Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Adv Sci (Weinh) ; : e2308561, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38590131

RESUMO

Underwater organisms exhibit sophisticated propulsion mechanisms, enabling them to navigate fluid environments with exceptional dexterity. Recently, substantial efforts have focused on integrating these movements into soft robots using smart shape-changing materials, particularly by using light for their propulsion and control. Nonetheless, challenges persist, including slow response times and the need of powerful light beams to actuate the robot. This last can result in unintended sample heating and potentially necessitate tracking specific actuation spots on the swimmer. To tackle these challenges, new azobenzene-containing photopolymerizable inks are introduced, which can be processed by extrusion printing into liquid crystalline elastomer (LCE) elements of precise shape and morphology. These LCEs exhibit rapid and significant photomechanical response underwater, driven by moderate-intensity ultraviolet (UV) and green light, being the actuation mechanism predominantly photochemical. Inspired by nature, a biomimetic four-lapped ephyra-like LCE swimmer is printed. The periodically illumination of the entire swimmer with moderate-intensity UV and green light, induces synchronous lappet bending toward the light source and swimmer propulsion away from the light. The platform eliminates the need of localized laser beams and tracking systems to monitor the swimmer's motion through the fluid, making it a versatile tool for creating light-fueled robotic LCE free-swimmers.

2.
J Clin Med ; 12(13)2023 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-37445578

RESUMO

BACKGROUND: The gold standard for the treatment of cardiac implantable electronic devices (CIEDs)-related infection and lead malfunction is transvenous lead extraction (TLE). To date, the risk of mortality directly related to TLE procedures is relatively low, but data on post-procedural and long-term mortality are limited, even more in the aging population. METHODS: Consecutive patients with CIEDs who underwent TLE were retrospectively studied. The primary outcome was the endpoint of death, considering independent predictors of long-term clinical outcomes in the TLE aging population comparing patients with and without infection. RESULTS: One hundred nineteen patients (male 77%; median age 76 years) were included in the analysis. Eighty-two patients (69%) documented infection, and thirty-seven (31%) were extracted for a different reason. Infected patients were older (80 vs. 68 years, p-value > 0.001) with more implanted catheters (p-value < 0.001). At the last follow-up (FU) available (median FU 4.1 years), mortality reached 37% of the patient population, showing a statistically significant difference between infected versus non-infected groups. At univariable analysis, age at TLE, atrial fibrillation, and anemia remained significant correlates of mortality; at multivariable analysis, only patients with anemia and atrial fibrillation have a 2.3-fold (HR 2.34; CI 1.16-4.75) and a 2.5-fold (HR 2.46; CI 1.33-4.54) increased rate of death, respectively. CONCLUSION: Our long-term data showed that aging patients who underwent TLE for CIED-related infection exhibit a high mortality risk during a long-term follow-up, potentially leading to a rapid and effective procedural approach in this patient population.

3.
J Cardiovasc Med (Hagerstown) ; 23(1): 22-27, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34545009

RESUMO

AIMS: The coronavirus disease-19 (COVID-19) outbreak has been recently associated with lower hospitalization rates for acute coronary syndromes. Aim of the study was to investigate whether a similar behaviour is observed in admissions for urgent pacemaker implant. METHODS: This retrospective study included 1315 patients from 18 hospitals in Northern Italy with a high number of COVID-19 cases. Hospitalization rates for urgent pacemaker implant were compared between the following periods: 20 February to 20 April 2020 (case period); from 1 January to 19 February 2020 (intra-year control period); from 20 February to 20 April 2019 (inter-year control period). RESULTS: The incidence rate of urgent implants was 5.0/day in the case period, 6.0/day in the intra-year control period and 5.8/day in the inter-year control period. Incidence rate in the case period was significantly lower than both the intra-year [incidence rate ratio (IRR): 0.81, 95% CI 0.67-0.99, P = 0.040] and inter-year control periods (IRR: 0.79, 95% CI 0.66-0.95, P = 0.012); this reduction was highest after the national lockdown (IRR 0.68, 95% CI 0.52-0.91, P = 0.009). The prevalence of residents in rural areas undergoing urgent pacemaker implant was lower in the case period (36%) than in both the intra-year (47%, P = 0.03) and inter-year control periods (51%, P = 0.002). Elective pacemaker implants also decreased in the case period, with the incidence rate here being 3.5/day vs. 6.4/day in the intra-year (-45%) and 6.9/day in the inter-year period (-49%). CONCLUSION: Despite severe clinical patterns, the COVID-19 outbreak has negatively affected the population presentation to Emergency Departments for bradyarrhythmias requiring urgent pacemaker implant in Northern Italy. This mainly occurred after the national lockdown and concerned patients living in rural areas.


Assuntos
Bradicardia/epidemiologia , Bradicardia/terapia , COVID-19/epidemiologia , Surtos de Doenças/estatística & dados numéricos , Procedimentos Cirúrgicos Eletivos/estatística & dados numéricos , Emergências/epidemiologia , Marca-Passo Artificial/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Incidência , Itália/epidemiologia , Masculino , Estudos Retrospectivos
4.
Front Cardiovasc Med ; 8: 692943, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34395560

RESUMO

Background: When an implantable-cardioverter defibrillator (ICD) lead becomes non-functional, a recommendation currently exists for either lead abandonment or removal. Lead abandonment and subcutaneous ICD (S-ICD) implantation may represent an additional option for patients who do not require pacing. The aim of this study was to investigate the outcomes of a strategy of lead abandonment and S-ICD implantation in the setting of lead malfunction. Methods: We analyzed all consecutive patients who underwent S-ICD implantation after abandonment of malfunctioning leads and compared their outcomes with those of patients who underwent extraction and subsequent reimplantation of a single-chamber transvenous ICD (T-ICD). Results: Forty-three patients underwent S-ICD implantation after abandonment of malfunctioning leads, while 62 patients underwent extraction and subsequent reimplantation of a new T-ICD. The two groups were comparable. In the extraction group, no major complications occurred during extraction, while the procedure failed and an S-ICD was implanted in 4 patients. During a median follow-up of 21 months, 3 major complications or deaths occurred in the S-ICD group and 11 in the T-ICD group (HR 1.07; 95% CI 0.29-3.94; P = 0.912). Minor complications were 4 in the S-ICD group and 5 in the T-ICD group (HR 2.13; 95% CI 0.49-9.24; P = 0.238). Conclusions: In the event of ICD lead malfunction, extraction avoids the potential long-term risks of abandoned leads. Nonetheless the strategy of lead abandonment and S-ICD implantation was feasible and safe, with no significant increase in adverse outcomes, and may represent an option in selected clinical settings. Further studies are needed to fully understand the potential risks of lead abandonment. Clinical Trial Registration: URL: ClinicalTrials.gov Identifier: NCT02275637.

