Artigo em Inglês | MEDLINE | ID: mdl-38618698

RESUMO

Although thoracic endovascular repair (TEVAR)-specific complications often develop, stent-graft collapse is a rare, but fatal complication that requires attention. A 62-year-old male underwent TEVAR for a saccular distal arch aortic aneurysm. After the placement of the Gore TAG (W. L. Gore & Associates, Inc., Newark, DE, USA) from zones 2 to 4, a Najuta endograft (Kawasumi Laboratories, Inc., Tokyo, Japan) was deployed from zone 0. Neither intraoperative angiography nor postoperative contrast-enhanced computed tomography (CT) showed endoleaks or migration. On day 12 after surgery, the patient suddenly lost consciousness during rehabilitation, and CT revealed the collapse of the Najuta endograft. In emergency surgery, the Najuta endograft was removed and the TAG was sutured to the aorta. Although the patient survived, he developed irreversible higher brain dysfunction. The cause of the collapse was examined by the manufacturer and only a slight bird-beak configuration was noted. There were no other findings to indicate the cause of the collapse. The Najuta endograft is a semi-customized system that is created according to the three-dimensional morphology of each individual aortic arch and, thus, is expected to follow the flexion of this vessel. Nevertheless, the risk of collapse needs to be considered.

2.
Ophthalmol Glaucoma ; 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38554811

RESUMO

PURPOSE: To investigate sectoral differences in the relationship between intraocular pressure (IOP) dynamics during dark-room prone testing (DRPT) and visual field (VF) defect progression in primary open-angle glaucoma (POAG) patients. DESIGN: Retrospective, longitudinal study. PARTICIPANTS: This retrospective study included 116 eyes of 84 POAG patients who underwent DRPT and had at least 5 reliable VF tests conducted over a more than 2-year follow-up period. We excluded eyes with mean deviation worse than -20 dB or a history of intraocular surgery or laser treatment. METHODS: Average total deviation (TD) was calculated in the superior, central, and inferior sectors of the Humphrey 24-2 or 30-2 program. During DRPT, IOP was measured in the sitting position, and after 60 minutes in the prone position in a dark room, IOP was measured again. The relationship between IOP change during DRPT, IOP after DRPT, and TD slope in each quadrant was analyzed with a linear mixed-effects model, adjusting for other potential confounding factors. MAIN OUTCOME MEASURES: Total deviation slope in each quadrant, IOP change during DRPT, and IOP after DRPT. RESULTS: Intraocular pressure after DRPT and IOP change during DRPT were 18.16 ± 3.42 mmHg and 4.92 ± 3.12 mmHg, respectively. Superior TD slope was significantly associated with both IOP after DRPT (ß = -0.28, P = 0.003) and IOP change during DRPT (ß = -0.21, P = 0.029), while central (ß = -0.05, P = 0.595; ß = -0.05; P = 0.622) and inferior (ß = 0.05, P = 0.611; ß = 0.01, P = 0.938) TD slopes were not. CONCLUSION: Dark-room prone testing might be a useful test to predict the risk of superior VF defect progression in eyes with POAG. FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38180849

RESUMO

Double valve replacement of aortic and mitral valves with intervalvular fibrous body reconstruction (Commando procedure) is a challenging operation. Particularly in redo surgery for prosthetic valve endocarditis, special techniques are needed for approaching and reconstructing the valve complex. We performed a modified Commando procedure using a double valve composite through an aorto-annulo-septotomy. This approach provided a good field of vision at the combined aortic and mitral annuli without incising the left atrial roof. The double valve composite with four-layer patch wings was useful for performing double valve replacement en bloc and aorto-annulo-septotomy closure serially. Using these techniques, we successfully performed the Commando procedure for complicated prosthetic valve endocarditis.

4.
Int Heart J ; 65(1): 29-38, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38296576

RESUMO

Comprehensive management approaches for patients with ischemic heart disease (IHD) are important aids for prognostication and treatment planning. While single-modality deep neural networks (DNNs) have shown promising performance for detecting cardiac abnormalities, the potential benefits of using DNNs for multimodality risk assessment in patients with IHD have not been reported. The purpose of this study was to investigate the effectiveness of multimodality risk assessment in patients with IHD using a DNN that utilizes 12-lead electrocardiograms (ECGs) and chest X-rays (CXRs), with the prediction of major adverse cardiovascular events (MACEs) being of particular concern.DNN models were applied to detection of left ventricular systolic dysfunction (LVSD) on ECGs and identification of cardiomegaly findings on CXRs. A total of 2107 patients who underwent elective percutaneous coronary intervention were categorized into 4 groups according to the models' outputs: Dual-modality high-risk (n = 105), ECG high-risk (n = 181), CXR high-risk (n = 392), and No-risk (n = 1,429).A total of 342 MACEs were observed. The incidence of a MACE was the highest in the Dual-modality high-risk group (P < 0.001). Multivariate Cox hazards analysis for predicting MACE revealed that the Dual-modality high-risk group had a significantly higher risk of MACE than the No-risk group (hazard ratio (HR): 2.370, P < 0.001), the ECG high-risk group (HR: 1.906, P = 0.010), and the CXR high-risk group (HR: 1.624, P = 0.018), after controlling for confounding factors.The results suggest the usefulness of multimodality risk assessment using DNN models applied to 12-lead ECG and CXR data from patients with IHD.


Assuntos
Aprendizado Profundo , Isquemia Miocárdica , Humanos , Raios X , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/epidemiologia , Medição de Risco , Eletrocardiografia
5.
Graefes Arch Clin Exp Ophthalmol ; 262(3): 949-956, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37864634

RESUMO

PURPOSE: To investigate the relationship between the dynamics of intraocular pressure (IOP) during dark-room prone testing (DRPT) and IOP over a relatively long-term follow-up period. METHODS: This retrospective study enrolled 84 eyes of 51 primary open-angle glaucoma patients who underwent DRPT for whom at least three IOP measurements made using Goldmann applanation tonometry were available over a maximum follow-up period of two years. We excluded eyes with a history of intraocular surgery or laser treatment and those with changes in topical anti-glaucoma medication during the follow-up period. In DRPT, IOP was measured in the sitting position, and after 60 min in the prone position in a dark room, IOP was measured again. In this study, IOP fluctuation refers to the standard deviation (SD) of IOP, and IOP max indicates the maximum value of IOP during the follow-up. The relationship between these parameters was analyzed with a linear mixed-effects model, adjusting for clinical parameters including age, gender, and axial length. RESULTS: IOP increased after DRPT with a mean of 6.13 ± 3.55 mmHg. IOP max was significantly associated with IOP after DRPT (ß = 0.38; p < 0.001). IOP fluctuation was significantly associated with IOP change in DRPT (ß = 0.29; p = 0.007). CONCLUSION: Our findings suggest that short-term and relatively long-term IOP dynamics are associated. Long-term IOP dynamics can be predicted by DRPT to some extent.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Humanos , Pressão Intraocular , Seguimentos , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/cirurgia , Estudos Retrospectivos
6.
Circ J ; 88(1): 146-156, 2023 Dec 25.
Artigo em Inglês | MEDLINE | ID: mdl-37967949

RESUMO

BACKGROUND: Left heart abnormalities are risk factors for heart failure. However, echocardiography is not always available. Electrocardiograms (ECGs), which are now available from wearable devices, have the potential to detect these abnormalities. Nevertheless, whether a model can detect left heart abnormalities from single Lead I ECG data remains unclear.Methods and Results: We developed Lead I ECG models to detect low ejection fraction (EF), wall motion abnormality, left ventricular hypertrophy (LVH), left ventricular dilatation, and left atrial dilatation. We used a dataset comprising 229,439 paired sets of ECG and echocardiography data from 8 facilities, and validated the model using external verification with data from 2 facilities. The area under the receiver operating characteristic curves of our model was 0.913 for low EF, 0.832 for wall motion abnormality, 0.797 for LVH, 0.838 for left ventricular dilatation, and 0.802 for left atrial dilatation. In interpretation tests with 12 cardiologists, the accuracy of the model was 78.3% for low EF and 68.3% for LVH. Compared with cardiologists who read the 12-lead ECGs, the model's performance was superior for LVH and similar for low EF. CONCLUSIONS: From a multicenter study dataset, we developed models to predict left heart abnormalities using Lead I on the ECG. The Lead I ECG models show superior or equivalent performance to cardiologists using 12-lead ECGs.


