS: contrast-enhanced 4DCT scans of 15 patients (PTs) with unresectable pancreatic cancer were acquired. A 4DCT based PTV (4D-PTV) was created by the convolution of contours and then expanded for geometric uncertainties; a standard PTV (STD-PTV) was derived from a single CTV plus conventional margins. Two 3D conformal treatment (3DCRT) plans and one Helical Tomotherapy (HT) plan were generated with a prescription of 60 Gy. Regarding the 3DCRT plans, the 4D-PTV was considered as the target volume for one, and the STD-PTV for the other; the HT plans were performed only for 4D-PTV. Twelve of 15 PTs were admitted to a Phase I hypofractionated study (15 fractions). The prescribed dose was 44.25 Gy to the 4D-PTV and the PTV subvolume around vascular involvement was boosted from 50 to 55 Gy; before treatment, daily patient position was corrected using MVCT. RESULTS: 4D-PTVs were smaller than STD-PTVs with a volume reduction equal to 37%. 3DCRT plans on 4D-PTV showed a significant sparing of most OARs, the use of IMRT allowed a further significant dose reduction. In the Phase I study the PTV subvolume received up to 55 Gy with modest increase in dose to OARs. CONCLUSIONS: the 4DCT procedure decreases the overlap between PTV and OARs. HT technique, compared with 3DCRT, allows efficient dose sparing in particular for the duodenum. The IMRT/IGRT approach allows a safe dose escalation to PTV subvolume.


Assuntos
Tomografia Computadorizada Quadridimensional , Neoplasias Pancreáticas/radioterapia , Radioterapia de Intensidade Modulada , Adulto , Idoso , Duodeno/efeitos da radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neoplasias Pancreáticas/patologia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/efeitos adversos , Resultado do Tratamento
4.
Radiother Oncol ; 97(3): 525-9, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20826027

RESUMO

We compared customized ITVs obtained with CE-4D-CT imaging (ITV(4D)) with a population-based (ITV(PBC)) in 29 patients (PTs) and evaluated the intra-observer ITV delineation reproducibility in 5 PTs with unresectable pancreatic ductal adenocarcinoma (PDA). The ITV(PBC) was quite different from the ITV(4D), with under/over estimation of volume. Intra-observer volume delineation variability on CE-4D-CT and on a single-phase CE-CT were similar (27.6% vs 24.9%).


Assuntos
Carcinoma Ductal Pancreático/diagnóstico por imagem , Carcinoma Ductal Pancreático/radioterapia , Meios de Contraste , Tomografia Computadorizada Quadridimensional , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/radioterapia , Ácidos Tri-Iodobenzoicos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Planejamento da Radioterapia Assistida por Computador , Reprodutibilidade dos Testes , Respiração , Carga Tumoral
5.
Radiother Oncol ; 88(3): 310-8, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18692266

RESUMO

BACKGROUND AND PURPOSE: To investigate the impact of Helical Tomotherapy (HT) upon the dose distribution when compared to our routinely delivered 3D conformal radiotherapy (CRT) in the case of patients affected by stage III non-small-cell lung cancer (NSCLC). MATERIAL AND METHODS: Thirteen stage III inoperable NSCLC patients were scheduled to receive 61.2-70.2Gy, 1.8Gy/fraction. Two treatment techniques (HT and CRT) were considered, and in the case of CRT the dose calculation was performed using both the pencil beam (PB) and Anisotropic Analytical Algorithm (AAA) available on the Varian Eclipse planning system. Dose volume constraints for PTV coverage and OAR sparing were assessed for the HT inverse planning with the highest priority upon PTV coverage and spinal cord sparing. The three plans were compared in terms of dose-volume histograms (DVHs) and normal tissue complication probability (NTCP). A statistical analysis was performed using non-parametric Wilcoxon matched pairs tests. RESULTS: In CRT the use of a less accurate algorithm (PB) decreased the monitor unit number by 2.4%. HT significantly improved dose homogeneity within PTV compared with CRT_AAA. For lung parenchyma V20-V40 were lower with HT, corresponding to a decrease of 7% in the risk of radiation pneumonitis. The volume of the heart and esophagus irradiated to >45-60Gy were reduced using HT plans. For eight PTs with an esophagus-PTV overlap >5%, HT significantly reduced both late and acute esophageal complication probability. CONCLUSIONS: Our findings obtained in stage III NSCLC patients underline that HT guarantees an important sparing of lungs and esophagus, thus HT has the potential to improve therapeutic ratio, when compared with CRT, by means of dose escalation and/or combined treatment strategy. In CRT of locally advanced lung cancers, the use of a more advanced algorithm would give significantly better modeling of target dose and coverage.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Tomografia Computadorizada Espiral , Idoso , Algoritmos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estatísticas não Paramétricas , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...