5.
J Cardiovasc Med (Hagerstown) ; 22(2): 118-125, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32941323

RESUMO

AIMS: The role of the implantable cardioverter defibrillator (ICD) in primary prevention real-world population is debated. We sought to evaluate the incidence, predictors and prognostic impact of ICD shocks in consecutive heart failure patients implanted for primary prevention at our tertiary institution. METHODS AND RESULTS: We retrospectively selected a sample of 497 patients (mean age 64.8 years, 82.1% men, average left ventricular ejection fraction, LVEF, 27.1%). At long-term follow-up (median time 70.4 months), total mortality was 40.8%, and 16.5% of patients had received at least one appropriate shock (3.12%/year). Inappropriate shock [odds ratio (OR) 1.93, 95% confidence interval (95% CI) 1.08-3.47; P = 0.027] and length of follow-up (1 year, OR 1.01, 95% CI 1.00-1.01; P = 0.0031) were associated with the occurrence of appropriate shock, whereas atrial fibrillation (OR 2.65, 95% CI 1.55-4.51, P < 0.001), length of follow-up (1-year OR 1.01, 95% CI 1.00-1.01, P < 0.001) and appropriate shock (OR 1.93, 95% CI 1.08-3.47, P = 0.027) were associated with the occurrence of inappropriate shock. Neither appropriate nor inappropriate shock independently increased mortality risk, whereas older age (hazard ratio 1.05; 95% CI 1.04-1.07; P < 0.001), atrial fibrillation (hazard ratio 2.25; 95% CI 1.67-3.02; P < 0.001) and lower LVEF (hazard ratio 0.97; 95% CI 0.94-0.99; P = 0.004) did. CONCLUSION: Incidence of shocks in real-world primary prevention ICD recipients might be lower than expected, and the association between ICD shocks and prolongation of survival is not as clear-cut as might be perceived. Further investigations from larger real-world samples are warranted.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/estatística & dados numéricos , Cardioversão Elétrica/métodos , Insuficiência Cardíaca/terapia , Prevenção Primária/métodos , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Idoso , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Cardioversão Elétrica/estatística & dados numéricos , Feminino , Seguimentos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/fisiopatologia , Humanos , Incidência , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
6.
Int J Cardiol ; 326: 248-251, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33242510

RESUMO

OBJECTIVES: To clarify the meaning of elevated cardiac troponin in elite soccer athletes previously infected with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and screened for cardiovascular involvement in the wake of competitive sport resumption. METHODS: We designed a retrospective cohort study with the collaboration of two Italian Serie A teams. Soccer players from both rosters (58 athletes) were systematically analysed. For every SARS-CoV-2 positive athlete, the Italian Soccer Federation protocol requested full blood tests including high-sensitivity cardiac troponin I (hs-cTnI), along with a complete cardiovascular examination. We extended the analysis to SARS-CoV-2 negative athletes. RESULTS: A total of 13/58 players (22.4%) suffered from SARS-CoV-2infection: all had a negative cardiovascular examination and 2/13 (15%) showed increased hs-cTnI values (120.8 pg/ml and 72,6 pg/ml, respectively; upper reference level 39.2 pg/ml), which did not track with inflammatory biomarkers. Regarding the 45/58 (77.6%) non infected athletes, a slight increase in hs-cTnI was observed in 2 (4.5%) subjects (values: 61 pg/ml and 75 pg/ml respectively). All hs-cTnI positive athletes (4/58, 7%) underwent cardiac magnetic resonance (CMR), that excluded any cardiac injury. CONCLUSIONS: In our retrospective study, SARS-CoV-2 infection in elite soccer athletes was not associated to clinical or biomarkers abnormalities. Increased hs-cTnI was rare and not significantly associated with previous SARS-COV2 infection nor with pathological findings at CMR, albeit elevated hs-cTnI was numerically more prevalent in the infected group.


Assuntos
Atletas , COVID-19/sangue , SARS-CoV-2/isolamento & purificação , Futebol/fisiologia , Troponina C/sangue , Biomarcadores/sangue , COVID-19/diagnóstico , COVID-19/epidemiologia , Estudos de Coortes , Humanos , Itália/epidemiologia , Estudos Retrospectivos
7.
Clin Case Rep ; 8(12): 3458-3462, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33363951

RESUMO

New tools of mapping systems may allow to detect residual conduction around the atriotomy and could eliminate the subjectivity of the human eye, analyzing thousands of electrograms in a matter of seconds and providing a clear and fast identification.