Assuntos
Aprendizado Profundo , Cardiopatias Congênitas , Dispositivos Eletrônicos Vestíveis , Humanos , Eletrocardiografia , Ecocardiografia , Hipertrofia Ventricular Esquerda/diagnóstico
7.
Cytometry A ; 103(6): 492-499, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36772915

RESUMO

Microvascular thrombosis is a typical symptom of COVID-19 and shows similarities to thrombosis. Using a microfluidic imaging flow cytometer, we measured the blood of 181 COVID-19 samples and 101 non-COVID-19 thrombosis samples, resulting in a total of 6.3 million bright-field images. We trained a convolutional neural network to distinguish single platelets, platelet aggregates, and white blood cells and performed classical image analysis for each subpopulation individually. Based on derived single-cell features for each population, we trained machine learning models for classification between COVID-19 and non-COVID-19 thrombosis, resulting in a patient testing accuracy of 75%. This result indicates that platelet formation differs between COVID-19 and non-COVID-19 thrombosis. All analysis steps were optimized for efficiency and implemented in an easy-to-use plugin for the image viewer napari, allowing the entire analysis to be performed within seconds on mid-range computers, which could be used for real-time diagnosis.


Assuntos
COVID-19 , Trombose , Humanos , Plaquetas , Processamento de Imagem Assistida por Computador/métodos , Redes Neurais de Computação
8.
PLoS One ; 18(2): e0282047, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36827337

RESUMO

PURPOSE: To investigate the association of systemic oxidative stress markers and optic nerve head (ONH) blood flow in normal-tension glaucoma (NTG) patients, as well as sex differences in this association. METHODS: This was a cross-sectional study of 235 eyes with NTG of 134 patients (56 male, 78 female; mean age, 60.9±14.1 years). Laser speckle flowgraphy (LSFG) was used to measure ONH blood flow (mean blur rate in the tissue area of the ONH; MBR-T) and LSFG pulse-waveform parameters, including flow acceleration index in the tissue area of the ONH (FAI-T). Oxidative stress markers, diacron-reactive oxygen metabolites (d-ROMs), and biological antioxidant potential (BAP) were measured with a free radical elective evaluator. Spearman's rank correlation test and a multivariate linear mixed-effect model were used to investigate factors associated with ONH blood flow. RESULTS: MBR-T was significantly correlated with age (rs = -0.28, p < 0.001), mean arterial pressure (rs = -0.20, p = 0.002), intraocular pressure (rs = 0.24, p < 0.001), peripapillary retinal nerve fiber layer thickness (rs = 0.62, p < 0.001), and disc area (rs = -0.26, p < 0.001), but not with serum d-ROM level. Separate analyses of the subjects divided by sex showed that BAP was positively correlated to MBR-T (rs = 0.21, p = 0.036) and FAI-T (rs = 0.36, p < 0.001) only in male subjects. Similarly, BAP was significantly associated with MBR-T (ß = 0.25, p = 0.026) and FAI-T (ß = 0.37, p < 0.001) in male subjects in a multivariate linear mixed-effect model. CONCLUSION: A lower serum antioxidant level, as indicated by BAP, was associated with reduced ONH blood flow only in male NTG patients. Our findings suggest that there are sex differences in the involvement of oxidative stress in the pathogenesis of reduced ocular blood flow in NTG.


Assuntos
Glaucoma de Baixa Tensão , Disco Óptico , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Disco Óptico/irrigação sanguínea , Antioxidantes , Estudos Transversais , Caracteres Sexuais , Fluxo Sanguíneo Regional/fisiologia , Pressão Intraocular , Estresse Oxidativo , Fluxometria por Laser-Doppler , Velocidade do Fluxo Sanguíneo/fisiologia
9.
Ann Vasc Dis ; 16(4): 261-264, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38188974

RESUMO

We report a case of endovascular aortic repair (EVAR) for the abdominal aortic aneurysm complicated by a saccular aneurysm due to a penetrating atherosclerotic ulcer in the severely angulated proximal landing zone. To secure the zone, coil embolization of the saccular aneurysm was performed before stent grafting to treat the abdominal aortic aneurysm. To precisely follow the severely angled proximal neck, we used the Excluder stent-graft system inserted by the body floss technique method instead of the stiff wire method to avoid accordion folding the proximal landing zone. These techniques may expand the indications of EVAR.

10.
Sci Rep ; 12(1): 17371, 2022 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-36316346

RESUMO

Internal and local modifications via ultrashort pulsed laser illumination to diamond are promising for manufacturing diamond electronic devices. The relationship between the diameter/electrical conductivity of modified regions and the laser fluence distribution was investigated. Picosecond laser illumination without scanning the laser focus fabricated short modified regions in diamond. As a result, the calculated laser fluence distribution matches the distribution of the modified regions. Wire-shaped modified regions were fabricated via laser illumination with scanning of the laser focus, and the corresponding diameter and electrical conductivity were investigated by controlling the laser focus movement distance per pulse (Vf). The modified regions fabricated with varying Vf were divided into three categories depending on the trend of the relationship between the diameter and electrical conductivity. The diameters of the modified regions were constant at the maximum values when Vf was sufficiently small, decreased with increasing Vf, and reached a minimum when Vf was sufficiently large. The modified regions became more electrically conductive with increasing Vf, even when the deposited energy per unit length decreased. Moreover, the electrical conductivity decreased significantly when the diameter became constant at the minimum value. Finally, the relationship between the diameter/electrical conductivity of the modified regions and the laser fluence distribution was elucidated.

11.
PLoS One ; 17(10): e0276928, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36301966

RESUMO

Coronary angiography (CAG) is still considered the reference standard for coronary artery assessment, especially in the treatment of acute coronary syndrome (ACS). Although aging causes changes in coronary arteries, the age-related imaging features on CAG and their prognostic relevance have not been fully characterized. We hypothesized that a deep neural network (DNN) model could be trained to estimate vascular age only using CAG and that this age prediction from CAG could show significant associations with clinical outcomes of ACS. A DNN was trained to estimate vascular age using ten separate frames from each of 5,923 CAG videos from 572 patients. It was then tested on 1,437 CAG videos from 144 patients. Subsequently, 298 ACS patients who underwent percutaneous coronary intervention (PCI) were analysed to assess whether predicted age by DNN was associated with clinical outcomes. Age predicted as a continuous variable showed mean absolute error of 4 years with R squared of 0.72 (r = 0.856). Among the ACS patients stratified by predicted age from CAG images before PCI, major adverse cardiovascular events (MACE) were more frequently observed in the older vascular age group than in the younger vascular age group (p = 0.017). Furthermore, after controlling for actual age, gender, peak creatine kinase, and history of heart failure, the older vascular age group independently suffered from more MACE (hazard ratio 2.14, 95% CI 1.07 to 4.29, p = 0.032). The vascular age estimated based on CAG imaging by DNN showed high predictive value. The age predicted from CAG images by DNN could have significant associations with clinical outcomes in patients with ACS.


Assuntos
Síndrome Coronariana Aguda , Intervenção Coronária Percutânea , Humanos , Pré-Escolar , Intervenção Coronária Percutânea/efeitos adversos , Angiografia Coronária/efeitos adversos , Síndrome Coronariana Aguda/tratamento farmacológico , Prognóstico , Redes Neurais de Computação , Fatores de Risco
13.
NMC Case Rep J ; 8(1): 21-25, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34012744

RESUMO

Here we describe a case of recurrent ischemic strokes due to fragile innominate artery plaque successfully treated using endovascular stent grafting. An 80-year-old man presented with a history of recurrent strokes that were refractory to medical treatment. Computed tomography and magnetic resonance images of the thorax revealed a gross intramural plaque in the innominate artery. He was successfully treated using endovascular stent grafting. An AFX stent graft device was used to prevent further embolic strokes. The AFX stent graft has a unique endoskeleton design with a thin-walled expanded polytetrafluoroethylene fabric-known as active sealing structure-attached to the implant. Postoperatively, the patient has experienced no recurrent strokes in over 2 years of follow-up. The stent grafting procedure could be an optimal treatment option for treating fragile innominate artery plaques.

