Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ultrason Sonochem ; 101: 106649, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37866136

RESUMO

Holmium:yttrium-aluminum-garnet (Ho:YAG) laser lithotripsy (LL) has been the treatment of choice for kidney stone disease for more than two decades, yet the mechanisms of action are not completely clear. Besides photothermal ablation, recent evidence suggests that cavitation bubble collapse is pivotal in kidney stone dusting when the Ho:YAG laser operates at low pulse energy (Ep) and high frequency (F). In this work, we perform a comprehensive series of experiments and model-based simulations to dissect the complex physical processes in LL. Under clinically relevant dusting settings (Ep = 0.2 J, F = 20 Hz), our results suggest that majority of the irradiated laser energy (>90 %) is dissipated by heat generation in the fluid surrounding the fiber tip and the irradiated stone surface, while only about 1 % may be consumed for photothermal ablation, and less than 0.7 % is converted into the potential energy at the maximum bubble expansion. We reveal that photothermal ablation is confined locally to the laser irradiation spot, whereas cavitation erosion is most pronounced at a fiber tip-stone surface distance about 0.5 mm where multi foci ring-like damage outside the thermal ablation zone is observed. The cavitation erosion is caused by the progressively intensified collapse of jet-induced toroidal bubble near the stone surface (<100 µm), as a result of Raleigh-Taylor and Richtmyer-Meshkov instabilities. The ensuing shock wave-stone interaction and resultant leaky Rayleigh waves on the stone surface may lead to dynamic fatigue and superficial material removal under repeated bombardments of toroidal bubble collapses during dusting procedures in LL.


Assuntos
Cálculos Renais , Lasers de Estado Sólido , Litotripsia a Laser , Humanos , Litotripsia a Laser/métodos , Hólmio , Lasers de Estado Sólido/uso terapêutico , Cálculos Renais/terapia
2.
Phys Fluids (1994) ; 35(3): 033303, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36896246

RESUMO

Recent studies indicate that cavitation may play a vital role in laser lithotripsy. However, the underlying bubble dynamics and associated damage mechanisms are largely unknown. In this study, we use ultra-high-speed shadowgraph imaging, hydrophone measurements, three-dimensional passive cavitation mapping (3D-PCM), and phantom test to investigate the transient dynamics of vapor bubbles induced by a holmium:yttrium aluminum garnet laser and their correlation with solid damage. We vary the standoff distance (SD) between the fiber tip and solid boundary under parallel fiber alignment and observe several distinctive features in bubble dynamics. First, long pulsed laser irradiation and solid boundary interaction create an elongated "pear-shaped" bubble that collapses asymmetrically and forms multiple jets in sequence. Second, unlike nanosecond laser-induced cavitation bubbles, jet impact on solid boundary generates negligible pressure transients and causes no direct damage. A non-circular toroidal bubble forms, particularly following the primary and secondary bubble collapses at SD = 1.0 and 3.0 mm, respectively. We observe three intensified bubble collapses with strong shock wave emissions: the intensified bubble collapse by shock wave, the ensuing reflected shock wave from the solid boundary, and self-intensified collapse of an inverted "triangle-shaped" or "horseshoe-shaped" bubble. Third, high-speed shadowgraph imaging and 3D-PCM confirm that the shock origins from the distinctive bubble collapse form either two discrete spots or a "smiling-face" shape. The spatial collapse pattern is consistent with the similar BegoStone surface damage, suggesting that the shockwave emissions during the intensified asymmetric collapse of the pear-shaped bubble are decisive for the solid damage.

3.
J Endourol ; 36(5): 674-683, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34806899

RESUMO

Objective: To investigate the mechanism of stone dusting in Holmium (Ho): YAG laser lithotripsy (LL). Materials and Methods: Cylindrical BegoStone samples (6 × 6 mm, H × D) were treated in water using a clinical Ho:YAG laser lithotripter in dusting mode (0.2-0.4 J with 70-78 µs in pulse duration, 20 Hz) at various fiber tip to stone standoff distances (SD = 0, 0.5, and 1 mm). Stone damage craters were quantified by optical coherence tomography and bubble dynamics were captured by high-speed video imaging. To differentiate the contribution of cavitation vs thermal ablation to stone damage, three additional experiments were performed. First, presoaked wet stones were treated in air to assess stone damage without cavitation. Second, the laser fiber was advanced at various offset distances (OSD = 0.25, 1, 2, 3, and 10 mm) from the tip of a flexible ureteroscope to alter the dynamics of bubble collapse. Third, stones were treated with parallel fiber to minimize photothermal damage while isolating the contribution of cavitation to stone damage. Results: Treatment in water resulted in 2.5- to 90-fold increase in stone damage compared with those produced in air where thermal ablation dominates. With the fiber tip placed at OSD = 0.25 mm, the collapse of the bubble was distracted away from the stone surface by the ureteroscope tip, leading to significantly reduced stone damage compared with treatment without the scope or with scope at large OSD of 3-10 mm. The average crater volume produced by parallel fiber orientation at 0.2 J after 100 pulses, where cavitation is the dominant mechanism of stone damage, was comparable with those produced by using perpendicular fiber orientation within SD = 0.25-1 mm. Conclusion: Cavitation plays a dominant role over photothermal ablation in stone dusting during short pulse Ho:YAG LL when 10 or more pulses are delivered to the same location.


Assuntos
Cálculos , Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Hólmio , Humanos , Lasers de Estado Sólido/uso terapêutico , Litotripsia a Laser/métodos , Água
4.
J Acoust Soc Am ; 150(2): 1013, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34470261

RESUMO

During clinical procedures, the lithotripter shock wave (LSW) that is incident on the stone and resultant stress field is often asymmetric due to the respiratory motion of the patient. The variations of the LSW-stone interaction and associated fracture pattern were investigated by photoelastic imaging, phantom experiments, and three-dimensional fluid-solid interaction modeling at different lateral locations in a lithotripter field. In contrast to a T-shaped fracture pattern often observed in the posterior region of the disk-shaped stone under symmetric loading, the fracture pattern gradually transitioned to a tilted L-shape under asymmetric loading conditions. Moreover, the model simulations revealed the generation of surface acoustic waves (SAWs), i.e., a leaky Rayleigh wave on the anterior boundary and Scholte wave on the posterior boundary of the stone. The propagation of SAWs on the stone boundary is accompanied by a progressive transition of the LSW reflection pattern from regular to von Neumann and to weak von Neumann reflection near the glancing incidence and, concomitantly, the development and growth of a Mach stem, swirling around the stone boundary. The maximum tensile stress and stress integral were produced by SAWs on the stone boundary under asymmetric loading conditions, which drove the initiation and extension of surface cracks into the bulk of the stone that is confirmed by micro-computed tomography analysis.


Assuntos
Cálculos Renais , Litotripsia , Humanos , Cálculos Renais/terapia , Litotripsia/efeitos adversos , Imagens de Fantasmas , Som , Microtomografia por Raio-X
5.
Artigo em Inglês | MEDLINE | ID: mdl-33635787

RESUMO

Passive cavitation mapping (PCM), which generates images using bubble acoustic emission signals, has been increasingly used for monitoring and guiding focused ultrasound surgery (FUS). PCM can be used as an adjunct to magnetic resonance imaging to provide crucial information on the safety and efficacy of FUS. The most widely used algorithm for PCM is delay-and-sum (DAS). One of the major limitations of DAS is its suboptimal computational efficiency. Although frequency-domain DAS can partially resolve this issue, such an algorithm is not suitable for imaging the evolution of bubble activity in real time and for cases in which cavitation events occur asynchronously. This study investigates a transient angular spectrum (AS) approach for PCM. The working principle of this approach is to backpropagate the received signal to the domain of interest and reconstruct the spatial-temporal wavefield encoded with the bubble location and collapse time. The transient AS approach is validated using an in silico model and water bath experiments. It is found that the transient AS approach yields similar results to DAS, but it is one order of magnitude faster. The results obtained by this study suggest that the transient AS approach is promising for fast and accurate PCM.


