Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Arthroplast Today ; 28: 101464, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39100416

RESUMO

Background: Tibiofemoral components rotational congruency affects the total knee arthroplasty (TKA) success. The smart insert sensor (I-S) helps to establish tibial component rotation reciprocally to a fixed femoral rotation. We aimed (1) to validate the use of I-S as a possible tool to reach reproducible reciprocal femorotibial rotation (RftR) in TKA independently from anatomic landmarks, reducing outliers in combined and mismatched femorotibial rotation (CftR and MMftR, respectively) positioning and (2) to validate the "curve-on-curve" method for a specific type of asymmetrical tibial component. Methods: From February 2018, we conducted a prospective case-control study including 106 patients undergoing TKA. Patients were divided into 2 groups based on the method used to establish tibial component rotation: with the I-S use (group A, n = 53) and with the standard "curve-on-curve" technique (group B, n = 53). Rotational alignment was calculated using the Berger protocol with postoperative computed tomography scanning. Alignment parameters measured were tibial and femoral component rotations (tR, fR), the CftR, the MMftR, and the RftR. Results: Intraoperative rotation measured by I-S correlated the best with RftR (r = 0.84; P < .001) at the post-operative CT scanning. No significant differences were found between groups A and B regarding all types of rotation (fR: P = .774; tR: P = .467; CftR: P = .847) except for MMftR (P = .036) and RftR (P = .023). There were no outliers in group A but 27 and 12 outliers in group B for MMftR and CftR respectively (P < .001; P = .032). Conclusions: The TKA components' rotation established using a smart I-S intraoperatively is ascribable to the RftR at postoperative computed tomography scan. The I-S helps reduce outliers in the CftR and MMftR. An asymmetrical tibial base plate implanted using the curve-on-curve technique does not create a neutral reciprocal femorotibial rotation significantly increasing the number of cases with mismatched femorotibial internal rotation.

2.
Eur J Orthop Surg Traumatol ; 34(2): 1017-1024, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37855937

RESUMO

INTRODUCTION: The sustentaculum tali is displaced in almost half of calcaneal fractures and during surgical fixation represents one of the main reference points upon which the other bone has to be reduced. The purpose of this study was to investigate which subtalar joint fracture pattern is more frequently associated with sustentaculum tali involvement. Furthermore, correlation between postoperative clinical outcome and sustentaculum tali integrity was performed. MATERIAL AND METHODS: Patients with isolated calcaneal fractures were analyzed. Sanders-type fracture and involvement of both sustentaculum tali and calcaneocuboid joint were detected on computed tomography imaging; postoperative AOFAS scores were analyzed according to sustentacular involvement. RESULTS: Fifty calcaneus fractures in 47 patients were included in the final analysis. The sustentaculum tali was fractured in 18 cases (36.0%), thus contradicting its supposed constant position. Sanders type 3 and 4 fractures were more frequently associated with fractured sustentaculum than type 2 (p = 0.012). Sanders type 4 fractures were associated with displaced sustentacular fragment significantly more than type 2 and 3 (p = 0.043). Patients with intact sustentaculum tali reported significantly higher (p < 0.001) mean AOFAS scores than the uninjured group (84.4 ± 9.1 and 74.3 ± 9.5, respectively). CONCLUSION: Sanders type 3 and 4 fractures were more frequently associated with sustentaculum tali and/or calcaneocuboid joint involvement than simpler fractures. Injury of sustentaculum tali was related to significant worse postoperative clinical outcomes, underlying the relevance of this fragment on clinical course.


Assuntos
Traumatismos do Tornozelo , Calcâneo , Fraturas Ósseas , Humanos , Calcâneo/diagnóstico por imagem , Calcâneo/cirurgia , Calcâneo/lesões , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Parafusos Ósseos , Fraturas Ósseas/complicações , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , , Resultado do Tratamento
3.
J Knee Surg ; 35(14): 1549-1555, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33853154

