Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 240
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38668934

RESUMO

BACKGROUND: Left bundle branch area pacing (LBBAP) has emerged as a physiological alternative pacing strategy to biventricular pacing (BIVP) in cardiac resynchronization therapy (CRT). We aimed to assess the impact of LBBAP vs. BIVP on all-cause mortality and heart failure (HF)-related hospitalization in patients undergoing CRT. METHODS: Studies comparing LBBAP and BIVP for CRT in patients with HF with reduced left ventricular ejection fraction (LVEF) were included. The coprimary outcomes were all-cause mortality and HF-related hospitalization. Secondary outcomes included procedural and fluoroscopy time, change in QRS duration, and change in LVEF. RESULTS: Thirteen studies (12 observational and 1 RCT, n = 3239; LBBAP = 1338 and BIVP = 1901) with a mean follow-up duration of 25.8 months were included. Compared to BIVP, LBBAP was associated with a significant absolute risk reduction of 3.2% in all-cause mortality (9.3% vs 12.5%, RR 0.7, 95% CI 0.57-0.86, p < 0.001) and an 8.2% reduction in HF-related hospitalization (11.3% vs 19.5%, RR 0.6, 95% CI 0.5-0.71, p < 0.00001). LBBAP also resulted in reductions in procedural time (mean weighted difference- 23.2 min, 95% CI - 42.9 to - 3.6, p = 0.02) and fluoroscopy time (- 8.6 min, 95% CI - 12.5 to - 4.7, p < 0.001) as well as a significant reduction in QRS duration (mean weighted difference:- 25.3 ms, 95% CI - 30.9 to - 19.8, p < 0.00001) and a greater improvement in LVEF of 5.1% (95% CI 4.4-5.8, p < 0.001) compared to BIVP in the studies that reported these outcomes. CONCLUSION: In this meta-analysis, LBBAP was associated with a significant reduction in all-cause mortality as well as HF-related hospitalization when compared to BIVP. Additional data from large RCTs is warranted to corroborate these promising findings.

3.
J Innov Card Rhythm Manag ; 15(3): 5803-5804, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38584750
4.
Artigo em Inglês | MEDLINE | ID: mdl-38499825

RESUMO

BACKGROUND: Cardioneuroablation has been emerging as a potential treatment alternative in appropriately selected patients with cardioinhibitory vasovagal syncope (VVS) and functional AV block (AVB). However the majority of available evidence has been derived from retrospective cohort studies performed by experienced operators. METHODS: The Cardioneuroablation for the Management of Patients with Recurrent Vasovagal Syncope and Symptomatic Bradyarrhythmias (CNA-FWRD) Registry is a multicenter prospective registry with cross-over design evaluating acute and long-term outcomes of VVS and AVB patients treated by conservative therapy and CNA. RESULTS: The study is a prospective observational registry with cross-over design for analysis of outcomes between a control group (i.e., behavioral and medical therapy only) and intervention group (Cardioneuroablation). Primary and secondary outcomes will only be assessed after enrollment in the registry. The follow-up period will be 3 years after enrollment. CONCLUSIONS: There remains a lack of prospective multicentered data for long-term outcomes comparing conservative therapy to radiofrequency CNA procedures particularly for key outcomes including recurrence of syncope, AV block, durable impact of disruption of the autonomic nervous system, and long-term complications after CNA. The CNA-FWRD registry has the potential to help fill this information gap.

6.
Heart Rhythm O2 ; 5(1): 24-33, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38312200

RESUMO

Background: Catheter ablation of premature ventricular complexes (PVCs) and ventricular tachycardia (VT) from the left ventricular summit (LVS) may require advanced ablation techniques. Bipolar ablation from the coronary veins and adjacent endocardial structures can be effective for refractory LVS arrhythmias. Objective: The aim of this study was to investigate the outcomes of bipolar ablation performed between the coronary venous system and adjacent endocardial left ventricular outflow tract (LVOT) or right ventricular outflow tract (RVOT). Methods: This multicenter study included consecutive patients with LVS PVC/VT who underwent bipolar ablation between the anterior interventricular vein (AIV) or great cardiac vein (GCV) and the endocardial LVOT/RVOT after failed unipolar ablation. Ablation was started with powers of 10-20 W and uptitrated to achieve an impedance drop of at least 10%. Angiography was performed in all cases to confirm a safe distance (>5 mm) of the catheter from the major coronary arteries. Results: Between 2013 and 2023, bipolar radiofrequency ablation between the AIV/GCV and the adjacent LVOT/RVOT was attempted in 20 patients (4 female; age 57 ± 16 years). Unipolar ablation from sites of early activation (AIV/GCV, LVOT, aortic cusps, RVOT) failed to effectively suppress the PVC/VT in all subjects. Bipolar ablation was delivered with a maximum power of 30 ± 8 W and total duration of 238 ± 217 s and led to acute PVC/VT elimination in all patients. No procedural-related complications occurred. Over a follow-up period of 30 ± 24 months, the freedom from arrhythmia recurrence was 85% (1 recurrence in the VT group and 2 in the PVC group). PVC burden was reduced from 22% ± 10% to 4% ± 8% (P <.001). Conclusion: In cases of LVS PVC/VT refractory to unipolar ablation, bipolar ablation between the coronary venous system and adjacent endocardial LVOT/RVOT is safe and effective if careful titration of power and intraprocedural angiography are performed to ensure a safe distance from the coronary arteries.

8.
Br J Anaesth ; 132(4): 779-788, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38087741

RESUMO

BACKGROUND: We investigated the effects of ketamine on desaturation and the risk of nursing home discharge in patients undergoing procedural sedation by anaesthetists. METHODS: We included adult patients who underwent procedures under monitored anaesthetic care between 2005 and 2021 at two academic healthcare networks in the USA. The primary outcome was intraprocedural oxygen desaturation, defined as oxygen saturation <90% for ≥2 consecutive minutes. The co-primary outcome was a nursing home discharge. RESULTS: Among 234,170 included patients undergoing procedural sedation, intraprocedural desaturation occurred in 5.6% of patients who received ketamine vs 5.2% of patients who did not receive ketamine (adjusted odds ratio [ORadj] 1.22, 95% confidence interval [CI] 1.15-1.29, P<0.001; adjusted absolute risk difference [ARDadj] 1%, 95% CI 0.7-1.3%, P<0.001). The effect was magnified by age >65 yr, smoking, or preprocedural ICU admission (P-for-interaction <0.001, ORadj 1.35, 95% CI 1.25-1.45, P<0.001; ARDadj 2%, 95% CI 1.56-2.49%, P<0.001), procedural risk factors (upper endoscopy of longer than 2 h; P-for-interaction <0.001, ORadj 2.91, 95% CI 1.85-4.58, P<0.001; ARDadj 16.2%, 95% CI 9.8-22.5%, P<0.001), and high ketamine dose (P-for-trend <0.001, ORadj 1.61, 95% CI, 1.43-1.81 for ketamine >0.5 mg kg-1). Concomitant opioid administration mitigated the risk (P-for-interaction <0.001). Ketamine was associated with higher odds of nursing home discharge (ORadj 1.11, 95% CI 1.02-1.21, P=0.012; ARDadj 0.25%, 95% CI 0.05-0.46%, P=0.014). CONCLUSIONS: Ketamine use for procedural sedation was associated with an increased risk of oxygen desaturation and discharge to a nursing home. The effect was dose-dependent and magnified in subgroups of vulnerable patients.


Assuntos
Ketamina , Adulto , Humanos , Ketamina/efeitos adversos , Estudos Retrospectivos , Hospitais , Sistema de Registros , Serviço Hospitalar de Emergência , Oxigênio , Atenção à Saúde , Aceitação pelo Paciente de Cuidados de Saúde , Sedação Consciente/métodos , Hipnóticos e Sedativos
9.
J Cardiovasc Electrophysiol ; 35(1): 44-57, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37927196

RESUMO

BACKGROUND: Intracardiac echocardiography (ICE) is increasingly used during left atrial appendage occlusion (LAAO) as an alternative to transesophageal echocardiography (TEE). The objective of this study is to evaluate the impact of ICE versus TEE guidance during LAAO on procedural characteristics and acute outcomes, as well the presence of peri-device leaks and residual septal defects during follow-up. METHODS: All studies comparing ICE-guided versus TEE-guided LAAO were identified. The primary outcomes were procedural efficacy and occurrence of procedure-related complications. Secondary outcomes included lab efficiency (defined as a reduction in in-room time), procedural time, fluoroscopy time, and presence of peri-device leaks and residual interatrial septal defects (IASD) during follow-up. RESULTS: Twelve studies (n = 5637) were included. There were no differences in procedural success (98.3% vs. 97.8%; OR 0.73, 95% CI 0.42-1.27, p = .27; I2 = 0%) or adverse events (4.5% vs. 4.4%; OR 0.81 95% CI 0.56-1.16, p = .25; I2 = 0%) between the ICE-guided and TEE-guided groups. ICE guidance reduced in in-room time (mean-weighted 28.6-min reduction in in-room time) without differences in procedural time or fluoroscopy time. There were no differences in peri-device leak (OR 0.93, 95% CI 0.68-1.27, p = 0.64); however, an increased prevalence of residual IASD was observed with ICE-guided versus TEE-guided LAAO (46.3% vs. 34.2%; OR 2.23, 95% CI 1.05-4.75, p = 0.04). CONCLUSION: ICE guidance is associated with similar procedural efficacy and safety, but could result in improved lab efficiency (as established by a significant reduction in in-room time). No differences in the rate of periprocedural leaks were found. A higher prevalence of residual interatrial septal defects was observed with ICE guidance.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Ecocardiografia Transesofagiana , Resultado do Tratamento
10.
JACC Clin Electrophysiol ; 10(2): 295-305, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38127008

RESUMO

BACKGROUND: Left bundle branch pacing (LBBP) and left ventricular septal pacing (LVSP) are considered to be acceptable as LBBAP strategies. Differences in clinical outcomes between LBBP and LVSP are yet to be determined. OBJECTIVES: The purpose of this study was to compare the outcomes of LBBP vs LVSP vs BIVP for CRT. METHODS: In this prospective multicenter observational study, LBBP was compared with LVSP and BIVP in patients undergoing CRT. The primary composite outcome was freedom from heart failure (HF)-related hospitalization and all-cause mortality. Secondary outcomes included individual components of the primary outcome, postprocedural NYHA functional class, and electrocardiographic and echocardiographic parameters. RESULTS: A total of 415 patients were included (LBBP: n = 141; LVSP: n = 31; BIVP: n = 243), with a median follow-up of 399 days (Q1-Q3: 249.5-554.8 days). Freedom from the primary composite outcomes was 76.6% in the LBBP group and 48.4% in the LVSP group (HR: 1.37; 95% CI: 1.143-1.649; P = 0.001), driven by a 31.4% absolute increase in freedom from HF-related hospitalizations (83% vs 51.6%; HR: 3.55; 95% CI: 1.856-6.791; P < 0.001) without differences in all-cause mortality. LBBP was also associated with a higher freedom from the primary composite outcome compared with BIVP (HR: 1.43; 95% CI: 1.175-1.730; P < 0.001), with no difference between LVSP and BIVP. CONCLUSIONS: In patients undergoing CRT, LBBP was associated with improved outcomes compared with LVSP and BIVP, while outcomes between BIVP and LVSP are similar.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Estudos Prospectivos , Sistema de Condução Cardíaco , Ventrículos do Coração , Eletrocardiografia
13.
JACC Clin Electrophysiol ; 9(12): 2573-2583, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37804258

RESUMO

BACKGROUND: High-power short-duration (HPSD) radiofrequency ablation of atrial fibrillation (AF) increases first-pass pulmonary vein isolation (PVI) and freedom from atrial arrhythmias while decreasing procedural time. However, the optimal power setting in terms of safety and efficacy has not been determined. OBJECTIVES: This study compared the procedural characteristics and clinical outcomes of 50-W vs 40-W during HPSD ablation of paroxysmal AF. METHODS: Patients from the REAL-AF prospective multicenter registry (Real-World Experience of Catheter Ablation for Treatment of Symptomatic Paroxysmal and Persistent Atrial Fibrillation) undergoing HPSD ablation of paroxysmal AF, either using 50-W or 40-W, were included. The primary efficacy outcome was freedom from all-atrial arrhythmias. The primary safety outcome was the occurrence of any procedural complication at 12 months. Secondary outcomes included procedural characteristics, AF-related symptoms, and the occurrence of transient ischemic attack or stroke at 12 months. RESULTS: A total of 383 patients were included. Freedom from all-atrial arrhythmias at 12 months was 80.7% in the 50-W group and 77.3% in the 40-W group (Log-rank P = 0.387). The primary safety outcome occurred in 3.7% of patients in the 50-W group vs 2.8% in the 40-W group (P = 0.646). The 50-W group had a higher rate of first-pass PVI (82.3% vs 76.2%; P = 0.040) as well as shorter procedural (67 minutes [IQR: 54-87.5 minutes] vs 93 minutes [IQR: 80.5-111 minutes]; P < 0.001) and radiofrequency ablation times (15 minutes [IQR: 11.4-20 minutes] vs 27 minutes [IQR: 21.5-34.6 minutes]; P < 0.001) than the 40-W group. CONCLUSIONS: There was no significant difference in freedom from all-atrial arrhythmias or procedural safety outcomes between 50-W and 40-W during HPSD ablation of paroxysmal AF. The use of 50-W was associated with a higher rate of first-pass PVI as well as shorter procedural times.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Humanos , Estudos Prospectivos , Recidiva Local de Neoplasia/etiologia , Fatores de Tempo , Ablação por Cateter/efeitos adversos
14.
J Subst Use Addict Treat ; 155: 209176, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37778703

