Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 155
Filtrar
1.
Curr Cardiol Rep ; 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38526749

RESUMO

PURPOSE OF REVIEW: Although rare, the development of mechanical complications following an acute myocardial infarction is associated with a high morbidity and mortality. Here, we review the clinical features, diagnostic strategy, and treatment options for each of the mechanical complications, with a focus on the role of echocardiography. RECENT FINDINGS: The growth of percutaneous structural interventions worldwide has given rise to new non-surgical options for management of mechanical complications. As such, select patients may benefit from a novel use of these established treatment methods. A thorough understanding of the two-dimensional, three-dimensional, color Doppler, and spectral Doppler findings for each mechanical complication is essential in recognizing major causes of hemodynamic decompensation after an acute myocardial infarction. Thereafter, echocardiography can aid in the selection and maintenance of mechanical circulatory support and potentially facilitate the use of a percutaneous intervention.

3.
J Pharm Pract ; 37(2): 509-512, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36803045

RESUMO

Ultrasound enhancing agents (UEAs) are medications that enable clear visualization of ultrasound images. While large studies have demonstrated the safety of these agents, case reports of life-threatening reactions temporally associated with their use have been published and reported to the Food and Drug Administration. Current literature describes the most serious adverse reactions due to UEAs to be allergic in nature; however, embolic phenomena may play a role as well. Here, we report a case of unexplained cardiac arrest following the administration of sulfur hexafluoride (Lumason®) in an adult inpatient undergoing echocardiography where resuscitative efforts were ultimately unsuccessful, and review possible mechanisms of cardiac arrest based on prior published literature.


Assuntos
Parada Cardíaca , Hexafluoreto de Enxofre , Adulto , Humanos , Hexafluoreto de Enxofre/efeitos adversos , Meios de Contraste/efeitos adversos , Ultrassonografia/métodos , Administração Intravenosa , Parada Cardíaca/induzido quimicamente
9.
Am J Cardiol ; 203: 92-97, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37487407

RESUMO

Discrepancy between computed tomography (CT) and transthoracic echocardiography (TTE) regarding pericardial effusion (PEff) size is common, but there is limited data regarding the correlation between these 2 imaging methods. The aim of this study is to examine the real-world concordance of observed PEff size between CT and TTE. We performed a retrospective analysis of all imaging reports available from 2013 to 2019 and identified patients with a PEff who underwent both a chest CT and TTE within a 24-hour period. We evaluated the agreement between CT and TTE in assessing PEff size. Of 1,118 patients included in the study, mean age was 66 (±17 years) and 54% were female. The median time interval between the 2 studies was 9.4 hours (interquartile range 3.5 to 16.6). Patients within a half-grade or full-grade of agreement were 71.9% and 97.2%, respectively. The mean difference in grade of agreement (TTE minus CT) between the 2 imaging methods was -0.1 (±0.6, p <0.0001). CT was more likely to report a higher grade (i.e. larger PEff size) when compared with TTE (261 patients vs 157 patients, p <0.001). The weighted kappa was 0.73 (95% confidence interval 0.69 to 0.76). After excluding patients with trace/no effusion, 42.3% and 94.1% of patients' studies were within a half-grade or full-grade of agreement, respectively. Of the 18 patients who had large discrepancies, 9 patients had loculated effusions, 2 patients had large pleural effusions, and 6 patients had suboptimal TTEs images. In conclusion, TTE and CT showed relatively strong agreement in estimation of PEff size, with CT sizes larger than TTE, on average. Large discrepancies in size may be related to reduced image quality, large pleural effusions, and loculated PEff.


Assuntos
Derrame Pericárdico , Derrame Pleural , Humanos , Feminino , Idoso , Masculino , Derrame Pericárdico/diagnóstico por imagem , Estudos Retrospectivos , Ecocardiografia/métodos , Tomografia Computadorizada por Raios X/métodos , Derrame Pleural/diagnóstico por imagem
12.
J Am Soc Echocardiogr ; 36(4): 350-365, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36841670

RESUMO

Transcatheter therapies for structural heart disease continue to grow at a rapid pace, and echocardiography is the primary imaging modality used to support such procedures. Transesophageal echocardiographic guidance of structural heart disease procedures must be performed by highly skilled echocardiographers who can provide rapid, accurate, and high-quality image acquisition and interpretation in real time. Training standards are needed to ensure that interventional echocardiographers have the necessary expertise to perform this complex task. This document provides guidance on all critical aspects of training for cardiology and anesthesiology trainees and postgraduate echocardiographers who plan to specialize in interventional echocardiography. Core competencies common to all transcatheter therapies are reviewed in addition to competencies for each specific transcatheter procedure. A core principle is that the length of interventional echocardiography training or achieved procedure volumes are less important than the demonstration of procedure-specific competencies within the milestone domains of knowledge, skill, and communication.


Assuntos
Cardiologia , Cardiopatias , Humanos , Estados Unidos , Ecocardiografia/métodos , Ecocardiografia Transesofagiana/métodos , Sociedades Médicas
13.
Curr Cardiol Rep ; 25(3): 97-107, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36680732

RESUMO

PURPOSE OF REVIEW: Percutaneous structural interventions have provided patients with an effective therapeutic option, and its growth has been aided by echocardiography. We describe the vital role that transesophageal echocardiography (TEE) plays in screening patients prior to their procedure. RECENT FINDINGS: A multimodality imaging approach is employed by the valve team, but TEE plays a unique role in diagnosis and planning. Utilization of all TEE views and features such as biplane, 3D imaging, and multiplanar reconstruction ensures accurate assessment of the structural lesion of interest. The role of TEE remains essential in the planning of structural interventions, and these studies should be performed in a systematic and comprehensive manner.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ecocardiografia Tridimensional , Humanos , Ecocardiografia Transesofagiana/métodos , Ecocardiografia Tridimensional/métodos , Imagem Multimodal
14.
JACC Cardiovasc Imaging ; 16(5): 591-605, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36681586

RESUMO

BACKGROUND: Apical left ventricular (LV) aneurysms in hypertrophic cardiomyopathy (HCM) are associated with adverse outcomes. The reported frequency of mid-LV obstruction has varied from 36% to 90%. OBJECTIVES: The authors sought to ascertain the frequency of mid-LV obstruction in HCM apical aneurysms. METHODS: The authors analyzed echocardiographic and cardiac magnetic resonance examinations of patients with aneurysms from 3 dedicated programs and compared them with 63 normal controls and 47 controls with apical-mid HCM who did not have aneurysms (22 with increased LV systolic velocities). RESULTS: There were 108 patients with a mean age of 57.4 ± 13.5 years; 40 (37%) were women. A total of 103 aneurysm patients (95%) had mid-LV obstruction with mid-LV complete systolic emptying. Of the patients with obstruction, 84% had a midsystolic Doppler signal void, a marker of complete flow cessation, but only 19% had Doppler systolic gradients ≥30 mm Hg. Five patients (5%) had relative hypokinesia in mid-LV without obstruction. Aneurysm size is not bimodal but appears distributed by power law, with large aneurysms decidedly less common. Comparing mid-LV obstruction aneurysm patients with all control groups, the short-axis (SAX) systolic areas were smaller (P < 0.007), the percent SAX area change was greater (P < 0.005), the papillary muscle (PM) areas were larger (P < 0.003), and the diastolic PM areas/SAX diastolic areas were greater (P < 0.005). Patients with aneurysms had 22% greater SAX PM areas compared with those with elevated LV velocities but no aneurysms (median: 3.00 cm2 [IQR: 2.38-3.70 cm2] vs 2.45 [IQR: 1.81-2.95 cm2]; P = 0.004). Complete emptying occurs circumferentially around central PMs that contribute to obstruction. Late gadolinium enhancement was always brightest and the most transmural apical of, or at the level of, complete emptying. CONCLUSIONS: The great majority (95%) of patients in the continuum of apical aneurysms have associated mid-LV obstruction. Further research to investigate obstruction as a contributing cause to apical aneurysms is warranted.


Assuntos
Cardiomiopatia Hipertrófica , Meios de Contraste , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Masculino , Valor Preditivo dos Testes , Gadolínio , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/patologia , Ventrículos do Coração/diagnóstico por imagem
16.
J Am Soc Echocardiogr ; 36(1): 105-110, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36174809

RESUMO

Despite many recent advances in three-dimensional (3D) transesophageal echocardiography (TEE) imagining, the process of orienting 3D TEE images is nonintuitive and uses assumptions based on idealized anatomy. Correlating two-dimensional TEE cross-sectional images to 3D reconstructions remains an additional challenge. In this article, we suggest the repurposing of the stitching artifact generated in 2-beat electrocardiogram-gated 3D TEE as a means of exactly orienting 3D images within a patient's unique anatomy. We demonstrate the application of this strategy to assess a normal mitral valve to localize scallops of mitral valve prolapse and to visualize typical left atrial appendage two-dimensional cuts in a 3D space. By taking command of stitching artifacts, cardiac imagers can successfully navigate the complex structures of the heart for optimal, individualized echocardiographic views.


Assuntos
Ecocardiografia Tridimensional , Prolapso da Valva Mitral , Humanos , Ecocardiografia Transesofagiana/métodos , Artefatos , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos
17.
Echocardiography ; 39(10): 1348-1358, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36198094

RESUMO

INTRODUCTION: Gram-negative organisms of the AACEK group, formerly known as HACEK, rarely cause endocarditis. CASE SERIES: We present three cases of bacterial endocarditis, involving native and prosthetic valves, caused by AACEK organisms. In two patients, Cardiobacterium hominis was the responsible organism, and in a third, Aggregatibacter aphrophilus was implicated. A dental source of infection was identified in two patients, and in all three patients, the presentation of endocarditis was subacute. DISCUSSION: This case series highlights the indolent nature of infection with the AACEK organisms. It also demonstrates the crucial role of multimodality imaging, especially transesophageal echocardiography, in the diagnosis of AACEk endocarditis of both native and prosthetic valves, and in delineating the extent of abscess in those with prosthetic valve infection.


Assuntos
Endocardite Bacteriana , Endocardite , Humanos , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/diagnóstico por imagem , Ecocardiografia Transesofagiana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...