14.
RSC Adv ; 10(11): 6460-6463, 2020 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-35496030

RESUMO

A hydrophobic diradical-platinum(ii) complex was solubilized in aqueous solutions by using bovine serum albumin and exhibited photothermal conversion under near-infrared (NIR) light irradiation. The complex was introduced into cancer cells and induced cell death upon absorption of NIR. These results imply that the complex can function as a photothermal therapeutic agent.

15.
J Neurosurg ; 131(3): 750-756, 2018 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-30192190

RESUMO

OBJECTIVE: Hypoperfusion during carotid artery cross-clamping (CC) for carotid endarterectomy (CEA) may result in the major complication of perioperative stroke. Median nerve somatosensory evoked potential (MNSSEP) monitoring, which is an established method for the prediction of cerebral ischemia, has low sensitivity in detecting such hypoperfusion. In this study the authors sought to explore the limitations of MNSSEP monitoring compared to tibial nerve somatosensory evoked potential (TNSSEP) monitoring for the detection of CC-related hypoperfusion. METHODS: The authors retrospectively analyzed data from patients who underwent unilateral CEA with routine shunt use. All patients underwent preoperative magnetic resonance angiography and were monitored for intraoperative cerebral ischemia by using MNSSEP, TNSSEP, and carotid stump pressure during CC. First, the frequency of MNSSEP and TNSSEP changes during CC were analyzed. Subsequently, variables related to stump pressure were determined by using linear analysis and those related to each of the somatosensory evoked potential (SSEP) changes were determined by using logistic regression analysis. RESULTS: A total of 94 patients (mean age 74 years) were included in the study. TNSSEP identified a greater number of SSEP changes during CC than MNSSEP (20.2% vs 11.7%; p < 0.05). Linear regression analysis demonstrated that hypoplasia of the contralateral proximal segment of the anterior cerebral artery (A1 hypoplasia) (p < 0.01) and hypoplasia of the ipsilateral precommunicating segment of the posterior cerebral artery (P1 hypoplasia) (p = 0.02) independently and negatively correlated with stump pressure. Both contralateral A1 hypoplasia (OR 26.25, 95% CI 4.52-152.51) and ipsilateral P1 hypoplasia (OR 8.75, 95% CI 1.83-41.94) were independently related to the TNSSEP changes. However, only ipsilateral P1 hypoplasia (OR 8.76, 95% CI 1.61-47.67) was independently related to MNSSEP changes. CONCLUSIONS: TNSSEP monitoring appears to be superior to MNSSEP in detecting CC-related hypoperfusion. Correlation with stump pressure and SSEP changes indicates that TNSSEP, and not MNSSEP monitoring, is a reliable indicator of cerebral ischemia in the territory of the anterior cerebral artery.


Assuntos
Isquemia Encefálica/diagnóstico , Endarterectomia das Carótidas/efeitos adversos , Potenciais Somatossensoriais Evocados/fisiologia , Complicações Intraoperatórias/diagnóstico , Nervo Mediano/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Complicações Intraoperatórias/etiologia , Monitorização Neurofisiológica Intraoperatória , Masculino , Estudos Retrospectivos , Sensibilidade e Especificidade , Nervo Tibial
17.
Interact Cardiovasc Thorac Surg ; 26(5): 878-880, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29325129

RESUMO

We applied direct septal echography in transaortic septal myectomy for left ventricular outflow tract obstruction due to hypertrophic obstructive cardiomyopathy and asymmetric septal hypertrophy. A small L-shaped probe was inserted into the right ventricle through a 2-cm incision on the right ventricular outflow tract. The probe was placed directly on the interventricular septum to visualize its actual thickness. It was also helpful to push and expose the septum into a direct field of vision through the aortic annulus. This type of direct septal echography can be useful for the successful performance of transaortic septal myectomy.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Cardiomiopatia Hipertrófica/complicações , Cirurgia Assistida por Computador/métodos , Obstrução do Fluxo Ventricular Externo/cirurgia , Septo Interventricular/diagnóstico por imagem , Septo Interventricular/cirurgia , Idoso , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/cirurgia , Feminino , Septos Cardíacos/cirurgia , Ventrículos do Coração/cirurgia , Humanos , Ultrassonografia , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/etiologia , Septo Interventricular/patologia
18.
Intern Med ; 57(10): 1425-1428, 2018 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-29321409

RESUMO

Pulmonary embolism (PE) is usually caused by thrombosis or tumor. We report the long-term survival of a patient with PE due to a leiomyosarcoma in the deep vein. A 71-year-old woman complained of dyspnea and swelling of the left lower limb. Computed tomography revealed filling defects in the pulmonary arteries and deep vein. She was diagnosed with PE caused by venous thrombosis and treated with anticoagulant therapy. Her symptoms were prolonged, and D-dimer tests remained negative. Biopsy of the substance in the deep vein revealed leiomyosarcoma. The possibility of PE caused by extravascular or intravascular tumors should be considered when a patient is negative for D-dimer.


Assuntos
Leiomiossarcoma/complicações , Extremidade Inferior/irrigação sanguínea , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/etiologia , Neoplasias Vasculares/complicações , Trombose Venosa/complicações , Idoso , Anticoagulantes/uso terapêutico , Biópsia , Feminino , Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Humanos , Embolia Pulmonar/tratamento farmacológico , Tomografia Computadorizada por Raios X , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/tratamento farmacológico
19.
Ann Thorac Surg ; 104(1): e49-e51, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28633261

RESUMO

A 76-year-old man who had undergone tricuspid annuloplasty 13 years earlier was admitted to our hospital because of a high fever. Although he was treated with antibiotics for pneumonia, a mild fever persisted. Computed tomography and gallium scintigraphy revealed a mediastinal abscess with an expanded polytetrafluoroethylene (ePTFE) membrane. There were no positive cultures or sternal changes indicating poststernotomy mediastinitis. The membrane was removed by a left parasternal approach without resternotomy, and its total removal was essential for the patient's recovery. This is the first reported case of sterile mediastinal abscess caused by an ePTFE membrane after a cardiac operation.


Assuntos
Abscesso/etiologia , Anuloplastia da Valva Cardíaca/efeitos adversos , Doenças do Mediastino/etiologia , Politetrafluoretileno/efeitos adversos , Infecção da Ferida Cirúrgica/etiologia , Insuficiência da Valva Tricúspide/cirurgia , Abscesso/diagnóstico , Abscesso/cirurgia , Idoso , Anuloplastia da Valva Cardíaca/instrumentação , Remoção de Dispositivo , Humanos , Masculino , Doenças do Mediastino/diagnóstico , Doenças do Mediastino/cirurgia , Infecção da Ferida Cirúrgica/diagnóstico , Tomografia Computadorizada por Raios X
20.
Ann Vasc Surg ; 39: 290.e17-290.e20, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27908813

RESUMO

We report a coil embolization-assisted thoracic endovascular aortic repair technique successfully applied to multiple saccular descending aortic aneurysms in a 74-year-old man. Because of the most distal aneurysm being located at the celiac trunk level and the distance between the superior mesenteric artery and the aneurysm being only 10 mm, a coil embolization of the distal saccular aneurysm was performed before stent delivery to secure a sufficient landing zone. Postoperative computed tomography showed an appropriate positioning of the endovascular devices without endoleak. This coil embolization-assisted technique may extend the indication of the endovascular aortic repair when a saccular aneurysm has an insufficient landing zone.


Assuntos
Aneurisma da Aorta Torácica/terapia , Implante de Prótese Vascular , Embolização Terapêutica , Procedimentos Endovasculares , Idoso , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/instrumentação , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Stents , Resultado do Tratamento