Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Compr Rev Food Sci Food Saf ; 15(3): 619-632, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-33401822

RESUMO

Approximately 75% of all tomatoes in the United States are consumed as processed and 25% as fresh. One of the first steps during processing involves removal of the peel and, unfortunately, more than 25% of the fruits (as measured by total weight) can be lost due to overpeeling. Additionally, conventional peeling applications have a negative environmental impact. Given the great potential economic benefits, many scientists have conducted research to attempt optimizing or predicting peeling performance when processing tomatoes. The literature regarding tomato peelability is contradictory in many cases; and several topics have been subject to ample debate over the years. Divergent conclusions are probably not due to faulty investigations, but rather to the extreme variability found among tomato cultivars, the effect of growing seasons, and maybe even the effect of climatic conditions on the day of harvest or during transportation to the processing plants. This review provides an in-depth background needed for a better understanding of tomato physiology, maturation, and composition, as these could possibly influence the ease of peeling or "peelability." The research studies directly involved with peeling tomatoes and predicting peelability are discussed in this paper as well. Different peeling methods, peeling grading scales, and fruit tagging procedures are presented, as well as experiments evaluating the effect that fruit defects, maturity, growing conditions, and other factors can have on the ease of peeling. Novel approaches for peelability prediction by means of spectroscopic and magnetic resonance technology are also discussed in this review.

3.
Plant Foods Hum Nutr ; 70(2): 215-20, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25861767

RESUMO

The level of reducing sugars and asparagine in raw potatoes is critical for potato breeders and the food industry for production of commonly consumed food products including potato chips and French fries. Our objective was to evaluate the use of a portable infrared instrument for the rapid quantitation of major sugars and amino acids in raw potato tubers using single-bounce attenuated total reflectance (ATR) and dial path accessories as an alternative to time-consuming chromatographic techniques. Samples representing a total of 84 experimental and commercial potato varieties harvested in two consecutive growing seasons (2012 and 2013) were used in this study. Samples had wide ranges of sugars determined by HPLC-RID (non-detectable (ND)-7.7 mg glucose, ND-9.4 mg fructose and 0.4-5.4 mg sucrose per 1 g fresh weight), and asparagine and glutamine levels determined by GC-FID (0.7-2.9 mg and 0.3-1.7 mg per 1 g fresh weight). Infrared spectra collected from 64 varieties were used to create partial least squares regression (PLSR) calibration models that predicted the sugar and amino acid levels in an independent set of 16 validation potato varieties. Excellent linear correlations between infrared predicted and reference values were obtained. PLSR models had a high correlation coefficient of prediction (rPred >0.95) and residual predictive deviation (RPD) values ranging between 3.1 and 5.5. Overall, the results indicated that the models could be used to simultaneously predict sugars, free asparagine and glutamine levels in the raw tubers, significantly benefiting potato breeding, certain aspects of crop management, crop production and research.


Assuntos
Asparagina/análise , Glutamina/análise , Tubérculos/química , Solanum tuberosum/química , Aminoácidos/análise , Carboidratos/análise , Cromatografia Líquida de Alta Pressão , Modelos Lineares , Espectrofotometria Infravermelho/instrumentação , Espectroscopia de Infravermelho com Transformada de Fourier
4.
PLoS One ; 10(4): e0122627, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25915544

RESUMO

BACKGROUND AND OBJECTIVE: Clostridium difficile NAP1/ribotype 027 is associated with severe disease and high mortality rates. Our aim was to determine the prevalence of NAP1/ribotype 027 among C. difficile isolates in a tertiary care hospital, and review the main clinical data. METHODS: We included 106 stool samples from 106 patients. Samples were tested for A&B toxins and were cultured on CCFA agar. The genes tcdA, tcdB, tcdC, cdtA, and cdtB were amplified using PCR in clinical isolates. The tcdA 3'-end deletion analysis, PCR-ribotyping, and pulsed-field gel electrophoresis (PFGE) were also performed. Stool samples that were positive for culture were tested by the GeneXpert C. difficile assay. Clinical data were collected. RESULTS: Thirty-six patients tested positive for A&B toxins; and 22 patients had positive culture for C. difficile, 14 of which tested positive for the A&B toxins and all 22 patients tested positive by the GeneXpert C. difficile assay. Risk factors included an average hospital stay of 16.1 days prior to toxin detection, average antibiotic use for 16.2 days, and a median of 3 antibiotics used. The 30-day crude mortality rate was 8.4%. Six of the 22 patients died, and 3 of those deaths were directly attributed to C. difficile infection. The majority of isolates, 90.9% (20/22), carried genes tcdB, tcdA, cdtA, and cdtB; and these strains carried the corresponding downregulator gene tcdC, with an 18-bp deletion. PFGE was performed on 17 isolates, and one main pattern was observed. Analysis of the ribotyping data showed similar results. CONCLUSION: The above findings represent the clonal spread of C. difficile in our institution, which mainly includes the NAP1/027 strain. This is the first report of C. difficile ribotype NAP1/027 in Mexico.


Assuntos
Proteínas de Bactérias/isolamento & purificação , Toxinas Bacterianas/isolamento & purificação , Clostridioides difficile/genética , Enterocolite Pseudomembranosa/epidemiologia , Enterotoxinas/isolamento & purificação , Genes Bacterianos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Clostridioides difficile/classificação , Clostridioides difficile/isolamento & purificação , Clostridioides difficile/patogenicidade , Eletroforese em Gel de Campo Pulsado , Enterocolite Pseudomembranosa/tratamento farmacológico , Enterocolite Pseudomembranosa/microbiologia , Enterocolite Pseudomembranosa/mortalidade , Fezes/química , Fezes/microbiologia , Feminino , Humanos , Tempo de Internação , Masculino , México/epidemiologia , Pessoa de Meia-Idade , Ribotipagem , Fatores de Risco , Análise de Sobrevida , Centros de Atenção Terciária
5.
J Agric Food Chem ; 61(9): 2088-95, 2013 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-23373962

RESUMO

Two portable infrared sensors were evaluated for the rapid determination of quality parameters in processing tomatoes. A total of 370 hot-break juices were prepared from ∼40 processing tomato varieties grown in 5 California counties. The levels of sugars, acids, soluble solids, titratable acidity, and pH in these juices were determined using standard reference methods. Juices were processed, filtered, and directly applied to the FT-IR crystal (15-40 µL) to obtain spectra. Partial least-squares regression (PLSR) was used to generate correlation models, both calibration and validation. The PLS validation models showed good ability (Rval > 0.80; <10% SEP) in estimating the sugars, acids, and especially soluble solids in tomato for both the transmission DialPath portable system and benchtop unit using triple-bounce attenuated total reflectance (ATR). The IR portable unit may provide the tomato processing industry with an efficient method for in-plant, high throughput quantification of quality parameters in tomatoes.


Assuntos
Manipulação de Alimentos/métodos , Qualidade dos Alimentos , Solanum lycopersicum/química , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Ácidos/análise , California , Carboidratos/análise , Frutas/química , Concentração de Íons de Hidrogênio , Análise dos Mínimos Quadrados , Análise Multivariada , Espectroscopia de Infravermelho com Transformada de Fourier/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...