Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 100
Filtrar
1.
Cardiovasc Intervent Radiol ; 42(3): 460-465, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30603971

RESUMO

PURPOSE: To report technical success and clinical outcomes of transfemoral venous access for upper extremity dialysis interventions. MATERIALS AND METHODS: A total of 15 patients underwent a transfemoral venous approach for fistulography (n = 4; 27%) or thrombectomy (n = 11; 73%) over a 14-month period. Access characteristics, sheath size, thrombectomy method, angioplasty site, fluoroscopy time, radiation dose, technical and clinical success, complications, and post-intervention primary and secondary patency rates were recorded. RESULTS: Access type included arteriovenous fistulas (n = 10; 67%) and grafts (n = 5; 33%). The most common configuration was brachio-brachial (n = 6; 38%). Mean age of access was 37 months. Mean prior interventions were 4. Right CFV access was used in all patients using 6-8-French (most common: 7-French [n = 10; 67%]) sheaths. Most thrombectomies (n = 11; 73%) required both pharmacologic and mechanical maceration (n = 9; 82%). All accesses required angioplasty to treat underlying stenosis at the outflow vein (n = 12; 80%) or arteriovenous anastomosis (n = 9; 90%). Mean fluoroscopy time was 26.43 min. Air kerma and dose area product were 178.06 ± 225.77 mGy and 57,768.83 ± 87,553.29 µGym2, respectively. Procedural and clinical success rates were 93% and 80%, respectively. Technical failure was due to persistent stenosis in one patient. Clinical failure was due to unsuccessful dialysis immediately following intervention in three patients. Mean post-intervention primary patency and secondary patency durations were 2.8 and 4.8 months, respectively. Primary patency rates at 1 and 3 months were 50% and 35%, respectively. Secondary patency rates at 1 and 3 months were 58% and 30%, respectively. CONCLUSION: A transfemoral venous approach for intervention of upper extremity dialysis accesses may be a valuable adjunct to traditional approaches.


Assuntos
Derivação Arteriovenosa Cirúrgica/métodos , Procedimentos Endovasculares/métodos , Veia Femoral , Diálise Renal/métodos , Extremidade Superior/irrigação sanguínea , Grau de Desobstrução Vascular/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
2.
Clin Radiol ; 69(3): 246-53, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24295735

RESUMO

AIM: To assess the feasibility of a fast single-bolus combined carotid and coronary computed tomography angiography (CTA) protocol in asymptomatic patients. MATERIALS AND METHODS: Thirty-three consecutive patients (18 women and 15 men) with a median age of 61 ± 14 years old (range 37-87 years) with known or suspected atherosclerotic disease were enrolled in this prospective study. A single breath-hold, single biphasic injection protocol (50 ml at 3 ml/s, 50 ml at 5 ml/s, 50 ml saline flush at 5 ml/s) was used for combined CTA imaging of the supra-aortic (SAA) and coronary arteries (CA) on a 64-slice dual-source CT (DSCT) machine. Helical CTA acquisition of the SAA was followed by prospective electrocardiography (ECG)-triggered coronary CTA. Subjective (four-point scale) image quality and objective signal-to-noise (SNR) and contrast-to-noise (CNR) measurements were performed. Vascular disease was graded on a four-point scale (grade 1: absent; grade 2: mild, grade 3: moderate; grade 4: severe). The radiation dose was recorded for each patient. RESULTS: The average enhancement and subjective quality score of SAA and CA segments were 396 HU/358 HU and 1.2 ± 0.3/1.72 ± 0.4, respectively. The SNR was 27.1 ± 1.7 in the SAA and 21.6 ± 1.6 in the CA (p < 0.0001). The CNR was 18.1 ± 1.2 and 15.9 ± 1.8, respectively (p = 0.4). Four percent of SAA and 14% of CA segments (mostly due to peri-venous streak artefacts and small calibre, respectively) produced non-diagnostic images. SAA findings were as follows: 26/33 (79%) patients showed no disease and 6/33 (18%) had grade 2 and 1/33 (3%) had grade 3 disease. CA findings were as follows: 25/33 (76%) showed no disease and 6/33 (18%) patients had grade 2 and 2/33 (6%) had grade 3 disease. Five patients had disease in both districts. The average radiation dose for the combined CTA angiogram was 4.3 ± 0.6 mSv. CONCLUSION: A fast, low-dose combined DSCT angiography protocol appears technically feasible for imaging carotid and coronary atherosclerotic disease.