RESUMO

Robotic-assisted medial unicompartmental knee arthroplasty (mUKA) has been introduced to improve accuracy in implant positioning and limb alignment, overcoming the reported high failure rates of conventional UKA. Indeed, mUKA is a technically challenging procedure strongly related to surgeons' skills and expertise. The purpose of this study was to evaluate the likelihood of robotic-assisted surgery in reducing the variability of coronal and sagittal component positioning between high- and low-volume surgeons. We evaluated a prospective cohort of 161 robotic mUKA implanted between May 2018 and December 2019 at two high-volume robotic centers. Patients were divided into two groups: patients operated by "high-volume" (group A) or "low-volume" (group B) surgeons. We recorded intraoperative lower-limb alignment, component positioning, and surgical timing. Postoperatively, every patient underwent a radiographical protocol to assess coronal and sagittal femoral/tibial component alignment. Range of motion and other clinical outcomes were assessed pre- and 12 months postoperatively by using oxford knee score, forgotten joint score, and visual analog scale. Of 161 recruited knees, 149 (A: 101; B: 48) were available for radiographic analysis at 1 month, and clinical evaluation at 12 months. No clinical difference neither difference in mechanical alignment nor coronal/sagittal component positioning were found (p > 0.05). A significant difference was recorded in surgical timing (A: 57 minutes; B: 86 minutes; p < 0.05). No superficial or deep infections or other major complications have been developed during the follow-up. Robotics surgery in mUKA confirmed its value in improving the reproducibility of such technical procedure, with satisfactory clinical outcomes. Moreover, it almost eliminates any possible differences in component positioning, and lower limb alignment among low-and high- volume knee surgeons.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Cirurgiões , Humanos , Artroplastia do Joelho/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia
4.
Phys Sportsmed ; 49(2): 171-175, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32669026

RESUMO

BACKGROUND: Anterior cruciate ligament reconstruction (ACLR) with cortical fixation adjustable-loop devices are associated with high potential risk of button malpositioning or interposition of the soft tissue between lateral femoral cortex and the button. Surgeons usually use X-rays to check and avoid button malposition and soft tissue interposition. Arthroscopic visualization of button position through the lateral gutter has been described. With this technique, it is possible for identification and correction of femoral button malalignment in the setting of soft tissue interposition and it could avoid the use of post-operative X-ray. METHODS: A total of 193 ACLR were included and patients were randomized into two groups. The first series (Group A) of 112 patients who sustained an ACLR with post-operative X-ray to assess the position of the femoral button and the second series (Group B) of 81 patients who sustained an ACLR with an arthroscopic exploration of the button followed by post-operative X-ray. RESULTS: On the post-operative radiographs, tissue interposition between the button and femoral cortex was found in nine cases of 112 in Group A (8%) and in zero case of 81 in Group B (0%). In six cases (7,4%) in Group B, there was a soft tissue interposition between the button and femoral cortex as visualized by arthroscopic confirmation and before post-operative X-ray; in all these cases, the soft tissue was removed, and the button was in contact with the bone in all X-ray made in the Group B. CONCLUSIONS: This technique allows for identification and correction of femoral button malalignment in the setting of soft tissue interposition and reduces the use of post-operative X-ray.


Assuntos
Reconstrução do Ligamento Cruzado Anterior , Articulação do Joelho , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Articulação do Joelho/cirurgia , Radiografia , Raios X
5.
Joints ; 7(3): 91-97, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34195536

RESUMO

Purrpose Metal-on-metal (MoM) total hip arthroplasty (THA) has been a subject of recent discussion and concern due to the early failures caused by local and systemic adverse reactions related to specific designs. The aim of this study is to analyze the outcomes and survival rates of a single brand of MoM implants implanted in a consecutive series of patients at a single institution. Methods Between 2007 and 2012, 116 (118 hips) patients were evaluated at a mean follow-up of 6.6 years after primary THA. The diagnosis leading to surgery was osteoarthritis (80 patients) and proximal femoral fracture (36 patients). A single design of THA was implanted. All patients were evaluated before surgery and postoperatively at 1, 3, 6, and 12 months by clinical scores and radiographic studies. The data analysis was made using Student's t -test. Results The minimum follow-up was of 4 years, with a mean follow-up of 6.6 years. Two aseptic loosenings of the acetabular component were recorded (one per group), which were not associated with local or systemic complications related to metal ion release. Both were revised by an isolated acetabular cup substitution with metal-on-polyethylene couplings. Nonprogressive radiolucency lines < 2 mm in zone 2 were observed in other six patients around the acetabular component without clinical manifestation (four in the arthritis group and two in the fracture group). Postoperative Harris Hip Score and SF-36 (36-Item Short Form Survey) score improved in both groups. Conclusion Despite several MoM implants showing early complications and failures, a specific MoM design may be associated with good clinical results at a mid- to long-term follow-up. Level of Evidence This is a therapeutic case series, Level 4 study.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA