Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Ultrasound Med ; 34(6): 1115-22, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26014332

RESUMO

OBJECTIVES: Ultrasound contrast agents (UCAs) enhance cardiovascular ultrasound imaging. Adverse biological effects have occurred after administration of UCAs, and more research is needed for a comprehensive understanding of the risks involved. We used the ApoE(-/-) mouse model of atherosclerosis to characterize the effects of ultrasound and UCAs on atherosclerosis and plasma biomarkers. METHODS: Male ApoE(-/-) mice (8 weeks old; n = 24) were intravenously infused with a UCA (2 × 10(10) Definity microbubbles per hour; Lantheus Medical Imaging, North Billerica, MA) and exposed to 2.8-MHz center frequency ultrasound (10 Hz pulse repetition frequency, 1.4 microseconds pulse duration, 2 minutes exposure duration, and 2 sites) at 1 of 3 derated peak rarefactional pressure amplitudes (0, 1.9, or 3.8 MPa), and then consumed either a chow or Western diet for 4 weeks (n = 4 per group). Blood plasma samples were collected before ultrasound exposure and at 2 and 4 weeks after exposure and assayed for total cholesterol and von Willebrand Factor (vWF). A pathologist measured atheroma thickness in formalin-fixed, hematoxylin-eosin-stained transverse aorta sections and scored them for severity of atherosclerosis. RESULTS: Plasma total cholesterol initially averaged 286 mg/dL in the Western diet group and increased to 861 mg/dL after 4 weeks on the diet (P < .0001). Total cholesterol did not increase significantly in the chow diet group. Plasma vWF increased after 2 weeks on the Western diet (P < .0001). Atheroma thickness was greater in animals consuming the Western diet than in chow-fed animals (P < .05). Ultrasound had no significant effect on plasma total cholesterol, plasma vWF, or atheroma thickness. CONCLUSIONS: Contrast ultrasound did not increase the severity of atherosclerosis or alter cardiovascular biomarkers in the ApoE(-/-) mouse model.


Assuntos
Aorta/diagnóstico por imagem , Aterosclerose/diagnóstico por imagem , Meios de Contraste/efeitos adversos , Progressão da Doença , Animais , Apolipoproteínas E , Biomarcadores/sangue , Doenças Cardiovasculares/sangue , Masculino , Camundongos , Ultrassonografia
2.
Ultrason Imaging ; 36(4): 239-55, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24970857

RESUMO

Quantitative ultrasound (QUS) imaging is hypothesized to map temperature elevations induced in tissue with high spatial and temporal resolution. To test this hypothesis, QUS techniques were examined to monitor high-intensity focused ultrasound (HIFU) exposure of tissue. In situ experiments were conducted on mammary adenocarcinoma tumors grown in rats and lesions were formed using a HIFU system. A thermocouple was inserted into the tumor to provide estimates of temperature at one location. Backscattered time-domain waveforms from the tissue during exposure were recorded using a clinical ultrasonic imaging system. Backscatter coefficients were estimated using a reference phantom technique. Two parameters were estimated from the backscatter coefficient (effective scatterer diameter (ESD) and effective acoustic concentration (EAC). The changes in the average parameters in the regions corresponding to the HIFU focus over time were correlated to the temperature readings from the thermocouple. The changes in the EAC parameter were consistently correlated to temperature during both heating and cooling of the tumors. The changes in the ESD did not have a consistent trend with temperature. The mean ESD and EAC before exposure were 120 ± 16 µm and 32 ± 3 dB/cm3, respectively, and changed to 144 ± 9 µm and 51 ± 7 dB/cm3, respectively, just before the last HIFU pulse was delivered to the tissue. After the tissue cooled down to 37 °C, the mean ESD and EAC were 126 ± 8 µm and 35 ± 4 dB/cm3, respectively. Peak temperature in the range of 50-60 °C was recorded by a thermocouple placed just behind the tumor. These results suggest that QUS techniques have the potential to be used for non-invasive monitoring of HIFU exposure.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/cirurgia , Ablação por Ultrassom Focalizado de Alta Intensidade/instrumentação , Neoplasias Mamárias Experimentais/diagnóstico por imagem , Neoplasias Mamárias Experimentais/cirurgia , Animais , Linhagem Celular Tumoral , Desenho de Equipamento , Feminino , Ratos , Ratos Endogâmicos F344 , Ultrassonografia
3.
Ultrasound Med Biol ; 39(12): 2333-41, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24035621

RESUMO

Currently, the evaluation of thyroid cancer relies on the use of fine-needle aspiration biopsy, as non-invasive imaging methods do not provide sufficient levels of accuracy for the diagnosis of this disease. In this study, the potential of quantitative ultrasound methods for characterization of thyroid tissues was studied using a rodent model ex vivo. A high-frequency ultrasonic scanning system (40 MHz) was used to scan thyroids extracted from mice that had spontaneously developed thyroid lesions (cancerous or benign). Three sets of mice were acquired having different predispositions to developing three thyroid anomalies: C-cell adenoma, papillary thyroid carcinoma (PTC) and follicular variant papillary thyroid carcinoma (FV-PTC). A fourth set of mice that did not develop thyroid anomalies (normal mice) were used as controls. The backscatter coefficient was estimated from excised thyroid lobes the different mice. From the backscatter coefficient versus frequency (25-45 MHz), the effective scatterer diameter (ESD) and effective acoustic concentration (EAC) were estimated. From the envelope of the backscattered signal, the homodyned K distribution was used to estimate the k parameter (ratio of coherent to incoherent signal energy) and the µ parameter (number of scatterers per resolution cell). Statistically significant differences were observed between cancerous thyroids and normal thyroids based on the ESD, EAC and µ parameters. The mean ESD values were 18.0 ± 0.92, 15.9 ± 0.81 and 21.5 ± 1.80 µm for the PTC, FV-PTC and normal thyroids, respectively. The mean EAC values were 59.4 ± 1.74, 62.7 ± 1.61 and 52.9 ± 3.42 dB (mm(-3)) for the PTC, FV-PTC and normal thyroids, respectively. The mean µ values were 2.55 ± 0.37, 2.59 ± 0.43 and 1.56 ± 0.99 for the PTC, FV-PTC and normal thyroids, respectively. Statistically significant differences were observed between cancerous thyroids and C-cell adenomas based on the ESD and EAC parameters, with an estimated ESD value of 21.3 ± 1.50 µm and EAC value of 54.7 ± 2.24 dB mm(-3) for C-cell adenomas. These results suggest that high-frequency quantitative ultrasound may enhance the ability to detect and classify diseased thyroid tissues.


Assuntos
Algoritmos , Modelos Animais de Doenças , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Ultrassonografia/métodos , Animais , Humanos , Camundongos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
J Acoust Soc Am ; 134(1): 686-93, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23862841

RESUMO

Simple scattering media fit scattering model theories much better than more complex scattering media. Tissue is much more complex as an acoustic scattering media and to date there has not been an adequate scattering model that fits it well. Previous studies evaluated the scattering characteristics of simple media (grouping of cells at various number densities) and fit them to the concentric spheres scattering model theory. This study is to increase the complexity of the media to provide insight into the acoustic scattering characteristics of tissue, and specifically two tumor types. Complementing the data from the tumors is 100% volume fraction cell pellets of the same cell lines. Cell pellets and ex vivo tumors are scanned using high-frequency single-element transducers (9-105 MHz), and the attenuation and backscatter coefficient (BSC) are estimated. BSC comparisons are made between cell pellets and tumors. The results show that the 4T1 (ATCC #CRL-2539) cell pellets and tumors have similar BSC characteristics, whereas the MAT (ATCC #CRL-1666) cell pellets and tumors have significantly different BSC characteristics. Factors that yield such differences are explored. Also, the fluid-filled sphere and the concentric spheres models are evaluated against the BSC characteristics, demonstrating that further work is required.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Neoplasias Mamárias Experimentais/diagnóstico por imagem , Imagens de Fantasmas , Espalhamento de Radiação , Som , Adenocarcinoma/patologia , Animais , Linhagem Celular Tumoral , Feminino , Humanos , Neoplasias Mamárias Experimentais/patologia , Camundongos , Camundongos Endogâmicos BALB C , Transplante de Neoplasias , Ratos , Ratos Endogâmicos F344 , Transdutores , Ultrassonografia
5.
Artigo em Inglês | MEDLINE | ID: mdl-25004506

RESUMO

This contribution demonstrates that quantitative ultrasound (QUS) capabilities are platform independent, using an in vivo model. Frequency-dependent attenuation estimates, backscatter coefficient, and effective scatterer diameter estimates are shown to be comparable across four different ultrasound imaging systems with varied processing techniques. The backscatter coefficient (BSC) is a fundamental material property from which several QUS parameters are estimated; therefore, consistent BSC estimates among different systems must be demonstrated. This study is an intercomparison of BSC estimates acquired by three research groups (UIUC, UW, ISU) from four in vivo spontaneous rat mammary fibroadenomas using three clinical array systems and a single-element laboratory scanner system. Because of their highly variable backscatter properties, fibroadenomas provided an extreme test case for BSC analysis, and the comparison is across systems for each tumor, not across the highly heterogeneous tumors. RF echo data spanning the 1 to 12 MHz frequency range were acquired in three dimensions from all animals using each system. Each research group processed their RF data independently, and the resulting attenuation, BSC, and effective scatterer diameter (ESD) estimates were compared. The attenuation estimates across all systems showed the same trends and consistently fit the power-law dependence on frequency. BSCs varied among the multiple slices of data acquired by each transducer, with variations between transducers being of a similar magnitude as those from slice to slice. Variation between BSC estimates was assessed via functional signal-to-noise ratios derived from backscatter data. These functional signal-to-noise ratios indicated that BSC versus frequency variations between systems ranged from negligible compared with the noise level to roughly twice the noise level. The corresponding functional analysis of variance (fANOVA) indicated statistically significant differences between BSC curves from different systems. However, root mean squared difference errors of the BSC values (in decibels) between different transducers and imaging platforms were less than half of the BSC magnitudes in most cases. Statistical comparison of the effective scatterer diameter (ESD) estimates resulted in no significant differences in estimates from three of the four transducers used for those estimates, demonstrating agreement among estimates based on the BSC. This technical advance demonstrates that these in vivo measurements can be made in a system-independent manner; the necessary step toward clinical implementation of the technology.


Assuntos
Fibroadenoma/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Ultrassonografia/métodos , Animais , Feminino , Fibroadenoma/química , Fibroadenoma/patologia , Imagens de Fantasmas , Ratos , Ratos Sprague-Dawley
6.
J Food Res ; 2(1): 168-178, 2013 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-24672587

RESUMO

The cholesterol-fed rabbit is useful for atherosclerosis research. We describe development of a low-magnesium (Mg) cholesterol-containing diet to accelerate atherosclerosis in this model. Male New Zealand White rabbits were fed either chow or one of four atherogenic diets: 1% cholesterol 10% fat 0.11% Mg, 1% cholesterol 10% fat 0.40% Mg, 2% cholesterol 20% fat 0.11% Mg, or 2% cholesterol 20% fat 0.40% Mg. While feed intake decreased in cholesterol-fed rabbits, they were able to maintain their body weights. Rabbits consuming cholesterol experienced profound hypercholesterolemia and tissue lipid accumulation, with plasma cholesterol levels above 1500 mg/dl for all groups at the completion of the study. Liver and spleen lipid content and liver cholesterol content also increased. Aortic arch atheroma thickness was greatest in 1% cholesterol 10% fat 0.11% Mg animals. Tissue Mg levels decreased in cholesterol-fed animals compared to chow-fed controls, despite equal or greater serum Mg levels. Our results indicate that the 1% cholesterol 10% fat 0.11% Mg diet was optimal at promoting hypercholesterolemia and atherosclerosis while minimizing health complications for the animals. The low Mg cholesterol diet will be useful to other biomedical researchers interested in utilizing the rabbit for cardiovascular disease research.

7.
J Ultrasound Med ; 31(5): 711-20, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22535718

RESUMO

OBJECTIVES: Ultrasound contrast agents (UCAs) are intravenously infused microbubbles that add definition to ultrasonic images. Ultrasound contrast agents continue to show clinical promise in cardiovascular imaging, but their biological effects are not known with confidence. We used a cholesterol-fed rabbit model to evaluate these effects when used in conjunction with ultrasound (US) to image the descending aorta. METHODS: Male New Zealand White rabbits (n = 41) were weaned onto an atherogenic diet containing 1% cholesterol, 10% fat, and 0.11% magnesium. At 21 days, rabbits were exposed to contrast US at 1 of 4 pressure levels using either the UCA Definity (Lantheus Medical Imaging, Inc, North Billerica, MA) or a saline control (n = 5 per group). Blood samples were collected and analyzed for lipids and von Willebrand factor (vWF), a marker of endothelial function. Animals were euthanized at 42 days, and tissues were collected for histologic analysis. RESULTS: After adjustment for pre-exposure vWF, high-level US (in situ [at the aorta] peak rarefactional pressure of 1.4 or 2.1 MPa) resulted in significantly lower vWF 1 hour post exposure (P = .0127; P(adj) < .0762). This difference disappeared within 24 hours. Atheroma thickness in the descending aorta was lower in animals receiving the UCA compared to animals receiving saline. CONCLUSIONS: Contrast US affected the descending aorta, as evidenced by two separate outcome measures. These results may be a first step in elucidating a previously unknown biological effect of UCAs. Further research is warranted to characterize the effects of this procedure.


Assuntos
Aorta/diagnóstico por imagem , Aterosclerose/diagnóstico por imagem , Meios de Contraste/farmacologia , Fluorocarbonos/farmacologia , Hipercolesterolemia/diagnóstico por imagem , Fator de von Willebrand/análise , Animais , Modelos Animais de Doenças , Lipídeos/análise , Masculino , Coelhos , Distribuição Aleatória , Ultrassonografia
8.
J Acoust Soc Am ; 130(5): EL334-8, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22088037

RESUMO

Three-dimensional impedance maps (3DZMs) are computational models of acoustic impedance of tissue constructed from histology images. 3DZMs can be analyzed to estimate model-based quantitative ultrasound parameters such as effective scatterer diameter (ESD). In this study, 3DZMs were constructed from normal and fatty rabbit livers. Estimates of ESD were made using the fluid-filled sphere scattering model. Weighting toward smaller scatterer sizes produced ESD estimates of 7.5 ± 1.3 and 7.0 ± 0.3 µm for normal and fatty liver, respectively, approximately the size of a liver cell nucleus. This suggests the nucleus could be a primary source of scattering in liver.


Assuntos
Fígado Gorduroso/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Fígado/diagnóstico por imagem , Ultrassom , Animais , Modelos Animais de Doenças , Fígado Gorduroso/patologia , Fígado/patologia , Coelhos , Espalhamento de Radiação , Coloração e Rotulagem , Ultrassonografia
9.
IEEE Trans Med Imaging ; 30(6): 1206-13, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21278015

RESUMO

Three-dimensional impedance maps (3DZMs) are virtual volumes of acoustic impedance values constructed from histology to represent tissue microstructure acoustically. From the 3DZM, the ultrasonic backscattered power spectrum can be predicted and model based scatterer properties, such as effective scatterer diameter (ESD), can be estimated. Additionally, the 3DZM can be exploited to visualize and identify possible scattering sites, which may aid in the development of more effective scattering models to better represent the ultrasonic interaction with underlying tissue microstructure. In this study, 3DZMs were created from a set of human fibroadenoma samples. ESD estimates were made assuming a fluid-filled sphere form factor model from 3DZMs of volume 300×300×300 µm. For a collection of 33 independent human fibroadenoma tissue samples, the ESD was estimated to be 111±40.7 µm. The 3DZMs were then investigated visually to identify possible scattering sources which conformed to the estimated model scatterer dimensions. This estimation technique allowed a better understanding of the spatial distribution and variability of the estimates throughout the volume.


Assuntos
Algoritmos , Fibroadenoma/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Reconhecimento Automatizado de Padrão/métodos , Pletismografia de Impedância/métodos , Humanos , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia
10.
J Acoust Soc Am ; 130(6): 4139-47, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22225068

RESUMO

Previous work estimated the ultrasonic backscatter coefficient (BSC) from low-concentration (volume density <3%) Chinese Hamster Ovary (CHO, 6.7-µm cell radius) cell pellets. This study extends the work to higher cell concentrations (volume densities: 9.6% to 63%). At low concentration, BSC magnitude is proportional to the cell concentration and BSC frequency dependency is independent of cell concentration. At high cell concentration, BSC magnitude is not proportional to cell concentration and BSC frequency dependency is dependent on cell concentration. This transition occurs when the volume density reaches between 10% and 30%. Under high cell concentration conditions, the BSC magnitude increases slower than proportionally with the number density at low frequencies (ka<1), as observed by others. However, what is new is that the BSC magnitude can increase either slower or faster than proportionally with number density at high frequencies (ka>1). The concentric sphere model least squares estimates show a decrease in estimated cell radius with number density, suggesting that the concentric spheres model is becoming less applicable as concentration increases because the estimated cell radius becomes smaller than that measured. The critical volume density, starting from when the model becomes less applicable, is estimated to be between 10% and 30% cell volume density.


Assuntos
Modelos Biológicos , Imagens de Fantasmas , Ultrassom/instrumentação , Animais , Células CHO/fisiologia , Cricetinae , Som , Espectrografia do Som
11.
J Acoust Soc Am ; 128(5): 3175-80, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21110612

RESUMO

A cell pellet biophantom technique is introduced, and applied to the ultrasonic backscatter coefficient (BSC) estimate using Chinese hamster ovary (CHO) cells. Also introduced is a concentric sphere scattering model because of its geometrical similarities to cells with a nucleus. BSC comparisons were made between the concentric sphere model and other well-understood models for mathematical verification purposes. BSC estimates from CHO cell pellet biophantoms of known number density were performed with 40 and 80 MHz focused transducers (overall bandwidth: 26-105 MHz). These biophantoms were histologically processed and then evaluated for cell viability. Cell pellet BSC estimates were in agreement with the concentric sphere model. Fitting the model to the BSC data yielded quantitative values for the outer sphere and inner sphere. The radius of the cell model was 6.8 ± 0.7 µm; the impedance of the cytoplasm model was 1.63 ± 0.03 Mrayl and the impedance of the nuclear model was 1.55 ± 0.09 Mrayl. The concentric sphere model appears as a new tool for providing quantitative information on cell structures and will tend to have a fundamental role in the classification of biological tissues.


Assuntos
Células CHO/diagnóstico por imagem , Modelos Biológicos , Imagens de Fantasmas , Ultrassom/métodos , Ultrassonografia/métodos , Animais , Células CHO/ultraestrutura , Contagem de Células , Núcleo Celular/diagnóstico por imagem , Tamanho Celular , Cricetinae , Cricetulus , Citoplasma/diagnóstico por imagem
12.
J Ultrasound Med ; 29(9): 1267-75, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20733181

RESUMO

OBJECTIVE: The ability of ultrasound (US) and ultrasound contrast agents (UCAs) to induce angiogenesis has been explored as a means of restoring blood flow to ischemic muscle. Because UCAs demonstrate an increasing percentage of collapse cavitation with increasing US pressure (Pr), this study sought to explore the effects of a US Pr that produces 100% collapse cavitation, determine the capillary density changes, and determine the time point of angiogenic rebound in a normal animal model. METHODS: Using a 1-MHz focused transducer and a peak rarefactional US Pr of 3.8 MPa, rat gracilis muscles were exposed to US, and bioeffects were assessed. Capillary density, as a measure of angiogenesis, was examined. As an additional measure, inflammatory cells were quantified via a color threshold analysis to detect the presence of CD31 and CD34 as a percentage of the total section on stained slides. Six groups (0, 3, 6, 13, 20, and 27 days postexposure [DPE]; n = 3 each) and 5 cage controls were used to characterize the angiogenic response. RESULTS: Ultrasound-UCA treatment caused the capillary density to decrease acutely (0 DPE) by 70% and inflammatory cells to increase by up to 250%. The angiogenic rebound was observed at 3 DPE but did not return to control levels by 27 DPE, suggesting an incomplete healing response. CONCLUSIONS: Capillary destruction and inflammation played an important role in the angiogenic response induced by US-UCA. Exposure that causes 100% collapse cavitation causes capillary destruction from which normal rats are unable to recover and suggests a nontherapeutic effect.


Assuntos
Capilares/efeitos dos fármacos , Meios de Contraste/farmacologia , Fluorocarbonos/farmacologia , Isquemia/tratamento farmacológico , Músculo Esquelético/irrigação sanguínea , Neovascularização Fisiológica/efeitos dos fármacos , Ultrassom , Análise de Variância , Animais , Feminino , Distribuição Aleatória , Ratos , Ratos Sprague-Dawley , Coloração e Rotulagem
13.
J Ultrasound Med ; 29(7): 1117-23, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20587435

RESUMO

OBJECTIVE: To translate quantitative ultrasound (QUS) from the laboratory into the clinic, it is necessary to demonstrate that the measurements are platform independent. Because the backscatter coefficient (BSC) is the fundamental estimate from which additional QUS estimates are calculated, agreement between BSC results using different systems must be demonstrated. This study was an intercomparison of BSCs from in vivo spontaneous rat mammary tumors acquired by different groups using 3 clinical array systems and a single-element laboratory scanner system. METHODS: Radio frequency data spanning the 1- to 14-MHz frequency range were acquired in 3 dimensions from all animals using each system. Each group processed their radio frequency data independently, and the resulting BSCs were compared. The rat tumors were diagnosed as either carcinoma or fibroadenoma. RESULTS: Carcinoma BSC results exhibited small variations between the multiple slices acquired with each transducer, with similar slopes of BSC versus frequency for all systems. Somewhat larger variations were observed in fibroadenomas, although BSC variations between slices of the same tumor were of comparable magnitude to variations between transducers and systems. The root mean squared (RMS) errors between different transducers and imaging platforms were highly variable. The lowest RMS errors were observed for the fibroadenomas between 4 and 5 MHz, with an average RMS error of 4 x 10(-5) cm(-1)Sr(-1) and an average BSC value of 7.1 x 10(-4) cm(-1)Sr(-1), or approximately 5% error. The highest errors were observed for the carcinoma between 7 and 8 MHz, with an RMS error of 1.1 x 10(-1) cm(-1)Sr(-1) and an average BSC value of 3.5 x 10(-2) cm(-1)Sr(-1), or approximately 300% error. CONCLUSIONS: This technical advance shows the potential for QUS technology to function with different imaging platforms.


Assuntos
Neoplasias/diagnóstico por imagem , Transdutores , Animais , Ratos , Ratos Sprague-Dawley , Ultrassonografia/instrumentação
14.
Pediatr Radiol ; 40 Suppl 1: S16-20, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20607225

RESUMO

Bilateral synchronous intratesticular masses are rare but can be caused by metastatic disease to the testicle, primary testicular masses or benign etiologies such as congenital adrenal hyperplasia and granulomatous orchitis. We present an unusual case of McCune-Albright syndrome presenting with unilateral testicular enlargement and bilateral testicular masses secondary to Sertoli cell hyperplasia. To our knowledge, this is a unique case of testicular masses secondary to McCune-Albright syndrome.


Assuntos
Anormalidades Múltiplas/diagnóstico , Displasia Fibrosa Poliostótica/diagnóstico , Testículo/anormalidades , Testículo/diagnóstico por imagem , Criança , Humanos , Masculino , Radiografia , Ultrassonografia
15.
Cutis ; 82(4): 252-6, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19055168

RESUMO

Muir-Torre syndrome (MTS) is a rare disorder characterized by the presence of at least one sebaceous gland neoplasm and at least one visceral malignancy. Sebaceous adenomas, sebaceous carcinomas, and sebaceomas (sebaceous epitheliomas) are all characteristic glandular tumors of MTS. The most common visceral malignancies associated with MTS are colorectal, followed by genitourinary. These visceral malignancies frequently have a more indolent course in patients with MTS than they would otherwise. Muir-Torre syndrome is an autosomal dominant disorder; however, sporadic cases are known to develop. It often is associated with germ-line mutations in the mutS homolog 2, colon cancer, nonpolyposis type 1 (Escherichia coli) gene, MSH2, and the mutL homolog 1, colon cancer, nonpolyposis type 2 (E. coli) gene, MLH1 (similar to hereditary nonpolyposis colon cancer [HNPCC]). The diagnosis of MTS currently is based on clinical criteria; however, immunohistochemical staining for MSH2 and MLH1 can confirm the diagnosis. We report 2 patients with MTS who developed colon adenocarcinomas in conjunction with sebaceous carcinomas. Both patients demonstrated loss of MSH2 expression in tumor cells on immunohistochemical staining. One of these patients later developed gastric carcinoma, a very uncommon malignancy associated with MTS. We conclude that the diagnosis of rare sebaceous lesions associated with MTS may represent a marker of visceral disease and warrants further investigation for internal malignancies in the individual and at-risk family members.


Assuntos
Síndrome de Muir-Torre , Feminino , Humanos , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...