Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nat Nanotechnol ; 17(3): 301-309, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34937934

RESUMO

Mapping the entire frequency bandwidth of brain electrophysiological signals is of paramount importance for understanding physiological and pathological states. The ability to record simultaneously DC-shifts, infraslow oscillations (<0.1 Hz), typical local field potentials (0.1-80 Hz) and higher frequencies (80-600 Hz) using the same recording site would particularly benefit preclinical epilepsy research and could provide clinical biomarkers for improved seizure onset zone delineation. However, commonly used metal microelectrode technology suffers from instabilities that hamper the high fidelity of DC-coupled recordings, which are needed to access signals of very low frequency. In this study we used flexible graphene depth neural probes (gDNPs), consisting of a linear array of graphene microtransistors, to concurrently record DC-shifts and high-frequency neuronal activity in awake rodents. We show here that gDNPs can reliably record and map with high spatial resolution seizures, pre-ictal DC-shifts and seizure-associated spreading depolarizations together with higher frequencies through the cortical laminae to the hippocampus in a mouse model of chemically induced seizures. Moreover, we demonstrate the functionality of chronically implanted devices over 10 weeks by recording with high fidelity spontaneous spike-wave discharges and associated infraslow oscillations in a rat model of absence epilepsy. Altogether, our work highlights the suitability of this technology for in vivo electrophysiology research, and in particular epilepsy research, by allowing stable and chronic DC-coupled recordings.


Assuntos
Epilepsia , Grafite , Animais , Eletroencefalografia , Camundongos , Microeletrodos , Ratos , Convulsões
2.
Nano Lett ; 20(5): 3528-3537, 2020 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-32223249

RESUMO

Sensor arrays used to detect electrophysiological signals from the brain are paramount in neuroscience. However, the number of sensors that can be interfaced with macroscopic data acquisition systems currently limits their bandwidth. This bottleneck originates in the fact that, typically, sensors are addressed individually, requiring a connection for each of them. Herein, we present the concept of frequency-division multiplexing (FDM) of neural signals by graphene sensors. We demonstrate the high performance of graphene transistors as mixers to perform amplitude modulation (AM) of neural signals in situ, which is used to transmit multiple signals through a shared metal line. This technology eliminates the need for switches, remarkably simplifying the technical complexity of state-of-the-art multiplexed neural probes. Besides, the scalability of FDM graphene neural probes has been thoroughly evaluated and their sensitivity demonstrated in vivo. Using this technology, we envision a new generation of high-count conformal neural probes for high bandwidth brain machine interfaces.


Assuntos
Mapeamento Encefálico , Interfaces Cérebro-Computador , Encéfalo/diagnóstico por imagem , Grafite , Animais , Ratos
3.
Small ; 16(16): e1906640, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32187840

RESUMO

Graphene solution-gated field-effect transistors (g-SGFETs) are promising sensing devices to transduce electrochemical potential signals in an electrolyte bath. However, distortion mechanisms in g-SGFET, which can affect signals of large amplitude or high frequency, have not been evaluated. Here, a detailed characterization and modeling of the harmonic distortion and non-ideal frequency response in g-SGFETs is presented. This accurate description of the input-output relation of the g-SGFETs allows to define the voltage- and frequency-dependent transfer functions, which can be used to correct distortions in the transduced signals. The effect of signal distortion and its subsequent calibration are shown for different types of electrophysiological signals, spanning from large amplitude and low frequency cortical spreading depression events to low amplitude and high frequency action potentials. The thorough description of the distortion mechanisms presented in this article demonstrates that g-SGFETs can be used as distortion-free signal transducers not only for neural sensing, but also for a broader range of applications in which g-SGFET sensors are used.


Assuntos
Grafite , Neurônios/fisiologia , Transistores Eletrônicos , Potenciais de Ação , Depressão Alastrante da Atividade Elétrica Cortical
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA