RESUMO
INTRODUCTION: The objectives of this study are to experimentally evaluate the haemostatic effects of two organic substances, a membrane of chitosan and a collagen sponge coated with thrombin and human fibrinogen (TachoSil®), in sealing 7-0 needle stitches holes on the femoral arteries of rats as well as to evaluate local histological reactions. METHODS: Twenty-four rats were included, and four holes were made in each common femoral artery. In the control group, haemostasis was achieved only by compression with gauze sponge; and in the two other groups, haemostasis was achieved with application of one of these two substances. RESULTS: Membrane of chitosan and TachoSil® showed a power to reduce the time to achieve haemostasis compared with the control group (P=0.001), and the haemostatic effects of these two substances were comparable. There was lower blood loss in the groups where these two substances were used when compared with the control group, but no difference was found comparing the two substances. CONCLUSION: The use of these sealants did not promote more adhesion or local histological reactions when compared to the control group. Since chitosan is easy to find in nature, has a positive effect to promote haemostasis, and did not bring considerable local reactions, it might be used as a sealant in cardiovascular surgery.
Assuntos
Quitosana , Hemostáticos , Animais , Quitosana/farmacologia , Colágeno/farmacologia , Colágeno/uso terapêutico , Combinação de Medicamentos , Fibrinogênio/farmacologia , Fibrinogênio/uso terapêutico , Hemostasia Cirúrgica , Hemostáticos/farmacologia , Hemostáticos/uso terapêutico , Humanos , Ratos , Trombina/farmacologiaRESUMO
ABSTRACT Introduction: The objectives of this study are to experimentally evaluate the haemostatic effects of two organic substances, a membrane of chitosan and a collagen sponge coated with thrombin and human fibrinogen (TachoSil®), in sealing 7-0 needle stitches holes on the femoral arteries of rats as well as to evaluate local histological reactions. Methods: Twenty-four rats were included, and four holes were made in each common femoral artery. In the control group, haemostasis was achieved only by compression with gauze sponge; and in the two other groups, haemostasis was achieved with application of one of these two substances. Results: Membrane of chitosan and TachoSil® showed a power to reduce the time to achieve haemostasis compared with the control group (P=0.001), and the haemostatic effects of these two substances were comparable. There was lower blood loss in the groups where these two substances were used when compared with the control group, but no difference was found comparing the two substances. Conclusion: The use of these sealants did not promote more adhesion or local histological reactions when compared to the control group. Since chitosan is easy to find in nature, has a positive effect to promote haemostasis, and did not bring considerable local reactions, it might be used as a sealant in cardiovascular surgery.