Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Eur Heart J ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747246

RESUMO

BACKGROUND AND AIMS: Transcatheter aortic valve implantation (TAVI) has become the first choice to treat older patients with severe symptomatic aortic stenosis (AS). This study aimed to compare TAVI with surgery in low-risk patients ≤ 75 years of age, including both tricuspid and bicuspid AS. METHODS: The NOTION-2 trial enrolled and 1:1 randomized low-risk patients aged ≤ 75 years with severe symptomatic AS to TAVI or surgery. The primary endpoint was a composite of all-cause mortality, stroke or rehospitalization (related to the procedure, valve or heart failure) at 12 months. RESULTS: A total of 370 patients were enrolled with a mean age of 71.1 years and a median Society of Thoracic Surgeons risk score of 1.1%. A total of 100 patients had bicuspid AS. The 1-year incidence of the primary endpoint was 10.2% in the TAVI group and 7.1% in the surgery group (absolute risk difference 3.1%; 95% confidence interval [CI], -2.7% to 8.8%; hazard ratio (HR) 1.4, 95% CI: 0.7 to 2.9; p=0.3). Patients with TAVI, when compared to surgery, had lower risk of major bleeding and new-onset atrial fibrillation and higher risk of non-disabling stroke, permanent pacemaker implantation and moderate-or-greater paravalvular regurgitation. The risk of the primary composite endpoint was 8.7% and 8.3% in patients with tricuspid AS (HR 1.0, 95% CI: 0.5 to 2.3) and 14.3% and 3.9% in patients with bicuspid AS (HR 3.8, 95% CI: 0.8 to 18.5) treated with TAVI or surgery, respectively (P for interaction=0.1). CONCLUSIONS: Among low-risk patients aged ≤ 75 years with severe symptomatic AS, the rate of the composite of death, stroke, or rehospitalization at one year was similar between TAVI and surgery. TAVI outcomes in young bicuspid AS patients warrant caution and should be further investigated. (NOTION-2, ClinicalTrials.gov, NCT02825134).

2.
JACC Cardiovasc Interv ; 17(3): 374-387, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38180419

RESUMO

BACKGROUND: The COVID-19 pandemic adversely affected health care systems. Patients in need of transcatheter aortic valve replacement (TAVR) are especially susceptible to treatment delays. OBJECTIVES: This study sought to evaluate the impact of the COVID-19 pandemic on global TAVR activity. METHODS: This international registry reported monthly TAVR case volume in participating institutions prior to and during the COVID-19 pandemic (January 2018 to December 2021). Hospital-level information on public vs private, urban vs rural, and TAVR volume was collected, as was country-level information on socioeconomic status, COVID-19 incidence, and governmental public health responses. RESULTS: We included 130 centers from 61 countries, including 65,980 TAVR procedures. The first and second pandemic waves were associated with a significant reduction of 15% (P < 0.001) and 7% (P < 0.001) in monthly TAVR case volume, respectively, compared with the prepandemic period. The third pandemic wave was not associated with reduced TAVR activity. A greater reduction in TAVR activity was observed in Africa (-52%; P = 0.001), Central-South America (-33%; P < 0.001), and Asia (-29%; P < 0.001). Private hospitals (P = 0.005), urban areas (P = 0.011), low-volume centers (P = 0.002), countries with lower development (P < 0.001) and economic status (P < 0.001), higher COVID-19 incidence (P < 0.001), and more stringent public health restrictions (P < 0.001) experienced a greater reduction in TAVR activity. CONCLUSIONS: TAVR procedural volume declined substantially during the first and second waves of the COVID-19 pandemic, especially in Africa, Central-South America, and Asia. National socioeconomic status, COVID-19 incidence, and public health responses were associated with treatment delays. This information should inform public health policy in case of future global health crises.


Assuntos
Estenose da Valva Aórtica , COVID-19 , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Pandemias , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/epidemiologia , Resultado do Tratamento , COVID-19/epidemiologia , Sistema de Registros , Fatores de Risco
3.
Clin Res Cardiol ; 113(1): 48-57, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37138103

RESUMO

BACKGROUND: Transaxillary (TAx) transcatheter aortic valve implantation (TAVI) is a preferred alternative access in patients ineligible for transfemoral TAVI. AIMS: This study used the Trans-AXillary Intervention (TAXI) registry to compare procedural success according to different types of transcatheter heart valves (THV). METHODS: For the TAXI registry anonymized data of patients treated with TAx-TAVI were collected from 18 centers. Acute procedural, early and 1-month clinical outcomes were adjudicated in accordance with standardized VARC-3 definitions. RESULTS: From 432 patients, 368 patients (85.3%, SE group) received self-expanding (SE) THV and 64 patients (14.8%, BE group) received balloon-expandable (BE) THV. Imaging revealed lower axillary artery diameters in the SE group (max/min diameter in mm: 8.4/6.6 vs 9.4/6.8 mm; p < 0.001/p = 0.04) but a higher proportion of axillary tortuosity in BE group (62/368, 23.6% vs 26/64, 42.6%; p = 0.004) with steeper aorta-left ventricle (LV) inflow (55° vs 51°; p = 0.002) and left ventricular outflow tract (LVOT)-LV inflow angles (40.0° vs 24.5°; 0.002). TAx-TAVI was more often conducted by right sided axillary artery in the BE group (33/368, 9.0% vs 17/64, 26.6%; p < 0.001). Device success was higher in the SE group (317/368, 86.1% vs 44/64, 68.8%, p = 0.0015). In logistic regression analysis, BE THV were a risk factor for vascular complications and axillary stent implantation. CONCLUSIONS: Both, SE and BE THV can be safely used in TAx-TAVI. However, SE THV were more often used and were associated with a higher rate of device success. While SE THV were associated with lower rates of vascular complications, BE THV were more often used in cases with challenging anatomical circumstances.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/cirurgia , Sistema de Registros , Desenho de Prótese
4.
EuroIntervention ; 19(7): 589-599, 2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37436190

RESUMO

BACKGROUND: The optimal timing to perform percutaneous coronary interventions (PCI) in transcatheter aortic valve implantation (TAVI) patients remains unknown. AIMS: We sought to compare different PCI timing strategies in TAVI patients. METHODS: The REVASC-TAVI registry is an international registry including patients undergoing TAVI with significant, stable coronary artery disease (CAD) at preprocedural workup. In this analysis, patients scheduled to undergo PCI before, after or concomitantly with TAVI were included. The main endpoints were all-cause death and a composite of all-cause death, stroke, myocardial infarction (MI) or rehospitalisation for congestive heart failure (CHF) at 2 years. Outcomes were adjusted using the inverse probability treatment weighting (IPTW) method. RESULTS: A total of 1,603 patients were included. PCI was performed before, after or concomitantly with TAVI in 65.6% (n=1,052), 9.8% (n=157) or 24.6% (n=394), respectively. At 2 years, all-cause death was significantly lower in patients undergoing PCI after TAVI as compared with PCI before or concomitantly with TAVI (6.8% vs 20.1% vs 20.6%; p<0.001). Likewise, the composite endpoint was significantly lower in patients undergoing PCI after TAVI as compared with PCI before or concomitantly with TAVI (17.4% vs 30.4% vs 30.0%; p=0.003). Results were confirmed at landmark analyses considering events from 0 to 30 days and from 31 to 720 days. CONCLUSIONS: In patients with severe aortic stenosis and stable coronary artery disease scheduled for TAVI, performance of PCI after TAVI seems to be associated with improved 2-year clinical outcomes compared with other revascularisation timing strategies. These results need to be confirmed in randomised clinical trials.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/complicações , Intervenção Coronária Percutânea/métodos , Estenose da Valva Aórtica/terapia , Infarto do Miocárdio/complicações , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
5.
Cardiol Ther ; 12(2): 361-369, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36899283

RESUMO

INTRODUCTION: During the transcatheter aortic valve replacement (TAVR) procedure, hemodynamic measurements can be used to evaluate transcatheter heart valve (THV) performance. We hypothesized that the occurrence of a significant decrease in invasive aortic pressure immediately after annular contact by a self-expanding THV indicates effective annular sealing. This phenomenon could thus be used as a marker for the occurrence of paravalvular leak (PVL). METHODS: Thirty-eight patients undergoing TAVR procedure with a self-expandable Evolut R or Evolut Pro (Medtronic) valve prosthesis were included in the study. Drop in aortic pressure during valve expansion was defined as a decrease in systolic pressure of 30 mmHg immediately after annular contact. The primary endpoint was the occurrence of more than mild PVL immediately after valve implantation. RESULTS: A pressure drop was seen in 60.5% (23/38) of patients. More than mild PVL requiring balloon post-dilatation (BPD) was significantly more frequent in patients who did not have a systolic pressure decrease > 30 mmHg during valve implantation (46.7% [7/15] vs. 13.0% [3/23], respectively; p = 0.03). Patients without a systolic pressure decrease > 30 mmHg also had a lower mean cover index on computed tomography analysis (16.2% vs. 13.3%; p = 0.016). The 30-day outcomes were similar between the two groups, and echocardiography at 30 days demonstrated more than none/trace PVL in 21.1% (8/38) of patients, with no difference between the two groups. CONCLUSION: A decrease in aortic pressure after annular contact is associated with an increased probability of good hemodynamic outcome after self-expanding TAVR implantation. In addition to other methods, this parameter could be used as an additional marker for optimal valve positioning and hemodynamic outcome during the implantation procedure.

6.
Am Heart J ; 255: 39-51, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36220354

RESUMO

BACKGROUND: Coronary artery disease (CAD) frequently coexists with severe aortic valve stenosis (AS) in patients planned for transcatheter aortic valve implantation (TAVI). How to manage CAD in this patient population is still an unresolved question. In particular, it is still not known whether fractional flow reserve (FFR) guided revascularization with percutaneous coronary intervention (PCI) is superior to medical treatment for CAD in terms of clinical outcomes. STUDY DESIGN: The third Nordic Aortic Valve Intervention (NOTION-3) Trial is an open-label investigator-initiated, multicenter multinational trial planned to randomize 452 patients with severe AS and significant CAD to either FFR-guided PCI or medical treatment, in addition to TAVI. Patients are eligible for the study in the presence of at least 1 significant PCI-eligible coronary stenosis. A significant stenosis is defined as either FFR ≤0.80 and/or diameter stenosis >90%. The primary end point is a composite of first occurring all-cause mortality, myocardial infarction, or urgent revascularization (PCI or coronary artery bypass graft performed during unplanned hospital admission) until the last included patient have been followed for 1 year after the TAVI. SUMMARY: NOTION-3 is a multicenter, multinational randomized trial aiming at comparing FFR-guided revascularization vs medical treatment of CAD in patients with severe AS planned for TAVI.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/cirurgia , Valva Aórtica/cirurgia , Constrição Patológica , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Angiografia Coronária
7.
J Cardiothorac Surg ; 17(1): 322, 2022 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-36529781

RESUMO

BACKGROUND: Patients with severe aortic stenosis and left ventricular systolic dysfunction have a poor prognosis, and this may result in inferior survival also after aortic valve replacement. The outcomes of transcatheter and surgical aortic valve replacement were investigated in this comparative analysis. METHODS: The retrospective nationwide FinnValve registry included data on patients who underwent transcatheter or surgical aortic valve replacement with a bioprosthesis for severe aortic stenosis. Propensity score matching was performed to adjust the outcomes for baseline covariates of patients with reduced (≤ 50%) left ventricular ejection fraction. RESULTS: Within the unselected, consecutive 6463 patients included in the registry, the prevalence of reduced ejection fraction was 20.8% (876 patients) in the surgical cohort and 27.7% (452 patients) in the transcatheter cohort. Reduced left ventricular ejection fraction was associated with decreased survival (adjusted hazards ratio 1.215, 95%CI 1.067-1.385) after a mean follow-up of 3.6 years. Among 255 propensity score matched pairs, 30-day mortality was 3.1% after transcatheter and 7.8% after surgical intervention (p = 0.038). One-year and 4-year survival were 87.5% and 65.9% after transcatheter intervention and 83.9% and 69.6% after surgical intervention (restricted mean survival time ratio, 1.002, 95%CI 0.929-1.080, p = 0.964), respectively. CONCLUSIONS: Reduced left ventricular ejection fraction was associated with increased morbidity and mortality after surgical and transcatheter aortic valve replacement. Thirty-day mortality was higher after surgery, but intermediate-term survival was comparable to transcatheter intervention. Trial registration The FinnValve registry ClinicalTrials.gov Identifier: NCT03385915.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular Esquerda , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Resultado do Tratamento , Disfunção Ventricular Esquerda/complicações , Função Ventricular Esquerda
8.
Circ Cardiovasc Interv ; 15(12): e012417, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36538579

RESUMO

BACKGROUND: The best management of stable coronary artery disease (CAD) in patients undergoing transcatheter aortic valve implantation (TAVI) is still unclear due to the marked inconsistency of the available evidence. METHODS: The REVASC-TAVI registry (Management of Myocardial Revascularization in Patients Undergoing Transcatheter Aortic Valve Implantation With Coronary Artery Disease) collected data from 30 centers worldwide on patients undergoing TAVI who had significant, stable CAD at preprocedural work-up. For the purposes of this analysis, patients with either complete or incomplete myocardial revascularization were compared in a propensity score matched analysis, to take into account of baseline confounders. The primary and co-primary outcomes were all-cause death and the composite of all-cause death, stroke, myocardial infarction, and rehospitalization for heart failure, respectively, at 2 years. RESULTS: Among 2407 patients enrolled, 675 pairs of patients achieving complete or incomplete myocardial revascularization were matched. The primary (21.6% versus 18.2%, hazard ratio' 0.88 [95% CI, 0.66-1.18]; P=0.38) and co-primary composite (29.0% versus 27.1%, hazard ratio' 0.97 [95% CI, 0.76-1.24]; P=0.83) outcome did not differ between patients achieving complete or incomplete myocardial revascularization, respectively. These results were consistent across different prespecified subgroups of patients (< or >75 years of age, Society of Thoracic Surgeons score > or <4%, angina at baseline, diabetes, left ventricular ejection fraction > or <40%, New York Heart Association class I/II or III/IV, renal failure, proximal CAD, multivessel CAD, and left main/proximal anterior descending artery CAD; all P values for interaction >0.10). CONCLUSIONS: The present analysis of the REVASC-TAVI registry showed that, among TAVI patients with significant stable CAD found during the TAVI work-up, completeness of myocardial revascularization achieved either staged or concomitantly with TAVI was similar to a strategy of incomplete revascularization in reducing the risk of all cause death, as well as the risk of death, stroke, myocardial infarction, and rehospitalization for heart failure at 2 years, regardless of the clinical and anatomical situations.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Substituição da Valva Aórtica Transcateter/efeitos adversos , Volume Sistólico , Fatores de Risco , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Função Ventricular Esquerda , Revascularização Miocárdica/efeitos adversos , Infarto do Miocárdio/complicações , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Intervenção Coronária Percutânea/efeitos adversos
9.
Panminerva Med ; 64(4): 427-437, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35638242

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established management strategy for severe aortic valve stenosis. Percutaneous axillary approach for TAVI holds the promise of improving safety without jeopardizing effectiveness in comparison to surgical access. We aimed at appraising the comparative effectiveness of percutaneous vs. surgical axillary approaches for TAVI. METHODS: We performed an international retrospective observational study using de-identified details on baseline, procedural, and 1-month follow-up features. Valve Academic Research Consortium (VARC)-3 criteria were applied throughout. Outcomes of interest were clinical events up to 1 month of follow-up, compared with unadjusted and propensity score-adjusted analyses. RESULTS: A total of 432 patients were included, 189 (43.8%) receiving surgical access, and 243 (56.2%) undergoing percutaneous access. Primary hemostasis failure was more common in the percutaneous group (13.2% vs. 4.2%, P<0.001), leading to more common use of covered stent implantation (13.2% vs. 3.7%, P<0.001). Irrespectively, percutaneous access was associated with shorter hospital stay (-2.6 days [95% confidence interval: -5.0; -0.1], P=0.038), a lower risk of major adverse events (a composite of death, myocardial infarction, stroke, type 3 bleeding, and major access-site related complication; odds ratio=0.44 [0.21; 0.95], P=0.036), major access-site non-vascular complications (odds ratio=0.21 [0.06; 0.77], P=0.018), and brachial plexus impairment (odds ratio=0.16 [0.03; 0.76], P=0.021), and shorter hospital stay (-2.6 days [-5.0; -0.1], P=0.038). CONCLUSIONS: Percutaneous axillary access provides similar or better results than surgical access in patients undergoing TAVI with absolute or relative contraindications to femoral access.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Sistema de Registros , Estudos Retrospectivos , Valva Aórtica/cirurgia , Fatores de Risco
10.
Catheter Cardiovasc Interv ; 97(4): E560-E568, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32767643

RESUMO

BACKGROUND: Conduction defects requiring permanent pacemaker (PPM) implantation are frequent complications occurring after surgical (SAVR) and transcatheter aortic valve replacement (TAVR). METHODS: Patients who underwent TAVR or SAVR with a bioprosthesis from the nationwide FinnValve registry were the subjects of this study. Patients with prior PPM, who received a sutureless prosthesis, or required cardiac resynchronization therapy or implantable cardioverter defibrillator were excluded from this analysis. RESULTS: Four thousand and ten patients underwent SAVR and 1,897 underwent TAVR. TAVR had an increased risk of PPM implantation at 30-day (10.1% vs. 3.5%, unadjusted OR 3.11, 95%CI 2.56-3.87) and 5-year (15.7% vs. 8.6%, unadjusted SHR, 2.12, 95%CI 1.81-2.48) compared to SAVR. PPM implantation within 30 days from the index procedure did not increase the risk of 5-year mortality after either SAVR or TAVR. Among 1,042 propensity score matched pairs, TAVR had an increased risk of PPM implantation at 30-day (9.9% vs. 4.7%, p < .0001) and 5-year (14.7% vs. 11.4%, p = .001), but late (>30 days) PPM implantation at 5-year (4.7% vs. 6.9% SHR 0.72, 95%CI 0.47-1.10) was comparable to SAVR. The types of prosthesis had an impact on 30-day PPM implantation after TAVR, but not on late (>30 days) PPM implantation. CONCLUSIONS: Although the risk of 30-day PPM implantation is higher after TAVR compared to SAVR, late (>30 days) PPM implantation was comparable with these treatment methods. PPM implantation within 30 days did not affect late survival.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
11.
Clin Res Cardiol ; 110(3): 429-439, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33099681

RESUMO

OBJECTIVES: To compare the outcomes after surgical (SAVR) and transcatheter aortic valve replacement (TAVR) for severe stenosis of bicuspid aortic valve (BAV). METHODS: We evaluated the early and mid-term outcome of patients with stenotic BAV who underwent SAVR or TAVR for aortic stenosis from the nationwide FinnValve registry. RESULTS: The FinnValve registry included 6463 AS patients and 1023 (15.8%) of them had BAV. SAVR was performed in 920 patients and TAVR in 103 patients with BAV. In the overall series, device success after TAVR was comparable to SAVR (94.2% vs. 97.1%, p = 0.115). TAVR was associated with increased rate of mild-to-severe paravalvular regurgitation (PVR) (19.4% vs. 7.9%, p < 0.0001) and of moderate-to-severe PVR (2.9% vs. 0.7%, p = 0.053). When newer-generation TAVR devices were evaluated, mild-to-severe PVR (11.9% vs. 7.9%, p = 0.223) and moderate-to-severe PVR (0% vs. 0.7%, p = 1.000) were comparable to SAVR. Type 1 N-L and type 2 L-R/R-N were the BAV morphologies with higher incidence of mild-to-severe PVR (37.5% and 100%, adjusted for new-generation prostheses p = 0.025) compared to other types of BAVs. Among 75 propensity score-matched cohorts, 30-day mortality was 1.3% after TAVR and 5.3% after SAVR (p = 0.375), and 2-year mortality was 9.7% after TAVR and 18.7% after SAVR (p = 0.268) CONCLUSIONS: In patients with stenotic BAV, TAVR seems to achieve early and mid-term results comparable to SAVR. Type 1 N-L and type 2 L-R/R-N BAV morphologies had higher incidence of PVR. Larger studies evaluating different phenotypes of BAV are needed to confirm these findings. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03385915.


Assuntos
Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide/cirurgia , Próteses Valvulares Cardíacas , Pontuação de Propensão , Sistema de Registros , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Valva Aórtica/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
12.
Can J Cardiol ; 37(1): 37-46, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32535038

RESUMO

BACKGROUND: The data on acute kidney injury (AKI) in patients without chronic kidney disease (CKD) after transcatheter aortic valve replacement (TAVR) are limited. The study sought to compare the incidence of AKI and its impact on 5-year mortality after TAVR and surgical aortic valve replacement (SAVR) in patients without CKD. METHODS: This registry included data from 6463 consecutive patients who underwent TAVR or SAVR. CKD was defined as estimated glomerular filtration rate <60 mL/min/1.73 m2. AKI was defined according to the Kidney Disease Improving Global Outcomes criteria. For sensitivity analysis, propensity-score matching between TAVR and SAVR was performed. RESULTS: The study included 4555 consecutive patients (TAVR, n = 1215 and SAVR, n = 3340) without CKD. Propensity-score matching identified 542 pairs. Patients who underwent TAVR had a significantly lower incidence of AKI in comparison to those who underwent SAVR (unmatched 4.7% vs 16.4%, P < 0.001, multivariable analysis: odds ratio, 0.29, 95% confidence interval [CI], 0.20-0.41; matched 5.9% vs 19.0%, P < 0.001). Patients with AKI had significantly increased 5-year mortality compared with those without AKI (unmatched 36.0% vs 19.1%, log-rank P < 0.001; matched 36.3% vs 24.0%, log-rank P < 0.001). The adjusted hazard ratios for 5-year mortality were 1.58 (95% CI, 1.20-2.08) for AKI grade 1, 3.27 (95% CI, 2.09-5.06) for grade 2, and 4.82 (95% CI, 2.93-8.04) for grade 3. CONCLUSIONS: TAVR in patients without CKD was associated with a significantly less frequent incidence of AKI compared with SAVR. AKI significantly increased the risk of 5-year mortality after either TAVR or SAVR, and increasing severity of AKI was incrementally associated with 5-year mortality.


Assuntos
Injúria Renal Aguda/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Injúria Renal Aguda/mortalidade , Idoso , Idoso de 80 Anos ou mais , Feminino , Finlândia/epidemiologia , Taxa de Filtração Glomerular , Humanos , Masculino , Análise por Pareamento , Análise Multivariada , Complicações Pós-Operatórias , Sistema de Registros , Estudos Retrospectivos , Índice de Gravidade de Doença
13.
Catheter Cardiovasc Interv ; 97(6): 1270-1278, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33347739

RESUMO

OBJECTIVES: To study safety and performance of the MANTA Vascular closure device (VCD) under real world conditions in 10 centers. BACKGROUND: The MANTA is a novel plug-based device for large bore arteriotomy closure. METHODS: We included all eligible patients who underwent transfemoral large bore percutaneous procedures. Exclusion criteria were per operator's discretion and included severe calcification or marked tortuosity of the access vessel, presence of marked obesity/cachexia or a systolic blood pressure above 180 mmHg. The primary performance endpoint was time to hemostasis. Primary and secondary safety endpoints were major and minor access site related vascular complications up to 30 days, respectively. Vascular complications were adjudicated by an independent clinical event committee according to VARC-2 criteria. We performed multivariable logistic regression to estimate the effect of baseline and procedural characteristics on any and major vascular complications. RESULTS: Between February 2018 and July 2019 500 patients were enrolled undergoing Transcatheter aortic valve replacement (TAVR, N = 496), Balloon aortic valvuloplasty (BAV, N = 2), Mechanical circulatory support (MCS, N = 1) or Endovascular aneurysm repair (EVAR, N = 1). Mean age was 80.8 ± 6.6 years with a median STS-score of 2.7 [IQR 2.0-4.3] %. MANTA access site complications were major in 20 (4%) and minor in 28 patients (5.6%). Median time to hemostasis was 50 [IQR 20-120] sec. Severe femoral artery calcification, scar presence in groin, longer procedure duration, female gender and history of hypertension were independent predictors for vascular complications. CONCLUSION: In this study, MANTA appeared to be a safe and effective device for large bore access closure under real-world conditions.


Assuntos
Aneurisma da Aorta Abdominal , Estenose da Valva Aórtica , Implante de Prótese Vascular , Cateterismo Periférico , Procedimentos Endovasculares , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Cateterismo Periférico/efeitos adversos , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Hemorragia/etiologia , Técnicas Hemostáticas/efeitos adversos , Humanos , Sistema de Registros , Resultado do Tratamento
14.
PLoS One ; 15(9): e0238953, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32915895

RESUMO

Whether the subtype of atrial fibrillation affects outcomes after transcatheter aortic valve replacement for aortic stenosis is unclear. The nationwide FinnValve registry included 2130 patients who underwent primary after transcatheter aortic valve replacement for aortic stenosis during 2008-2017. Altogether, 281 (13.2%) patients had pre-existing paroxysmal atrial fibrillation, 651 (30.6%) had pre-existing non-paroxysmal atrial fibrillation and 160 (7.5%) were diagnosed with new-onset atrial fibrillation during the index hospitalization. The median follow-up was 2.4 (interquartile range: 1.6-3.8) years. Paroxysmal atrial fibrillation did not affect 30-day or overall mortality (p-values >0.05). Non-paroxysmal atrial fibrillation demonstrated an increased risk of overall mortality (hazard ratio: 1.61, 95% confidence interval: 1.35-1.92; p<0.001), but not 30-day mortality (p = 0.084). New-onset atrial fibrillation demonstrated significantly increased 30-day mortality (hazard ratio: 2.76, 95% confidence interval: 1.25-6.09; p = 0.010) and overall mortality (hazard ratio: 1.68, 95% confidence interval: 1.29-2.19; p<0.001). The incidence of early or late stroke did not differ between atrial fibrillation subtypes (p-values >0.05). In conclusion, non-paroxysmal atrial fibrillation and new-onset atrial fibrillation are associated with increased mortality after transcatheter aortic valve replacement for aortic stenosis, whereas paroxysmal atrial fibrillation has no effect on mortality. These findings suggest that non-paroxysmal atrial fibrillation rather than paroxysmal atrial fibrillation may be associated with structural cardiac damage which is of prognostic significance in patients with aortic stenosis undergoing transcatheter aortic valve replacement.


Assuntos
Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Fibrilação Atrial/classificação , Fibrilação Atrial/complicações , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Fibrilação Atrial/mortalidade , Estudos de Coortes , Feminino , Finlândia/epidemiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Prognóstico , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
15.
J Cardiothorac Surg ; 15(1): 157, 2020 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-32600369

RESUMO

BACKGROUND: There is limited information on the longer-term outcome after transcatheter aortic valve replacement (TAVR) with new-generation prostheses compared to surgical aortic valve replacement (SAVR). The aim of this study was to compare the mid-term outcomes after TAVR with Sapien 3 and SAVR with Perimount Magna Ease bioprostheses for severe aortic stenosis. METHODS: In a retrospective study, we included patients who underwent transfemoral TAVR with Sapien 3 or SAVR with Perimount Magna Ease bioprosthesis between January 2008 and October 2017 from the nationwide FinnValve registry. Propensity score matching was performed to adjust for differences in the baseline characteristics. The Kaplan-Meir method was used to estimate late mortality. RESULTS: A total of 2000 patients were included (689 in the TAVR cohort and 1311 in the SAVR cohort). Propensity score matching resulted in 308 pairs (STS score, TAVR 3.5 ± 2.2% vs. SAVR 3.5 ± 2.8%, p = 0.918). In-hospital mortality was 3.6% after SAVR and 1.3% after TAVR (p = 0.092). Stroke, acute kidney injury, bleeding and atrial fibrillation were significantly more frequent after SAVR, but higher rate of vascular complications was observed after TAVR. The cumulative incidence of permanent pacemaker implantation at 4 years was 13.9% in the TAVR group and 6.9% in the SAVR group (p = 0.0004). At 4-years, all-cause mortality was 20.6% for SAVR and 25.9% for TAVR (p = 0.910). Four-year rates of coronary revascularization, prosthetic valve endocarditis and repeat aortic valve intervention were similar between matched cohorts. CONCLUSIONS: The Sapien 3 bioprosthesis achieves comparable midterm outcomes to a surgical bioprosthesis with proven durability such as the Perimount Magna Ease. However, the Sapien 3 bioprosthesis was associated with better early outcome. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03385915 .