RESUMO

INTRODUCTION: Buprenorphine is highly effective for the treatment of opioid use disorder (OUD), and, in recent years, the rates of patients maintained on buprenorphine requiring critical care have been steadily increasing. Currently, no unified guidance exists for buprenorphine management during critical illness. Likewise, we do not know if patients maintained on buprenorphine for OUD are prescribed medications for OUD (MOUD) following hospital discharge or if buprenorphine management influences mu opioid agonist dispensing. METHODS: In our cohort of adults over the age of 18 with OUD, receiving buprenorphine formulations in the 3 months preceding their ICU admission, we sought to investigate the relationship between receipt of MOUD and non-MOUD opioid prescribing up to 12 months following hospital discharge. This was a single-center, retrospective cohort study approved by the MaineHealth institutional review board. The study analyzed differences in prescription rates between discharge and subsequent time points using chi square or Fisher's exact test, as appropriate. We performed analyses using SPSS Statistical Software version 28 (IBM SPSS Inc., Armonk, NY) with significance set at p < 0.05. RESULTS: We identified a statistically significant increase in MOUD prescribing 3 months posthospital discharge in patients who received MOUD at time of discharge (87.9 % vs 40 % p = 0.002.) The study found a significant increase in nonbuprenorphine opioid prescribing in patients who did not receive an MOUD prescription at time of discharge (24.2 % vs 70 % p = 0.007). This trend persisted at the 6-month and 12-month time points; however, it did not reach statistical significance. Additionally, the study identified a significant reduction in the incidence of non-MOUD opioid dispensing in patients prescribed MOUD at each time point measured (p = 0.007, p < 0.001. p < 0.001 and p = 0.008 at discharge, 3, 6, and 12 months, respectively). CONCLUSIONS: These findings support continuing buprenorphine dispensing following hospital discharge.


Assuntos
Buprenorfina , Transtornos Relacionados ao Uso de Opioides , Adulto , Humanos , Pessoa de Meia-Idade , Analgésicos Opioides/uso terapêutico , Alta do Paciente , Estudos Retrospectivos , Padrões de Prática Médica , Transtornos Relacionados ao Uso de Opioides/tratamento farmacológico , Buprenorfina/uso terapêutico , Cuidados Críticos , Hospitais
16.
JACC Clin Electrophysiol ; 9(11): 2342-2346, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37737777

RESUMO

The authors describe 3 patients presenting with cardiac sarcoidosis (CS) flare and ventricular tachycardia (VT) storm following infection with severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2), the causative agent of COVID-19. COVID-19-related cardiac manifestations can vary and include arrythmias, myocarditis, and exacerbation of underlying cardiovascular disease. The exact mechanism of myocardial involvement is not clear but may include abnormal host immune response and direct myocardial injury, thereby predisposing to enhanced arrhythmic risk. Arrhythmias account for 20% of COVID-19-related complications with ventricular arrythmias occurring in 5.9% of cases. Further studies are needed to better understand mechanisms underlying the intersection between COVID-19 infection and inflammatory cardiomyopathies.


Assuntos
COVID-19 , Cardiomiopatias , Miocardite , Sarcoidose , Taquicardia Ventricular , Humanos , COVID-19/complicações , Cardiomiopatias/complicações , SARS-CoV-2 , Sarcoidose/complicações , Arritmias Cardíacas/complicações
17.
Heart Rhythm ; 20(12): 1674-1681, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37598986

RESUMO

BACKGROUND: Infection is the most dreaded complication of cardiac implantable electronic devices (CIEDs), particularly in patients undergoing high-risk procedures (eg, generator change, device upgrade, lead/pocket revision). OBJECTIVE: The purpose of this study was to describe the impact of chlorhexidine gluconate (CHG) pocket lavage in high-risk procedures. METHODS: Patients from a prospective multicenter registry undergoing high-risk procedures were included. CHG lavage was performed by irrigating the generator pocket with 20 cc of 2% CHG without alcohol followed by and normal saline (NS) irrigation. Only NS irrigation was performed in the comparison group. The primary efficacy outcome was CIED-related infection at 12 months. The primary safety outcome was any CHG-associated adverse event. The secondary outcome was CIED infection during long-term follow-up. Propensity score matching (PSM) analysis was performed for the primary efficacy outcome. RESULTS: A total of 1504 patients were included. At 12-month follow-up, the primary efficacy outcome occurred in 4 of 904 CHG (0.4%) and 14 of 600 NS (2.3%) subjects (log-rank P = .005). On multivariate analysis, the use of CHG irrigation was associated with a lower risk of infection at 1-year follow-up (Cox proportional hazard ratio [HR] 0.138; 95% confidence interval [CI] 0.04-0.45; P = .001). This effect persisted during long-term follow-up. PSM demonstrated a significant reduction in CIED-related infection for the CHG group (0.2% vs 2.5%; Cox proportional HR 0.08; 95% CI 0.01-0.59; P = .014). No adverse events were associated with the use of CHG. CONCLUSION: CHG lavage during high-risk procedures was associated with a reduction in CIED-related infections without any adverse events reported. The benefits of CHG lavage were observed even during long-term follow up and in PSM analysis.


Assuntos
Desfibriladores Implantáveis , Cardiopatias , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Humanos , Desfibriladores Implantáveis/efeitos adversos , Cardiopatias/etiologia , Marca-Passo Artificial/efeitos adversos , Estudos Prospectivos , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/prevenção & controle , Irrigação Terapêutica
19.
JACC Clin Electrophysiol ; 9(8 Pt 2): 1487-1499, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37486280

RESUMO

BACKGROUND: Epicardial access (EA) has emerged as an increasingly important approach for the treatment of ventricular arrhythmias and to perform other interventional cardiology procedures. EA is frequently underutilized because the current approach is challenging and carries a high risk of life-threatening complications. OBJECTIVE: The purpose of this study was to determine the efficacy and safety of the SAFER (Sustained Apnea for Epicardial Access With Right Ventriculography) epicardial approach. METHODS: Consecutive patients who underwent EA with the SAFER technique were included in this multicenter study. The primary efficacy outcome was the successful achievement of EA. The primary safety outcomes included right ventricular (RV) perforation, major hemorrhagic pericardial effusion (HPE), and bleeding requiring surgical intervention. Secondary outcomes included procedural characteristics and any complications. Our results were compared with those from previous studies describing other EA techniques to assess differences in outcomes. RESULTS: A total of 105 patients undergoing EA with the SAFER approach from June 2021 to February 2023 were included. EA was used for ventricular tachycardia ablation in 98 patients (93.4%), left atrial appendage closure in 6 patients (5.7%), and phrenic nerve displacement in 1 patient (0.9%). EA was successful in all subjects (100%). The median time to EA was 7 minutes (IQR: 5-14 minutes). No cases of RV perforation, HPE, or need of surgical intervention were observed in this cohort. Comparing our results with previous studies about EA, the SAFER epicardial approach resulted in a significant reduction in major pericardial bleeding. CONCLUSIONS: The SAFER epicardial approach is a simple, efficient, effective, and low-cost technique easily reproducible across multiple centers. It is associated with lower complication rates than previously reported techniques for EA.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Traumatismos Cardíacos , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/cirurgia , Apneia , Arritmias Cardíacas , Pericárdio/diagnóstico por imagem , Pericárdio/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Hemorragia
20.
JACC Clin Electrophysiol ; 9(8 Pt 1): 1404-1408, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37227346

RESUMO

The authors sought to evaluate a method for improving radiofrequency (RF) lesion durability using doxorubicin encased in heat-sensitive liposomes (HSL-dox). Using a porcine model, RF ablations were performed in the right atrium after systemic infusion of either HSL-dox or saline control given immediately before mapping and ablation. Lesion geometry was measured with voltage mapping immediately postablation and after 2 weeks of survival. After 2 weeks, lesions demonstrated less regression in scar area in HSL-dox-exposed animals compared with control animals. We demonstrate improved RF lesion durability in animals treated with HSL-dox, and the cardiotoxic effect was more pronounced after RF applications with higher power and longer duration.


Assuntos
Temperatura Alta , Lipossomos , Suínos , Animais , Miocárdio , Doxorrubicina/uso terapêutico , Átrios do Coração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...