Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Prosthodont ; 0(0)2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37824113

RESUMO

STATEMENT OF PROBLEM: 5Y-PSZ-based zirconia dental restorations exhibit high translucency and good esthetics but have a higher fracture risk compared to 3Y-TZP. OBJECTIVES: To investigate the effect of BruxZir SteelTM treatment on the fracture resistance of zirconia three-unit bridges prepared using 5Y-PSZ-based zirconia blanks. METHODS: Three-unit zirconia bridges were milled using CAD/CAM from homogeneous bisque zirconia blanks (5Y-PSZ-based) supplied by various manufacturers and sintered. Their fracture resistance was analyzed by dynamic loading. For each zirconia blank, the fracture resistance of the sintered test restoration (cementation surface treated with BruxZir SteelTM) was compared with the sintered control restoration (untreated cementation surface). Finite Element Analysis (FEA) was used to analyze the stress distribution on the three-unit bridge under an axial load. RESULTS: The fracture resistance of the test restorations was significantly higher than that of the control restorations for all the manufacturers considered in this study (P < 0.05). Furthermore, the restoration made of BruxZirⓇ Esthetic treated with BruxZir SteelTM had the highest fracture resistance compared to the other restorations. In addition, the three-unit bridge restorations prepared from 5Y-PSZ-based zirconia blocks exhibited differences in grain size and fracture toughness depending on the presence or absence of BruxZir SteelTM treatment. The locations of high stresses under FEA correlated well with the fracture locations in the corresponding experimental test. FEA also demonstrated the improved performance of BruxZir Steel-treated sample compared to the control. SIGNIFICANCE: The fracture resistance of 5Y-PSZ-based BruxZir SteelTM-treated three-unit bridges was significantly higher (min. 30%, max. 198%) than control.

2.
Int J Prosthodont ; 0(0): 0, 2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37847788

RESUMO

PURPOSE: This study aims to evaluate the effect of different finishing protocols on the wear behavior of a lithium disilicate glass-ceramic. MATERIAL AND METHODS: Specimens were produced from lithium disilicate glass-ceramic prefabricated CAD/CAM blocks and divided into three groups, according to the surface treatment (n = 8): control; polishing; glaze. Ceramic specimens were subjected to wear test using a dual-axis chewing simulator. A 49 N load was applied in the axial direction combined with a lateral movement (1 mm path) using a lithium disilicate glass-ceramic spherical piston for a total of 106 cycles. Qualitative analysis of the wear surface was performed using an optical microscope. Quantitative analysis of surface roughness and volume loss was performed using a confocal microscope and a 3D-image editing software, respectively. Surface roughness and volume loss data were analyzed using Friedman's non-parametric statistical test for repeated measures and the Student-Newman-Keuls test (α = 0.050). RESULTS: There were statistical differences for surface roughness and volume loss of lithium disilicate glass-ceramic specimens in the different experimental conditions (P˂0.001). Control and polishing groups showed similar surface roughness and volume loss values for all testing times. Glaze group had greater wear volume after 103, 104 and 105 cycles. After 106 cycles, surface roughness and volume loss were similar among groups. For the piston, surface roughness was similar over time and among groups. CONCLUSIONS: A distinct wear behavior was found for glazed glass-ceramic specimens in comparison to control and polished specimens. The end of the simulation, the surface roughness and volume loss was similar for the groups.