Assuntos
Angiografia/métodos , Doenças das Artérias Carótidas/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada Espiral , Adulto , Idoso , Idoso de 80 Anos ou mais , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Iopamidol , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador
3.
Clin Radiol ; 68(3): e154-63, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23276388

RESUMO

AIM: To assess the diagnostic value of coronary dual-source computed tomography (DSCT) as a comprehensive, non-invasive tool in the preoperative cardiac evaluation of patients undergoing bariatric surgery. MATERIALS AND METHODS: Thirty consecutive obese [average body mass index (BMI): 45 ± 7.6, range: 35-59] patients (24 women; six men; median age: 52 ± 15 years) were enrolled in this institutional review board (IRB)-approved, Health Insurance Portability and Accountability Act of 1996 (HIPAA)-compliant prospective study. Calcium scoring (CaS) and electrocardiography (ECG)-gated images of the coronary arteries were obtained with a large body habitus protocol (120 kV; 430 mAs; 100 ml iodinated contrast medium at 7 ml/s injection rate) on a DSCT machine. Qualitative (four-point: 1 = excellent to 4 = not delineable) coronary segmental analysis, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) measurements were performed. The presence and degree of vascular disease (four-grade scale: mild to severe) was correlated with CaS and cardiovascular (CV) risk stratification blood tests. In patients with severe stenosis (>70%), findings were compared with cardiac nuclear medicine imaging (single photon-emission computed tomography; SPECT) imaging. RESULTS: The average HR, enhancement, and quality score were 64 ± 7 beats/min, 288 ± 66 HU and 1.8 ± .5, respectively. Ninety-three percent (417/450) of the coronary segments were rated diagnostic. The SNRs and CNRs were 17 ± 9 and 12 ± 7 for the right coronary artery; 17 ± 8 and 12 ± 7 for the left main coronary artery; 16 ± 9 and 11 ± 7 for the left anterior descending coronary artery; and 15 ± 7 and 10 ± 6 for the left circumflex coronary artery. Ten of the 30 patients (33%) demonstrated coronary artery disease (CAD) of which two (6%) showed three-vessel disease. Four (13%) patients showed severe disease: in three of which the presence of significant stenosis was confirmed by SPECT and by catheter angiography in the fourth patient. Neither the CaS, nor the CV risk stratification tests showed significant correlation with presence or degree of CAD (p > 0.05). CONCLUSIONS: Coronary DSCT is a robust alternative imaging tool in the preoperative assessment of patients undergoing bariatric surgery.


Assuntos
Cirurgia Bariátrica , Doenças Cardiovasculares/diagnóstico por imagem , Cuidados Pré-Operatórios , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Meios de Contraste , Eletrocardiografia , Feminino , Humanos , Iopamidol , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Fatores de Risco , Tomografia Computadorizada de Emissão de Fóton Único
4.
AJNR Am J Neuroradiol ; 33(4): 643-8, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22207297

RESUMO

BACKGROUND AND PURPOSE: Recently we published a novel method of thrombus preparation for use in a swine model for evaluation of thrombectomy designs. The clot (fibrin rich clot) is characterized by its similarity in histologic characteristics to the thromboemboli recovered from stroke patients. The purpose of this latest study was to evaluate if the performance of a mechanical thrombectomy device was affected by the histologic characteristics of thromboembolus. Erythrocyte rich clot, which was created using exogenous thrombin, and the novel experimental clot with abundance of fibrin/cellular component were used for comparison. The Merci clot retriever was used for the evaluation and the angiographic outcomes were analyzed. MATERIALS AND METHODS: Two histologically different types of experimental clot, a conventionally used thrombin-induced clot (erythrocyte-rich clot) and a novel experimental clot that is similar in histologic characteristics to the thromboemboli recovered from patients with stroke (fibrin-rich clot), were prepared. Eight extracranial arteries in swine were occluded with erythrocyte-rich clot (group A), and 8 were occluded with fibrin-rich clot (group B), and MT by using the Merci clot retriever device was performed. Angiographic results in each group were evaluated. RESULTS: A total of 48 attempts at MT were made. The average number of attempts to achieve TIMI grade II or III recanalization was 2.75 times in group A and 4.5 times in group B (P < .001), respectively. The mean time to achieve recanalization was 15.5 minutes in group A and 81.5 minutes in group B (P < .01). Every vessel in group A showed recanalization (100%), whereas only 3 of 8 samples (37.5%) achieved recanalization in group B. CONCLUSIONS: In this model, arteries occluded by fibrin-rich clot demonstrated a significantly lower recanalization rate, lower final TIMI score, and a longer mean recanalization time than did arteries occluded by erythrocyte-rich clot. The angiographic outcome of MT by using the Merci clot retriever system was influenced by the histologic characteristics of the occluding thromboembolus.


Assuntos
Trombólise Mecânica/instrumentação , Trombectomia/instrumentação , Trombose/patologia , Trombose/terapia , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Suínos , Resultado do Tratamento
5.
AJNR Am J Neuroradiol ; 30(1): 46-52, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18842763

RESUMO

BACKGROUND AND PURPOSE: High-resolution contrast-enhanced MR angiography (CE-MRA) acquired at 3T exquisitely depict carotid artery (CA) stenosis. In this study, we examined the agreement of different vessel-analysis tools with manual quantitative measurement by 2 readers using CE-MRA data. MATERIALS AND METHODS: Three vessel tools determining the trajectory of the vessel of interest and, subsequently, the vessel dimensions were tested against manual measurements. Diameter and area stenoses were calculated. CE-MRA data of 32 patients with CA stenosis were evaluated. The agreement between different measurements was assessed with kappa statistics after categorizing stenosis (<25%, 25%-49%, 50%-69%, 70%-99%, and 100%). RESULTS: The mean grades of stenosis based on diameter measurements were 59% (readers) and 60%/56%/59% based on the analysis with tools A/B/C (P = 0.2-0.7). kappa values for agreement between readers and the vessel tools were 0.73/0.77/0.77 (tools A/B/C for all CAs) and 0.66/0.74/0.75 (for the symptomatic side). The mean grades of stenoses based on area measurements for tools A/B/C were 68%/63%/69% versus 58% for readers. Values from readers differed significantly from those for tools A and C (P < 0.01). kappa values for agreement between readers and the vessel tools were 0.66/0.55/0.64 (for all CAs) and 0.53/0.44/0.57 (for the symptomatic side). CONCLUSIONS: The automated approach allows accurate assessment of vessel dimensions in MRA images at least for diameter measurements according to the North American Symptomatic Carotid Endarterectomy Trial criteria.


Assuntos
Algoritmos , Artérias Carótidas/patologia , Estenose das Carótidas/patologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Adulto , Idoso , Inteligência Artificial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
AJNR Am J Neuroradiol ; 28(7): 1362-8, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17698541

RESUMO

BACKGROUND AND PURPOSE: Bone-subtraction techniques have been shown to enhance CT angiography (CTA) interpretation, but motion can lead to incomplete bone removal. The aim of this study was to evaluate 2 novel registration techniques to compensate for patient motion. MATERIALS AND METHODS: Fifty-four patients underwent bone-subtraction CTA (BSCTA) for the evaluation of the neck vessels with 64-section CT. We tested 3 different registration procedures: pure rigid registration (BSCTA), slab-based registration (SB-BSCTA), and a partially rigid registration (PR-BSCTA) approach. Subtraction quality for the assessment of different vascular segments was evaluated by 2 examiners in a blinded fashion. The Cohen kappa test was applied for interobserver variability, and the Wilcoxon signed rank test, for differences between the procedures. Motion between the corresponding datasets was measured and plotted against image-quality scores. RESULTS: Algorithms with motion compensation revealed higher image-quality scores (SB-BSCTA, mean 4.31; PR-BSCTA, mean 4.43) than pure rigid registration (BSCTA, mean 3.88). PR-BSCTA was rated superior to SB-BSCTA for the evaluation of the cervical internal and external carotid arteries (P<.001), whereas there was no significant difference for the other vessels (P=.157-.655). Both algorithms were clearly superior to pure rigid registration for all vessels except the basilar and ophthalmic artery. Interobserver agreement was high (kappa=0.46-0.98). CONCLUSION: Bone-subtraction algorithms with motion compensation provided higher image-quality scores than pure rigid registration methods, especially in cases with complex motion. PR-BSCTA was rated superior to SB-BSCTA in the visualization of the internal and external carotid arteries.


Assuntos
Artefatos , Osso e Ossos/diagnóstico por imagem , Angiografia Cerebral/métodos , Aumento da Imagem/métodos , Técnica de Subtração , Tomografia Computadorizada por Raios X/métodos , Cabeça/irrigação sanguínea , Cabeça/diagnóstico por imagem , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Movimento (Física) , Pescoço/irrigação sanguínea , Pescoço/diagnóstico por imagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Eur Respir J ; 27(2): 307-15, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16452585

RESUMO

Quantitative image analysis of high-resolution computed tomography (HRCT) performed at residual volume, before and after methacholine, is a sensitive method of detecting small airways involvement in asthma and response to therapy targeted to the small airways. Since an oral anti-leukotriene reaches the small airways via the circulation, the present authors hypothesised that treatment with montelukast would lead to improved small airway patency. A double-blind crossover study compared the effect of montelukast versus placebo for 4 weeks in 16 mild-to-moderate steroid-naïve asthmatics. Small airways function was evaluated by HRCT at residual volume before and after methacholine to assess regional air-trapping and airways hyperresponsiveness, as well as by physiological studies of small airways. Montelukast treatment resulted in significantly less regional air-trapping on HRCT on the pre-methacholine images when compared with placebo, as well as improvement in total quality of life scores and symptom sub-scores. However, montelukast treatment had no effect on increases in regional air-trapping on HRCT in response to methacholine. No differences were noted in global measures of small airways physiology between placebo and montelukast. In conclusion, distal airways disease improves in asthmatic subjects treated with montelukast. This improvement can be detected with high-resolution computed tomography, but not with conventional physiological studies.


Assuntos
Acetatos/uso terapêutico , Antiasmáticos/uso terapêutico , Asma/tratamento farmacológico , Asma/fisiopatologia , Quinolinas/uso terapêutico , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Idoso , Asma/diagnóstico por imagem , Estudos Cross-Over , Ciclopropanos , Método Duplo-Cego , Feminino , Humanos , Modelos Lineares , Masculino , Cloreto de Metacolina , Pessoa de Meia-Idade , Testes de Função Respiratória , Estatísticas não Paramétricas , Sulfetos , Resultado do Tratamento
8.
Br J Sports Med ; 38(5): 553-60; discussion 553-60, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15388538

RESUMO

BACKGROUND: TauVO(2 )at the onset of constant work rate (CWR) exercise is a variable of aerobic fitness that shortens with physical training and lengthens with cardiopulmonary disease. Determination of tauVO(2) with sufficiently high confidence has typically required multiple exercise transitions limiting its clinical application. OBJECTIVES: To design a protocol to determine tauVO(2) reliably but simply. METHODS: On each of three days, five healthy men performed two CWR tests on a cycle ergometer below the metabolic threshold (VO(2)theta) for blood lactate accumulation as determined by gas exchange measurements followed by an incremental work rate (IWR) test. TauVO(2) was determined (a) from the on-transit (on-tauVO(2)) and off-transit (off-tauVO(2)) of six CWR tests both individually and superimposed, using non-linear regression with a monoexponential model, and (b) by geometric analysis of the IWR tests (ramp-tauVO(2)). RESULTS: Group means (SD) were: VO(2)max 3.84 (0.44) litres/min, VO(2)theta 1.88 (0.23) litres/min, steady state exercise VO(2) 1.67 (0.07) litres/min, on-tauVO(2) 38.0 (5.3) seconds, off-tauVO(2) 39.0 (4.3) seconds, and ramp-tauVO(2) 60.8 (15.4) seconds. On-tauVO(2) correlated with off-tauVO(2) (r = 0.87), VO(2)max (r = -0.73), and VO(2)theta (r = 0.89). The pooled mean tauVO(2) from six superimposed tests agreed with the arithmetic grand mean of the six tests. CONCLUSIONS: The average of on-tauVO(2) and off-tauVO(2) fell within the 95% confidence interval of the pooled mean by the second test. Ramp-tauVO(2) was longer and less reproducible. These findings support the use of both on- and off-transit data for the determination of tauVO(2), an approach that reduces the number of transitions necessary for accurate determination of tauVO(2), potentially enhancing its clinical application.


Assuntos
Exercício Físico/fisiologia , Consumo de Oxigênio/fisiologia , Aptidão Física/fisiologia , Adulto , Coleta de Dados , Ergometria , Teste de Esforço/métodos , Humanos , Cinética , Ácido Láctico/sangue , Masculino , Garantia da Qualidade dos Cuidados de Saúde , Análise de Regressão , Reprodutibilidade dos Testes
9.
AIDS Res Hum Retroviruses ; 17(15): 1423-33, 2001 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-11679155

RESUMO

HIV-1 cardiomyopathy has become a major cause of death in AIDS patients, but its pathogenesis is unclear. We used an antigen retrieval technique and immunostaining to investigate the hearts of 15 AIDS patients, of whom 3 had dilated cardiomyopathy. Immunocytochemistry shows infiltration of the left ventricular myocardium with mononuclear cells, ranging from minimal to diagnostic of myocarditis. The infiltrates include macrophages and CD3(+) and CD8(+) T cells. The tight junction protein ZO-1 is disrupted at the site of monocyte-macrophage vascular penetration and the coronary vessels show fibrinogen leakage in the hearts of AIDS patients, but not in the normal heart. A subset of infiltrating macrophages is doubly positive for cyclooxygenase 2 (COX-2) and inducible nitric oxide synthase. HIV-1 peptides gp120 and Nef are expressed in macrophages and T cells, but not in cardiomyocytes. COX-2 is expressed by both gp120-positive and gp120-negative macrophages. The hearts of AIDS patients separate into those showing minimal infiltrates with low COX-2 expression and those with dense infiltrates and high COX-2; all failing hearts are in the latter group. These data suggest that COX-2-activated and HIV-1-infected monocyte-macrophages and T cells play a crucial role in the progression of HIV-1 myocarditis to HIV-1 cardiomyopathy.


Assuntos
Infecções por HIV/enzimologia , HIV-1/fisiologia , Isoenzimas/fisiologia , Ativação Linfocitária/imunologia , Ativação de Macrófagos/imunologia , Macrófagos/imunologia , Miocardite/imunologia , Prostaglandina-Endoperóxido Sintases/fisiologia , Linfócitos T/imunologia , Disfunção Ventricular Esquerda/imunologia , Encéfalo/imunologia , Vasos Coronários/imunologia , Ciclo-Oxigenase 2 , Infecções por HIV/complicações , Infecções por HIV/imunologia , Infecções por HIV/virologia , Humanos , Isoenzimas/metabolismo , Rim/imunologia , Leucócitos/imunologia , Fígado/imunologia , Macrófagos/virologia , Proteínas de Membrana , Miocardite/complicações , Miocardite/enzimologia , Miocardite/virologia , Óxido Nítrico Sintase/metabolismo , Óxido Nítrico Sintase Tipo II , Prostaglandina-Endoperóxido Sintases/metabolismo , Linfócitos T/virologia , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/enzimologia , Disfunção Ventricular Esquerda/virologia
10.
Radiology ; 221(1): 213-21, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11568343

RESUMO

PURPOSE: To determine differences in coronary artery calcium detection, quantification, and reproducibility, as measured at electron-beam computed tomography (CT) and subsecond spiral CT with retrospective electrocardiogram gating in an asymptomatic adult population. MATERIALS AND METHODS: Seventy subjects asymptomatic for coronary heart disease underwent both electron-beam CT and subsecond spiral CT. In all subjects, two images each were obtained with both scanners. Two experienced readers using three different algorithms scored each of the four scans: one score for the electron-beam CT images and two scores for the spiral CT images. RESULTS: With a 130-HU threshold for the quantification of calcium, there were no significant differences in interscan and interobserver variation in calcium scores between the electron-beam CT and spiral CT images. There was greater interobserver (P <.001) and interscan (P <.03) variation in scores when a 90-HU threshold was used for spiral CT images. With a 130-HU threshold, when calcium scores were used for clinical risk stratification, there was a significant difference between the results obtained with electron-beam CT and those obtained with spiral CT (P <.05). CONCLUSION: Spiral CT has not yet proved to be a feasible alternative to electron-beam CT for coronary artery calcium quantification. There are systematic differences between calcium scores obtained with single-detector array subsecond spiral CT and those obtained with electron-beam CT.


Assuntos
Cálcio/análise , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco
11.
AJR Am J Roentgenol ; 177(3): 695-702, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11517078

RESUMO

OBJECTIVE: The purpose of this study was to compare both the volumes of the lateral ventricles and the cerebral white matter with gestational age at birth of children with periventricular white matter (PVWM) T2-signal hyperintensities on MR images. The spectrum of neuromotor abnormalities associated with these hyperintensities was also determined. MATERIALS AND METHODS: We retrospectively reviewed the MR images of 70 patients who were between the ages of 1 and 5 years and whose images showed PVWM T2-signal hyperintensities. The patients were divided into premature (n = 35 children) and term (n = 35) groups depending on their gestational age at birth. Volumetric analysis was performed on four standardized axial sections using T2-weighted images. Volumes of interest were digitized on the basis of gray-scale densities of signal intensities to define the hemispheric cerebral white matter and lateral ventricles. Age-adjusted comparisons of volumetric measurements between the premature and term groups were performed using analysis of covariance. RESULTS: The volume of the cerebral white matter was smaller in the premature group (54 +/- 2 cm(3)) than in the term group (79 +/- 3 cm(3), p < 0.0001). The volume of the lateral ventricles was greater among the patients in the premature group (30 +/- 2 cm(3)) than among those in the term group (13 +/- 1 cm(3), p < 0.0001). Fifty percent of all the premature children had spastic diplegia or quadriplegia. Thirty-two percent of all the term children had hypotonia. There were patients in both groups whose PVWM T2-signal hyperintensities did not correlate with any neuromotor abnormalities but were associated with seizures or developmental delays. CONCLUSION: The differences in volumetric measurements of cerebral white matter and lateral ventricles in children with PVWM T2-signal hyperintensities are related to their gestational age at birth. Several neurologic motor abnormalities are found in children with such hyperintensities.


Assuntos
Ventrículos Cerebrais/patologia , Doenças do Prematuro/diagnóstico , Leucomalácia Periventricular/diagnóstico , Imageamento por Ressonância Magnética , Peso ao Nascer , Encéfalo/patologia , Dano Encefálico Crônico/diagnóstico , Cefalometria , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Masculino , Prognóstico , Fatores de Risco
12.
AJR Am J Roentgenol ; 176(6): 1385-8, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11373197

RESUMO

OBJECTIVE: Data collected from 1985 to 1999 on adverse events after the IV administration of contrast media were evaluated to identify trends. MATERIALS AND METHODS: Data collected on 391 adverse events after 90,473 administrations of iodinated contrast media and 19 events after 28,340 administrations of gadolinium were evaluated. Reactions were graded as mild, moderate, or severe. Data were also collected regarding contrast extravasation. RESULTS: When only ionic iodinated contrast material was used, the adverse reaction rate was 6-8%. With the selective use of contrast material, the adverse reaction rate was 0.6% and 0.7%, respectively, for ionic and nonionic agents. The rate decreased to 0.2% with the universal use of nonionic agents. More than 90% of adverse reactions were allergic-like. Seven severe reactions (0.05%) and no deaths occurred in the ionic group. During the selective use period, one death occurred in the nonionic group. No severe reactions or deaths occurred during the first 5 years of universal nonionic use. Since then, 10 severe reactions (0.02%) and one death have occurred. Seven reactions occurred in patients after helical CT angiography. The extravasation rate for iodinated contrast material has remained constant at 0.3-0.4% annually. The adverse reaction rate to gadolinium contrast material was 0.06%. CONCLUSION: Mild and moderate adverse events are more common with ionic contrast material than with nonionic. Most reactions are allergic-like. Severe reactions are seen equally with ionic and nonionic contrast material but differ in type. The reactions were allergic-like in the ionic group but were predominantly attributable to cardiopulmonary decompensation in the nonionic group. Helical CT angiography may play a role in reactions.


Assuntos
Meios de Contraste/efeitos adversos , Sistemas de Notificação de Reações Adversas a Medicamentos/estatística & dados numéricos , Meios de Contraste/administração & dosagem , Hipersensibilidade a Drogas/epidemiologia , Gadolínio/administração & dosagem , Gadolínio/efeitos adversos , Humanos , Injeções Intravenosas
13.
Radiat Res ; 155(5): 740-3, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11302772

RESUMO

Norman, A., Cochran, S. T. and Sayre, J. W. Meta-analysis of Increases in Micronuclei in Peripheral Blood Lymphocytes after Angiography or Excretory Urography. Radiat. Res. 155, 740-743 (2001). Meta-analysis of 10 studies confirms a significant increase in the frequency of micronuclei in peripheral blood lymphocytes after angiography or excretory urography; the weighted average increase is 4.2 (95% confidence interval 2.8-5.6) per 1000 binucleate lymphocytes, about the same increase in micronuclei as that produced in vitro by a diagnostic X-ray dose of 4 cGy. The analysis failed to reveal a significant effect of the specific contrast medium used in the X-ray examinations on the increased frequency of micronuclei. These results are consistent with the hypothesis that the effect of the contrast media is limited to the enhancement, by the photoelectric effect, of the X-ray dose absorbed by the lymphocytes irradiated while suspended in the contrast medium. Therefore, an estimate of increased cancer risk based on elevated frequencies of micronuclei or chromosome aberrations in peripheral blood lymphocytes may be greatly exaggerated whenever the radiation damage is largely confined to the cells circulating in the blood, as it is in people who have recently had X-ray examinations that use intravenous injections of contrast medium. Such examinations include angiography, excretory urography and CT scans, which are received annually by millions of people.


Assuntos
Angiografia/efeitos adversos , Linfócitos/efeitos da radiação , Micronúcleos com Defeito Cromossômico/efeitos da radiação , Urografia/efeitos adversos , Aberrações Cromossômicas , Meios de Contraste/efeitos adversos , Humanos , Linfócitos/ultraestrutura
14.
Radiology ; 218(3): 724-32, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11230646

RESUMO

PURPOSE: To evaluate the cause of complications in intraarterial chemotherapy for brain tumors and validate a dosage algorithm based on arterial territory. MATERIALS AND METHODS: Four hundred sixty-two procedures were performed in 113 patients. Technique included pulsatile infusion of a chemotherapeutic agent. Dosage was calculated per hemisphere and divided per arterial territory according to a spatial dose fractionation algorithm based on the vascular territories of major cerebral arteries: middle cerebral artery, 60%; anterior cerebral artery, 20%; posterior cerebral artery, 15%; and perforator arteries, 5%. Hospital charts of all patients were retrospectively reviewed for complications, with specific attention given to the angiograms to determine a cause. Then, subgroup analysis of the chemotherapy protocol with the largest patient population was performed to evaluate predictors of complications. RESULTS: Six (1.3%) complications were asymptomatic; 12 (2.6%), transient neurologic; three (0.6%), permanent minor neurologic; three (0.6%), permanent major neurologic; and 32 (7.0%), seizures. In the subgroup analysis, the hemispheric dose administered according to the algorithm was strongly predictive of seizure and neurologic deficit. CONCLUSION: Neurotoxicity of intraarterial cerebral chemotherapy can be minimized by using pulsatile injection and the described spatial dose fractionation algorithm.


Assuntos
Neoplasias Encefálicas/tratamento farmacológico , Infusões Intra-Arteriais/efeitos adversos , Adolescente , Adulto , Idoso , Algoritmos , Antineoplásicos/administração & dosagem , Astrocitoma/tratamento farmacológico , Artérias Cerebrais , Criança , Pré-Escolar , Feminino , Glioblastoma/tratamento farmacológico , Humanos , Masculino , Pessoa de Meia-Idade , Fluxo Pulsátil
15.
Radiology ; 218(3): 816-23, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11230661

RESUMO

PURPOSE: To determine whether measurements with transcranial Doppler ultrasonography (US) of resistive indexes (RIs) of basal cerebral arteries with pressure provocation can be used to identify infants and children with craniosynostosis who have abnormal intracranial compliance and to study the effects of surgery on compliance. MATERIALS AND METHODS: Transcranial Doppler US was performed through the temporal squama, fontanels, and existing skull defects prior to and immediately following cranioplasty. Twenty-four studies were performed in six patients with multisuture synostosis, and 61 studies were performed in 26 patients with single-suture synostosis. Study findings were compared with those of 23 control subjects and were characterized as normal or abnormal on the basis of age-specific normal criteria for RI. RESULTS: In multisuture synostosis, results of six of the nine preoperative transcranial Doppler US studies were abnormal. During postoperative follow-up, three recurrences requiring reoperation occurred, one of which was detected with abnormal transcranial Doppler US findings. In single-suture synostosis, results of seven of the 26 preoperative transcranial Doppler US studies were abnormal, and all occurred in young infants with sagittal and unicoronal synostosis. Immediate effects of surgery were variable. All patients with sagittal synostosis had a significant immediate postoperative increase in RI, which normalized during postoperative follow-up. There was no significant difference in RI between patients with successfully treated craniosynostosis and control subjects. CONCLUSION: Transcranial Doppler US can be used to identify patients with craniosynostosis with decreased intracranial compliance, and it is a suitable noninvasive test to monitor the effects of surgery on compliance.


Assuntos
Craniossinostoses/diagnóstico por imagem , Craniossinostoses/cirurgia , Ultrassonografia Doppler Transcraniana , Pré-Escolar , Complacência (Medida de Distensibilidade) , Craniossinostoses/fisiopatologia , Feminino , Humanos , Lactente , Masculino , Padrões de Referência , Crânio/fisiopatologia , Ultrassonografia Doppler Transcraniana/métodos
16.
IEEE Trans Med Imaging ; 20(12): 1242-50, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11811824

RESUMO

The purpose of this work is to develop patient-specific models for automatically detecting lung nodules in computed tomography (CT) images. It is motivated by significant developments in CT scanner technology and the burden that lung cancer screening and surveillance imposes on radiologists. We propose a new method that uses a patient's baseline image data to assist in the segmentation of subsequent images so that changes in size and/or shape of nodules can be measured automatically. The system uses a generic, a priori model to detect candidate nodules on the baseline scan of a previously unseen patient. A user then confirms or rejects nodule candidates to establish baseline results. For analysis of follow-up scans of that particular patient, a patient-specific model is derived from these baseline results. This model describes expected features (location, volume and shape) of previously segmented nodules so that the system can relocalize them automatically on follow-up. On the baseline scans of 17 subjects, a radiologist identified a total of 36 nodules, of which 31 (86%) were detected automatically by the system with an average of 11 false positives (FPs) per case. In follow-up scans 27 of the 31 nodules were still present and, using patient-specific models, 22 (81%) were correctly relocalized by the system. The system automatically detected 16 out of a possible 20 (80%) of new nodules on follow-up scans with ten FPs per case.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Modelos Biológicos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Automação , Reações Falso-Negativas , Seguimentos , Humanos , Estudos Retrospectivos , Sensibilidade e Especificidade
17.
Med Phys ; 27(3): 592-8, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10757610

RESUMO

The assessment of differential left and right lung function is important for patients under consideration for lung resection procedures such as single lung transplantation. We developed an automated, knowledge-based segmentation algorithm for purposes of deriving functional information from dynamic computed tomography (CT) image data. Median lung attenuation (HU) and area measurements were automatically calculated for each lung from thoracic CT images acquired during a forced expiratory maneuver as indicators of the amount and rate of airflow. The accuracy of these derived measures from fully automated segmentation was validated against those from segmentation using manual editing by an expert observer. A total of 1313 axial images were analyzed from 49 patients. The images were segmented using our knowledge-based system that identifies the chest wall, mediastinum, trachea, large airways and lung parenchyma on CT images. The key components of the system are an anatomical model, an inference engine and image processing routines, and segmentation involves matching objects extracted from the image to anatomical objects described in the model. The segmentation results from all images were inspected by the expert observer. Manual editing was required to correct 183 (13.94%) of the images, and the sensitivity, specificity, and accuracy of the knowledge-based segmentation were greater than 98.55% in classifying pixels as lung or nonlung. There was no significant difference between median lung attenuation or area values from automated and edited segmentations (p > 0.70). Using the knowledge-based segmentation method we can automatically derive indirect quantitative measures of single lung function that cannot be obtained using conventional pulmonary function tests.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Pulmão/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Asma/diagnóstico por imagem , Estudos de Casos e Controles , Enfisema/diagnóstico por imagem , Humanos , Pneumopatias Obstrutivas/diagnóstico por imagem , Transplante de Pulmão/diagnóstico por imagem , Medidas de Volume Pulmonar , Fatores de Tempo
18.
AJNR Am J Neuroradiol ; 21(3): 471-8, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10730637

RESUMO

BACKGROUND AND PURPOSE: Factors predictive of primary brain tumor outcome have been studied extensively, although the prognostic value of radiologic data, such as MR imaging and angiographic characteristics, has not been studied in depth. The purpose of this study was to determine whether radiologic data were prognostic factors among patients with recurrent glioblastoma multiforme and anaplastic astrocytoma treated with selective intra-arterial chemotherapy. METHODS: Forty-six patients were enrolled in a Phase II study of intra-arterial chemotherapy with carboplatin and Cereport (Alkermes Inc.; Cambridge, MA), a bradykinin analog that selectively increases permeability of the blood-tumor barrier. MR imaging volumes of enhancing tumor, resection cavity, and T2 signal abnormality were measured with T1-weighted and T2-weighted sequences. Volumes were analyzed individually and in various combinations. Tumor vascularity was graded on angiograms. Outcome was measured by time to tumor progression and survival. RESULTS: Of 46 patients included in this study, 41 underwent evaluation. Thirty were male and 11 were female; mean age was 48.5 years. Karnofsky scores ranged from 70 to 100. Thirty-two patients had glioblastoma multiforme, whereas nine had anaplastic astrocytoma. Twenty-eight patients had tumor progression and 13 had stable disease. Twenty-three patients died after an average of 205 days; 18 were surviving at an average of 324 days from the start of intra-arterial chemotherapy. In multivariate analysis, time from diagnosis to intra-arterial chemotherapy was predictive both of time to tumor progression and survival. Net tumor volume and vascularity also were significant for survival. Age, Karnofsky performance status, histologic findings, gender, MR imaging area, resection cavity volume, T2 signal abnormality volume, and various combined volumes were not significant. CONCLUSION: If confirmed by further studies, radiologic factors such as tumor volume and angiographic vascularity should be considered in design and stratification of future chemotherapy trials.


Assuntos
Antineoplásicos/administração & dosagem , Bradicinina/análogos & derivados , Neoplasias Encefálicas/tratamento farmacológico , Carboplatina/administração & dosagem , Glioblastoma/tratamento farmacológico , Infusões Intra-Arteriais , Recidiva Local de Neoplasia/tratamento farmacológico , Adulto , Idoso , Bradicinina/administração & dosagem , Encéfalo/patologia , Neoplasias Encefálicas/irrigação sanguínea , Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/mortalidade , Angiografia Cerebral , Progressão da Doença , Feminino , Glioblastoma/irrigação sanguínea , Glioblastoma/diagnóstico , Glioblastoma/mortalidade , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida
19.
Am J Physiol Heart Circ Physiol ; 278(2): H360-6, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10666065

RESUMO

Mental stress testing has been proposed as a noninvasive tool to evaluate endothelium-dependent coronary vasomotion. In patients with coronary artery disease, mental stress can induce myocardial ischemia. However, even the determinants of the physiological myocardial blood flow (MBF) response to mental stress are poorly understood. Twenty-four individuals (12 males/12 females, mean age 49 +/- 13 yr, range 31-74 yr) with a low likelihood for coronary artery disease were studied. Serum catecholamines, cardiac work, and MBF (measured quantitatively with N-13 ammonia and positron emission tomography) were assessed. During mental stress (arithmetic calculation) MBF increased significantly from 0.70 +/- 0.14 to 0.92 +/- 0.21 ml x min(-1) x g(-1) (P < 0.01). Mental stress caused significant increases (P < 0.01) in serum epinephrine (26 +/- 16 vs. 42 +/- 17 pg/ml), norepinephrine (272 +/- 139 vs. 322 +/- 136 pg/ml), and cardiac work [rate-pressure product (RPP) 8,011 +/- 1,884 vs. 10,416 +/- 2,711]. Stress-induced changes in cardiac work were correlated with changes in MBF (r = 0.72; P < 0.01). Multiple-regression analysis revealed stress-induced changes in the RPP as the only significant (P = 0.0001) predictor for the magnitude of mental stress-induced increases in MBF in healthy individuals. Data from this group of healthy individuals should prove useful to investigate coronary vasomotion in individuals at risk for or with documented coronary artery disease.


Assuntos
Circulação Coronária , Estresse Psicológico/fisiopatologia , Adulto , Amônia , Colesterol/sangue , Vasos Coronários/fisiopatologia , Epinefrina/sangue , Feminino , Coração/diagnóstico por imagem , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Radioisótopos de Nitrogênio , Norepinefrina/sangue , Valores de Referência , Estresse Psicológico/sangue , Tomografia Computadorizada de Emissão , Resistência Vascular
20.
J Allergy Clin Immunol ; 104(6): S258-67, 1999 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-10588987

RESUMO

A double-blind, randomized, parallel-group pilot study compared the relative efficacy of hydrofluoroalkane-134a beclomethasone dipropionate (HFA-BDP [QVAR]; mass median aerodynamic diameter, 0. 8-1.2 m) versus cholorofluorocarbon-11/12 BDP (CFC-BDP [Beclovent]; mass median aerodynamic diameter, 3.5-4.0 m) in 31 steroid naive patients with mild to moderate asthma (PC(20,) 4 mg/mL). Functional high-resolution computed tomography was used to assess the relative efficacy of HFA-BDP and CFC-BDP on regional air trapping, as an indirect measure of small airways function and on regional hyperreactivity. Pretreatment functional computed tomography was performed at residual volume before and after methacholine challenge. After 4 weeks of treatment, functional imaging was repeated before and after the same concentration of methacholine that was administered before the treatment (n = 19 patients). Quantitative assessment of changes in distribution of lung attenuation was performed. After 4 weeks of treatment, the HFA-BDP group showed significantly more improvement in air trapping overall (a shift in the lung attenuation curve at residual volume toward more attenuation) on the posttreatment computed tomography scan (P <.05; Fisher's Exact Test). After an equal constrictor stimulus (methacholine concentration), subjects treated with HFA-BDP (n = 10 patients) showed less increase in air trapping overall than subjects treated with CFC-BDP (n = 9 patients) on the posttreatment scans compared with the pretreatment scans (P <.001; Fisher's Exact Test). No significant difference was demonstrated between the 2 treatment groups with respect to improvement in symptoms, spirometry, or methacholine responsiveness assessed by FEV(1), except for a greater reduction in breathlessness in the HFA-BDP group (P <.05). We conclude that HFA-BDP may have greater efficacy in the peripheral airways and that this effect is better assessed with functional imaging computed tomography techniques than with conventional physiologic tests.


Assuntos
Propelentes de Aerossol/farmacologia , Beclometasona/farmacologia , Clorofluorcarbonetos/farmacologia , Hidrocarbonetos Fluorados/farmacologia , Administração por Inalação , Adulto , Propelentes de Aerossol/administração & dosagem , Asma/tratamento farmacológico , Beclometasona/administração & dosagem , Testes de Provocação Brônquica , Clorofluorcarbonetos/administração & dosagem , Método Duplo-Cego , Feminino , Humanos , Hidrocarbonetos Fluorados/administração & dosagem , Processamento de Imagem Assistida por Computador , Pulmão/efeitos dos fármacos , Masculino , Pessoa de Meia-Idade , Pico do Fluxo Expiratório , Projetos Piloto , Testes de Função Respiratória , Espirometria , Tomógrafos Computadorizados
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...