Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Influenza Other Respir Viruses ; 18(4): e13282, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38622776

RESUMO

INTRODUCTION: Human respiratory syncytial virus (RSV) is one of the most frequent causes of respiratory infections in children under 5 years of age, but its socioeconomic impact and burden in primary care settings is still little studied. METHODS: During the 2022/2023 winter season, 55 pediatricians from five Italian regions participated in our community-based study. They collected a nasal swab for RSV molecular test from 650 patients under the age of 5 with acute respiratory infections (ARIs) and performed a baseline questionnaire. The clinical and socioeconomic burden of RSV disease in primary care was evaluated by two follow-up questionnaires completed by the parents of positive children on Days 14 and 30. RESULTS: RSV laboratory-confirmed cases were 37.8% of the total recruited ARI cases, with RSV subtype B accounting for the majority (65.4%) of RSV-positive swabs. RSV-positive children were younger than RSV-negative ones (median 12.5 vs. 16.5 months). The mean duration of symptoms for all children infected by RSV was 11.47 ± 6.27 days. We did not observe substantial differences in clinical severity between the two RSV subtypes, but RSV-A positive patients required more additional pediatric examinations than RSV-B cases. The socioeconomic impact of RSV infection was considerable, causing 53% of children to be absent from school, 46% of parents to lose working days, and 25% of families to incur extra costs. CONCLUSIONS: Our findings describe a baseline of the RSV disease burden in primary care in Italy before the introduction of upcoming immunization strategies.


Assuntos
Infecções por Vírus Respiratório Sincicial , Vírus Sincicial Respiratório Humano , Infecções Respiratórias , Humanos , Criança , Lactente , Pré-Escolar , Infecções por Vírus Respiratório Sincicial/epidemiologia , Estações do Ano , Itália/epidemiologia , Efeitos Psicossociais da Doença , Atenção Primária à Saúde , Hospitalização
2.
Artigo em Inglês | MEDLINE | ID: mdl-37239594

RESUMO

The role of microplastics (MPs) in the spread of antibiotic resistance genes (ARGs) is increasingly attracting global research attention due to their unique ecological and environmental effects. The ubiquitous use of plastics and their release into the environment by anthropic/industrial activities are the main sources for MP contamination, especially of water bodies. Because of their physical and chemical characteristics, MPs represent an ideal substrate for microbial colonization and formation of biofilm, where horizontal gene transfer is facilitated. In addition, the widespread and often injudicious use of antibiotics in various human activities leads to their release into the environment, mainly through wastewater. For these reasons, wastewater treatment plants, in particular hospital plants, are considered hotspots for the selection of ARGs and their diffusion in the environment. As a result, the interaction of MPs with drug-resistant bacteria and ARGs make them vectors for the transport and spread of ARGs and harmful microorganisms. Microplastic-associated antimicrobial resistance is an emerging threat to the environment and consequently for human health. More studies are required to better understand the interaction of these pollutants with the environment as well as to identify effective management systems to reduce the related risk.


Assuntos
Microplásticos , Águas Residuárias , Humanos , Plásticos , Genes Bacterianos , Resistência Microbiana a Medicamentos/genética , Antibacterianos/farmacologia , Hospitais
3.
Artigo em Inglês | MEDLINE | ID: mdl-36901293

RESUMO

Improving the cleaning and disinfection of high-touch surfaces is one of the core components of reducing healthcare-associated infections. The effectiveness of an enhanced protocol applying UV-C irradiation for terminal room disinfection between two successive patients was evaluated. Twenty high-touch surfaces in different critical areas were sampled according to ISO 14698-1, both immediately pre- and post-cleaning and disinfection standard operating protocol (SOP) and after UV-C disinfection (160 sampling sites in each condition, 480 in total). Dosimeters were applied at the sites to assess the dose emitted. A total of 64.3% (103/160) of the sampling sites tested after SOP were positive, whereas only 17.5% (28/160) were positive after UV-C. According to the national hygienic standards for health-care setting, 9.3% (15/160) resulted in being non-compliant after SOP and only 1.2% (2/160) were non-compliant after UV-C disinfection. Operation theaters was the setting that resulted in being less compliant with the standard limit (≤15 colony-forming unit/24 cm2) after SOP (12%, 14/120 sampling sites) and where the UV-C treatment showed the highest effectiveness (1.6%, 2/120). The addition of UV-C disinfection to the standard cleaning and disinfection procedure had effective results in reducing hygiene failures.


Assuntos
Infecção Hospitalar , Robótica , Humanos , Desinfecção/métodos , Xenônio , Hospitais , Raios Ultravioleta
4.
Artigo em Inglês | MEDLINE | ID: mdl-36360859

RESUMO

BACKGROUND: In the past few decades, the inadequate reprocessing of bronchoscopes has been associated with several serious outbreaks caused by multidrug-resistant microorganisms. In this study we evaluated the improvement in the quality of reprocessing in a Bronchoscopy Unit (BU), after the introduction of a new procedure. METHODS: In 2019, observational and clinical audits were conducted in the BU. After the introduction of an improved procedure in 2020, a microbiological surveillance plan was implemented in 2021. RESULTS: In 2019, 13 of 22 bronchoscopes (59%) resulted as non-compliant, 18% as high concern organisms (HCO) and 36.4% as high microbial count (≥100 CFU/all channels) and HCO. The most frequent microorganisms were Staphylococcus aureus (38.5%) and NDM-producing Klebsiella pneumoniae (15.4%). The bronchoscopes were stored inside their transport cases, which in some cases were found to be contaminated by the same strains isolated on the bronchoscopes (Enterobacter gergoviae and Vibrio alginolyticus). In 2021, all 31 bronchoscopes were sampled at least three times and 13/99 (13.1%) resulted as non-compliant, mostly K. pneumoniae (4.04%). Contamination level increases weakly in bronchoscopes in use for more than 14 years (R = 0.32). CONCLUSIONS: The adoption of an improved reprocessing procedure decreased the non-compliance of bronchoscopes, increasing the quality of the process and patient safety.


Assuntos
Broncoscópios , Infecção Hospitalar , Broncoscópios/microbiologia , Infecção Hospitalar/epidemiologia , Desinfecção/métodos , Contaminação de Equipamentos/prevenção & controle , Klebsiella pneumoniae
5.
Artigo em Inglês | MEDLINE | ID: mdl-36231398

RESUMO

Background: Correct reprocessing and microbiological surveillance on endoscopes are fundamental for preventing the transmission of multi-drug resistant strains and device-related infections. Methods: A questionnaire with three domains was created: (1) centre characteristics; (2) endoscope reprocessing procedures; and (3) application of microbiological surveillance. Nurses working in endoscopic units across Italy were invited to anonymously fill out the questionnaire on the SurveyMonkey platform between November 2021 and February 2022. Results: A total of 82 out of 132 endoscopic centres participated in the survey, with at least one centre from each Italian region. Data found different concerns regarding the current practice of both reprocessing and microbiological surveillance. According to respondents, the training on reprocessing was performed through theoretical training and only in 10% of centres; the microbiological surveillance was regularly performed in 59% of centres; and sampled endoscopes were not excluded for use in 31% of centres performing the surveillance until the outcome was pending, and when positive, 72% maintained them in quarantine until a successive negative result. Conclusions: Reprocessing and microbiological surveillance currently present several criticisms along the endoscopic centres in Italy. Our survey highlights the need for the correct application of the national recommendations in each endoscopic centre to prevent the potential transmission of endoscope-related infections.


Assuntos
Desinfecção , Contaminação de Equipamentos , Desinfecção/métodos , Endoscópios , Contaminação de Equipamentos/prevenção & controle , Humanos , Itália , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...