Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Environ Res ; 224: 115478, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36796611

RESUMO

Manganese (Mn), despite being a trace element necessary in small quantities for the correct functioning of the organism, at higher concentrations can induce health disorders, mainly in motor and cognitive functions, even at levels found in non-occupational environments. For this reason, US EPA guidelines define safe reference doses/concentrations (RfD/RfC) for health. In this study, the individualised health risk of exposure to Mn through different media (air, diet, soil) and routes of entry into the organism (inhalation, ingestion and dermal absorption) was assessed according to the procedure defined by the US EPA. Calculations related to Mn present in ambient air were made on the basis of data obtained from size-segregated particulate matter (PM) personal samplers carried by volunteers recruited in a cross-sectional study conducted in the Santander Bay (northern Spain), where an industrial source of airborne Mn is located. Individuals residing in the vicinity of the main Mn source (within 1.5 km) were found to have a hazard index (HI) higher than 1, indicating that there is a potential risk for these subjects to develop health alterations. Also, people living in Santander, the capital of the region, located 7-10 km from the Mn source, may have some risk (HI > 1) under some wind conditions (SW). In addition, a preliminary study of media and routes of entry into the body confirmed that inhalation of PM2.5-bound Mn is the most important route contributing to the overall non-carcinogenic health risk related to environmental Mn.


Assuntos
Poluentes Atmosféricos , Manganês , Humanos , Manganês/análise , Monitoramento Ambiental/métodos , Estudos Transversais , Exposição Ambiental/análise , Material Particulado/análise , Medição de Risco , Poluentes Atmosféricos/análise
2.
Environ Geochem Health ; 44(12): 4595-4618, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35190915

RESUMO

The environmental exposure to trace metal(loid)s (As, Cd, Cu, Fe, Mn, Pb, and Zn) was assessed near a ferromanganese alloy plant using filters from personal particulate matter (PM) samplers (bioaccessible and non-bioaccessible fine and coarse fractions) and whole blood as short-term exposure markers, and scalp hair and fingernails as long-term biomarkers, collected from volunteers (n = 130) living in Santander Bay (northern Spain). Bioaccessible and non-bioaccessible metal(loid) concentrations in coarse and fine PM from personal samplers were determined by ICP-MS after extraction/digestion. Metal(loid) concentration in biomarkers was measured after alkaline dilution (whole blood) and acid digestion (fingernails and scalp hair) by ICP-MS as well. Results were discussed in terms of exposure, considering the distance to the main Mn source, and sex. In terms of exposure, significant differences were found for Mn in all the studied fractions of PM, As in whole blood, Mn and Cu in scalp hair and Mn and Pb in fingernails, with all concentrations being higher for those living closer to the Mn source, with the exception of Cu in scalp hair. Furthermore, the analysis of the correlation between Mn levels in the studied biomarkers and the wind-weighted distance to the main source of Mn allows us to conclude that scalp hair and mainly fingernails are appropriate biomarkers of long-term airborne Mn exposure. This was also confirmed by the significant positive correlations between scalp hair Mn and bioaccessible Mn in coarse and fine fractions, and between fingernails Mn and all PM fractions. This implies that people living closer to a ferromanganese alloy plant are exposed to higher levels of airborne metal(loid)s, mainly Mn, leading to higher levels of this metal in scalp hair and fingernails, which according to the literature, might affect some neurological outcomes. According to sex, significant differences were observed for Fe, Cu and Pb in whole blood, with higher concentrations of Fe and Pb in males, and higher levels of Cu in females; and for Mn, Cu, Zn, Cd and Pb in scalp hair, with higher concentrations in males for all metal(loid)s except Cu.


Assuntos
Cádmio , Oligoelementos , Humanos , Masculino , Feminino , Cádmio/análise , Chumbo/análise , Oligoelementos/análise , Material Particulado/análise , Biomarcadores , Ligas/análise , Monitoramento Ambiental
3.
Appl Radiat Isot ; 178: 109936, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34592691

RESUMO

Investigations regarding the feasibility, reliability, and accuracy of Fricke gel dosimeter layers for stereotactic radiosurgery are presented. A representative radiosurgery plan consisting of two targets has been investigated. Absorbed dose distributions measured using radiochromic films and gelatin Fricke Gel dosimetry in layers have been compared with dose distributions calculated by using a treatment planning system and Monte Carlo simulations. The different dose distributions have been compared by means of the gamma index demonstrating that gelatin Fricke gel dosimeter layers showed agreements of 100%, 100%, and 93%, with dose and distance tolerances of 2% and 2 mm, with respect to film dosimetry, treatment planning system and Monte Carlo simulations, respectively. The capability of the developed system for three-dimensional dose mapping was shown, obtaining promising results when compared with well-established dosimetry methods. The obtained results support the viability of Fricke gel dosimeter layers analyzed by optical methods for stereotactic radiosurgery.