3.
Artigo em Inglês | MEDLINE | ID: mdl-36851985

RESUMO

Background: To evaluate the effect of bone remodelling around a reduced-diameter dental implant on its fatigue limit using finite element analysis (FEA). Methods: A dental implant assembly, which included a reduced-diameter dental implant (Biomet-3i external hex), an abutment (GingiHue®) and a connector screw (Gold-Tite Square screw), was scanned using micro-computed tomography (Skyscan 1172). Its dimensions were measured using Mimics (Materialise) and an optical microscope (Keyence). The digital replicas of the physical specimens were constructed using SOLIDWORKS (Dassault Systems). A cylindrical bone specimen holder with two layers (cortical and cancellous bone) was designed in SOLIDWORKS. Two assemblies were created: (a) Model 1: Having non-remodelled bone; (b) Model 2: Cancellous bone remodelled at the regions adjacent to the implant screw threads. FEA was performed in ABAQUS (SIMULIA). In Model 1, the Young's modulus of cortical and cancellous bone were 20 GPa and 14 GPa, respectively. For Model 2, the region of the cancellous bone adjacent to the implant screw threads was assigned a Young's modulus of 20 GPa. fe-safe (SIMULIA) was used to estimate the fatigue limit. Results: The maximum von Mises stress under 100 N load was 439.9 MPa for both models 1 and 2 and was located at the connector screw. The fatigue limit was 116.4 N for both models 1 and 2. Conclusions: The results suggest that implant fatigue resistance tested according to ISO 14801 may be accurately predicted without bothering to simulate the non-homogeneous stiffness that occurs at the bone-implant interface in the clinical case.

4.
Artigo em Inglês | MEDLINE | ID: mdl-36704641

RESUMO

Background: This study aimed to investigate how the predicted implant fatigue lifetime is affected by the loss of connector screw preload and the finite element analysis method used to simulate preload. Methods: A dental implant assembly (DI1, Biomet-3i external hex; Zimmer Biomet) was scanned using microcomputed tomography and measured using Mimics software (Materialise) and an optical microscope. Digital replicas were constructed using SolidWorks software (Dassault Systèmes). The material properties were assigned in Abaqus (Dassault Systèmes). An external load was applied at 30° off-axial loading. Eight levels of connector screw preload (range, 0-32 Ncm) were simulated for DI1. This assembly and an additional model (DI2) having a longer and narrower screw were compared regarding their fatigue limits (using fe-safe software [Dassault Systèmes]) for 2 preloading methods: (1) adding preload torque or (2) adding bolt axial tension. Results: The maximum von Mises stresses of DI1 (on the connector screw threads) with and without preload were 439.90 MPa and 587.90 MPa. The predicted fatigue limit was the same for preloads from 100% through 80% of the manufacturer's recommendation and dropped precipitously between 80% and 70% preload. Adding a preload torque on the screw resulted in a more uniform stress distribution on the screw compared with bolt axial tension, especially for DI2, which had a longer and narrower screw than DI1. Conclusions: A substantial loss of preload can be accommodated without compromising the fatigue resistance of this dental implant. Computer models should be constructed using torque instead of a bolt axial tension.

5.
Artigo em Inglês | MEDLINE | ID: mdl-36970249

RESUMO

Background: Poly lactic-co-glycolic acid (PLGA) has been widely investigated for various biomedical applications, such as craniofacial bone regeneration, wound dressing and tissue engineering. Electrospinning is a versatile technology used to produce micro/nanoscale fibers with large specific surface area and high porosity. Purpose: The aim of the current study is to prepare PLGA nanofibers using electrospinning for guided tissue regeneration/guided bone regeneration applications. The objective of this study is to determine the appropriate electrospinning parameters such as applied voltage, flow rate, spinneret-collector distance and polymer solution concentration for preparation of PLGA fibrous membrane and their effect on the mean fiber diameter of the electrospun fibers. Method: PLGA pellets were dissolved in Hexafluoroisopropanol (HFIP) in various concentrations overnight using a bench rocker. The resulting PLGA solution was then loaded into a syringe and electrospinning was done by maintaining the other parameters constant. Similarly, various fibrous mats were collected by altering the specific electrospinning parameter inputs such as applied voltage, flow rate and spinneret-collector distance. The morphology of the fibrous mats was characterized using Scanning Electron Microscope. The mean fiber diameter was assessed using ImageJ software and the results were compared using one-way ANOVA. Results: We obtained bead-free uniform fibers with various tested solution concentrations. One-way ANOVA analysis demonstrated significant variation in mean fiber diameter of the electrospun fibers with altering applied voltage, solution concentration, flow rate and spinneret-collector distance. Conclusion: The above-mentioned electrospinning parameters and solution concentration influence the mean fiber diameter of electrospun PLGA nanofibers.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...