Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Water Res ; 221: 118755, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-35728492

RESUMO

Pervious pavement system (PPS) is a suitable alternative technique for mitigating urban flooding and urban heat island (UHI) simultaneously. However, existing literature has revealed that PPSs cannot achieve the expected permeability and evaporation. To overcome this gap, this study presents an elaborate review of problems associated with PPSs and highlights its benefits to stormwater management and UHI mitigation. We determined key parameters of PPSs that could influence urban flooding and UHI mitigation, including hydrological properties, thermal physical properties, structure design, and clogging resistance. We identified the co-benefits approach of PPS towards performance synergism on stormwater management and UHI mitigation from quality controlled design and fabrication, periodic maintenance, and effective evaluation system based on practice environments. The results indicate that existing studies of PPSs primarily focus on permeability, while little emphasis is given to the evaporative cooling performance, leading to a biased development with a loss of test standards and regulations that cannot control the cooling potential of the system. The performance synergism of permeability and evaporative cooling in PPS should be studied further, while considering quality control of the materials and in-situ practice design. Parameter controls (with commonly used standards) during fabrication, periodic maintenance (during operation), and pre- and post-evaluation processes of PPSs should work collectively to achieve optimal benefits and reduced costs.


Assuntos
Temperatura Alta , Chuva , Cidades
2.
Sci Rep ; 11(1): 14725, 2021 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-34282243

RESUMO

Photoluminescent materials are advanced cutting-edge heat-rejecting materials capable of reemitting a part of the absorbed light through radiative/non-thermal recombination of excited electrons to their ground energy state. Photoluminescent materials have recently been developed and tested as advanced non-white heat-rejecting materials for urban heat mitigation application. Photoluminescent materials has shown promising cooling potential for urban heat mitigation application, but further developments should be made to achieve optimal photoluminescence cooling potential. In this paper, an advanced mathematical model is developed to explore the most efficient methods to enhance the photoluminescence cooling potential through estimation of contribution of non-radiative mechanisms. The non-radiative recombination mechanisms include: (1) Transmission loss and (2) Thermal losses including thermalization, quenching, and Stokes shift. The results on transmission and thermal loss mechanisms could be used for systems solely relying on photoluminescence cooling, while the thermal loss estimations can be helpful to minimize the non-radiative losses of both integrated photoluminescent-near infrared (NIR) reflective and stand-alone photoluminescent systems. As per our results, the transmission loss is higher than thermal loss in photoluminescent materials with an absorption edge wavelength (λAE) shorter than 794 nm and quantum yield (QY) of 50%. Our predictions show that thermalization loss overtakes quenching in photoluminescent materials with λAE longer than 834 nm and QY of 50%. The results also show that thermalization, quenching, and Stokes shift constitute around 56.8%, 35%, and 8.2% of the overall thermal loss. Results of this research can be used as a guide for the future research to enhance the photoluminescence cooling potential for urban heat mitigation application.

3.
iScience ; 24(5): 102495, 2021 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-34113830

RESUMO

A primary contributor to urban overheating is the urban heat island (UHI) formed due to increased urbanization. The adverse effects of UHI on building energy use are substantial and well documented. However, such effects are typically demonstrated through numerical simulations which are susceptible to modeling uncertainties and lack of validation resulting in a pressing research gap. Here, for the first time, we conduct a large-scale assessment to demonstrate the devastating impact of UHI on building energy consumption using real building energy use data. We find empirical evidence correlating UHI with building energy use; changes in average UHI intensity of 0.5 K correspond to an increase in monthly cooling energy consumption in a range of 0.17 kWh/m2-1.84 kWh/m2. The study validates theoretical evidence on the impact of UHI on building energy and proposes a highly innovative methodology to assess the impact of overheating on the energy balance of cities.

4.
Sci Total Environ ; 788: 147783, 2021 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-34029820

RESUMO

Associated with rapid urbanization and escalation of bushfire events, Sydney has experienced significant air quality degradation in the XXI century. In this study, we present a 15-year retrospective analysis on the influence of individual meteorological factors on major air pollutants (NO2, O3, PM10 and PM2.5) at 14 different sites in Greater Sydney and Illawarra. By applying a newly developed "zooming in" approach to long-term ground-based data, we disclose general, seasonal, daily and hourly patterns while increasing the level of spatial associativity. We provide evidence on the pivotal role played by urbanization, sprawling dynamics, global warming and bushfires on local meteorology and air pollution. We strike associations between temperature and O3, both as average trends and extremes, on account of increasing heat island effects. The role of wind in a coastal-basin environment, influenced by a vast desert biome inland, is investigated. A steady trend towards stagnation is outlined, boosted by enhanced urban roughness and intensified heat island circulation. Relative humidity is also crucial in the modulation between NO2 and O3. With a sharp tendency towards drier and hotter microclimates, NO2 levels dropped by approximately 50% over the years at all locations, while O3's median levels almost doubled in the last 10 years. Further, O3 and PMs shifted towards more frequent extreme events, strongly associated with the exacerbation of bushfire events. Such results suggest an urgent need to prioritize emission control, building air tightness improvement and urban heat mitigation, towards a future-proof governance in Sydney and similar regions in the world.

5.
Sci Rep ; 11(1): 6762, 2021 03 24.
Artigo em Inglês | MEDLINE | ID: mdl-33762659

RESUMO

Urban overheating (UO) may interact with synoptic-scale weather conditions. The association between meteorological parameters and UO has already been a subject of considerable research, however, the impact of synoptic-scale weather conditions on UO magnitude, particularly in a coastal city that is also near the desert landmass (Sydney) has never been investigated before. The present research examines the influence of synoptic-scale weather conditions on UO magnitude in Sydney by utilizing the newly developed gridded weather typing classification (GWTC). The diurnal, and seasonal variations in suburban-urban temperature contrast (ΔT) in association with synoptic-scale weather conditions, and ΔT response to synoptic air-masses during extreme heat events are investigated in three zones of Sydney. Generally, an exacerbation in UO magnitude was reported at daytime over the years, whereas the nocturnal UO magnitude was alleviated over time. The humid warm (HW), and warm (W) air-masses were found primarily responsible for exacerbated daytime UO during extreme heat events and in all other seasons, raising the mean daily maximum ΔT to 8-10.5 °C in Western Sydney, and 5-6.5 °C in inner Sydney. The dry warm (DW), and W conditions were mainly responsible for urban cooling (UC) at nighttime, bringing down the mean daily minimum ΔT to - 7.5 to - 10 °C in Western Sydney, and - 6 to - 7.5 °C in inner Sydney. The appropriate mitigation technologies can be planned based on this study to alleviate the higher daytime temperatures in the Sydney suburbs.

6.
PLoS One ; 15(12): e0243571, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33284850

RESUMO

The effects of heat waves (HW) are more pronounced in urban areas than in rural areas due to the additive effect of the urban heat island (UHI) phenomenon. However, the synergies between UHI and HW are still an open scientific question and have only been quantified for a few metropolitan cities. In the current study, we explore the synergies between UHI and HW in Seoul city. We consider summertime data from two non-consecutive years (i.e., 2012 and 2016) and ten automatic weather stations. Our results show that UHI is more intense during HW periods than non-heat wave (NHW) periods (i.e., normal summer background conditions), with a maximum UHI difference of 3.30°C and 4.50°C, between HW and NHW periods, in 2012 and 2016 respectively. Our results also show substantial variations in the synergies between UHI and HW due to land use characteristics and synoptic weather conditions; the synergies were relatively more intense in densely built areas and under low wind speed conditions. Our results contribute to our understanding of thermal risks posed by HW in urban areas and, subsequently, the health risks on urban populations. Moreover, they are of significant importance to emergency relief providers as a resource allocation guideline, for instance, regarding which areas and time of the day to prioritize during HW periods in Seoul.


Assuntos
Temperatura Alta/efeitos adversos , Raios Infravermelhos/efeitos adversos , Cidades , Monitoramento Ambiental/métodos , Estações do Ano , Seul/epidemiologia , População Urbana/tendências , Tempo (Meteorologia) , Vento
7.
Sci Total Environ ; 738: 139843, 2020 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-32531601

RESUMO

Extreme weather conditions affect human health. This study analyses the association of high and low temperature with cardiovascular and respiratory diseases on people over 65 years old for the years 2007 to 2015, in the region of Chania, Greece. The mortality is examined by time series analysis and further investigated by Poisson, and Negative Binomial regression, showing that one-lag in maximum temperature strongly affects the health of the elderly. Finally, cluster analysis is used from May to October, which is confirmed by discriminant analysis.


Assuntos
Doenças Cardiovasculares , Temperatura Baixa , Idoso , Grécia , Temperatura Alta , Humanos , Ilhas do Mediterrâneo , Mortalidade , Temperatura
8.
Environ Res ; 182: 109102, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31927298

RESUMO

The current study observed the effect of the synergistic interaction of urban heat island (UHI) and heatwaves (HWs) which is different from the sum of their separate effects on the medium-sized town of Nicosia, Cyprus. From an analysis of hourly meteorological records of eight consecutive years (2007-2014) we defined HWs with respect to air temperature (T95-over the 95th percentile air temperatures) as well as the heat index (HI65-heat index over 65degC) and studied their effects on the local UHI phenomenon. Both heatwave types were characterized by increased air temperature, lower wind speed and increased absolute humidity. HWs defined using the heat index (HI65) occurred more frequently and persisted for a longer period of time. UHI was intensified to about 0.9-1.3 °C during daytime hours under both HW definitions which was attributed to the evaporation of dew deposited on the upper top layer of soil that suppressed higher temperatures in the rural station due to a prolonged cooling effect. Model estimates of dew formation overnight and evaporation in the morning hours are hypothesized to be the main contributing factor in keeping rural air temperatures lower, thus increasing the UHI intensity. The results emphasize the critical role of latent cooling and evapotranspiration as a mitigation factor affecting extreme local temperatures.


Assuntos
Temperatura Alta , Cidades , Chipre , População Rural , Temperatura , Água
9.
Sci Total Environ ; 709: 136068, 2020 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-31869706

RESUMO

The urban heat island is a vastly documented climatological phenomenon, but when it comes to coastal cities, close to desert areas, its analysis becomes extremely challenging, given the high temporal variability and spatial heterogeneity. The strong dependency on the synoptic weather conditions, rather than on city-specific, constant features, hinders the identification of recurrent patterns, leading conventional predicting algorithms to fail. In this paper, an advanced artificial intelligence technique based on long short-term memory (LSTM) model is applied to gain insight and predict the highly fluctuating heat island intensity (UHII) in the city of Sydney, Australia, governed by the dualistic system of cool sea breeze from the ocean and hot western winds from the vast desert biome inlands. Hourly measurements of temperature, collected for a period of 18 years (1999-2017) from 8 different sites in a 50 km radius from the coastline, were used to train (80%) and test (20%) the model. Other inputs included date, time, and previously computed UHII, feedbacked to the model with an optimized time step of six hours. A second set of models integrated wind speed at the reference station to account for the sea breeze effect. The R2 ranged between 0.770 and 0.932 for the training dataset and between 0.841 and 0.924 for the testing dataset, with the best performance attained right in correspondence of the city hot spots. Unexpectedly, very little benefit (0.06-0.43%) was achieved by including the sea breeze among the input variables. Overall, this study is insightful of a rather rare climatological case at the watershed between maritime and desertic typicality. We proved that accurate UHII predictions can be achieved by learning from long-term air temperature records, provided that an appropriate predicting architecture is utilized.

10.
Artigo em Inglês | MEDLINE | ID: mdl-30044376

RESUMO

Extreme temperatures impose thermal stress on human health, resulting in increased hospitalizations and mortality rate. We investigated the circulatory and respiratory causes of death for the years 2007 to 2014 inclusive for the urban and rural areas of Nicosia, Cyprus under urban heatwave and non-heatwave conditions. Heatwaves were defined as four or more consecutive days with mean urban daily temperature over the 90th percentile threshold temperature of the eight investigated years. Lag period of adverse health effects was found to be up to three days following the occurrence of high temperatures. The relative risk (RR) for mortality rate under heatwave and non-heatwave conditions was found taking in consideration the lag period. The results showed the increase of mortality risk particularly for men of ages 65⁻69 (RR = 2.38) and women of ages 65⁻74 (around RR = 2.54) in the urban area, showing that women were more vulnerable to heat extremities. High temperatures were also associated with high ozone concentrations, but they did not impose an excess risk factor, as they did not reach extreme values. This analysis highlights the importance of preparing for potential heat related health impacts even in Cyprus, which is an island with frequent heatwaves.


Assuntos
Calor Extremo/efeitos adversos , Temperatura Alta , Mortalidade , Probabilidade , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Cidades , Chipre , Bases de Dados Factuais , Feminino , Transtornos de Estresse por Calor , Hospitalização , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Mortalidade/tendências , Ozônio/análise , Fatores de Risco , Adulto Jovem
11.
Sci Rep ; 8(1): 9191, 2018 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-29907840

RESUMO

Near-surface ozone is enhanced under particular chemical reactions and physical processes. This study showed the seasonal variation of near-surface ozone in Nicosia, Cyprus and focused in summers when the highest ozone levels were noted using a seven year hourly dataset from 2007 to 2014. The originality of this study is that it examines how ozone levels changed under heatwave conditions (defined as 4 consecutive days with daily maximum temperature over 39 °C) with emphasis on specific air quality and meteorological parameters with respect to non-heatwave summer conditions. The influencing parameters had a medium-strong positive correlation of ozone with temperature, UVA and UVB at daytime which increased by about 35% under heatwave conditions. The analysis of the wind pattern showed a small decrease of wind speed during heatwaves leading to stagnant weather conditions, but also revealed a steady diurnal cycle of wind speed reaching a peak at noon, when the highest ozone levels were noted. The negative correlation of NOx budget with ozone was further increased under heatwave conditions leading to steeper lows of ozone in the morning. In summary, this research encourages further analysis into the persistent weather conditions prevalent during HWs stimulating ozone formation for higher temperatures.

12.
Sci Total Environ ; 407(17): 4894-901, 2009 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-19500818

RESUMO

The aim of the present work is to study the occupants' exposure to fine particulate concentrations in ten nightclubs (NCs) in Athens, Greece. Measurements of PM(1) and PM(2.5) were made in the outdoor and indoor environment of each NC. The average indoor PM(1) and PM(2.5) concentrations were found to be 181.77 microg m(-3) and 454.08 microg m(-3) respectively, while the corresponding outdoor values were 11.04 microg m(-3) and 32.19 microg m(-3). Ventilation and resuspension rates were estimated through consecutive numerical experiments with an indoor air quality model and were found to be remarkably lower than the minimum values recommended by national standards. The relative effects of the ventilation and smoking on the occupants' exposures were examined using multiple regression techniques. It was found that given the low ventilation rates, the effect of smoking as well as the occupancy is of the highest importance. Numerical evaluations showed that if the ventilation rates were at the minimum values set by national standards, then the indoor exposures would be reduced at the 70% of the present exposure values.


Assuntos
Poluição do Ar em Ambientes Fechados , Exposição Ambiental , Nicotiana , Recreação , Fumar , Aerossóis , Grécia , Humanos , Tamanho da Partícula , Saúde da População Urbana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...