Assuntos
Corantes Fluorescentes/química , Géis/química , Fenóis/química , Dosímetros de Radiação/normas , Radiocirurgia/métodos , Sulfóxidos/química , Estudos de Viabilidade , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Reprodutibilidade dos Testes
4.
Appl Radiat Isot ; 175: 109787, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34102413

RESUMO

This work evaluates experimentally the dose enhancement factor (DEF) and dose sparing factor (DSF) due to radiation self-shielding, produced by Gd infused in tumor phantom irradiated with brachytherapy HDR 192Ir source by Gafchromic EBT3 dosimeter. The phantom was made of a set of solid water slabs (30 × 30 × 1.0) cm3 and three acrylic slabs of (30 × 30 × 0.5) cm3 machined to contain in the central axis acrylics vials of (1 × 1 × 5) cm3. The first and second acrylic vials were filled with an identical Gd solution of 0, 10 and 20 mg/ml, simulating Gd-doped and undoped tumor, and the third vial was filled in all the measurement only with water, representing an organ at risk. Additional solid water slabs were used to complete a phantom of (30 × 30 × 16) cm3. In the phantom center an acrylic slab was machined to introduce the 2.5 mm flexible guide tube of GammaMed plus iX equipment and positioning the 192Ir source in the phantom central part. EBT3 fragments of (0.9 × 4) cm2 were placed on the inner edge of the second and third vials to measure dose enhancement and dose sparing simultaneously. Phantom CT images were acquired for planning and to prescribe a dose of 6.0 Gy at 2.0 cm of the source, achieving an isodose curve of 44.5% at 3.0 cm (positions of the EBT3 films). Additionally, Monte Carlo simulation of the identical experimental setup was implemented to compare measurement values. The results showed the feasibility of measuring a DEF of 1.15 ± 0.05 in 20 mg/ml of Gd concentration consistent with the Monte Carlo DEF of 1.112 ± 0.005 for the same concentration. DEF value for concentration of 10 mg/ml would not be detected (1.00 ± 0.04) by an expected under measurement of the EBT3 films associated with the non-detection of photoelectrons and Auger electrons of very low energy that cannot reach the radiosensitive substrate.


Assuntos
Braquiterapia/métodos , Gadolínio/análise , Radioisótopos de Irídio/administração & dosagem , Neoplasias/radioterapia , Dosímetros de Radiação , Simulação por Computador , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica
5.
Chemosphere ; 267: 129181, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33340883

RESUMO

The bioaccessibility of metal(loid)s in ambient particulate matter (PM) has been recently used to represent the risk of inhalation exposure. Nevertheless, different methodological factors affect the bioaccessibility values; among these, the type and composition of surrogate biological fluids and the liquid to solid ratio have been revealed to be the most important. To better understand how these methodological aspects affect the bioaccessibility, a reference material corresponding to urban dust (SRM1648a) was contacted with synthetic biological fluids commonly used in the literature representing surrogate fluids that may interact with fine (Gamble's solutions, artificial lysosomal fluid (ALF)) and coarse particles (gastric fluid), for liquid to solid (L/S) ratios ranging from 500 to 20,000. Visual MINTEQ 3.1. was used to enhance the discussion on how the solubility of metals in the leaching solution depends on the composition of the simulated fluids and the speciation of metals. The results obtained indicate that a small change in the composition of Gamble's solution (the presence of glycine) may increase significantly the bioaccessibility at a L/S ratio of 5,000. The highest bioaccessibility of most of the studied metal(loid)s at a L/S ratio of 5,000 was found for ALF fluid. The study of the effect of the L/S ratio showed that metal(loid)s bioaccessibility in Gamble's fluid increased logarithmically with increasing L/S ratio, while it remained practically constant in ALF and gastric fluid. This different behavior is explained assuming that the leaching of metal(loid)s in Gamble's solution is solubility-controlled, while in ALF and gastric fluid is availability-controlled.


Assuntos
Poeira , Oligoelementos , Exposição por Inalação/análise , Metais , Material Particulado
6.
PLoS One ; 15(12): e0243849, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33301518

RESUMO

OBJECTIVE: To evaluate the usefulness of a new marker, pentraxin, as a prognostic marker in septic shock patients. MATERIALS AND METHODS: Single-centre prospective observational study that included all consecutive patients 18 years or older who were admitted to the intensive care unit (ICU) with septic shock. Serum levels of procalcitonin (PCT), C-reactive protein (CRP) and pentraxin (PTX3) were measured on ICU admission. RESULTS: Seventy-five septic shock patients were included in the study. The best predictors of in-hospital mortality were the severity scores: SAPS II (AUC = 0.81), SOFA (AUC = 0.79) and APACHE II (AUC = 0.73). The ROC curve for PTX3 (ng/mL) yielded an AUC of 0.70, higher than the AUC for PCT (0.43) and CRP (0.48), but lower than lactate (0.79). Adding PTX3 to the logistic model increased the predictive capacity in relation to SAPS II, SOFA and APACHE II for in-hospital mortality (AUC 0.814, 0.795, and 0.741, respectively). In crude regression models, significant associations were found between in-hospital mortality and PTX3. This positive association increased after adjusting for age, sex and immunosuppression: adjusted OR T3 for PTX3 = 7.83, 95% CI 1.35-45.49, linear P trend = 0.024. CONCLUSION: Our results support the prognostic value of a single determination of plasma PTX3 as a predictor of hospital mortality in septic shock patients.