Assuntos
Acústica , Algoritmos , Imageamento por Ressonância Magnética
6.
J Acoust Soc Am ; 149(2): 1258, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33639826

RESUMO

Shock wave lithotripsy (SWL) has been widely used for non-invasive treatment of kidney stones. Cavitation plays an important role in stone fragmentation, yet it may also contribute to renal injury during SWL. It is therefore crucial to determine the spatiotemporal distributions of cavitation activities to maximize stone fragmentation while minimizing tissue injury. Traditional cavitation detection methods include high-speed optical imaging, active cavitation mapping (ACM), and passive cavitation mapping (PCM). While each of the three methods provides unique information about the dynamics of the bubbles, PCM has most practical applications in biological tissues. To image the dynamics of cavitation bubble collapse, we previously developed a sliding-window PCM (SW-PCM) method to identify each bubble collapse with high temporal and spatial resolution. In this work, to further validate and optimize the SW-PCM method, we have developed tri-modality cavitation imaging that includes three-dimensional high-speed optical imaging, ACM, and PCM seamlessly integrated in a single system. Using the tri-modality system, we imaged and analyzed laser-induced single cavitation bubbles in both free field and constricted space and shock wave-induced cavitation clusters. Collectively, our results have demonstrated the high reliability and spatial-temporal accuracy of the SW-PCM approach, which paves the way for the future in vivo applications on large animals and humans in SWL.


Assuntos
Cálculos Renais , Litotripsia , Animais , Humanos , Cálculos Renais/terapia , Reprodutibilidade dos Testes
7.
J Endourol ; 35(6): 860-870, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33514285

RESUMO

Purpose: Although cavitation during laser lithotripsy (LL) contributes to the Moses effect, the impact of cavitation on stone damage is less clear. Using different laser settings, we investigate the role of cavitation bubbles in energy delivery and stone damage. Materials and Methods: The role of cavitation in laser energy delivery was characterized by using photodetector measurements synced with high-speed imaging for laser pulses of varying durations. BegoStone samples were treated with the laser fiber oriented perpendicularly in contact with the stone in water or in air to assess the impact of cavitation on crater formation. Crater volume and geometry were quantified by using optical coherence tomography. Further, the role of cavitation in stone damage was elucidated by treatment in water with the fiber oriented parallel to the stone surface and by photoelastic imaging. Results: Longer pulse durations resulted in higher energy delivery but smaller craters. Stones treated in water resulted in greater volume, wider yet shallower craters compared with those treated in air. Stones treated with the parallel fiber showed crater formation after 15 pulses, confirmed by high-speed imaging of the bubble collapse with the resultant stress field captured by photoelastic imaging. Conclusions: Despite improved energy delivery, the longer pulse mode produced smaller crater volume, suggesting additional processes secondary to photothermal ablation are involved in stone damage. Our critical observations of the difference in stone damage treated in water vs in air, combined with the crater formation by parallel fiber, suggest that cavitation is a contributor to stone damage during LL.


Assuntos
Cálculos Renais , Litotripsia a Laser , Litotripsia , Humanos , Cálculos Renais/cirurgia , Litotripsia/efeitos adversos , Litotripsia a Laser/efeitos adversos
8.
IEEE Trans Med Imaging ; 40(1): 346-356, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32986546

RESUMO

The penetration depth of photoacoustic imaging in biological tissues has been fundamentally limited by the strong optical attenuation when light is delivered externally through the tissue surface. To address this issue, we previously reported internal-illumination photoacoustic imaging using a customized radial-emission optical fiber diffuser, which, however, has complex fabrication, high cost, and non-uniform light emission. To overcome these shortcomings, we have developed a new type of low-cost fiber diffusers based on a graded-scattering method in which the optical scattering of the fiber diffuser is gradually increased as the light travels. The graded scattering can compensate for the optical attenuation and provide relatively uniform light emission along the diffuser. We performed Monte Carlo numerical simulations to optimize several key design parameters, including the number of scattering segments, scattering anisotropy factor, divergence angle of the optical fiber, and reflective index of the surrounding medium. These optimized parameters collectively result in uniform light emission along the fiber diffuser and can be flexibly adjusted to accommodate different applications. We fabricated and characterized the prototype fiber diffuser made of agarose gel and intralipid. Equipped with the new fiber diffuser, we performed thorough proof-of-concept studies on ex vivo tissue phantoms and an in vivo swine model to demonstrate the deep-imaging capability (~10 cm achieved ex vivo) of photoacoustic tomography. We believe that the internal light delivery via the optimized fiber diffuser is an effective strategy to image deep targets (e.g., kidney) in large animals or humans.


Assuntos
Iluminação , Fotoquimioterapia , Animais , Método de Monte Carlo , Imagens de Fantasmas , Suínos , Tomografia Computadorizada por Raios X
9.
Optica ; 6(2): 198-205, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31286029

RESUMO

Temperature mapping is essential in many biomedical studies and interventions to precisely control the tissue's thermal conditions for optimal treatment efficiency and minimal side effects. Based on the Grüneisen parameter's temperature dependence, photoacoustic (PA) imaging can provide relative temperature measurement, but it has been traditionally challenging to measure absolute temperatures without knowing the baseline temperature, especially in deep tissues with unknown optical and acoustic properties. Here, we report a new thermal-energy-memory-based photoacoustic thermometry (TEMPT). By illuminating the tissue with a burst of nanosecond laser pulses, TEMPT exploits the temperature dependence of the thermal energy lingering, which is probed by the corresponding PA signals acquired within the thermal confinement. A self-normalized ratiometric measurement cancels out temperature-irrelevant quantities and estimates the Grüneisen parameter. The temperature can then be evaluated, given the tissue's temperature-dependent Grüneisen parameter, mass density, and specific heat capacity. Unlike the conventional PA thermometry, TEMPT does not require the knowledge of tissue's baseline temperature, nor the optical properties. We have developed a mathematical model to describe the temperature dependence in TEMPT. We have demonstrated the feasibility of the temperature evaluation on tissue phantoms at 1.5 cm depth within a clinically relevant temperature range. Finally, as proof-of-concept, we applied TEMPT for temperature mapping during focused ultrasound treatment in mice in vivo at 2 mm depth. As a generic temperature mapping method, TEMPT is expected to find applications in thermotherapy of cancers on small animal models.

10.
Int J Fract ; 211(1-2): 203-216, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-30349151

RESUMO

A damage model suggested by the Tuler-Butcher concept of dynamic accumulation of microscopic defects is obtained from experimental data on microcrack formation in synthetic kidney stones. Experimental data on appearance of microcracks is extracted from micro-computed tomography images of BegoStone simulants obtained after subjecting the stone to successive pulses produced by an electromagnetic shock-wave lithotripter source. Image processing of the data is used to infer statistical distributions of crack length and width in representative transversal cross-sections of a cylindrical stone. A high-resolution finite volume computational model, capable of accurately modeling internal reflections due to local changes in material properties produced by material damage is used to simulate the accumulation of damage due to successive shocks. Comparison of statistical distributions of microcrack formation in computation and experiment allows calibration of the damage model. The model is subsequently used to compute fracture of a different aspect-ratio cylindrical stone predicting concurrent formation of two main fracture areas as observed experimentally.