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Mortalidade Hospitalar , Humanos , Masculino , Complicações Pós-Operatórias , Pontuação de Propensão , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
16.
Int J Cardiol ; 315: 86-89, 2020 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-32216975

RESUMO

AIM: The aim of this study was to assess the outcome of transcatheter aortic valve replacement (TAVR) in patients with cancer. METHODS: This is a retrospective study from the nationwide FinnValve registry on 2130 consecutive patients who underwent TAVR for severe AS from January 2008 to October 2017. RESULTS: In this cohort, 417 patients (19.6%) had history of cancer and 113 (5.3%) had an active malignancy at the time of TAVR. Patients with any malignancy had similar late mortality than patients without any malignancy (at 7 years, 65.1% vs. 59.3%, adjusted HR 1.105, 95%CI 0.892-1.369). At 7 years, cancer-related mortality was 22.5% among patients with preoperative cancer, and 11.0% in those without preoperative cancer (p < 0.0001). Among cancer patients, 18 died of the same disease (at 7 years, mortality 12.5%). Active malignancy was not associated with increased risk of all-cause mortality (adjusted HR 1.100, 95%CI 0.757-1.599). However, patients with blood malignancies had a significantly increased risk of mortality (at 4-year, 53.5% vs. 35.4%, adjusted HR 2.029, 95%CI 1.328-3.098). CONCLUSIONS: This analysis showed that, when properly selected by the heart team and oncologists, most cancer patients undergoing TAVR can achieve a good survival and eventually die of other diseases. Blood malignancies seem to carry a poor prognosis in these patients. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03385915; https://clinicaltrials.gov/ct2/show/NCT03385915.


Assuntos
Estenose da Valva Aórtica , Neoplasias , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Neoplasias/cirurgia , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
17.
Circ Rep ; 2(3): 182-191, 2020 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-33693226

RESUMO

Background: The aim of this study was to investigate the impact of anatomical site status and major vascular complication (MVC) severity on the outcome of transfemoral transcatheter aortic valve replacement (TF-TAVR). Methods and Results: The FinnValve registry enrolled consecutive TAVR patients from 2008 to 2017. MVC was divided into 2 groups: non-access site-related MVC (i.e., MVC in aorta, aortic valve annulus or left ventricle); and access site-related MVC (i.e., MVC in iliac or femoral arteries). Severity of access site-related MVC was measured as units of red blood cell (RBC) transfusion. Of 1,842 patients who underwent TF-TAVR, 174 had MVC (9.4%; non-access site related, n=29; access site related, n=145). Patients with MVC had a significantly higher 3-year mortality than those without MVC (40.8% vs. 24.3%; HR, 2.01; 95% CI: 1.16-3.62). Adjusted 3-year mortality risk was significantly increased in the non-access site-related MVC group (mortality, 77.8%; HR, 4.30; 95% CI: 2.63-7.02), but not in the access site-related MVC group (mortality, 32.6%; HR, 1.38; 95% CI: 0.86-2.15). In the access site-related MVC group, only those with RBC transfusion ≥4 units had a significantly increased 3-year mortality risk (mortality, 51.8%; HR, 2.18; 95% CI: 1.19-3.89). Conclusions: In patients undergoing TF-TAVR, MVC was associated with an increased 3-year mortality risk, incrementally correlating with anatomical site and bleeding severity.

18.
Ann Thorac Surg ; 109(1): 110-117, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31288017

RESUMO

BACKGROUND: Patients with severe aortic stenosis and heart failure have poor prognosis, and their outcomes may be suboptimal even after transcatheter (TAVR) and surgical aortic valve replacement (SAVR). METHODS: This is an analysis of the nationwide FinnValve registry, which included patients who underwent primary TAVR or SAVR with a bioprothesis for aortic stenosis. We evaluated the outcome of patients with acute heart failure (AHF) within 60 days prior to TAVR or SAVR. RESULTS: The prevalence of recent AHF was 11.4% (484 of 4241 patients) in the SAVR cohort and 11.3% (210 of 1855 patients) in the TAVR cohort. In the SAVR cohort, AHF was associated with lower 30-day survival (91.3% vs 97.0%; adjusted odds ratio 1.801, 95% confidence interval [CI] 1.125-2.882) and 5-year survival (64.0% vs 81.2%; adjusted hazard ratio 1.482, 95% CI 1.207-1.821). SAVR patients with AHF had higher risk of major bleeding, need of mechanical circulatory support, acute kidney injury, prolonged hospital stay, and composite end-point (30-day mortality, stroke and/or acute kidney injury). Patients with AHF had a trend toward lower 30-day survival (crude rates 95.2% vs 97.9%; adjusted odds ratio 2.028, 95% CI 0.908-4.529) as well as significantly lower 5-year survival (crude rates 45.3% vs 58.5%; adjusted hazard ratio 1.530, 95% CI 1.185-1.976) also after TAVR. AHF increased the risk of acute kidney injury, prolonged hospital stay, and composite end-point after TAVR. CONCLUSIONS: Recent AHF is associated with increased risk of mortality and morbidity after SAVR and TAVR. These findings suggest that aortic stenosis patients should be referred for invasive treatment before the development of clinically evident heart failure.


Assuntos
Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Insuficiência Cardíaca/complicações , Implante de Prótese de Valva Cardíaca/métodos , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Masculino , Estudos Retrospectivos , Fatores de Tempo , Substituição da Valva Aórtica Transcateter
19.
Cardiovasc Toxicol ; 20(3): 328-338, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31811615

RESUMO

Doxorubicin is a potent anticancer drug with cardiotoxicity hampering its use. Neuropeptide Y (NPY) is the most abundant neuropeptide in the heart and a co-transmitter of the sympathetic nervous system that plays a role in cardiac diseases. The aim of this work was to study the impact of NPY on doxorubicin-induced cardiotoxicity. Transgenic mice overexpressing NPY in noradrenergic neurons (NPY-OEDßH) and wild-type mice were treated with a single dose of doxorubicin. Doxorubicin caused cardiotoxicity in both genotypes as demonstrated by decreased weight gain, tendency to reduced ejection fraction, and changes in the expression of several genes relevant to cardiac pathology. Doxorubicin resulted in a tendency to lower ejection fraction in NPY-OEDßH mice more than in wild-type mice. In addition, gain in the whole body lean mass gain was decreased only in NPY-OEDßH mice, suggesting a more severe impact of doxorubicin in this genotype. The effects of doxorubicin on genes expressed in the heart were similar between NPY-OEDßH and wild-type mice. The results demonstrate that doxorubicin at a relatively low dose caused significant cardiotoxicity. There were differences between NPY-OEDßH and wild-type mice in their responses to doxorubicin that suggest NPY to increase susceptibility to cardiotoxicity. This may point to the therapeutic implications as suggested for NPY system in other cardiovascular diseases.


Assuntos
Neurônios Adrenérgicos/metabolismo , Doxorrubicina , Cardiopatias/metabolismo , Miócitos Cardíacos/metabolismo , Neuropeptídeo Y/metabolismo , Animais , Composição Corporal , Sinalização do Cálcio , Cardiotoxicidade , Modelos Animais de Doenças , Cardiopatias/induzido quimicamente , Cardiopatias/genética , Cardiopatias/fisiopatologia , Masculino , Camundongos Endogâmicos C57BL , Camundongos Transgênicos , Miócitos Cardíacos/patologia , Neuropeptídeo Y/genética , Volume Sistólico , Regulação para Cima , Função Ventricular Esquerda , Remodelação Ventricular , Aumento de Peso
20.
Am J Cardiol ; 125(4): 589-596, 2020 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-31831151

RESUMO

Increasing data support transcatheter aortic valve implantation (TAVI) as a valid option over surgical aortic valve replacement (SAVR) in the treatment for severe aortic stenosis (AS) also in patients with low operative risk. However, limited data exist on the outcome of TAVI and SAVR in low-risk patients without coronary artery disease (CAD). The FinnValve registry included data on 6463 patients who underwent TAVI or SAVR with bioprosthesis between 2008 and 2017. Herein, we evaluated the outcome of low operative risk as defined by STS-PROM score <3% and absence of CAD, previous stroke and other relevant co-morbidities. Only patients who underwent TAVI with third-generation prostheses and SAVR with Perimount Magna Ease or Trifecta prostheses were included in this analysis. The primary endpoints were 30-day and 3-year all-cause mortality. Overall, 1,006 patients (175 TAVI patients and 831 SAVR patients) met the inclusion criteria of this analysis. Propensity score matching resulted in 140 pairs with similar baseline characteristics. Among these matched pairs, 30-day mortality was 2.1% in both TAVI and SAVR cohorts (p = 1.00) and 3-year mortality was 17.0% after TAVI and 14.6% after SAVR (p = 0.805). Lower rates of bleeding and atrial fibrillation, and shorter hospital stay were observed after TAVI. The need of new permanent pacemaker implantation and the incidence of early stroke did not differ between groups. In conclusion, TAVI using third-generation prostheses achieved similar early and mid-term survival compared with SAVR in low-risk patients without CAD.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Estenose da Valva Aórtica/mortalidade , Doença da Artéria Coronariana , Feminino , Finlândia , Humanos , Masculino , Pontuação de Propensão , Sistema de Registros , Estudos Retrospectivos , Taxa de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...