Assuntos
Proteína C-Reativa/metabolismo , Unidades de Terapia Intensiva , Admissão do Paciente , Componente Amiloide P Sérico/metabolismo , Choque Séptico/sangue , Idoso , Área Sob a Curva , Biomarcadores/sangue , Intervalos de Confiança , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Curva ROC , Análise de Regressão , Índice de Gravidade de Doença
7.
Appl Radiat Isot ; 163: 109194, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32392167

RESUMO

In this work, the benefits in terms of dose enhancement and dose sparing via radiation shielding are evaluated, for a combined irradiation scheme with sources of 241Am and tumor-infused with Gd agents, regarding conventional 192Ir treatment. Monte Carlo simulations using PENELOPE code were implemented for endocavitary brachytherapy geometries, configuring a pelvis phantom of 15 cm radius and 30 cm length. Inside, it was defined cylindrical tumor phantoms of 2 cm radius and 4 cm-6 cm length (simulating initial stages) as well as tumors of extensive volume (2.5 and 3.0 cm radius) and difficult coverage. Tumor phantoms were doped with 68 mM and 138 mM of Gd in order to assess the effects of enhancement and protection based on the concentration and emission energy of the isotope. Obtained results for the first tumor group, shown the feasibility of achieving dose enhancements of 94.3%-117% and 160%-194% for 68 mM and 138 mM of Gd infused into the tumor and irradiation with 241Am, respectively. Similarly, reduced dose enhancements of 3.5-5.7% y 8.9%-11.2% for 68 mM and 138 mM of Gd are attained with 192Ir. In terms of dose sparing outer the tumor, the radiation shielding and dose enhancement allowed a higher reduction in the dose by 241Am of 17%-24% for 68 mM and 21%-32% for 138 mM of Gd, and non-negligible dose sparing are produced too by 192Ir of 2% and 5% for the same concentration of Gd. For the second tumors group, the combined use of 241Am and Gd agents simultaneously allowed to improve coverage and reduce the healthy tissue dose, showing the obtained results the possibility of achieving coverage of 95% of the prescribed dose in 100% of tumor volume together with dose sparing factor of 6-21% reduction in isodose of the studied point and dose enhancements of 75%-158% at the prescription point.


Assuntos
Amerício/administração & dosagem , Braquiterapia/métodos , Gadolínio/administração & dosagem , Neoplasias/radioterapia , Dosagem Radioterapêutica , Humanos , Método de Monte Carlo , Imagens de Fantasmas
8.
Rev Esp Quimioter ; 33(3): 200-206, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32345004

RESUMO

OBJECTIVE: Bloodstream Infections has become in one of the priorities for the antimicrobial stewardship teams due to their high mortality and morbidity rates. Usually, the first antibiotic treatment for this pathology must be empirical, without microbiology data about the microorganism involved. For this reason, the population studies about the etiology of bacteremia are a key factor to improve the selection of the empirical treatment, because they describe the main microorganisms associated to this pathology in each area, and this data could facilitate the selection of correct antibiotic therapy. METHODS: This study describes the etiology of bloodstream infections in the Southeast of Spain. The etiology of bacteremia was analysed by a retrospective review of all age-ranged patients from every public hospital in the Autonomous Community of Valencia (approximately 5,000,000 inhabitants) for five years. RESULTS: A total of 92,097 isolates were obtained, 44.5% of them were coagulase-negative staphylococci. Enterobacteriales was the most prevalent group and an increase in frequency was observed along the time. Streptococcus spp. were the second microorganisms more frequently isolated. Next, the most prevalent were Staphylococcus aureus and Enterococcus spp., both with a stable incidence along the study. Finally, Pseudomonas aeruginosa was the fifth microorganism more frequently solated. CONCLUSIONS: These data constitute a useful tool that can help in the choice of empirical treatment for bloodstream infections, since the knowledge of local epidemiology is key to prescribe a fast and appropriate antibiotic therapy, aspect capital to improve survival.


Assuntos
Sepse/etiologia , Sepse/microbiologia , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Gestão de Antimicrobianos , Criança , Pré-Escolar , Análise por Conglomerados , Feminino , Infecções por Bactérias Gram-Negativas/epidemiologia , Infecções por Bactérias Gram-Negativas/microbiologia , Infecções por Bactérias Gram-Positivas/epidemiologia , Infecções por Bactérias Gram-Positivas/microbiologia , Tamanho das Instituições de Saúde , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Prevalência , Estações do Ano , Sepse/epidemiologia , Fatores Sexuais , Espanha/epidemiologia , Adulto Jovem
9.
Rev Neurol ; 69(8): 307-316, 2019 Oct 16.
Artigo em Espanhol | MEDLINE | ID: mdl-31588984

