Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Skin Therapy Lett ; 22(4): 7-9, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28732153

RESUMO

Hepatitis B virus (HBV) and hepatitis C virus (HCV) are common, worldwide viral illnesses that potentially impact the clinician's ability to manage patients with immunosuppressive medications such as biological therapy. In light of recent literature reviews, patients with HBV and HCV should be referred to a hepatologist or infectious disease expert prior to initiation of biological therapy.


Assuntos
Antivirais/uso terapêutico , Hepatite B/tratamento farmacológico , Hepatite C/tratamento farmacológico , Produtos Biológicos , Hepacivirus/efeitos dos fármacos , Hepatite B/etiologia , Vírus da Hepatite B/efeitos dos fármacos , Hepatite C/etiologia , Humanos
2.
Europace ; 18(11): 1740-1747, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26941338

RESUMO

AIMS: The subcutaneous implantable cardioverter-defibrillator (S-ICD) and leadless pacemaker (LP) are evolving technologies that do not require intracardiac leads. However, interactions between these two devices are unexplored. We investigated the feasibility, safety, and performance of combined LP and S-ICD therapy, considering (i) simultaneous device-programmer communication, (ii) S-ICD rhythm discrimination during LP communication and pacing, and (iii) post-shock LP performance. METHODS AND RESULTS: The study consists of two parts. Animal experiments: Two sheep were implanted with both an S-ICD and LP (Nanostim, SJM), and the objectives above were tested. Human experience: Follow-up of one S-ICD patient with bilateral subclavian occlusion who received an LP and two LP (all Nanostim, SJM) patients (without S-ICD) who received electrical cardioversion (ECV) are presented. Animal experiments : Simultaneous device-programmer communication was successful, but LP-programmer communication telemetry was temporarily lost (2 ± 2 s) during ventricular fibrillation (VF) induction and 4/54 shocks. Leadless pacemaker communication and pacing did not interfere with S-ICD rhythm discrimination. Additionally, all VF episodes (n = 12/12), including during simultaneous LP pacing, were detected and treated by the S-ICD. Post-shock LP performance was unaltered, and no post-shock device resets or dislodgements were observed (24 S-ICD and 30 external shocks). Human experience : The S-ICD/LP patient showed adequate S-ICD sensing during intrinsic rhythm, nominal, and high-output LP pacing. Two LP patients (without S-ICD) received ECV during follow-up. No impact on performance or LP dislodgements were observed. CONCLUSION: Combined LP and S-ICD therapy appears feasible in all animal experiments (n = 2) and in one human subject. No interference in sensing and pacing during intrinsic and paced rhythm was noted in both animal and human subjects. However, induced arrhythmia testing was not performed in the patient. Defibrillation therapy did not seem to affect LP function. More data on safety and performance are needed.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/normas , Cardioversão Elétrica/instrumentação , Marca-Passo Artificial/normas , Idoso , Idoso de 80 Anos ou mais , Animais , Terapia Combinada , Eletrocardiografia , Desenho de Equipamento , Seguimentos , Humanos , Masculino , Países Baixos , Ovinos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...