Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
4.
J Nucl Cardiol ; 29(4): 1647-1656, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-33988809

RESUMO

AIMS: The objective of this study was to determine the accuracy of right ventricular function (RVF) assessed by Cadmium Zinc Telluride ECG-gated SPECT equilibrium radionuclide angiocardiography (CZT-ERNA). METHODS AND RESULTS: Twenty-one consecutive patients with cardiomyopathy (aged 54 ± 19 years; 62% male) were included. RV ejection fraction (EF) and volumes were analyzed by CZT-ERNA and compared with values obtained by cardiac magnetic resonance imaging (CMR). Mean values were not different between CZT-ERNA and MRI for RVEF (48.1 ± 10.4% vs 50.8 ± 10.0%; P = .23). Significant correlations (P < .0001) were observed between CZT-ERNA and MRI for RVEF, RV end-diastolic volume, and end-systolic volume (r = 0.81, r = 0.93, and r = 0.96, respectively). Bland-Altman analysis showed a mean difference (bias) between CZT-ERNA and MRI for RVEF of -2.69% (95% CI - 5.35 to - 0.42) with good agreement between the 2 techniques (limits of agreement, -14.3 to 8.99). Intraobserver and interobserver reproducibility of RVF measured by CZT-ERNA was high. CONCLUSION: CZT-ERNA provides accurate, reproducible assessment of RVF and appears as a good alternative to cardiac magnetic resonance for the evaluation of the magnitude of RVF in patients with cardiomyopathy.


Assuntos
Cardiomiopatias , Imagem do Acúmulo Cardíaco de Comporta , Cádmio , Cardiomiopatias/diagnóstico por imagem , Eletrocardiografia , Feminino , Imagem do Acúmulo Cardíaco de Comporta/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Reprodutibilidade dos Testes , Volume Sistólico , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Zinco
5.
Chest ; 160(2): e165-e167, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34366037

RESUMO

Severe pulmonary edema, secondary to left ventricular afterload increment, is a common problem occurring in patients receiving venoarterial extracorporeal membrane oxygenation. No consensus is currently available for its management, but several devices/procedures have been described, including an Impella device (Abiomed), balloon atrial septostomy, intraaortic balloon counterpulsation, or an additional venous cannula, as possible adjuncts. We report the feasibility and efficacy of the atrial flow regulator device (Occlutech) for left ventricular unloading in a 58-year-old patient receiving extracorporeal membrane oxygenation. However, the benefits of this device relative to simple balloon atrial septostomy need to be further investigated.


Assuntos
Oxigenação por Membrana Extracorpórea/efeitos adversos , Átrios do Coração , Edema Pulmonar/etiologia , Dispositivo para Oclusão Septal , Choque Cardiogênico/terapia , Velocidade do Fluxo Sanguíneo , Remoção de Dispositivo , Coração Auxiliar , Humanos , Masculino , Pessoa de Meia-Idade
6.
JACC Case Rep ; 3(6): 966-970, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34317667

RESUMO

A 52-year-old man with acute peritonitis developed severely decreased left ventricular (LV) ejection fraction. Multimodal imaging allowed the diagnosis of sepsis-related myocardial calcification. Moreover, 2-dimensional speckle tracking echocardiography allowed a better understanding of LV dysfunction and confirmed the hypothesis that regional LV dysfunction is in accordance with the localization of calcifications. (Level of Difficulty: Intermediate.).

7.
J Clin Med ; 10(10)2021 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-34070034

RESUMO

BACKGROUND: Atherosclerosis is associated with a worse prognosis in many diseases such as ischemic cardiomyopathy, but its impact in non-ischemic dilated cardiomyopathy (dCMP) is lesser known. Our aim was to study the prognostic impact of coronary atherosclerotic burden (CAB) in patients with dCMP. METHODS: Consecutive patients with dCMP and left ventricular (LV) dysfunction diagnosed by concomitant analysis of invasive coronary angiography (ICA) and CMR imaging were identified from registry-database. CAB was measured by Gensini score. The primary composite endpoint was the occurrence of major adverse cardiovascular events (MACE) defined as cardiovascular (CV) mortality, non-fatal MI and unplanned myocardial revascularization. The results of 139 patients constituting the prospective study population (mean age 59.4 ± 14.7 years old, 74% male), average LV ejection fraction was 31.1 ± 11.02%, median Gensini score was 0 (0-3), and mid-wall late gadolinium enhancement (LGE) was the most frequent LGE pattern (42%). Over a median follow-up of 2.8 years, 9% of patients presented MACE. Patients with MACE had significantly higher CAB compared to those who were free of events (0 (0-3) vs. 3.75 (2-15), p < 0.0001). CAB remained the significant predictor of MACE on multivariate logistic analysis (OR: 1.12, CI: 1.01-1.23, p = 0.02). CONCLUSION: High CAB may be a new prognostic factor in dCMP patients.

8.
Echocardiography ; 34(12): 1872-1881, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29114924

RESUMO

AIMS: Patients with significant (3+/4+) aortic regurgitation (AR) require careful monitoring or valve surgery. We sought to evaluate the diagnostic performance of aortic and pulmonary flow comparison in identifying patients with significant AR, by echocardiography. METHOD: Two hundred forty-six patients with more than trivial AR were prospectively enrolled from three centers. Aortic regurgitation (AR) severity was assessed by an expert using the currently recommended integrative approach. Aortic and pulmonary flows were independently assessed by another investigator to calculate the regurgitant fraction (RF), the aortic to pulmonary flow ratio (Qao/Qp) and the aortic to pulmonary velocity-time integral (VTIao/VTIp) ratio. The control group consisted of 195 patients without AR. RESULTS: A significant correlation was observed between AR grading and RF (r = .82, P < .0001) and Qao/Qp (r = .81, P < .0001), but the correlation was modest for VTIao/VTIp ratio (r = .63; P < .0001). The accuracy of RF and Qao/Qp ratio to identify patients with significant AR was excellent (0.96 and 0.95, respectively), but was significantly lower for VTIao/VTIp ratio at 0.82. A RF > 40% indicated grade 3 or 4 AR with a sensitivity of 83% and a specificity of 93%. A Qao/Qp ratio > 1.6 indicated grade 3 or 4 AR with a sensitivity of 88% and a specificity of 89%. The VTIao/VTIp ratio was not helpful in identifying patients with significant AR, as a wide overlap was found between 1+/2+ and 3+/4+ patients. CONCLUSION: Regurgitant fraction (RF) and Qao/Qp are helpful in identifying significant AR. The assessment of Doppler aortic/pulmonary flow should be incorporated in the comprehensive evaluation of AR.


Assuntos
Aorta/fisiopatologia , Insuficiência da Valva Aórtica/fisiopatologia , Ecocardiografia Doppler/métodos , Pulmão/irrigação sanguínea , Pulmão/fisiopatologia , Aorta/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Estudos de Avaliação como Assunto , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Índice de Gravidade de Doença
9.
Am J Cardiol ; 120(9): 1633-1638, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-28864319

RESUMO

Cardiac computed tomography (CT) provides additional information with ultrasound in the transcatheter heart valve (THV) size selection. However, the influence of these incremental data on outcomes has not been evaluated in a randomized study. A single-center prospective, randomized, and open study was performed. Patients referred for transfemoral transcatheter aortic valve implantation with a balloon-expandable endoprothesis were included. THV size selection was performed using either transthoracic and transesophageal echocardiography data (control group) or ultrasound and CT results (CT group). The primary composite end point included the occurrence of stroke, major vascular complications, and moderate or severe paravalvular aortic regurgitation (PAR) at 1 year. Fifty patients (n = 25 in the control and CT groups) were enrolled. The primary composite end point occurred in 40% and 8% of patients from the control and CT groups, respectively (p = 0.008). The Kaplan-Meier analysis revealed a pejorative association with not performing the CT (p = 0.007). A decrease in the occurrence of PAR was observed in the CT group compared with the control group (PAR 28% vs 4%, p = 0.04; major vascular complications 12% vs 4%, p = 0.6; all-cause death 16% vs. 4%, p = 0.34; no stroke). In conclusion, the use of cardiac CT in addition to ultrasound data in THV size selection reduced the long-term occurrence of cardiovascular events.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia Transesofagiana , Tomografia Computadorizada Multidetectores , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Intervalo Livre de Doença , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Estudos Prospectivos , Resultado do Tratamento
10.
Rev Infirm ; (193): 38-41, 2013.
Artigo em Francês | MEDLINE | ID: mdl-24245405

RESUMO

VO2 max is nowadays an essential examination performed in the monitoring of heart failure. The nurse has a role to play during the test and in supporting the patient, although this test remains highly technical and complex.


Assuntos
Teste de Esforço/enfermagem , Insuficiência Cardíaca/enfermagem , Oxigênio/sangue , Dispneia/sangue , Dispneia/etiologia , Desenho de Equipamento , Teste de Esforço/instrumentação , Teste de Esforço/métodos , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/diagnóstico , Humanos , Papel do Profissional de Enfermagem , Valor Preditivo dos Testes
11.
Eur Respir J ; 40(3): 673-80, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22523356

RESUMO

Altitude illness remains a major cause of mortality. Reduced chemosensitivity, irregular breathing leading to central apnoeas/hypopnoeas, and exaggerated pulmonary vasoconstriction may compromise oxygenation. All factors could enhance susceptibility to acute mountain sickness (AMS). We compared 12 AMS-susceptible individuals with recurrent and severe symptoms (AMS+) with 12 "AMS-nonsusceptible" subjects (AMS-), assessing sleep-breathing disorders in simulated altitude as well as chemoresponsive and pulmonary vasoconstrictive responses to hypoxia. During exposure to simulated altitude, mean blood oxygen saturation during sleep was lower in AMS+ subjects (81.6 ± 2.6 versus 86.0 ± 2.4%, p<0.01), associated with a lower central apnoea/hypopnoea index (18.2 ± 18.1 versus 33.4 ± 24.8 events · h(-1) in AMS+ and AMS- subjects, respectively; p=0.038). A lower hypoxic (isocapnic) chemoresponsiveness was observed in AMS+ subjects (0.40 ± 0.49 versus 0.97 ± 0.46 L · min(-1)·%; p<0.001). This represented the only significant and independent predictive factor for altitude intolerance, despite a higher increase in pulmonary artery systolic pressure in response to hypoxia, a lower lung diffusing capacity and a higher endothelin-1 level at baseline in AMS+ subjects (p<0.05). AMS+ subjects were more hypoxaemic whilst exhibiting fewer respiratory events during sleep owing to lower hypoxic (isocapnic) chemoresponsiveness. In conclusion, the reduction in peripheral hypoxic chemosensitivity appears to be a major causative factor for altitude intolerance.


Assuntos
Doença da Altitude/fisiopatologia , Hipóxia/fisiopatologia , Oxigênio/sangue , Sono/fisiologia , Doença Aguda , Adulto , Doença da Altitude/sangue , Apneia/sangue , Apneia/fisiopatologia , Endotelina-1/sangue , Feminino , Humanos , Hipóxia/sangue , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar/fisiopatologia , Capacidade de Difusão Pulmonar , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...