Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 109(7): 070801, 2012 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-23006352

RESUMO

We report the measurement of the time of flight of ∼17 GeV ν(µ) on the CNGS baseline (732 km) with the Large Volume Detector (LVD) at the Gran Sasso Laboratory. The CERN-SPS accelerator has been operated from May 10th to May 24th 2012, with a tightly bunched-beam structure to allow the velocity of neutrinos to be accurately measured on an event-by-event basis. LVD has detected 48 neutrino events, associated with the beam, with a high absolute time accuracy. These events allow us to establish the following limit on the difference between the neutrino speed and the light velocity: -3.8 × 10(-6) < (v(ν)-c)/c < 3.1 × 10(-6) (at 99% C.L.). This value is an order of magnitude lower than previous direct measurements.

2.
Phys Rev Lett ; 107(13): 131302, 2011 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-22026838

RESUMO

We present results from the direct search for dark matter with the XENON100 detector, installed underground at the Laboratori Nazionali del Gran Sasso of INFN, Italy. XENON100 is a two-phase time-projection chamber with a 62 kg liquid xenon target. Interaction vertex reconstruction in three dimensions with millimeter precision allows the selection of only the innermost 48 kg as the ultralow background fiducial target. In 100.9 live days of data, acquired between January and June 2010, no evidence for dark matter is found. Three candidate events were observed in the signal region with an expected background of (1.8 ± 0.6) events. This leads to the most stringent limit on dark matter interactions today, excluding spin-independent elastic weakly interacting massive particle (WIMP) nucleon scattering cross sections above 7.0 × 10(-45) cm(2) for a WIMP mass of 50 GeV/c(2) at 90% confidence level.

3.
Phys Rev Lett ; 101(11): 112003, 2008 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-18851276

RESUMO

Inclusive K_{S};{0}K_{S};{0} production in ep collisions at the DESY ep collider HERA was studied with the ZEUS detector using an integrated luminosity of 0.5 fb;{-1}. Enhancements in the mass spectrum were observed and are attributed to the production of f_{2}(1270)/a_{2};{0}(1320), f_{2};{'}(1525) and f_{0}(1710). Masses and widths were obtained using a fit which takes into account theoretical predictions based on SU(3) symmetry arguments, and are consistent with the Particle Data Group values. The f_{0}(1710) state, which has a mass consistent with a glueball candidate, was observed with a statistical significance of 5 standard deviations. However, if this state is the same as that seen in gammagamma-->K_{S};{0}K_{S};{0}, it is unlikely to be a pure glueball state.

4.
EDTNA ERCA J ; 23(3): 45-7, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9664009

RESUMO

Vascular access recirculation is one of the main factors influencing dialysis efficiency. The underestimation of or mistakes in the measurement of access recirculation causes a discrepancy between dialysis prescription and the actual dose of dialysis administered. Moreover, access recirculation is known to increase during a dialysis session. Therefore, the evaluation of recirculation is necessary to correctly prescribe dialysis and the ideal measurement method should be very accurate and feasible at any moment during a dialysis session.


Assuntos
Velocidade do Fluxo Sanguíneo , Monitorização Fisiológica/métodos , Diálise Renal/normas , Falha de Equipamento , Hemorreologia , Humanos , Falência Renal Crônica/terapia , Prescrições