1.
J Cardiovasc Electrophysiol ; 35(1): 155-161, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38010993

RESUMO

INTRODUCTION: The importance of atrio-ventricular synchrony pacing in sinus rhythm patients is known. To identify patients in whom leadless pacemakers are able to guarantee this atrio-ventricular synchrony, we explored correlations among echocardiographic measures of left atrial (LA) size and function (doppler parameter and strain) with A4 amplitude in patients implanted with new generation Micra-AV device. METHODS: After implantation with Micra-AV system, patients underwent device interrogation to evaluate AV synchrony based on the sensing of atrial mechanics and echocardiographic exam to assess LA morphology and LA function. RESULTS: In the 21 studied patients (14 males, 72 ± 13 years), the A4 wave amplitude values inversely correlated with LA antero-posterior diameter, LA volume, LA contraction strain and LA conduit strain, while they were positively related with LA reservoir strain. DISCUSSION: Our results indicate a statistically significant relationship between morphological echocardiographic LA parameters and atrial contraction signal (A4), detected by leadless pacemakers and used to synchronize ventricular pacing with the atrium. Instantaneous LA function assessment obtained with LA strain provides incremental information over morphological parameters. LA strain evaluates atrial myocardial deformation during the whole cardiac cycle. We found higher value of A4 in patients that have grater absolute value of LAsr, LAscd and LAsct, that are simple and measurable parameters of LA functional capacity. CONCLUSION: Preimplant echocardiographic evaluation of the atrial contractility may be useful in predicting adequate A4 sensing and consequently a good atrio-ventricular synchrony pacing. Echocardiography LA strain study seems promising in Micra-AV patient selection.


Assuntos
Átrios do Coração , Marca-Passo Artificial , Masculino , Humanos , Átrios do Coração/diagnóstico por imagem , Ventrículos do Coração , Ecocardiografia , Arritmias Cardíacas
2.
Heart Rhythm ; 20(2): 233-240, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-37283031

RESUMO

BACKGROUND: Elevated resting heart rate is a risk factor for cardiovascular events. OBJECTIVE: The purpose of this study was to investigate the clinical significance of nocturnal heart rate (nHR) and 24-hour mean heart rate (24h-HR) obtained by continuous remote monitoring (RM) of implantable devices. METHODS: We analyzed daily-sampled trends of nHR, 24h-HR, and physical activity in patients on ß-blocker therapy for chronic heart failure and with implantable cardioverter-defibrillators or cardiac resynchronization therapy defibrillators (CRT-Ds). Patients were grouped by average nHR and 24h-HR quartile during follow-up to estimate the respective incidence of nonarrhythmic death and device-treated ventricular tachycardia/fibrillation (VT/VF). RESULTS: The study cohort included 1330 patients (median age 69 years [interquartile range 61-77 years]; 41% [n = 550] with CRT-D; median follow-up 25 months [interquartile range 13-42 months]). Compared with patients in the lowest nHR quartile (≤57 beats/min) group, patients in the highest quartile group (>65 beats/min) had an increased risk of nonarrhythmic death (adjusted hazard ratio [AHR] 2.25; 95% confidence interval [CI] 1.13-4.50; P = .021) and VT/VF (AHR 1.98; 95% CI 1.40-2.79; P < .001) and were characterized by the lowest level of physical activity (P ≤ .0004 vs every other nHR quartiles). The highest 24h-HR quartile group (>75 beats/min) showed an increased risk of VT/VF (AHR 2.13; 95% CI 1.52-2.99; P < .001) and a weaker though significant association with nonarrhythmic mortality (AHR 1.80; 95% CI 1.00-3.22; P = .05) as compared with the lowest 24h-HR quartile group (≤65 beats/min). CONCLUSION: In remotely monitored patients with implantable cardioverter-defibrillator/CRT-D on ß-blocker therapy for heart failure, elevated heart rates (nHR >65 beats/min and 24h-HR >75 beats/min) were associated with increased mortality and VT/VF risk. nHR showed a stronger association than 24h-HR with worst prognosis and lowest physical activity.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Taquicardia Ventricular , Disfunção Ventricular Esquerda , Humanos , Pessoa de Meia-Idade , Idoso , Frequência Cardíaca , Prognóstico , Volume Sistólico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Arritmias Cardíacas/terapia , Fatores de Risco , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Terapia de Ressincronização Cardíaca/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Disfunção Ventricular Esquerda/complicações
3.
J Interv Card Electrophysiol ; 64(3): 607-619, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34709504

RESUMO

PURPOSE: The purpose of this study was to assess the available mortality risk stratification models for implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy defibrillator (CRT-D) patients. METHODS: We conducted a review of mortality risk stratification models and tested their ability to improve prediction of 1-year survival after implant in a database of patients who received a remotely controlled ICD/CRT-D device during routine care and included in the independent Home Monitoring Expert Alliance registry. RESULTS: We identified ten predicting models published in peer-reviewed journals between 2000 and 2021 (Parkash, PACE, MADIT, aCCI, CHA2DS2-VASc quartiles, CIDS, FADES, Sjoblom, AAACC, and MADIT-ICD non-arrhythmic mortality score) that could be tested in our database as based on common demographic, clinical, echocardiographic, electrocardiographic, and laboratory variables. Our cohort included 1,911 patients with left ventricular dysfunction (median age 71, 18.3% female) from sites not using any risk stratification score for systematic patient screening. Patients received an ICD (53.8%) or CRT-D (46.2%) between 2011 and 2017, after standard physician evaluation. There were 56 deaths within 1-year post-implant, with an all-cause mortality rate of 2.9% (95% confidence interval [CI], 2.3-3.8%). Four predicting models (Parkash, MADIT, AAACC, and MADIT-ICD non-arrhythmic mortality score) were significantly associated with increased risk of 1-year mortality with hazard ratios ranging from 3.75 (CI, 1.31-10.7) to 6.53 (CI 1.52-28.0, p ≤ 0.014 for all four). Positive predictive values of 1-year mortality were below 25% for all models. CONCLUSION: In our analysis, the models we tested conferred modest incremental predicting power to ordinary screening methods.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Feminino , Insuficiência Cardíaca/terapia , Humanos , Masculino , Medição de Risco , Fatores de Risco , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 32(9): 2528-2535, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34252991

RESUMO

INTRODUCTION: Factors influencing malignant arrhythmia onset are not fully understood. We explored the circadian periodicity of ventricular arrhythmias (VAs) in patients with implantable cardioverter and cardiac resynchronization defibrillators (ICD/CRT-D). METHODS: Time, morphology (monomorphic/polymorphic), and mode of termination (anti-tachycardia pacing [ATP] or shock) of VAs stored in a database of remote monitoring data were adjudicated. Episodes were grouped in six 4-h timeslots from 00:00 to 24:00. Circadian distributions and adjusted marginal odds ratios (ORs), with 95% confidence interval (CI), were analyzed using mixed-effect models and logit generalized estimating equations, respectively, to account for within-subject correlation of multiple episodes. RESULTS: Among 1303 VA episodes from 446 patients (63% ICD and 37% CRT-D), 120 (9%) self-extinguished, and 842 (65%) were terminated by ATP, 343 (26%) by shock. VAs clustered from 08:00 to 16:00 with 44% of episodes, as compared with 22% from 00:00 to 08:00 (p < .001) and 34% from 16:00 to 24:00 (p = .005). Episodes were more likely to be polymorphic at night with an adjusted marginal OR of 1.66 (CI, 1.15-2.40; p = .007) at 00:00-04:00 versus other timeslots. Episodes were less likely to be terminated by ATP in the 00:00-04:00 (success-to-failure ratio, 0.67; CI, 0.46-0.98; p = .039) and 08:00-12:00 (0.70; CI, 0.51-0.96; p = .02) timeslots, and most likely to be terminated by ATP between 12:00 and 16:00 (success-to-failure ratio 1.42; CI, 1.06-1.91; p = .02). CONCLUSION: VAs did not distribute uniformly over the 24 h, with a majority of episodes occurring from 08:00 to 16:00. Nocturnal episodes were more likely to be polymorphic. The efficacy of ATP depended on the time of delivery.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Taquicardia Ventricular , Arritmias Cardíacas , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Resultado do Tratamento
5.
ESC Heart Fail ; 6(2): 308-318, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30632306

RESUMO

AIMS: In the Multisensor Chronic Evaluation in Ambulatory Heart Failure Patients study, a novel algorithm for heart failure (HF) monitoring was implemented. The HeartLogic (Boston Scientific) index combines data from multiple implantable cardioverter defibrillator (ICD)-based sensors and has proved to be a sensitive and timely predictor of impending HF decompensation. The remote monitoring of HF patients by means of HeartLogic has never been described in clinical practice. We report post-implantation data collected from sensors, the combined index, and their association with clinical events during follow-up in a group of patients who received a HeartLogic-enabled device in clinical practice. METHODS AND RESULTS: Patients with ICD and cardiac resynchronization therapy ICD were remotely monitored. In December 2017, the HeartLogic feature was activated on the remote monitoring platform, and multiple ICD-based sensor data collected since device implantation were made available: HeartLogic index, heart rate, heart sounds, thoracic impedance, respiration, and activity. Their association with clinical events was retrospectively analysed. Data from 58 patients were analysed. During a mean follow-up of 5 ± 3 months, the HeartLogic index crossed the threshold value (set by default to 16) 24 times (over 24 person-years, 0.99 alerts/patient-year) in 16 patients. HeartLogic alerts preceded five HF hospitalizations and five unplanned in-office visits for HF. Symptoms or signs of HF were also reported at the time of five scheduled visits. The median early warning time and the time spent in alert were longer in the case of hospitalizations than in the case of minor events of clinical deterioration of HF. HeartLogic contributing sensors detected changes in heart sound amplitude (increased third sound and decreased first sound) in all cases of alerts. Patients with HeartLogic alerts during the observation period had higher New York Heart Association class (P = 0.025) and lower ejection fraction (P = 0.016) at the time of activation. CONCLUSIONS: Our retrospective analysis indicates that the HeartLogic algorithm might be useful to detect gradual worsening of HF and to stratify risk of HF decompensation.


Assuntos
Algoritmos , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca/fisiologia , Monitorização Fisiológica/instrumentação , Transdutores , Idoso , Desenho de Equipamento , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Hospitalização/tendências , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Tempo