Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Cardiothorac Surg ; 14(1): 171, 2019 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-31533769

RESUMO

BACKGROUND: The treatment of persistent air leak is a challenge. Herein, we reported the combined intrabronchial and intrapleural injection of fibrin glue using fiber bronchoscopy to seal off an alveolar pleura fistula developed following necrotizing pneumonia in high-risk patient. CASE PRESENTATION: A 74-year-old man was intubated in emergency for acute ischemic stroke. Percutaneous dilatational tracheostomy was then performed, and 15 days later patient returned to spontaneous breathing. However, he developed alveolar pleural fistula following necrotizing pneumonia with persistent air leaks. The intrabronchial and intrapleural injection of fibrin glue using fiber bronchoscopy sealed off the alveolar pleura fistula after that other endoscopic treatments as bronchial valve and intrabronchial fibrin glue application had failed. CONCLUSIONS: Our strategy is safe and easy to reproduce. It represents an additional method in the armamentarium of the physicians for the management of PAL when all standard strategies are unfeasible or fail.


Assuntos
Fístula Brônquica/cirurgia , Adesivo Tecidual de Fibrina/uso terapêutico , Doenças Pleurais/tratamento farmacológico , Alvéolos Pulmonares/cirurgia , Idoso , Isquemia Encefálica/complicações , Brônquios , Fístula Brônquica/tratamento farmacológico , Broncoscopia , Endoscopia , Fístula/complicações , Humanos , Injeções , Masculino , Doenças Pleurais/etiologia , Acidente Vascular Cerebral/complicações , Traqueostomia/efeitos adversos
2.
Recenti Prog Med ; 104(12): 625-30, 2013 Dec.
Artigo em Italiano | MEDLINE | ID: mdl-24362831

RESUMO

Pulse oximetry is now a widely available technology that provides easy and continuous reliable measurements of oxygen saturation, the percentage of O2 bound to Hb (SpO2). Pulse oximetry has become a standard monitoring not only in intensive care, but also in other clinical settings, although several factors can interfere with a correct reading, as low perfusion conditions, such as low cardiac output, vasoconstriction, hypothermia. We performed a prospective observational study in two groups of twenty-eight patients admitted to the ICU, in which we compared the values ​​obtained (SpO2) with digital and forehead pulse oximetry, with arterial oxygen saturation (SaO2) obtained from blood gas analysis (EGA). Comparison measurements into two distinct groups, though homogeneous might be a limitation of the study, but at the same time provide a representative picture of a polyvalent intensive care unit. The result was that both the values ​​obtained with digital and frontal pulse oximetry are accurate and reliable in comparison to EGA. In situations of hypoxia, the reliability of frontal pulse oximetry appears superior compared to digital oximetry.


Assuntos
Cuidados Críticos/métodos , Monitorização Fisiológica/métodos , Oximetria/métodos , Feminino , Dedos , Testa , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
3.
Recenti Prog Med ; 99(9): 458-60, 2008 Sep.
Artigo em Italiano | MEDLINE | ID: mdl-19044255

RESUMO

This case report has the scope to review the etiology and pathophysiology of pneumomediastinum in severe blunt trauma, with a special interest to its more frequent origin: the Macklin effect. The Macklin effect is a pathophysiologic process characterized by the blunt traumatic alveolar ruptures, air dissection along bronchovascular sheaths, with the formation of blunt pulmonary interstitial emphysema, radiologic marker, until the formation of a pneumomediastinum. Its premature diagnostic acknowledgment is important in the managing of the blunt chest trauma.


Assuntos
Enfisema Mediastínico/etiologia , Traumatismos Torácicos/complicações , Humanos , Masculino , Enfisema Mediastínico/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA