Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLOS Glob Public Health ; 3(3): e0001354, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36963078

RESUMO

BACKGROUND: Preterm birth and resulting respiratory failure is a leading cause of newborn death- the majority of which occur in resource-constrained settings and could be prevented with bubble continuous positive airway pressure (bCPAP). Commercialized devices are expensive, however, and sites commonly use improvised devices utilizing 100% oxygen which can cause blindness. To address this, PATH and a multidisciplinary team developed a very low-cost bCPAP device including fixed-ratio oxygen blenders. OBJECTIVE: We assessed feasibility of use of the device on neonatal patients as well as the usability and acceptability of the device by healthcare workers. This study did not evaluate device effectiveness. METHODS: The study took place in a Ugandan level two unit. Neonates with respiratory failure were treated with the bCPAP device. Prospective data were collected through observation as well as likert-style scales and interviews with healthcare workers. Data were analyzed using frequencies, means and standard deviation and interviews via a descriptive coding method. Retrospectively registered via ClinicalTrials.gov number NCT05462509. RESULTS: Fourteen neonates were treated with the bCPAP device in October-December 2021. Patients were born onsite (57%), with median weight of 1.3 kg (IQR 1-1.8). Median treatment length was 2.5 days (IQR 2-6). bCPAP was stopped due to: improvement (83%) and death (17%). All patients experienced episodes of saturations >95%. Median time for device set up: 15 minutes (IQR 12-18) and changing the blender: 15 seconds (IQR 12-27). After initial device use, 9 out of 9 nurses report the set-up as well as blender use was "easy" and their overall satisfaction with the device was 8.5/10 (IQR 6.5-9.5). Interview themes included the appreciation for the ability to administer less than 100% oxygen, desire to continue use of the device, and a desire for additional blenders. CONCLUSIONS: In facilities otherwise using 100% oxygen, use of the bCPAP device including oxygen blenders is feasible and acceptable to healthcare workers. TRIAL REGISTRATION: ClinicalTrials.gov, Identifier NCT05462509.

2.
Vaccine ; 36(12): 1700-1709, 2018 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-29449099

RESUMO

Despite limitations of glass packaging for vaccines, the industry has been slow to implement alternative formats. Polymer containers may address many of these limitations, such as breakage and delamination. However, the ability of polymer containers to achieve cost of goods sold (COGS) and total cost of delivery (TCOD) competitive with that of glass containers is unclear, especially for cost-sensitive low- and lower-middle-income countries. COGS and TCOD models for oral and parenteral vaccine packaging formats were developed based on information from subject matter experts, published literature, and Kenya's comprehensive multiyear plan for immunization. Rotavirus and inactivated poliovirus vaccines (IPV) were used as representative examples of oral and parenteral vaccines, respectively. Packaging technologies evaluated included glass vials, blow-fill-seal (BFS) containers, preformed polymer containers, and compact prefilled auto-disable (CPAD) devices in both BFS and preformed formats. For oral vaccine packaging, BFS multi-monodose (MMD) ampoules were the least expensive format, with a COGS of $0.12 per dose. In comparison, oral single-dose glass vials had a COGS of $0.40. BFS MMD ampoules had the lowest TCOD of oral vaccine containers at $1.19 per dose delivered, and ten-dose glass vials had a TCOD of $1.61 per dose delivered. For parenteral vaccines, the lowest COGS was achieved with ten-dose glass vials at $0.22 per dose. In contrast, preformed CPAD devices had the highest COGS at $0.60 per dose. Ten-dose glass vials achieved the lowest TCOD of the parenteral vaccine formats at $1.56 per dose delivered. Of the polymer containers for parenteral vaccines, BFS MMD ampoules achieved the lowest TCOD at $1.89 per dose delivered, whereas preformed CPAD devices remained the most expensive format, at $2.25 per dose delivered. Given their potential to address the limitations of glass and reduce COGS and TCOD, polymer containers deserve further consideration as alternative approaches for vaccine packaging.


Assuntos
Embalagem de Medicamentos , Vacinação , Vacinas , Administração Oral , Custos e Análise de Custo , Humanos , Programas de Imunização , Vacinação/métodos , Vacinas/administração & dosagem
3.
Hum Vaccin Immunother ; 13(7): 1666-1668, 2017 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-28463054

RESUMO

Shortages of vaccines such as inactivated poliovirus and yellow fever vaccines have been addressed by administering reduced-or fractional-doses, as recommended by the World Health Organization Strategic Advisory Group of Experts on Immunization, to expand population coverage in countries at risk. We evaluated 3 kinds of vaccine vial stoppers to assess their performance after increased piercing from repeated withdrawal of doses needed when using fractional doses (0.1 mL) from presentations intended for full-dose (0.5 mL) delivery. Self-sealing capacity and fragmentation of the stopper were assessed via modified versions of international standard protocols. All stoppers maintained self-sealing capacity after 100 punctures. The damage to stoppers measured as the fragmentation rate was within the target of ≤ 10% of punctures resulting in a fragment after as many as 50 punctures. We concluded that stopper failure is not likely to be a concern if existing vaccine vials containing up to 10 regular doses are used up to 50 times for fractional dose delivery.


Assuntos
Contaminação de Medicamentos/prevenção & controle , Embalagem de Medicamentos , Vacinas contra Poliovirus/administração & dosagem , Humanos
4.
Int J Pediatr ; 2016: 9214389, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27999601

RESUMO

Hypoxemia is a complication of pneumonia-the leading infectious cause of death in children worldwide. Treatment generally requires oxygen-enriched air, but access in low-resource settings is expensive and unreliable. We explored use of reservoir cannulas (RCs), which yield oxygen savings in adults but have not been examined in children. Toddler, small child, and adolescent breathing profiles were simulated with artificial lung and airway models. An oxygen concentrator provided flow rates of 0 to 5 L/min via a standard nasal cannula (NC) or RC, and delivered oxygen fraction (FdO2) was measured. The oxygen savings ratio (SR) and absolute flow savings (AFS) were calculated, comparing NC and RC. We demonstrated proof-of-concept that pendant RCs could conserve oxygen during pediatric therapy. SR mean and standard deviation were 1.1 ± 0.2 to 1.4 ± 0.4, 1.1 ± 0.1 to 1.7 ± 0.3, and 1.3 ± 0.1 to 2.4 ± 0.3 for toddler, small child, and adolescent models, respectively. Maximum AFS observed were 0.3 ± 0.3, 0.2 ± 0.1, and 1.4 ± 0.3 L/min for the same models. RCs have the potential to reduce oxygen consumption during treatment of hypoxemia in children; however, further evaluation of products is needed, followed by clinical analysis in patients.

5.
Vaccine ; 34(22): 2483-9, 2016 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-27085171

RESUMO

Rotavirus infection, which can be prevented by vaccination, is responsible for a high burden of acute gastroenteritis disease in children, especially in low-income countries. An appropriate formulation, packaging, and delivery device for oral rotavirus vaccine has the potential to reduce the manufacturing cost of the vaccine and the logistical impact associated with introduction of a new vaccine, simplify the vaccination procedure, and ensure that the vaccine is safely and accurately delivered to children. Single-dose prefilled presentations can be easy to use; however, they are typically more expensive, can be a bottleneck during production, and occupy a greater volume per dose vis-à-vis supply chain storage and medical waste disposal, which is a challenge in low-resource settings. Multi-dose presentations used thus far have other issues, including increased wastage of vaccine and the need for separate delivery devices. In this study, the goals were to evaluate both the technical feasibility of using preservatives to develop a liquid multi-dose formulation and the primary packaging alternatives for orally delivered, liquid rotavirus vaccines. The feasibility evaluation included evaluation of commonly used preservatives for compatibility with rotavirus vaccines and stability testing of rotavirus vaccine in various primary containers, including Lameplast's plastic tubes, BD's oral dispenser version of Uniject™ (Uniject DP), rommelag's blow-fill-seal containers, and MEDInstill's multi-dose vial and pouch. These presentations were compared to a standard glass vial. The results showed that none of the preservatives tested were compatible with a live attenuated rotavirus vaccine because they had a detrimental effect on the viability of the virus. In the presence of preservatives, vaccine virus titers declined to undetectable levels within 1 month. The vaccine formulation without preservatives maintained a stability profile over 12 months in all primary containers that was similar to its profile in standard glass vials. This study demonstrates that there are multiple options for the primary container for rotavirus vaccines intended for oral delivery. Selection of an optimal primary container should take into consideration additional factors, including stability as well as cold chain volume, usability, cost, and manufacturing feasibility.


Assuntos
Embalagem de Medicamentos , Conservantes Farmacêuticos , Vacinas contra Rotavirus/imunologia , Potência de Vacina , Administração Oral , Estudos de Viabilidade , Gastroenterite/prevenção & controle , Vidro , Humanos , Viabilidade Microbiana , Rotavirus/fisiologia , Infecções por Rotavirus/prevenção & controle , Vacinas contra Rotavirus/administração & dosagem , Vacinas contra Rotavirus/provisão & distribuição , Vacinação/métodos , Vacinas Atenuadas/química , Vacinas Atenuadas/imunologia
6.
Respir Care ; 60(9): 1227-37, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26152468

RESUMO

BACKGROUND: A self-inflating bag-mask device is specified by international policy guidelines as standard prototype of care for newborn resuscitation. Our hypothesis is that a new bag-mask design would be as effective and easy to use as a standard, self-inflating resuscitation bag-mask. METHODS: We conducted a comparative evaluation of the performance and acceptability of the Laerdal 220-mL resuscitator with a size-1 mask (NeoNatalie) and a Laerdal prototype Upright resuscitator with a modified mask. Participants evaluated the devices in random order using a commercially available test lung and training mannikin with an integrated chest-rise module. The test lung was configured with healthy and sick newborn lung mechanics. Two user groups participated: (1) frequent users who had used manual resuscitators to resuscitate infants and (2) infrequent users who received competency-based training and had not previously used manual resuscitators to resuscitate infants. RESULTS: Thirty-eight individuals participated in the study during March 2013. Both resuscitators are capable of delivering the minimum required tidal volumes to newborns. The Upright device provided a significant reduction in the percentage of inadequate ventilations (< 12.5 mL) compared with the NeoNatalie. Although the test sequences with low-compliance lung settings showed no difference in the percentage of excessive ventilations (> 37.5 mL) between the Upright and NeoNatalie, the test sequences with normal-compliance lung settings showed a higher percentage of excessive ventilations with both, and the increase was greater with the Upright than with the NeoNatalie (85.92% vs 71.39%, P < .001). The subjective acceptability and disassembly/reassembly tests were supportive of the new device design. CONCLUSIONS: The performance and acceptability of the Upright device in this user population suggest that the device may be suitable for effective ventilation by infrequent users in low-resource settings. The Upright device should be tested in such a setting.


Assuntos
Reanimação Cardiopulmonar/instrumentação , Insuflação/instrumentação , Máscaras , Respiração Artificial/instrumentação , Adulto , Desenho de Equipamento , Feminino , Humanos , Recém-Nascido , Pulmão/fisiopatologia , Complacência Pulmonar , Masculino , Aceitação pelo Paciente de Cuidados de Saúde , Volume de Ventilação Pulmonar
7.
Vaccine ; 33(37): 4705-11, 2015 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-25964169

RESUMO

Although the number of vaccines and diagnostic tests currently delivered intradermally is limited, this route of administration offers potential advantages due to the high concentration of antigen-presenting cells in the skin. One factor which may in part be limiting development and use of intradermal (ID) administration is concern about the ease and reliability of the needle and syringe-based Mantoux technique. A phase I clinical study was conducted to evaluate two ID adapters that have been developed as injection-delivery aids to increase the safety, simplicity, and reliability of ID injection: a prototype autodisable, intradermal (ADID) adapter for autodisable (AD) syringes, and a marketed side-merge adapter (SMA). Thirty healthy adult volunteers each received six injections of 0.1 mL of sterile saline solution. Each adapter was used to give injections into the upper deltoid, forearm, and suprascapular regions of each volunteer. The needle-bevel orientation during injection was random. Injection performance was determined by measuring wheal size and fluid leakage. Wheals were similar in size for the ADID adapter (mean 9.9 ± 0.17 mm) and SMA (mean 9.8 ± 0.15 mm). In all of the injections completed with the SMA, and 98% of those completed with the ADID, fluid leakage was less than 10% of the intended injection volume. Minor skin abrasions were the only adverse events. Based on self-reporting of pain, injections were well tolerated (mean pain score of 2 on a 0-10 scale). ID delivery using the SMA and ADID adapters appears safe and effective.


Assuntos
Sistemas de Liberação de Medicamentos , Injeções Intradérmicas/métodos , Seringas , Vacinas/administração & dosagem , Adulto , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/patologia , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
8.
Vaccine ; 33(37): 4719-26, 2015 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-25862299

RESUMO

INTRODUCTION: Intradermal bacille Calmette-Guérin (BCG) vaccination by needle-free, disposable-syringe jet injectors (DSJI) is an alternative to the Mantoux method using needle and syringe (NS). We compared the safety and immunogenicity of BCG administration via the DSJI and NS techniques in adults and newborn infants at the South African Tuberculosis Vaccine Initiative (SATVI) research site in South Africa. METHOD: Thirty adults and 66 newborn infants were randomized 1:1 to receive intradermal BCG vaccine (0.1 mL in adults; 0.05 mL in infants) via DSJI or NS. Wheal diameter (mm) and skin fluid deposition at the site of injection (SOI) were measured immediately post-vaccination. Adverse events and SOI reactogenicity data were collected 30 min and 1, 2, 4, and 12 weeks after vaccination for adults and at 30 min and 4, 10, and 14 weeks for infants. Blood was collected in infants at 10 and 14 weeks to assess BCG-specific T-cell immune responses. RESULTS: More infant BCG vaccinations by DSJI deposited >5 µL fluid on the skin surface, compared to NS (49% versus 9%, p=0.001). However, all 12 infant vaccinations that did not produce any SOI wheal occurred in the NS group (36%, p<0.001). Median wheal diameter, in participants for which an SOI wheal formed, did not differ significantly between groups in infants (combined 3.0mm IQR 2.0 to 4.0, p=0.59) or in adults (combined 9.0mm IQR 7.0 to 10.0, p=0.13). Adverse events were similar between study arms. Proportion of participants with BCG scars after three months did not differ in adults (combined 97%, p=0.67) or infants (combined 62%, p=0.13). Frequencies of BCG-specific clusters of differentiation 4 (CD4) and clusters of differentiation 8 (CD8) T-cells co-expressing IFN-γ, TNF-α, IL-2, and/or IL-17 were not different in the DSJI and NS groups. CONCLUSION: BCG vaccination of newborn infants via DSJI was more likely to deliver an appropriate intradermal wheal at the SOI as compared to NS, despite leaving more fluid on the surface of the skin. Safety, reactogenicity, and antigen-specific T-cell immune responses did not differ between DSJI and NS techniques.


Assuntos
Vacina BCG/administração & dosagem , Vacina BCG/efeitos adversos , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/epidemiologia , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/patologia , Adolescente , Adulto , Citocinas/metabolismo , Feminino , Humanos , Recém-Nascido , Injeções Intradérmicas/efeitos adversos , Injeções Intradérmicas/métodos , Injeções a Jato/efeitos adversos , Injeções a Jato/métodos , Masculino , Pessoa de Meia-Idade , África do Sul , Linfócitos T/imunologia , Adulto Jovem
9.
Ann Otol Rhinol Laryngol Suppl ; 197: 2-24, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17542465

RESUMO

OBJECTIVES: A new technique for determining the position of each electrode in the cochlea is described and applied to spiral computed tomography data from 15 patients implanted with Advanced Bionics HiFocus I, Ij, or Helix arrays. METHODS: ANALYZE imaging software was used to register 3-dimensional image volumes from patients' preoperative and postoperative scans and from a single body donor whose unimplanted ears were scanned clinically, with micro computed tomography and with orthogonal-plane fluorescence optical sectioning (OPFOS) microscopy. By use of this registration, we compared the atlas of OPFOS images of soft tissue within the body donor's cochlea with the bone and fluid/ tissue boundary available in patient scan data to choose the midmodiolar axis position and judge the electrode position in the scala tympani or scala vestibuli, including the distance to the medial and lateral scalar walls. The angular rotation 0 degrees start point is a line joining the midmodiolar axis and the middle of the cochlear canal entry from the vestibule. RESULTS: The group mean array insertion depth was 477 degrees (range, 286 degrees to 655 degrees). The word scores were negatively correlated (r = -0.59; p = .028) with the number of electrodes in the scala vestibuli. CONCLUSIONS: Although the individual variability in all measures was large, repeated patterns of suboptimal electrode placement were observed across subjects, underscoring the applicability of this technique.


Assuntos
Cóclea/diagnóstico por imagem , Cóclea/patologia , Implante Coclear/métodos , Implantes Cocleares , Perda Auditiva/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Perda Auditiva/diagnóstico por imagem , Perda Auditiva/patologia , Humanos , Imageamento Tridimensional , Masculino , Microscopia de Fluorescência , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...