RESUMO

INTRODUCTION: Cerebral palsy is one of the main causes of disability in childhood. Resistive therapy has proved to be beneficial in increasing strength and motor function in these patients, but its impact on gait is not yet clear. AIM: To analyse the impact of resistive therapy on improving gait through a systematic review and meta-analysis. PATIENTS AND METHODS: A search was conducted in Medline, ISI Web of Knowledge and PEDro for clinical trials in which resistive therapy was used and at least one gait parameter was assessed. RESULTS: Nine controlled studies and one single-arm study were identified. In terms of pre-post difference, the overall intragroup effect was in favour of the intervention, with null heterogeneity (standardised mean difference: 0.32; 95% CI: 0.19-0.44). The standardised mean differences were also positive as they restricted each of the gait parameters analysed: 0.36, 0.35 and 0.22 for step cadence, gait speed and step length, respectively. As regards the difference between groups, the results showed high heterogeneity, and the mean difference was also favourable, especially for speed (7.3 cm/s; 95% CI: 2.67-11.92), cadence (5.66 steps; 95% CI: 1.86-9.46) and, to a lesser extent, step length (3.25 cm; 95% CI: -1.69 to 8.19). CONCLUSION: The results support the impact of resistive therapy on gait improvement, especially in terms of the gait speed and step cadence parameters.


TITLE: Impacto de la terapia resistida sobre los parametros de la marcha en niños con paralisis cerebral: revision sistematica y metaanalisis.Introduccion. La paralisis cerebral es una de las principales causas de discapacidad en la infancia. La terapia resistida ha demostrado beneficio en el aumento de la fuerza y la funcion motora de estos pacientes, pero su impacto en la marcha aun no esta claro. Objetivo. Analizar el impacto de la terapia resistida sobre la mejora en la marcha, mediante una revision sistematica y metaanalisis. Pacientes y metodos. Se realizo una busqueda en Medline, ISI Web of Knowledge y PEDro de ensayos clinicos en los que se intervino con terapia resistida y se evaluo al menos un parametro de marcha. Resultados. Se identificaron nueve estudios controlados y uno de un solo brazo. En cuanto a la diferencia pre-post, el efecto global intragrupo fue a favor de la intervencion, con una heterogeneidad nula (diferencia estandarizada de medias: 0,32; IC 95%: 0,19-0,44). Las diferencias estandarizadas de medias fueron asimismo positivas al restringir a cada uno de los parametros de marcha analizados: 0,36, 0,35 y 0,22 para la velocidad de la marcha, la cadencia del paso y la longitud del paso, respectivamente. En relacion con la diferencia entre grupos, los resultados mostraron una heterogeneidad elevada y la diferencia de medias tambien fue favorable, especialmente para la velocidad (7,3 cm/s; IC 95%: 2,67-11,92) y la cadencia (5,66 pasos; IC 95%: 1,86-9,46), y en menor medida para la longitud del paso (3,25 cm; IC 95%: -1,69 a 8,19). Conclusion. Los resultados apoyan el impacto de la terapia resistida en la mejora en la marcha, especialmente en cuanto a los parametros de velocidad de la marcha y cadencia del paso.


Assuntos
Paralisia Cerebral/fisiopatologia , Paralisia Cerebral/reabilitação , Marcha , Treinamento Resistido , Humanos , Resultado do Tratamento
10.
Appl Radiat Isot ; 154: 108857, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31434044

RESUMO

This work reports the experimental determination of dose enhancement produced in phantoms containing target volumes doped with Gadolinium and irradiated with low-energy X-ray beams. EBT3 Gafchromic films were immersed into 5 ml target volumes to simulate tumor filling with 100% ultra-pure water (blank sample) and ultra-pure water infused with Gd solution (Omniscan®) in different concentration (9-24 mg/ml). The dose enhancement due to excitation of Gd K-edge (50.2 keV) was evaluated in terms of the increment in optical density, obtained by a Spectrophotometer-Gafchromic-EBT3 dosimetry system calibrated in terms of the dose-response for 1-8 Gy range. The dose enhancement was evaluated in two condition: a beam quality with spectrum above the absorption edge in a medium with and without Gd; and two beam qualities (above and below the absorption edge) in a medium with a fixed Gd concentration (18 mg/ml). The obtained results confirmed increments in relative dose enhancement according to Gd concentrations up to 18 mg/ml, with a dose enhancement of 1.1 Gy and an average percentage enhancement of 28.4%. For higher values of concentration, the attenuation interaction of the primary beam is more relevant instead of dose enhancement process. On the other hand, the dose enhancement obtained to comparison the spectra above and below the absorption edge, shown results up to 3.3 Gy of enhancement and average percentage enhancement of 88%.

