Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Arthroplasty ; 35(8): 2114-2118, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32331802

RESUMO

BACKGROUND: Currently, no consensus exists for selection criteria of appropriate candidates for outpatient total hip arthroplasty (THA). This study evaluates patient characteristics associated with same-day discharge, examined surgical start time's effect on rates of same-day discharge, and compares readmission and reoperation rates between groups. METHODS: All patients who underwent a THA by one surgeon at a single quaternary care hospital between February 2016 and May 2018 were captured. All patients were given the option for same-day discharge. Patient characteristics and perioperative variables were analyzed. RESULTS: A total of 429 patients met inclusion criteria, 153 (36%) were discharged on the day of surgery. In a multivariate analysis, age (P = .000), multiple comorbidities (P = .004), and start time remained statistically significant (P = .000). Patients with start times prior to 9 AM had odds ratio of 11.56 of being discharged same day when compared to those with start times after 12 PM. Patients discharged the day of surgery were less likely to have a 90-day emergency room visit (P = .010), a readmission within 30 days (P = .001) or 90 days (P = .000), or a reoperation (0 vs 14, P = .003). CONCLUSION: Same-day discharge following THA is safe and feasible. Patient's age and number of comorbidities should be considered when developing selection criteria for same-day discharge programs. Patients selected for same-day discharge should receive earlier operating room start times.


Assuntos
Artroplastia de Quadril , Humanos , Tempo de Internação , Alta do Paciente , Readmissão do Paciente , Complicações Pós-Operatórias , Fatores de Risco
2.
J Arthroplasty ; 30(11): 1971-5, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26067707

RESUMO

Persistent pain following hip arthroplasty remains a concern, especially in young, active patients. Four hundred twenty patients less than 60 years of age with a pre-symptomatic UCLA score ≥ 6 (196 total hip arthroplasty [THA]; 224 surface replacement arthroplasty [SRA]) completed a pain-drawing questionnaire investigating the location, severity, and frequency of pain around the hip. At a mean of 2.9 years of follow-up, 40% reported pain in at least one location around the hip. There was no difference in the incidence of groin pain between SRA and THA patients (32% vs. 29%, P=0.6), but THA patients had a greater incidence of anterior (25% vs. 8%, P<0.001) and lateral (20% vs. 10%, P=0.01) thigh pain. A high percentage of young, active patients experience persistent pain following hip arthroplasty.


Assuntos
Artroplastia de Quadril/efeitos adversos , Dor Pós-Operatória/epidemiologia , Adulto , Great Lakes Region/epidemiologia , Humanos , Incidência , Pessoa de Meia-Idade , Missouri/epidemiologia , Medição da Dor , Dor Pós-Operatória/etiologia , Estudos Prospectivos , Inquéritos e Questionários
3.
J Arthroplasty ; 30(3): 495-501, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25456636

RESUMO

Pain following total hip arthroplasty (THA) and surface arthroplasty (SRA) remains a significant source of patient dissatisfaction. Two hundred twenty-four SRA and 196 THA patients completed a pain drawing questionnaire and postoperative radiographic measurements of component positioning were performed. In the SRA cohort, 11 of 21 patients (52%) with acetabular uncoverage of ≥5 mm versus 43 of 147 (29%) with acetabular uncoverage of ≤4.9 mm reported groin pain (P=.03). In the THA cohort, an increased distal-third canal fill ratio and a lower canal calcar ratio trended towards a higher incidence of thigh pain (P=.10 and .06), while a decreased mid-third canal fill ratio was associated with increased severity of thigh pain (P=.04). This study identifies associations between radiographic findings and pain following THA and SRA.


Assuntos
Acetábulo/diagnóstico por imagem , Artroplastia de Quadril/efeitos adversos , Fêmur/diagnóstico por imagem , Articulação do Quadril/diagnóstico por imagem , Artropatias/diagnóstico por imagem , Dor Pós-Operatória/diagnóstico por imagem , Acetábulo/cirurgia , Adulto , Fêmur/cirurgia , Articulação do Quadril/cirurgia , Prótese de Quadril , Humanos , Artropatias/cirurgia , Dor Pós-Operatória/etiologia , Estudos Prospectivos , Radiografia , Inquéritos e Questionários
4.
J Arthroplasty ; 29(6): 1197-201, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24411081

RESUMO

The purpose of the present study is to retrospectively analyze clinical and radiographic outcomes in primary constrained condylar knee arthroplasty at a minimum follow-up of 7 years. Given the concern for early aseptic loosening in constrained implants, we focused on this outcome. Our cohort consists of 127 constrained condylar knees. The mean age of patients in the study was 68.3 years, with a mean follow-up of 110.7 months. The diagnosis was primary osteoarthritis in 92%. There were four periprosthetic distal femur fractures, with a rate of revision of 0.8%. No implants were revised for aseptic loosening. Kaplan-Meier survivorship analysis with removal of any component as the end point revealed that the 10-year rate of survival of the primary CCK was 97.6% (95% CI, 94%-100%).


Assuntos
Artroplastia do Joelho/métodos , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Idoso , Artroplastia do Joelho/efeitos adversos , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Fraturas Periprotéticas/etiologia , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Resultado do Tratamento
5.
J Arthroplasty ; 28(1): 196.e7-9, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22658428

RESUMO

The use of modular femoral stems in primary total hip arthroplasty has increased considerably in recent years. These modular components offer the surgeon the ability to independently alter version, offset, and length of the femoral component of a hip arthroplasty. This increases the surgeon's ability to accurately recreate the relevant anatomy but increases the possibilities of corrosion and fracture. Multiple case reports have highlighted fractures of these modular components. We present a case of a fracture of a modular design that has had no previously reported modular neck fractures. The patient was informed that data concerning the case would be submitted, and he consented.


Assuntos
Artroplastia de Quadril , Prótese de Quadril/efeitos adversos , Falha de Prótese , Articulação do Quadril/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Radiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...