STUDY OBJECTIVE: To test the hypothesis that the jaw closure using a pneumatic actuator device affect airway collapsibility and resistance during propofol anesthesia. DESIGN: Prospective, randomized study. SETTING: University-affiliated hospital. PATIENTS: Six male subjects were included in the present study. INTERVENTION: We used pressure-flow relationships to evaluate critical closing pressure (PCRIT) and upper airway resistance in different conditions of body and head position. Anesthesia was induced and maintained with a propofol infusion, targeting a constant blood concentration of 1.5 to 2.0µg/mL to establish an adequate depth of anesthesia, with patients breathing spontaneously through a nasal mask. An air-inflatable pneumatic actuator was used to achieve jaw closure. Nasal mask pressure was intermittently reduced to evaluate upper airway collapsibility (passive PCRIT) and upstream resistance under 4 different conditions: (1) neutral occlusion at 0-cm head elevation (baseline), (2) jaw closure at 0-cm head elevation, (3) neutral occlusion at 6-cm head elevation, and (4) jaw closure at 6-cm head elevation. PCRIT and upstream resistance under each condition were compared using 1-way analysis of variance. P<.05 was considered significant. MEASUREMENTS: The pressure and inspiratory flow at the subjects' nose mask were recorded. Polysomonographic parameters (electroencephalograms, electrooculograms, submental electromyograms, and plethysmogram) were also recorded. MAIN RESULTS: The combination of 6-cm head elevation with jaw closure using the pneumatic actuator decreased upper airway collapsibility (PCRIT≈-3.0 cm H2O) compared to the baseline position (PCRIT≈-1.2 cm H2O; P=.0003). CONCLUSION: We demonstrated that jaw closure using an air-inflatable pneumatic actuator device can produce substantial decreases in upper airway collapsibility and maintain upper airway patency during propofol anesthesia.


Assuntos
Manuseio das Vias Aéreas/métodos , Obstrução das Vias Respiratórias/prevenção & controle , Anestésicos Intravenosos/administração & dosagem , Propofol/administração & dosagem , Robótica/instrumentação , Adulto , Resistência das Vias Respiratórias , Anestesia Intravenosa/métodos , Ar Comprimido , Movimentos da Cabeça/fisiologia , Humanos , Arcada Osseodentária/fisiologia , Masculino , Projetos Piloto , Robótica/métodos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...