8.
Curr Radiopharm ; 13(3): 238-242, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32445458

RESUMO

BACKGROUND: Lung cancer is the neoplasm with the highest prevalence and mortality rates in the world. Most patients with lung cancer that are symptomatic have hemoptysis, coughing, shortness of breath, chest pain and persistent infections. Less than 10% of patients are asymptomatic when the tumor is detected as an incidental finding. OBJECTIVE: The present expert review aims to describe the use of radiological imaging modalities for the diagnosis of lung cancer. METHODS: Some papers were selected from the international literature, by using mainly Pubmed as a source. RESULTS: Chest x-ray (CXR) is the first investigation performed during the workup of suspected lung cancer. In the absence of a rib erosion, CXR cannot distinguish between benign and malignant masses, therefore computed tomography (CT) with contrast enhancement should be performed in order to obtain a correct staging. Magnetic resonance imaging of the chest is considered a secondary approach as the respiratory movement affects the overall results. CONCLUSION: Radiological imaging is essential for the management of patients affected by lung cancer.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Diagnóstico Diferencial , Humanos , Neoplasias Pulmonares/patologia
9.
Radiol Med ; 124(8): 714-720, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30900132

RESUMO

AIMS AND OBJECTIVES: This study aimed to analyse the key factors that influence the overimaging using X-ray such as self-referral, defensive medicine and duplicate imaging studies and to emphasize the ethical problem that derives from it. MATERIALS AND METHODS: In this study, we focused on the more frequent sources of overdiagnosis such as the total-body CT, proposed in the form of screening in both public and private sector, the choice of the most sensitive test for each pathology such as pulmonary embolism, ultrasound investigations mostly of the thyroid and of the prostate and MR examinations, especially of the musculoskeletal system. RESULTS: The direct follow of overdiagnosis and overimaging is the increase in the risk of contrast media infusion, radiant damage, and costs in the worldwide healthcare system. The theme of the costs of overdiagnosis is strongly related to inappropriate or poorly appropriate imaging examination. CONCLUSIONS: We underline the ethical imperatives of trust and right conduct, because the major ethical problems in radiology emerge in the justification of medical exposures of patients in the practice. A close cooperation and collaboration across all the physicians responsible for patient care in requiring imaging examination is also important, balancing possible ionizing radiation disadvantages and patient benefits in terms of care.


Assuntos
Medicina Defensiva/ética , Uso Excessivo dos Serviços de Saúde , Autorreferência Médica/ética , Proteção Radiológica , Radiologia/ética , Temas Bioéticos , Meios de Contraste/administração & dosagem , Meios de Contraste/efeitos adversos , Humanos , Imageamento por Ressonância Magnética/ética , Imageamento por Ressonância Magnética/estatística & dados numéricos , Masculino , Uso Excessivo dos Serviços de Saúde/economia , Próstata/diagnóstico por imagem , Exposição à Radiação/efeitos adversos , Exposição à Radiação/ética , Radiologia/economia , Sensibilidade e Especificidade , Glândula Tireoide/diagnóstico por imagem , Imagem Corporal Total/ética , Imagem Corporal Total/métodos
10.
Heart Rhythm ; 16(4): 564-571, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30366163

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) does not require the insertion of any leads into the cardiovascular system. OBJECTIVE: The aims of the study were to describe current practice and to measure outcomes associated with S-ICD or standard single-chamber transvenous ICD (TV-ICD) use after TV-ICD explantation. METHODS: We analyzed all consecutive patients who underwent transvenous extraction of an ICD and subsequent implantation of an S-ICD or a single-chamber TV-ICD at 12 Italian centers from 2011 to 2017. RESULTS: A total of 229 patients were extracted and subsequently reimplanted with an S-ICD (90; 39%) or a single-chamber TV-ICD (139; 61%). S-ICD implantation increased from 9% in 2011 to 85% in 2017 (P < .001). Patients reimplanted with an S-ICD were younger (53 ± 13 years vs 60 ± 18 years; P = .011) and more frequently had undergone extraction owing to infection (73% vs 52%; P < .001). The rates of complications at follow-up were comparable between groups (hazard ratio 0.97; 95% confidence interval 0.49-1.92; P = .940). No lead failures, systemic infections, or system-related deaths occurred in the S-ICD group. In the TV-ICD group, 1 lead fracture occurred and 2 systemic infections were reported, resulting in death in 1 case. In the S-ICD group, the rate of complications was lower when the generator was positioned in a sub- or intermuscular pocket (hazard ratio 0.21; 95% confidence interval 0.05-0.87; P = .048). CONCLUSION: Our results show an increasing use of S-ICD over the years in patients undergoing TV-ICD explantation. An S-ICD is preferably adopted in young patients, mostly in the case of infection. The complication rate was comparable between groups and decreased when a sub- or intermuscular S-ICD generator position was adopted.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Remoção de Dispositivo , Eletrodos Implantados , Padrões de Prática Médica , Desfibriladores Implantáveis/efeitos adversos , Ecocardiografia , Eletrocardiografia , Eletrodos Implantados/efeitos adversos , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Retratamento , Estudos Retrospectivos
11.
Langmuir ; 34(43): 12882-12888, 2018 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-30286294