11.
J Endourol ; 31(5): 502-509, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28340536

RESUMO

OBJECTIVE: To investigate the impact of lithotripter focal width on stone fragmentation. MATERIALS AND METHODS: A modified reflector was used to reduce -6 dB beam size of the HM3 lithotripter, while increasing concomitantly peak pressure. Fragmentation in vitro was assessed with modified and original reflectors using BegoStone phantoms. A membrane holder was used to mimic lithotripsy in vivo, and a matrix holder was used to assess variations of fragmentation power in the focal plane of the lithotripter field. Stone fragmentation in vivo produced by the two reflectors was further compared in a swine model. RESULTS: Stone fragmentation in vitro after 500 (or 2000) shocks was ∼60% (or ∼82%) vs ∼40% (or ∼75%) with original and modified reflector, respectively (p ≤ 0.0016). Fragmentation power with the modified reflector was the highest on the lithotripter axis, but dropped rapidly in the lateral direction and became insignificant at radial distances >6.0 mm. Stone fragmentation with the original reflector was lower along the lithotripter axis, but fragmentation power decayed slowly in lateral direction, with appreciable fragmentation produced at 6.0 mm. Stone fragmentation efficiency in vivo after 500 (or 2000) shocks was ∼70% (or ∼90%) vs ∼45% (or ∼80%) with original and modified reflector, respectively (p ≤ 0.04). CONCLUSIONS: A lithotripter field with broad beam size yields superior stone comminution when compared with narrow beam size under comparable effective acoustic pulse energy both in vivo and in vitro. These findings may facilitate future improvements in lithotripter design to maximize comminution efficiency while minimizing tissue injury.


Assuntos
Cálculos Renais/cirurgia , Litotripsia/métodos , Acústica , Animais , Pesquisa Comparativa da Efetividade , Modelos Animais de Doenças , Feminino , Humanos , Imagens de Fantasmas , Pressão , Suínos
12.
J Vis Exp ; (119)2017 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-28117807

RESUMO

In this manuscript, we first describe the fabrication protocol of a microfluidic chip, with gold dots and fibronectin-coated regions on the same glass substrate, that precisely controls the generation of tandem bubbles and individual cells patterned nearby with well-defined locations and shapes. We then demonstrate the generation of tandem bubbles by using two pulsed lasers illuminating a pair of gold dots with a few-microsecond time delay. We visualize the bubble-bubble interaction and jet formation by high-speed imaging and characterize the resultant flow field using particle image velocimetry (PIV). Finally, we present some applications of this technique for single cell analysis, including cell membrane poration with macromolecule uptake, localized membrane deformation determined by the displacements of attached integrin-binding beads, and intracellular calcium response from ratiometric imaging. Our results show that a fast and directional jetting flow is produced by the tandem bubble interaction, which can impose a highly localized shear stress on the surface of a cell grown in close proximity. Furthermore, different bioeffects can be induced by altering the strength of the jetting flow by adjusting the standoff distance from the cell to the tandem bubbles.


Assuntos
Comunicação Celular , Membrana Celular/fisiologia , Microfluídica/métodos , Análise de Célula Única , Células HeLa , Humanos , Lasers , Reologia
13.
J Endourol ; 30(11): 1150-1154, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27736195

RESUMO

INTRODUCTION: The Nanopulse Lithotripter (NPL; Lithotech Medical, Israel) is a novel intracorporeal device that uses a nanosecond duration electrical discharge through a reusable flexible coaxial probe to endoscopically fragment urinary stones. This device was compared with a holmium laser lithotripsy (HoL) with regard to stone fragmentation efficiency (SFE) and its impact on flexible ureteroscope (URS) deflection and flow of irrigation. METHODS: Using a custom bench model, a 6 mm BegoStone cylindrical phantom (mixture 5:2) was confined under 0.9% saline atop sequential mesh sieves. The SFE of two NPL probe sizes (2.0F, 3.6F) and two HoL fibers (200, 365 µm) was evaluated using concordant settings of 1 J and 5 Hz. URS deflection and irrigation flow with NPL probes in the working channel were tested in five new fourth generation flexible URS and compared with other adjunct endourologic instruments. RESULTS: The 2.0F NPL showed improved SFE compared with the 200 µm laser (86 mg/min vs 52 mg/min, p = 0.014) as did the 3.6F NPL vs the 365 µm laser (173 mg/min vs 80 mg/min, p = 0.05). The NPL created more 1 to 2 mm fragments; the laser created more dust. URS deflection reduced by 3.75° with the 2.0 NPL probe. URS irrigation flow reduced from 36.5 to 6.3 mL/min with the 2.0F NPL probe. CONCLUSION: NPL shows improved SFE compared with HoL. Flow with the 2.0F probe is akin to a stone basket. NPL offers an effective alternative to HoL.


Assuntos
Lasers de Estado Sólido/uso terapêutico , Litotripsia a Laser/instrumentação , Cálculos Urinários/terapia , Endoscopia/métodos , Desenho de Equipamento , Hólmio , Humanos , Litotripsia a Laser/métodos , Imagens de Fantasmas , Ureteroscópios , Ureteroscopia/métodos , Urolitíase/terapia
14.
Proc Natl Acad Sci U S A ; 111(13): E1167-75, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24639497

RESUMO

The efficiency of shock wave lithotripsy (SWL), a noninvasive first-line therapy for millions of nephrolithiasis patients, has not improved substantially in the past two decades, especially in regard to stone clearance. Here, we report a new acoustic lens design for a contemporary electromagnetic (EM) shock wave lithotripter, based on recently acquired knowledge of the key lithotripter field characteristics that correlate with efficient and safe SWL. The new lens design addresses concomitantly three fundamental drawbacks in EM lithotripters, namely, narrow focal width, nonidealized pulse profile, and significant misalignment in acoustic focus and cavitation activities with the target stone at high output settings. Key design features and performance of the new lens were evaluated using model calculations and experimental measurements against the original lens under comparable acoustic pulse energy (E+) of 40 mJ. The -6-dB focal width of the new lens was enhanced from 7.4 to 11 mm at this energy level, and peak pressure (41 MPa) and maximum cavitation activity were both realigned to be within 5 mm of the lithotripter focus. Stone comminution produced by the new lens was either statistically improved or similar to that of the original lens under various in vitro test conditions and was significantly improved in vivo in a swine model (89% vs. 54%, P = 0.01), and tissue injury was minimal using a clinical treatment protocol. The general principle and associated techniques described in this work can be applied to design improvement of all EM lithotripters.


Assuntos
Fenômenos Eletromagnéticos , Lentes , Litotripsia/instrumentação , Animais , Desenho de Equipamento , Feminino , Movimento (Física) , Respiração , Pele/patologia , Sus scrofa
15.
J Acoust Soc Am ; 134(2): 1598-609, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23927200

RESUMO

A multiphysics computational model of the focusing of an acoustic pulse and subsequent shock wave formation that occurs during extracorporeal shock wave lithotripsy is presented. In the electromagnetic lithotripter modeled in this work the focusing is achieved via a polystyrene acoustic lens. The transition of the acoustic pulse through the solid lens is modeled by the linear elasticity equations and the subsequent shock wave formation in water is modeled by the Euler equations with a Tait equation of state. Both sets of equations are solved simultaneously in subsets of a single computational domain within the BEARCLAW framework which uses a finite-volume Riemann solver approach. This model is first validated against experimental measurements with a standard (or original) lens design. The model is then used to successfully predict the effects of a lens modification in the form of an annular ring cut. A second model which includes a kidney stone simulant in the domain is also presented. Within the stone the linear elasticity equations incorporate a simple damage model.