11.
BMJ Open ; 9(8): e026899, 2019 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-31420385

RESUMO

OBJECTIVE: To determine the percentage of pregnant women who are potential candidates for a normal birth in the region of Cantabria, Spain. Also, to compare the main clinical practice outcome indicators and the rates of maternal and neonatal morbidity among the group of candidate women versus non-candidates. DESIGN: A cross-sectional study. SETTING: A tertiary Hospital in Cantabria (Northern region of Spain). PARTICIPANTS: The study population comprised the total number of hospital births that took place between 1 January 2014 and 31 December 2014 (n=3315). RESULTS: Secondary registers were accessed to review the main indicators of care and the outcome of births. The χ2 test or the Student's t-test were used to compare both groups for the categorical and continuous variables, respectively. In total, 1863 births (56.20%) were candidates for applying the strategy of care for a normal birth. In 50.86% of these candidate births, an episiotomy was performed, compared with 60.96% in the group of non-candidates (p<0.001). Regarding caesarean sections, these were carried out in 19.32% of the candidate births, compared with 26.79% of non-candidate births (p<0.001). Furthermore, there were statistically significant differences between the groups according to the type of birth, the need for instrumental birthing methods, the existence of perineal tears, Apgar scores and the requirement for the infant to be admitted to the neonatal intensive care unit. CONCLUSIONS: Our results suggest a differential clinical practice, in line with the recommendations of the Clinical Practice Guidelines for Care of Normal Birth. Nonetheless, improvements are necessary regarding the care provided to women and infants, as the percentages of episiotomies and caesarean sections are still high when compared with current standards and compared with other reports.


Assuntos
Parto Obstétrico , Doenças do Recém-Nascido/epidemiologia , Complicações do Trabalho de Parto/epidemiologia , Adulto , Estudos Transversais , Episiotomia/estatística & dados numéricos , Feminino , Humanos , Recém-Nascido , Seleção de Pacientes , Guias de Prática Clínica como Assunto , Gravidez , Resultado da Gravidez , Estudos Retrospectivos , Espanha , Centros de Atenção Terciária
12.
Appl Radiat Isot ; 151: 46-51, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31158705

RESUMO

A new technique, based on in-vivo energy dispersive X-ray fluorescence (EDXRF), has been developed to gadolinium (Gd) concentrations identification in planar X-ray fluorescence (XRF) images. Higher signal-to-noise (SNR) ratios while keeping a low radiation dose were achieved. Experimental validation was performed using tissue equivalent phantoms under two different data acquisition criteria. The first criteria consisted on acquiring the energy spectra from different experimental narrow spectrum beam (FWHM = 2.5 keV) with peak central energy above the L edge energy and determining the spectrum which producing Lowest-Limit-of-Detection (Lowest-LoD) for a specific acquisition time. This also provided the minimum dose expected under the condition of minimum irradiation time. The second criteria consisted on measuring the surface dose required to obtain a specific LoD by different narrow spectrum beam, providing the Lowest-Dose setting. Surface (2D) Gd-doped tissue-equivalent phantoms scanning were performed according to optimized scenarios: Lowest-LoD setting (obtaining to central energy of 10.9 keV) and Lowest-Dose setting (obtaining to central energy 12.9 keV). 625 pixel images were acquired in two different conditions: a pre-defined time (5 s) per pixel was set in the first approach, whereas a pre-defined total surface dose (4 mGy) was set to the second approach. According to the results obtained for the first approach, a 58 times reduction was observed when comparing SNR between the Lowest-LoD and Lowest-Dose settings. On the other hand, for the second approach pre-defining total dose during the whole examination, the best SNR was obtained for the Lowest-Dose configuration exhibiting a 42% of increment respecting to the Lowest-LoD configuration and 47 times higher when compared with the limit case of no optimization.


Assuntos
Gadolínio/análise , Espectrometria por Raios X/instrumentação , Gadolínio/uso terapêutico , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Fótons , Radioterapia/métodos , Dosagem Radioterapêutica , Razão Sinal-Ruído
13.
J Crit Care ; 48: 183-190, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30218958

RESUMO

PURPOSE: Current guidelines favor 4F-PCC over plasma for warfarin reversal. Uncertainty remains on its thrombotic risk and hemostatic effectiveness when used for direct-acting oral anticoagulants (DOACs), transplants, massive transfusion protocols (MTP), and non-anticoagulated patients. This study sought to evaluate the tolerability and effectiveness of 4F-PCC in a real-world setting. MATERIALS AND METHODS: This was a retrospective study of adults who received 4F-PCC from March 2014 to December 2015. The primary outcome was thromboembolic events within 14 days. The secondary outcome was hemostatic effectiveness within 24 h. RESULTS: The final analysis included 212 patients. Primary reversal indication was major bleed in 165 patients (77.8%) and emergent surgery in 47 patients (22.2%). Thromboembolism occurred in 22 patients (10.4%), more in emergent surgery than major bleed reversals (17% and 8.5%, respectively). MTP and heart transplant patients had the highest thromboembolic event rates (44.4% and 28.6%, respectively). Hemostatic effectiveness was 65.8% (68% in major bleed and 58.1% in emergent surgery). DOAC patients achieved hemostasis most often (78.9%). Administration of any reversal agent, major surgery within 14 days, and MTP activation were significant predictors of thromboembolism. CONCLUSIONS: Use of 4F-PCC in this real-world setting was associated with variable thromboembolic and hemostatic effectiveness rates based on the indication for reversal.


Assuntos
Anticoagulantes/efeitos adversos , Fatores de Coagulação Sanguínea/uso terapêutico , Hemorragia/tratamento farmacológico , Varfarina/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Fatores de Coagulação Sanguínea/administração & dosagem , Fatores de Coagulação Sanguínea/efeitos adversos , Feminino , Hemorragia/induzido quimicamente , Hemorragia/etiologia , Hemostasia , Humanos , Coeficiente Internacional Normatizado , Prontuários Médicos , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
14.
Appl Radiat Isot ; 141: 210-218, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29678602

RESUMO

This work reports the experimental development of an integral Gd-infused dosimeter suitable for Gd dose enhancement assessment along with Monte Carlo simulations applied to determine the dose enhancement by radioactive and X-ray sources of interest in conventional and electronic brachytherapy. In this context, capability to elaborate a stable and reliable Gd-infused dosimeter was the first goal aimed at direct and accurate measurements of dose enhancement due to Gd presence. Dose-response was characterized for standard and Gd-infused PAGAT polymer gel dosimeters by means of optical transmission/absorbance. The developed Gd-infused PAGAT dosimeters demonstrated to be stable presenting similar dose-response as standard PAGAT within a linear trend up to 13 Gy along with good post-irradiation readout stability verified at 24 and 48 h. Additionally, dose enhancement was evaluated for Gd-infused PAGAT dosimeters by means of Monte Carlo (PENELOPE) simulations considering scenarios for isotopic and X-ray generator sources. The obtained results demonstrated the feasibility of obtaining a maximum enhancement around of (14 ±â€¯1)% for 192Ir source and an average enhancement of (70 ±â€¯13)% for 241Am. However, dose enhancement up to (267 ±â€¯18)% may be achieved if suitable filtering is added to the 241Am source. On the other hand, optimized X-ray spectra may attain dose enhancements up to (253 ±â€¯22) %, which constitutes a promising future alternative for replacing radioactive sources by implementing electronic brachytherapy achieving high dose levels.


Assuntos
Braquiterapia/métodos , Gadolínio/administração & dosagem , Dosagem Radioterapêutica , Amerício , Braquiterapia/estatística & dados numéricos , Simulação por Computador , Relação Dose-Resposta à Radiação , Estudos de Viabilidade , Géis , Humanos , Radioisótopos de Irídio , Método de Monte Carlo , Polímeros/administração & dosagem , Dosímetros de Radiação/estatística & dados numéricos , Radiometria/estatística & dados numéricos , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Raios X
15.
Appl Radiat Isot ; 141: 187-192, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29555377

RESUMO

Conventional radiotherapy is mainly applied by linear accelerators. Although linear accelerators provide dual (electron/photon) radiation beam modalities, both of them are intrinsically produced by a megavoltage electron current. Modern radiotherapy treatment techniques are based on suitable devices inserted or attached to conventional linear accelerators. Thus, precise control of delivered beam becomes a main key issue. This work presents an integral description of electron beam deflection control as required for novel radiotherapy technique based on convergent photon beam production. Theoretical and Monte Carlo approaches were initially used for designing and optimizing device´s components. Then, dedicated instrumentation was developed for experimental verification of electron beam deflection due to the designed magnets. Both Monte Carlo simulations and experimental results support the reliability of electrodynamics models used to predict megavoltage electron beam control.


Assuntos
Elétrons/uso terapêutico , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Alta Energia/métodos , Simulação por Computador , Humanos , Método de Monte Carlo , Aceleradores de Partículas , Imagens de Fantasmas , Fótons/uso terapêutico , Planejamento da Radioterapia Assistida por Computador/instrumentação , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Radioterapia de Alta Energia/instrumentação , Radioterapia de Alta Energia/estatística & dados numéricos
16.
Appl Radiat Isot ; 129: 19-27, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28802154

RESUMO

The present work is devoted to optimizing the sensitivity-doses relationship of a bench-top EDXRF system, with the aim of achieving a detection limit of 0.010mg/ml of gold nanoparticles in tumor tissue (clinical values expected), for doses below 10mGy (value fixed for in vivo application). Tumor phantoms of 0.3cm3 made of a suspension of gold nanoparticles (15nm AurovistTM, Nanoprobes Inc.) were studied at depths of 0-4mm in a tissue equivalent cylindrical phantom. The optimization process was implemented configuring several tube voltages and aluminum filters, to obtain non-symmetrical narrow spectra with fixed FWHM of 5keV and centered among the 11.2-20.3keV. The used statistical figure of merit was the obtained sensitivity (with each spectrum at each depth) weighted by the delivered surface doses. The detection limit of the system was determined measuring several gold nanoparticles concentrations ranging from 0.0010 to 5.0mg/ml and a blank sample into tumor phantoms, considering a statistical fluctuation within 95% of confidence. The results show the possibility of obtaining a detection limit for gold nanoparticles concentrations around 0.010mg/ml for surface tumor phantoms requiring doses around 2mGy.

17.
SEMERGEN, Soc. Esp. Med. Rural Gen. (Ed. Impr.) ; 43(5): 364-374, jul.-ago. 2017. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-164898

RESUMO

Introducción/objetivo. Una de las principales limitaciones en los estudios sobre la EPOC en bases de datos sanitarias podría ser la baja calidad de la información contenida en ellas. Nuestro principal objetivo fue evaluar la fiabilidad del diagnóstico de EPOC en Atención Primaria. En segundo término, describir las características de los pacientes en función de la conformidad del diagnóstico. Material y métodos. Estudio transversal usando bases de datos sanitarias de Cantabria. De una muestra preseleccionada se obtuvieron 1.457 pacientes etiquetados con EPOC en la historia clínica. Se verificó el diagnóstico en las mismas bases de datos y se crearon 3 grupos: EPOC-confirmada, EPOC no confirmada-no descartada y error-diagnóstico. Fueron recogidas variables descriptivas, clínicas, comorbilidades y tratamientos. Resultados. El diagnóstico de EPOC fue confirmado en 766 pacientes: 52,6% (IC 95%: 50,0-55,2). La frecuencia del error-diagnóstico fue del 7,2% (IC 95%: 5,8-8,6). El porcentaje de este sobrediagnóstico fue mayor en mujeres. La edad, el hábito tabáquico, la severidad en función del FEV1 y la frecuencia y gravedad de las agudizaciones fueron mayores en el grupo de EPOC-confirmada (p<0,001). En los errores-diagnósticos se registraron una media de 1,95 episodios en los últimos 4 años. Los corticoides inhalados estaban prescritos en el 76,9% de los pacientes con EPOC-confirmada y en el 41,9% de los errores-diagnósticos. Conclusiones. La fiabilidad del registro del diagnóstico de EPOC fue deficiente, con solo un 52,6% de certeza diagnóstica. En todos los grupos constó la prescripción de tratamientos para la EPOC de forma estable, destacando el uso de corticoides inhalados (AU)


Introduction/objective. One of main limitations in studies of COPD in health databases could be the low quality of the information. Our first aim was evaluate reliability of the registry of COPD diagnosis register in Primary Care. A description and comparison is also presented of the characteristics of the patients according to the diagnostic confirmation. Material and methods. A cross-sectional study using healthcare databases of Cantabria. A pre-selected sample of 1,457 patients was obtained in which COPD diagnosis was specifically registered. COPD confirmation was classified into confirmed COPD, not confirmed-not rejected COPD, and diagnostic error (over-diagnosis). Descriptive and clinical characteristics, comorbidities, and treatments were collected in each group. Results. COPD was confirmed in 766 patients: 52.6% (95%CI: 49.9-55.2). Prevalence of over-diagnosis was 7.2% (95%CI: 5.9-8.6). There were statistically significant gender differences. In the COPD confirmed group age, tobacco consumption and severity according to FEV1 was higher. An average of 1.95 bronchial exacerbations during the last 4years was observed among diagnostic errors. Inhaled corticosteroids were prescribed in 74.9% of COPD confirmed patients, and in 41.9% of over-diagnosed patients. Conclusions. The reliability of the COPD register was deficient, with only 52.6% with a confirmed diagnosis. Stable treatment for COPD was prescribed in all groups, highlighting the use of inhaled corticosteroids (AU)


Assuntos
Humanos , Masculino , Feminino , Idoso , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Atenção Primária à Saúde , Corticosteroides/uso terapêutico , Registros/normas , Reprodutibilidade dos Testes , Estudos Transversais/métodos
18.
Semergen ; 43(5): 364-374, 2017.
Artigo em Espanhol | MEDLINE | ID: mdl-27692678

RESUMO

INTRODUCTION/OBJECTIVE: One of main limitations in studies of COPD in health databases could be the low quality of the information. Our first aim was evaluate reliability of the registry of COPD diagnosis register in Primary Care. A description and comparison is also presented of the characteristics of the patients according to the diagnostic confirmation. MATERIAL AND METHODS: A cross-sectional study using healthcare databases of Cantabria. A pre-selected sample of 1,457 patients was obtained in which COPD diagnosis was specifically registered. COPD confirmation was classified into confirmed COPD, not confirmed-not rejected COPD, and diagnostic error (over-diagnosis). Descriptive and clinical characteristics, comorbidities, and treatments were collected in each group. RESULTS: COPD was confirmed in 766 patients: 52.6% (95%CI: 49.9-55.2). Prevalence of over-diagnosis was 7.2% (95%CI: 5.9-8.6). There were statistically significant gender differences. In the COPD confirmed group age, tobacco consumption and severity according to FEV1 was higher. An average of 1.95 bronchial exacerbations during the last 4years was observed among diagnostic errors. Inhaled corticosteroids were prescribed in 74.9% of COPD confirmed patients, and in 41.9% of over-diagnosed patients. CONCLUSIONS: The reliability of the COPD register was deficient, with only 52.6% with a confirmed diagnosis. Stable treatment for COPD was prescribed in all groups, highlighting the use of inhaled corticosteroids.


Assuntos
Corticosteroides/administração & dosagem , Atenção Primária à Saúde , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Uso de Tabaco/epidemiologia , Administração por Inalação , Idoso , Estudos Transversais , Bases de Dados Factuais , Erros de Diagnóstico/estatística & dados numéricos , Feminino , Volume Expiratório Forçado , Humanos , Masculino , Uso Excessivo dos Serviços de Saúde/estatística & dados numéricos , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Sistema de Registros , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Espanha
19.
Int. j. morphol ; 34(4): 1232-1238, Dec. 2016. ilus
Artigo em Espanhol | LILACS | ID: biblio-840873

RESUMO

Al realizarse estudios sobre muestras óseas para analizar características como dureza, densidad y salud, se suelen utilizar equipamientos que permiten la cuantificación de la densidad electrónica, proporcional a la densidad másica, que se relaciona directamente con la densidad mineral ósea. El test conocido como densitometría ósea se suele realizar con equipos de rayos X, ultrasonido o por medio de la utilización de isótopos radioactivos. Este estudio cuantifica la cantidad mineral ósea por superficie y suele ser utilizado para evaluar, entre otros, riesgos de fracturas o estado de osteoporosis. La técnica de tomografía computada utiliza imágenes bidimensionales de rayos X y métodos de reconstrucción tomográfica implementados en algoritmos computacionales para obtener información de la estructura interna de un objeto, de forma no destructiva. Equipamientos especialmente desarrollados logran obtener imágenes con resolución sub-milimétrica, dando lugar a la técnica conocida como micro-tomografía. La posibilidad de estudiar estructuras óseas con este grado de resolución y obtener imágenes morfológicas tridimensionales con información de la densidad electrónica, presenta una importante opción para estudios específicos sobre, entre otros, crecimiento de hueso y estudios de nuevos componentes que permiten acelerar el crecimiento de tejidos dañados. En el presente trabajo se analizan muestras óseas del cráneo de conejos donde se han dañado determinadas zonas y se han injertado diferentes sustancias tendientes a evaluar respuestas de reparación de tejido óseo. El análisis se realiza a los fines de estudiar la performance de la técnica de micro-tomografía desarrollada en laboratorio con el objetivo de observar su potencialidad en este tipo de estudios y la capacidad de estos análisis en la caracterización de las propiedades físicas de este tipo de muestras.


When performing studies on bone samples aiming at analyzing its physical characteristics such as hardness, density and health, typically it is used to utilize different equipment for the quantification of electron density, which results proportional to mass density, which is directly related to bone mineral density. The test known as bone densitometry is usually done using X-ray equipment, ultrasound or through the utilization of radioactive isotopes. This analysis quantifies the amount of mineral bone on a surface and is usually implemented to assess, among others, risks of fractures or the osteoporosis state in a patient. The computed tomography technique uses two-dimensional X-ray images and tomographic reconstruction methods implemented on computational algorithms to obtain information about the internal structure of an object in a nondestructively way. Specially developed equipment able to obtain images with sub-millimeter resolution, results in the technique known as micro-tomography. The ability to study bone structures at sub-millimeter levels and obtain three-dimensional morphological images with electron density information, presents an important option for specific studies on bone growth and studies on new components that allow the growth of damaged tissues. In this paper rabbits cranium bone samples where certain areas have been damaged and have been filled with different substances specially designed to evaluate repair responses on bone tissue are analyzed. The analysis is performed in order to study the performance of the micro-tomography technique developed in the laboratory in order to observe its potentiality in this type of studies and the ability of these analysis in the characterization of the physical properties of such samples.


Assuntos
Animais , Osso e Ossos/anatomia & histologia , Osso e Ossos/diagnóstico por imagem , Coelhos/anatomia & histologia , Microtomografia por Raio-X , Densidade Óssea
20.
Phys Med ; 32(12): 1489-1494, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27866897

RESUMO

The present work investigates preliminary feasibility and characteristics of a new type of radiation therapy modality based on a single convergent beam of photons. The proposal consists of the design of a device capable of generating convergent X-ray beams useful for radiotherapy. The main goal is to achieve high concentrated dose delivery. The first step is an analytical approach in order to characterize the dosimetric performance of the hypothetical convergent photon beam. Then, the validated FLUKA Monte Carlo main code is used to perform complete radiation transport to account also for scattering effects. The proposed method for producing convergent X-rays is mainly based on the bremsstrahlung effect. Hence the operating principle of the proposed device is described in terms of bremsstrahlung production. The work is mainly devoted characterizing the effect on the bremsstrahlung yield due to accessories present in the device, like anode material and geometry, filtration and collimation systems among others. The results obtained for in-depth dose distributions, by means of analytical and stochastic approaches, confirm the presence of a high dose concentration around the irradiated target, as expected. Moreover, it is shown how this spot of high dose concentration depends upon the relevant physical properties of the produced convergent photon beam. In summary, the proposed design for producing single convergent X-rays attained satisfactory performance for achieving high dose concentration around small targets depending on beam spot size that may be used for some applications in radiotherapy, like radiosurgery.


Assuntos
Teleterapia por Radioisótopo/instrumentação , Estudos de Viabilidade , Método de Monte Carlo , Óptica e Fotônica , Fótons/uso terapêutico , Radiometria , Dosagem Radioterapêutica , Espalhamento de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...