RESUMO

We report the results of comprehensive experiments and numerical calculations of interfacial morphologies of water confined to the hydrophilic top face of rectangular posts subjected to vertical vibrations. In response to mechanical driving, an initially flat liquid channel is collected into a liquid bulge that forms in the center of the rectangular post if the acceleration exceeds a certain threshold. The bulge morphology persists after the driving is switched off, in agreement with the morphological bistability of static interfacial shapes on posts with large length-to-width ratios. In a narrow frequency band, the channel does not decay into a bulge at any acceleration amplitude, but displays irregular capillary waves and sloshing instead. On short posts, however, a liquid bulge can be dynamically sustained through vertical vibrations but quickly decays into a homogeneous channel after the external driving is stopped. To explain the dynamic bulging of the liquid interface, we propose an effective lifting force pulling on the drop's slowly moving center of mass in the presence of fast oscillation modes.

12.
Eur J Hybrid Imaging ; 2(1): 2, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29782588

RESUMO

OBJECTIVE: to determine the clinical significance of ground glass pulmonary nodules, either pure (GGNs) or mixed with the presence of solid component (MPNs), in patients with known pulmonary or extra-thoracic malignancies and to evaluate the role of computed tomography (CT) and positron emission tomography (PET)/CT in their diagnosis and follow-up. METHODS: A total of 130 nodules in 68 patients were revealed: 119 GGNs and 11 MPNs. GGN lesions were found in 58 patients, MPNs in eight, and in two cases, both. The median diameter of the nodules was 7 mm (3-30 mm). Moreover, 27 patients, who had a pars-solid >5 mm in the GGN or a pure GGN with a diameter > 5 mm, underwent FDG PET/CT. The median follow-up with CT was >3 years. RESULTS: The comparison between the first and the last positive CT scan showed that GGNs and/or MPNs remained unchanged for a median period of 18 months (range 11-48 months) in 53 patients, they disappeared after a median of 3.5 months (range 2-11 months) in 12 and increased in diameter after a median period of 17 months (range 12-67 months) in 3. In particular of these latter patients, two had malignant lesions. Only three patients with a single nodule showed a significant uptake of FDG at PET/CT. CONCLUSION: in the evaluation of GGNs and MNPs, CT examinations performed after 3 months often showed some changes, mainly with respect to nodules disappearing. PET/CT often plays no role but it can exclude malignancy at the end of staging. Finally, in patients with known pulmonary or extra-thoracic malignancies showing GGNs or MPNs, a 3-year CT follow up is justified, due to the slow growth rate of these lesions.

13.
Phys Rev E ; 97(2-1): 022610, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29548231

RESUMO

We systematically investigate the role of different swimming patterns on the concentration distribution of bacterial suspensions confined between two flat walls, by considering wild-type motility Escherichia coli and Pseudomonas aeruginosa, which perform Run and Tumble and Run and Reverse patterns, respectively. The experiments count motile bacteria at different distances from the bottom wall. In agreement with previous studies, an accumulation of motile bacteria close to the walls is observed. Different wall separations, ranging from 100 to 250µm, are tested. The concentration profiles result to be independent on the motility pattern and on the walls' separation. These results are confirmed by numerical simulations, based on a collection of self-propelled dumbbells-like particles interacting only through steric interactions. The good agreement with the simulations suggests that the behavior of the investigated bacterial suspensions is determined mainly by steric collisions and self-propulsion, as well as hydrodynamic interactions.


Assuntos
Escherichia coli/fisiologia , Movimento , Pseudomonas aeruginosa/fisiologia , Modelos Biológicos
15.
Tumori ; 92(1): 1-5, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16683376

RESUMO

AIMS AND BACKGROUND: Service mammography screening has been reported to have suboptimal performance compared to controlled trials. The aim of this study was to evaluate the sensitivity of the mammography screening program in four Local Health Units (ASL) and the possible causes of diagnostic error in cases further surfacing as interval cancers. MATERIAL AND METHODS: Interval cancers were identified by cross checking of screened women databases with hospital discharge records reporting breast cancer. Proportional interval cancer incidence (observed interval cancers/expected invasive cancers) was determined by matching the database of women screened during 1999-2002 to the hospital discharge records databases during 1999-2003. The ratio of observed interval cancer rate to underlying incidence was compared to international standards and with literature data. Screening mammograms reported as negative and followed by interval cancers were randomly mixed with true-negative controls, and the resulting set underwent blind review by an external radiologist who applied the conventional criteria recommended for the classification of the type of diagnostic error (occult, minimal signs, screening error). RESULTS: Matching of screening archives with the hospital discharge records databases allowed for the identification of 154 invasive interval cancers compared to 480 expected. The proportional observed/expected interval cancer incidence in the first and second year of the interval was 21% and 46%, respectively (ASL 1 = 14% or 38%, ASL 2 = 19% or 48%, ASL 3 = 30% or 53%, ASL 4 = 25% or 49%). Radiological review included 38 further interval cancer cases, identified after the time limits defined for proportional interval cancer incidence assessment, and could not include 18 interval cancers, not retrieved from ASL 4 archives: overall, 174 interval cancers were reviewed, of which 135 were classified as occult (77.3%) (ASL 1 = 83.3%, ASL 2 = 71.1%, ASL 3 = 78.6%, ASL 4 = 75%), 12 (6.9%) as minimal signs (ASL 1 = 6.6%, ASL 2 = 11.5%, ASL 3 = 2.4%, ASL 4 = 5%), and 27 (15.5%) as screening error (ASL 1 = 8.3%, ASL 2 = 17.3%, ASL 3 = 19.0%, ASL 4 = 25%). CONCLUSIONS: Observed proportional interval cancer incidence was lower than commonly reported for service screening programs and currently recommended (< 30% in the first, < 50% in the second year of the interval). The analysis of interval cancer causes showed a screening error rate below the maximum acceptable standard (< 20% of interval cancers should be classified as screening error) in three of four programs and in average figures. Substantial differences observed among single programs (one did not comply to recommended standards) suggest that space is available for the improvement of overall performance by optimizing program organization and by further training of radiologists. Overall, the analysis showed a good sensitivity of the screening program in the Veneto Region, although the performance was inferior to that of excellence centers, and further action to improve it is possible. Assessment and review of interval cancers is an early indicator of screening efficacy which has not yet been fully adopted in Italian screening programs. Although using hospital discharge records to identify interval cancers may be affected by limited errors, such a procedure is particularly convenient, as data from hospital discharge records are available much in advance compared to cancer registries and are the most reliable source of information for areas uncovered by a cancer registry. Hospital discharge records-based procedures for interval cancers assessment should be employed routinely in screening programs.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/normas , Programas de Rastreamento/normas , Controle de Qualidade , Qualidade da Assistência à Saúde , Neoplasias da Mama/epidemiologia , Erros de Diagnóstico , Feminino , Humanos , Incidência , Itália , Programas de Rastreamento/métodos , Valor Preditivo dos Testes , Avaliação de Programas e Projetos de Saúde , Modelos de Riscos Proporcionais , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...