Assuntos
Simulação por Computador , Fenômenos Eletromagnéticos , Ondas de Choque de Alta Energia , Modelos Lineares , Litotripsia/métodos , Elasticidade , Desenho de Equipamento , Cálculos Renais/química , Cálculos Renais/cirurgia , Litotripsia/instrumentação , Movimento (Física) , Análise Numérica Assistida por Computador , Poliestirenos , Pressão , Reprodutibilidade dos Testes , Som , Fatores de Tempo
16.
J Urol ; 190(3): 1096-101, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23485509

RESUMO

PURPOSE: The acoustic lens of the Modularis electromagnetic shock wave lithotripter (Siemens, Malvern, Pennsylvania) was modified to produce a pressure waveform and focal zone more closely resembling that of the original HM3 device (Dornier Medtech, Wessling, Germany). We assessed the newly designed acoustic lens in vivo in an animal model. MATERIALS AND METHODS: Stone fragmentation and tissue injury produced by the original and modified lenses of the Modularis lithotripter were evaluated in a swine model under equivalent acoustic pulse energy (about 45 mJ) at 1 Hz pulse repetition frequency. Stone fragmentation was determined by the weight percent of stone fragments less than 2 mm. To assess tissue injury, shock wave treated kidneys were perfused, dehydrated, cast in paraffin wax and sectioned. Digital images were captured every 120 µm and processed to determine functional renal volume damage. RESULTS: After 500 shocks, the mean ± SD stone fragmentation efficiency produced by the original and modified lenses was 48% ± 12% and 52% ± 17%, respectively (p = 0.60). However, after 2,000 shocks, the modified lens showed significantly improved stone fragmentation compared to the original lens (mean 86% ± 10% vs 72% ± 12%, p = 0.02). Tissue injury caused by the original and modified lenses was minimal at a mean of 0.57% ± 0.44% and 0.25% ± 0.25%, respectively (p = 0.27). CONCLUSIONS: With lens modification the Modularis lithotripter demonstrates significantly improved stone fragmentation with minimal tissue injury at a clinically relevant acoustic pulse energy. This new lens design could potentially be retrofitted to existing lithotripters, improving the effectiveness of electromagnetic lithotripters.


Assuntos
Cálculos Renais/terapia , Litotripsia/instrumentação , Microscopia Acústica/instrumentação , Animais , Modelos Animais de Doenças , Campos Eletromagnéticos , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Litotripsia/métodos , Microscopia Acústica/métodos , Sensibilidade e Especificidade , Sus scrofa , Suínos
17.
Phys Med Biol ; 58(3): 735-48, 2013 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-23322027

RESUMO

Previous studies have demonstrated that stone comminution decreases with increased pulse repetition frequency as a result of bubble proliferation in the cavitation field of a shock wave lithotripter (Pishchalnikov et al 2011 J. Acoust. Soc. Am. 130 EL87-93). If cavitation nuclei remain in the propagation path of successive lithotripter pulses, especially in the acoustic coupling cushion of the shock wave source, they will consume part of the incident wave energy, leading to reduced tensile pressure in the focal region and thus lower stone comminution efficiency. We introduce a method to remove cavitation nuclei from the coupling cushion between successive shock exposures using a jet of degassed water. As a result, pre-focal bubble nuclei lifetime quantified by B-mode ultrasound imaging was reduced from 7 to 0.3 s by a jet with an exit velocity of 62 cm s(-1). Stone fragmentation (percent mass <2 mm) after 250 shocks delivered at 1 Hz was enhanced from 22 ± 6% to 33 ± 5% (p = 0.007) in water without interposing tissue mimicking materials. Stone fragmentation after 500 shocks delivered at 2 Hz was increased from 18 ± 6% to 28 ± 8% (p = 0.04) with an interposing tissue phantom of 8 cm thick. These results demonstrate the critical influence of cavitation bubbles in the coupling cushion on stone comminution and suggest a potential strategy to improve the efficacy of contemporary shock wave lithotripters.


Assuntos
Fenômenos Eletromagnéticos , Litotripsia/métodos , Água , Acústica , Humanos , Hidrodinâmica , Litotripsia/instrumentação , Imagens de Fantasmas
18.
Rev Sci Instrum ; 83(4): 043701, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22559533

RESUMO

An experimental system for digital stereoscopic imaging produced by using a high-speed color camera is described. Two bright-field image projections of a three-dimensional object are captured utilizing additive-color backlighting (blue and red). The two images are simultaneously combined on a two-dimensional image sensor using a set of dichromatic mirrors, and stored for off-line separation of each projection. This method has been demonstrated in analyzing cavitation bubble dynamics near boundaries. This technique may be useful for flow visualization and in machine vision applications.


Assuntos
Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Cor , Hidrodinâmica
19.
J Acoust Soc Am ; 130(5): 3339-46, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22088007

RESUMO

The dynamics of tandem bubble interaction in a microfluidic channel (800 × 21 µm, W × H) have been investigated using high-speed photography, with resultant fluid motion characterized by particle imaging velocimetry. A single or tandem bubble is produced reliably via laser absorption by micron-sized gold dots (6 µm in diameter with 40 µm in separation distance) coated on a glass surface of the microfluidic channel. Using two pulsed Nd:YAG lasers at λ = 1064 nm and ∼10 µJ/pulse, the dynamics of tandem bubble interaction (individual maximum bubble diameter of 50 µm with a corresponding collapse time of 5.7 µs) are examined at different phase delays. In close proximity (i.e., interbubble distance = 40 µm or γ = 0.8), the tandem bubbles interact strongly with each other, leading to asymmetric deformation of the bubble walls and jet formation, as well as the production of two pairs of vortices in the surrounding fluid rotating in opposite directions. The direction and speed of the jet (up to 95 m/s), as well as the orientation and strength of the vortices can be varied by adjusting the phase delay.


Assuntos
Ouro , Técnicas Analíticas Microfluídicas/instrumentação , Microfluídica/instrumentação , Pontos Quânticos , Absorção , Desenho de Equipamento , Gases , Lasers de Estado Sólido , Modelos Teóricos , Movimento (Física) , Oscilometria , Fotografação , Reologia , Fatores de Tempo
20.
J Endourol ; 25(9): 1507-11, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21834658

RESUMO

BACKGROUND AND PURPOSE: Previous studies have demonstrated that treatment strategy plays a critical role in ensuring maximum stone fragmentation during shockwave lithotripsy (SWL). We aimed to develop an optimal treatment strategy in SWL to produce maximum stone fragmentation. MATERIALS AND METHODS: Four treatment strategies were evaluated using an in-vitro experimental setup that mimics stone fragmentation in the renal pelvis. Spherical stone phantoms were exposed to 2100 shocks using the Siemens Modularis (electromagnetic) lithotripter. The treatment strategies included increasing output voltage with 100 shocks at 12.3 kV, 400 shocks at 14.8 kV, and 1600 shocks at 15.8 kV, and decreasing output voltage with 1600 shocks at 15.8 kV, 400 shocks at 14.8 kV, and 100 shocks at 12.3 kV. Both increasing and decreasing voltages models were run at a pulse repetition frequency (PRF) of 1 and 2 Hz. Fragmentation efficiency was determined using a sequential sieving method to isolate fragments less than 2 mm. A fiberoptic probe hydrophone was used to characterize the pressure waveforms at different output voltage and frequency settings. In addition, a high-speed camera was used to assess cavitation activity in the lithotripter field that was produced by different treatment strategies. RESULTS: The increasing output voltage strategy at 1 Hz PRF produced the best stone fragmentation efficiency. This result was significantly better than the decreasing voltage strategy at 1 Hz PFR (85.8% vs 80.8%, P=0.017) and over the same strategy at 2 Hz PRF (85.8% vs 79.59%, P=0.0078). CONCLUSIONS: A pretreatment dose of 100 low-voltage output shockwaves (SWs) at 60 SWs/min before increasing to a higher voltage output produces the best overall stone fragmentation in vitro. These findings could lead to increased fragmentation efficiency in vivo and higher success rates clinically.


Assuntos
Cálculos Renais/cirurgia , Litotripsia/métodos , Humanos , Imagens de Fantasmas , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA