Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
1.
Tex Heart Inst J ; 51(1)2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38686682

RESUMO

Quadricuspid aortic valve is a rare congenital cardiac anomaly with an incidence of 0.008% to 0.043%. Its clinical course varies depending on cusp anatomy, function, and associated cardiac malformations. It frequently progresses to aortic valve regurgitation that may require surgical valve replacement. Detection has shifted from incidental discovery during autopsies or cardiac surgeries in the early 20th century to various cardiac imaging methods in recent decades. In addition to contributing to the literature, this report supports the use of transesophageal echocardiography more liberally to detect aortic valve abnormalities. The case presents a 48-year-old female patient with an incidentally discovered quadricuspid aortic valve.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Ecocardiografia Transesofagiana , Cardiopatias Congênitas , Achados Incidentais , Humanos , Feminino , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Pessoa de Meia-Idade , Ecocardiografia Transesofagiana/métodos , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/etiologia , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/diagnóstico por imagem , Valor Preditivo dos Testes , Implante de Prótese de Valva Cardíaca , Ecocardiografia Doppler em Cores
2.
J Surg Case Rep ; 2024(4): rjae211, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38605700

RESUMO

Lung transplant recipients are at higher risk of developing COVID-19 infection compared to other solid organ transplants. The risk further increases in the unvaccinated patients. We present a case of a 43-year-old male who underwent bilateral sequential lung transplantation for pulmonary alveolar microlithiasis (PAM) and had an uneventful recovery. However, two years post-transplantation, the patient developed chronic lung allograft dysfunction (CLAD) with bronchiolitis obliterans syndrome and two episodes of COVID-19 infection. During the second episode of COVID-19 infection, the patient developed sepsis and multi-organ dysfunction ultimately resulting in death. Our case report highlights the increased susceptibility of PAM patients' post-lung transplant to COVID-19 infection. Continuous follow-up of PAM patients' post-lung transplantation is necessary to prevent unfavorable outcomes.

3.
Artif Organs ; 48(5): 559-566, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38400624

RESUMO

BACKGOUND: Infections of the left ventricular assist device (LVAD) driveline are a dreaded complication that results in high mortality and morbidity. METHOD: We retrospectively reviewed five consecutive patients with severe continuous-flow LVAD (HVAD, Heartmate 2, and Heartmate 3) driveline infection. These infections, which developed on an average of 960.4 ± 843.9 days after LVAD placement, were refractory to systemic antibiotics and local wound care. All were treated with extensive surgical debridement, local installation of absorbable antibiotic-loaded calcium sulfate beads (vancomycin and tobramycin), primary wound closure, and 6 weeks of systemic antibiotics after surgery. RESULTS: Four patients had resolution of DLI, and one had a recurrent infection at another part of the driveline 7 months after the complete resolution of the previous site. This patient was successfully treated with debridement and bead placements. Three patients still have their LVADs, while two received orthotopic heart transplants. At the time of the transplant, there was no evidence of gross infection of the LVAD drivelines or pumps. At the average follow-up time of 425.8 ± 151 days, no patients have an active infection. CONCLUSION: Treatment of LVAD driveline infection with absorbable antibiotic beads with primary wound closure is a viable option and merits further investigation.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Infecções Relacionadas à Prótese , Humanos , Antibacterianos/uso terapêutico , Estudos Retrospectivos , Coração Auxiliar/efeitos adversos , Insuficiência Cardíaca/cirurgia , Vancomicina , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/cirurgia
4.
Front Cardiovasc Med ; 11: 1345540, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38357514

RESUMO

Background: The pulsed-electron avalanche knife (PEAK) PlasmaBlade provides an atraumatic, scalpel-like cutting precision and electrocautery-like hemostasis. PlasmaBlade operates near body temperature, and its long, thin, and malleable tip can overcome the limitations of a surgical knife. In this study, we aimed to evaluate our clinical experience and histopathological outcomes of septal myectomy using PlasmaBlade. Methods: Electronic medical records were reviewed for preoperative, operative, and follow-up data of the patients who underwent septal myectomy using PEAK PlasmaBlade at our institute between January 2019 and December 2022. Histopathology of the myectomy specimens was reviewed for the depth of muscle necrosis and compared with the left atrial appendage (LAA) specimen. Results: Twenty-nine patients underwent septal myectomy using the PEAK PlasmaBlade. No mortality was reported. The mean age was 60.6 ± 12.5 years, and 58.6% of patients were male. Peak left ventricular outflow tract (LVOT) gradients were 40.5 ± 34.9 mmHg at rest and 56.5 ± 34.9 mmHg after provocation. Concomitant procedures performed were LAA ligation in 20 (69.0%), aortic valve replacement in 5 (17.2%), and coronary artery bypass grafting in 3 (10.3%) patients. Postoperative complications were complete heart block in one (3.4%) and ventricular septal defect in two (6.9%) patients. Both the ventricular septal defects were identified intraoperatively and repaired. Histopathology of myectomy specimens demonstrated cautery artifact limited to <50 µm depth compared to >1,000 µm with conventional electrocautery. At a mean follow-up of 8.4 ± 10.3 months, the mean LVOT gradient was 4.4 ± 5.8 mmHg at rest and 9.5 ± 3.3 mmHg after provocation. All patients were alive and in New York Heart Association class I/II. No patient developed complications or required reintervention or reoperation. Conclusion: Adequate septal myectomy can be precisely and safely performed using the PEAK PlasmaBlade with minimal collateral damage.

5.
BMC Rheumatol ; 8(1): 9, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38424614

RESUMO

BACKGROUND: Impella is an advanced ventricular assist device frequently used as a bridge to heart transplantation. The association of Impella with increased rates of gout flares has not been studied. Our primary aim is to determine the rates of gout flares in patients on Impella support. METHODOLOGY: A retrospective study was conducted between January 2017 and September 2022 involving all patients who underwent heart transplantation. The cohort was divided into two groups based on Impella support for statistical analysis. In patients receiving Impella support, outcome measures were compared based on the development of gout flares. 1:1 nearest neighbor propensity match, as well as inverse propensity of treatment weighted analyses, were performed to explore the causal relationship between impella use and gout flare in our study population. RESULTS: Our analysis included 213 patients, among which 42 (19.71%) patients were supported by Impella. Impella and non-Impella groups had similar age, race, and BMI, but more males were in the Impella group. Gout and chronic kidney disease were more prevalent in Impella-supported patients, while coronary artery disease was less common. The prevalence of gout flare was significantly higher in Impella patients (30.9% vs. 5.3%). 42 Impella-supported patients were matched with 42 patients from the non-impella group upon performing a 1:1 propensity matching. Impella-supported patients were noted to have a significantly higher risk of gout flare (30.9% vs. 7.1%, SMD = 0.636), despite no significant difference in pre-existing gout history and use of anti-gout medications. Impella use was associated with a significantly increased risk of gout flare in unadjusted (OR 8.07), propensity-matched (OR 5.83), and the inverse propensity of treatment-weighted analysis (OR 4.21). CONCLUSION: Our study is the first to identify the potential association between Impella support and increased rates of gout flares in hospitalized patients. Future studies are required to confirm this association and further elucidate the biological pathways. It is imperative to consider introducing appropriate measures to prevent and promptly manage gout flares in Impella-supported patients.

6.
Can J Anaesth ; 71(3): 422-430, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38286981

RESUMO

PURPOSE: Obtaining an objective, reproducible, and accurate assessment of volume status is one of the more difficult tasks in the perioperative arena. Since its advent in 2020, the Venous Excess Ultrasound (VExUS) score has gained popularity in the minimally invasive assessment of venous congestion. The VExUS exam has been well described as an additional series of images (hepatic vein, portal vein, and intrarenal vein) obtained with a phased-array probe during a transthoracic echocardiogram. Nevertheless, there are no descriptions of comprehensive VExUS exams performed using transesophageal echocardiography (TEE)-a modality that is routinely employed in patients undergoing cardiac surgery. CLINICAL FEATURES: We describe techniques to acquire and interpret a comprehensive TEE-supported VexUS exam, which may be used to optimize the perioperative care of cardiac surgical patients. CONCLUSION: Given the risks of fluid overload in critically ill cardiac surgery patients, TEE-supported VExUS examination may be a way to reduce morbidity in this population.


RéSUMé: OBJECTIF: L'obtention d'une évaluation objective, reproductible et précise du statut volémique est l'une des tâches les plus difficiles dans l'arène périopératoire. Depuis son introduction en 2020, le score VExUS (pour Venous Excess Ultrasound, soit échographie de l'excès veineux) a gagné en popularité dans l'évaluation minimalement invasive de la congestion veineuse. L'examen échographique VExUS a été bien décrit en tant que série supplémentaire d'images (veine hépatique, veine porte et veine intrarénale) obtenues à l'aide d'une sonde type « phased-array ¼ lors d'un échocardiogramme transthoracique. Néanmoins, il n'existe aucune description d'examens VExUS complets réalisés à l'aide d'une sonde d'ETO (échocardiographie transœsophagienne), une modalité couramment utilisée chez les patient·es bénéficiant d'une chirurgie cardiaque. CARACTéRISTIQUES CLINIQUES: Nous décrivons des techniques permettant d'acquérir et d'interpréter un examen VexUS complet par ETO, qui peut être utilisé pour optimiser les soins périopératoires de la patientèle en chirurgie cardiaque. CONCLUSION: Compte tenu des risques de surcharge hydrique chez la patientèle gravement malade en chirurgie cardiaque, l'examen VExUS basé sur l'ETO peut être un moyen de réduire la morbidité dans cette population.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ecocardiografia Transesofagiana , Humanos , Ecocardiografia Transesofagiana/métodos , Coração , Assistência Perioperatória/métodos , Veias
8.
Sci Rep ; 13(1): 19671, 2023 11 11.
Artigo em Inglês | MEDLINE | ID: mdl-37952046

RESUMO

Impaired kidney function is often associated with acute decompensation of chronic heart failure and portends a poor prognosis. Unfortunately, current data have demonstrated worse survival in patients with acute kidney injury than in patients with chronic kidney disease during durable LVAD placement as bridge therapy. Furthermore, end-stage heart failure patients undergoing combined heart-kidney transplantation have poorer short- and long-term survival than heart transplants alone. We evaluated the kidney function recovery in our heart failure population awaiting heart transplantation at our institution, supported by temporary Mechanical Circulatory Support (tMCS) with Impella 5.5. The protocol (#22004000) was approved by the Mayo Clinic institutional review board, after which we performed a retrospective review of all patients with acute on chronic heart failure and kidney disease in patients considered for only heart and kidney combined organ transplant and supported by tMCS between January 2020 and February 2021. Hemodynamic and kidney function trends were recorded and analyzed before and after tMCS placement and transplantation. After placement of tMCS, we observed a trend towards improvement in creatinine, Fick cardiac index, mixed venous saturation, and glomerular filtration rate (GFR), which persisted through transplantation and discharge. The average duration of support with tMCS was 16.5 days before organ transplantation. The median pre-tMCS creatinine was 2.1 mg/dL (IQR 1.75-2.3). Median hematocrit at the time of tMCS placement was 32% (IQR 32-34), and the median estimated glomerular filtration rate was 34 mL/min/BSA (34-40). The median GFR improved to 44 mL/min/BSA (IQR 45-51), and serum creatinine improved to 1.5 mg/dL (1.5-1.8) after tMCS. Median discharge creatinine was 1.1 mg/dL (1.19-1.25) with a GFR of 72 (65-74). None of these six patients supported with tMCS required renal replacement therapy after heart transplantation. Early adoption of Impella 5.5 in this patient population resulted in renal recovery without needing renal replacement therapies or dual organ transplantation and should be further evaluated.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Insuficiência Renal Crônica , Humanos , Creatinina , Insuficiência Cardíaca/cirurgia , Rim/fisiologia , Insuficiência Renal Crônica/cirurgia
9.
Front Med (Lausanne) ; 10: 1240426, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38020180

RESUMO

Background: The COVID-19 pandemic intensified the use of scarce resources, including extracorporeal membrane oxygenation (ECMO) and mechanical ventilation (MV). The combinatorial features of the immune system may be considered to estimate such needs and facilitate continuous open-ended knowledge discovery. Materials and methods: Computer-generated distinct data patterns derived from 283 white blood cell counts collected within five days after hospitalization from 97 COVID-19 patients were used to predict patient's use of hospital resources. Results: Alone, data on separate cell types-such as neutrophils-did not identify patients that required MV/ECMO. However, when structured as multicellular indicators, distinct data patterns displayed by such markers separated patients later needing or not needing MV/ECMO. Patients that eventually required MV/ECMO also revealed increased percentages of neutrophils and decreased percentages of lymphocytes on admission. Discussion/conclusion: Future use of limited hospital resources may be predicted when combinations of available blood leukocyte-related data are analyzed. New methods could also identify, upon admission, a subset of COVID-19 patients that reveal inflammation. Presented by individuals not previously exposed to MV/ECMO, this inflammation differs from the well-described inflammation induced after exposure to such resources. If shown to be reproducible in other clinical syndromes and populations, it is suggested that the analysis of immunological combinations may inform more and/or uncover novel information even in the absence of pre-established questions.

10.
Front Cardiovasc Med ; 10: 1237772, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37790593

RESUMO

The incidence of post-acute myocardial infarction ventricular septal rupture (post-AMI VSR) has decreased; however, mortality after surgical repair of post-AMI VSR remains high. Patients who are not surgical candidates can be managed by heart transplant with a good outcome. A heart transplant in a patient after successful repair of VSR has never been reported. We report a patient who had persistent right heart failure after the successful repair of VSR and underwent a heart transplant with a good outcome.

11.
Braz J Cardiovasc Surg ; 38(6): e20230041, 2023 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-37801652

RESUMO

Chylothorax after an orthotopic heart transplant is a rare but potentially detrimental occurrence. This is the first reported case of bilateral chylothorax complicating a heart-kidney transplant patient. No universally accepted protocol exists for the management of chylothorax in general population, let alone the immunocompromised transplant patient. This case presents unique challenges to the management of postoperative chylothorax given heart-kidney transplant's effect on the patient's volume status and immunocompromised state. We make the argument for aggressive treatment of chylothorax in an immunocompromised heart-kidney transplant patient to limit complications in a patient population predisposed to infection.


Assuntos
Quilotórax , Transplante de Coração , Transplante de Rim , Transplantes , Humanos , Transplante de Rim/efeitos adversos , Quilotórax/diagnóstico por imagem , Quilotórax/etiologia , Quilotórax/cirurgia , Transplante de Coração/efeitos adversos , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/cirurgia
12.
Indian J Thorac Cardiovasc Surg ; 39(Suppl 1): 25-46, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37525710

RESUMO

Cardiogenic shock is a state of low cardiac output that is associated with significant morbidity and mortality. A considerable proportion of patients with cardiogenic shock respond poorly to medical management and require acute mechanical circulatory support (AMCS) devices to improve tissue perfusion as well as to support the heart. In the last two decades, many new AMCS devices have been introduced to support the right, left, and both ventricles. All these devices vary in terms of the support they provide to the body and heart, mechanism of functioning, method of insertion, and adverse events. In this review, we compare and contrast the available percutaneous and surgically placed AMCS devices used in cardiogenic shock and discuss the associated clinical and hemodynamic data to make a conscious decision about choosing a device.

13.
J Geriatr Cardiol ; 20(5): 319-329, 2023 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-37397862

RESUMO

BACKGROUND: Optimizing patients with advanced heart failure before orthotopic heart transplantation (OHT), especially in patients greater than 50 years old, is imperative to achieving successful post-transplant outcomes. Complications are well-described for patients bridged to transplant (BTT) with durable left ventricular assist device (LVAD) support. Given the lack of data available in older recipients after the recent increase in mechanical support use, we felt it crucial to report our center's one-year outcomes in older recipients after heart transplantation with percutaneously placed Impella 5.5 as a BTT. METHODS: Forty-nine OHT patients were supported with the Impella 5.5 intended as a bridge between December 2019 and October 2022 at Mayo Clinic in Florida. Data were extracted from the electronic health record at baseline and during their transplant episode of care after Institutional Review Boards approval as exempt for retrospective data collection. RESULTS: Thirty-eight patients aged 50 or older were supported with Impella 5.5 as BTT. Ten patients underwent heart and kidney transplantation within this cohort. The median age at OHT was 63 (58-68) years, with 32 male (84%) and six female patients (16%). Etiology was divided into ischemic (63%) and non-ischemic cardiomyopathy (37%). The baseline median ejection fraction was 19% (15-24). Most patients were in blood group O (60%), and 50% were diabetic. The average duration of support was 27 days (range 6-94). The median duration of follow-up is 488 days (185-693). For patients that have reached the 1-year follow-up timeframe (22 of 38, 58%), the 1-year post-transplant survival is 95%. CONCLUSION: Our single-center data provides awareness for using the Impella 5.5 percutaneously placed axillary support device in older heart failure patients in cardiogenic shock as a bridge to transplantation. One-year survival outcomes after heart transplantation are excellent despite the older recipient's age and prolonged pre-transplant support.

14.
Crit Care Med ; 51(11): 1461-1468, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37378470

RESUMO

OBJECTIVES: To evaluate the 30-day postoperative mortality and palliative care consultations in patients that underwent surgical procedures in the United States before and after Medicare Access and Children's Health Insurance Program Reauthorization Act (MACRA) implementation. DESIGN: Retrospective, Observational cohort study. SETTING: Secondary data were collected from the U.S. National Inpatient Sample, the largest hospital database in the country. The time span was from 2011 to 2019. PATIENTS: Adult patients that electively underwent 1 of 19 major procedures. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The primary outcome was cumulative postoperative mortality in two study cohorts. The secondary outcome was palliative care use. We identified 4,900,451 patients and categorized them into two study cohorts: PreM: 2011-2014 ( n = 2,103,836) and PostM: 2016-2019 ( n = 2,796,615). Regression discontinuity estimates and multivariate analysis were used. Across all procedures, 149,372 patients (7.1%) and 156,610 patients (5%) died within 30 days of their index procedures in the PreM and PostM cohorts, respectively. There was no statistically significant increase in mortality rates around postoperative day (POD) 30 (POD 26-30 vs 31-35) for both cohorts. More patients had inpatient palliative consultations during POD 31-60 compared with POD 1-30 in PreM (8,533 of 2,081,207 patients [0.4%] vs 1,118 of 22,629 patients [4.9%]) and PostM (18,915 of 2,791,712 patients [0.7%] vs 417 of 4,903 patients [8.5%]). Patients were more likely to receive palliative care consultations during POD 31-60 compared with POD 1-30 in both the PreM (odds ratio [OR] 5.31; 95% CI, 2.22-8.68; p < 0.001) and the PostM (OR 7.84; 95% CI, 4.83-9.10; p < 0.001) cohorts. CONCLUSIONS: We did not observe an increase in postoperative mortality after POD 30 before or after MACRA implementation. However, palliative care use markedly increased after POD 30. These findings should be considered hypothesis-generating because of several confounders.


Assuntos
Children's Health Insurance Program , Cuidados Paliativos , Idoso , Adulto , Criança , Humanos , Estados Unidos , Medicare , Estudos Retrospectivos , Políticas , Encaminhamento e Consulta , Cuidados Críticos
15.
ESC Heart Fail ; 10(4): 2298-2306, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37137732

RESUMO

AIMS: We sought to investigate the outcomes of heart transplant patients supported with Impella 5.5 temporary mechanical circulatory support. METHODS AND RESULTS: Patient demographics, perioperative data, hospital timeline, and haemodynamic parameters were followed during initial admission, Impella support, and post-transplant period. Vasoactive-inotropic score, primary graft failure, and complications were recorded. Between March 2020 and March 2021, 16 advanced heart failure patients underwent Impella 5.5 temporary left ventricular assist device support through axillary approach. Subsequently, all these patients had heart transplantation. All patients were either ambulatory or chair bound during their temporary mechanical circulatory support until heart transplantation. Patients were kept on Impella support median of 19 days (3-31) with the median lactate dehydrogenase level of 220 (149-430). All Impella devices were removed during heart transplantation. During Impella support, patients had improved renal function with median creatinine serum level of 1.55 mg/dL decreased to 1.25 (P = 0.007), pulmonary artery pulsatility index scores increased from 2.56 (0.86-10) to 4.2 (1.3-10) (P = 0.048), and right ventricular function improved (P = 0.003). Patients maintained improved renal function and favourable haemodynamics after their heart transplantation as well. All patients survived without any significant morbidity after their heart transplantation. CONCLUSIONS: Impella 5.5 temporary left ventricular assist device optimizes care of heart transplant recipients providing superior haemodynamic support, mobility, improved renal function, pulmonary haemodynamics, and right ventricular function. Utilizing Impella 5.5 as a direct bridging strategy to heart transplantation resulted in excellent outcomes.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/etiologia
16.
Mayo Clin Proc Innov Qual Outcomes ; 7(2): 93-98, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36644594

RESUMO

Coronavirus disease 2019 (COVID-19) pandemic has led to considerable morbidity and mortality across the world. Lung transplant is a viable option for a few with COVID-19-related lung disease. Whom and when to transplant has been the major question impacting the transplant community given the novelty of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). We describe a pitfall of presumed prolonged shedding of SARS-CoV-2 in a patient with COVID-19 associated acute respiratory distress syndrome leading to COVID-19 pneumonia after lung transplant. This raises concerns that replication-competent SARS-CoV-2 virus can persist for months post-infection and can lead to re-infection of grafts in the future.

17.
Ann Thorac Surg ; 116(5): 1071-1078, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36404446

RESUMO

BACKGROUND: Recovering lungs with pulmonary edema due to abnormal kidney function is considered one of the expanded selection criteria for lung transplant. The aim of this study is to assess lung transplant recipients' survival from donors with abnormal kidney function and to determine differences in lung recovery rates from donors with and donors without abnormal kidney function. METHODS: We reviewed the United Network for Organ Sharing registry for first-time adult lung transplant donors and recipients from June 2005 to March 2017. Donor kidney function was categorized into three groups based on estimated glomerular filtration rate: group I, greater than 60 mL/min; group II, 15 to 59 mL/min; and group III, less than 15 mL/min. Recipient survival was stratified based on estimated glomerular filtration rate using Kaplan-Meier. A multivariate Cox Regression model with known risk factors that affect survival was used to compare survival among groups. Comparison of lung recovery among the three groups was also performed. RESULTS: Lung recovery rates were 29.7% (15,670 of 52,747), 19.4% (3879 of 20,040), and 18.1% (704 of 3898) for groups I, II, and III, respectively. The 1-, 3-, and 5-year recipient survival rates were 86.2%, 69.2%, and 55.7% for group I; 84.9%, 66.9%, and 53.8% for group II; and 85.5%, 65.3%, and 50.3% for group III, respectively (adjusted P = .25; multivariate Cox regression method). When group I was used as reference, the adjusted hazard ratio for group II was 1.04 (95% CI, 0.98-1.10) and for group III, it was 1.08 (95% CI, 0.96-1.23), after adjusting with the multivariate Cox regression model. CONCLUSIONS: There was no significant difference in lung recipient survival. The lung recovery rate from donors with abnormal kidney function was lower compared with that of donors with normal kidney function.

18.
Rev. bras. cir. cardiovasc ; 38(6): e20230041, 2023. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1514977

RESUMO

ABSTRACT Chylothorax after an orthotopic heart transplant is a rare but potentially detrimental occurrence. This is the first reported case of bilateral chylothorax complicating a heart-kidney transplant patient. No universally accepted protocol exists for the management of chylothorax in general population, let alone the immunocompromised transplant patient. This case presents unique challenges to the management of postoperative chylothorax given heart-kidney transplant's effect on the patient's volume status and immunocompromised state. We make the argument for aggressive treatment of chylothorax in an immunocompromised heart-kidney transplant patient to limit complications in a patient population predisposed to infection.

19.
JTCVS Open ; 16: 1029-1037, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38204698

RESUMO

Background: The utilization of extracorporeal life support (ECLS) for intraoperative support during lung transplantation has increased over the past decade. Although veno-arterial extracorporeal membrane oxygenation (VA-ECMO) has recently emerged as the preferred modality over cardiopulmonary bypass (CPB), many centers continue to use both forms of ECLS during lung transplantation. Our novel hybrid VA-ECMO/CPB circuit allows for seamless transition from VA-ECMO to CPB at a significant cost savings compared to a standalone VA-ECMO circuit. This study describes our initial experience and outcomes in the first 100 bilateral lung transplantations using this novel hybrid VA-ECMO/CPB circuit. Methods: Medical records from September 2017 to May 2021 of the first 100 consecutive patients undergoing bilateral lung transplantation with intraoperative hybrid VA-ECMO support were examined retrospectively. We excluded patients with single lung transplants, retransplantations, preoperative ECLS bridging, and veno-venous (VV) ECMO and those supported with CPB only. Perioperative recipient, anesthetic, perfusion variables, and outcomes were assessed. Results: Of the 100 patients supported with VA-ECMO, 19 were converted intraoperatively to CPB. Right ventricular dysfunction was seen in 37% of patients, and the median mean pulmonary artery pressure was 28 mm Hg. No oxygenator clotting was observed with a median heparin dose of 13,000 units in the VA-ECMO group. Primary graft dysfunction grade 3 at 72 hours was observed in 10.1% of all patients and observed 1-year mortality was 4%. Conclusions: The use of a hybrid VA-ECMO/CPB circuit in our institution allows for rapid conversion to CPB with acceptable outcomes across a diverse recipient group at a significantly reduced cost compared to standalone VA-ECMO circuits.

20.
Artigo em Inglês | MEDLINE | ID: mdl-36409034

RESUMO

Haemorrhagic pericardial cysts are rare and may be complicated by encasement of the heart, right heart failure and, rarely, cardiac cirrhosis. Surgical management of complicated cysts is challenging and has poor outcomes. We report a case of successful surgical management of a complicated pericardial cyst presenting with cardiac cirrhosis and the challenges associated with this condition.


Assuntos
Insuficiência Cardíaca , Cisto Mediastínico , Doenças Vasculares , Humanos , Cisto Mediastínico/complicações , Cisto Mediastínico/diagnóstico por imagem , Cisto Mediastínico/cirurgia , Cirrose Hepática/complicações , Cirrose Hepática/cirurgia , Pericárdio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...